Standard RLL Instructions Accumulator Logic Instructions
Exclusive Or with Stack (XORS)
430 440 450
DS
HPP
The Exclusive Or with Stack instruction is a 32 bit instruction that performs an exclusive or of the value in the accumulator with the first level of the accumulator stack. The result resides in the accumulator. The value in the first level of the accumulator stack is removed from the stack and all values are moved up one level. Discrete status flags indicate if the result of the Exclusive Or with Stack is zero or a negative number (the most significant bit is on).
XORS
Discrete Bit Flags
Description
SP63
Will be on if the result in the accumulator is zero
SP70
Will be on is the result in the accumulator is negative
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example when X1 is on, the binary value in the accumulator will be exclusive Hoped with the binary value in the first level of the accumulator stack. The result will reside in the accumulator. DirectSOFT X1
V1400
V1401
LDD
5
V1400
4
7
E
2
8
7
A
Load the value in V1400 and V1401 into the accumulator 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
4 3
2
1
0
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1
1
1
0
0
0
1
0
1
0
0
0
0
1
1
1
1
0
1
0
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1
1
1
0
0
0
1
0
1
0
0
0
0
1
1
1
1
0
1
0
0
0
1
1
0
1
1
0
0
1
0
0
0
1
1
1
0
1
1
0
1
0
1
0
0
0
1
1
1
0
0
0
0
1 0
1 0
0
0
0 1
1 0
0
0
0
1 0
1 0
1 0
0
0
1 0
0
1
0
0
0
0
1
0
0
1
0
0
0
0
1
0
2
3
9
4
2
4
2
XORS
36476A38 Exclusive OR the value in the accumulator with XOR (1st level of stack) the value in the first level of the Acc. accumulator stack OUTD V1500
6
Copy the value in the accumulator to V1500 and V1501
V1501
V1500
Handheld Programmer Keystrokes STR
X(IN)
1
SHFT
D
SHFT
V
1
X
SHFT
OR
SHFT
S
OUT
SHFT
D
SHFT
V
1
4
0
0
5
0
0
Standard RLL Instructions
LD SHFT
DL405 User Manual, 4th Edition
Page 254
5--82
Standard RLL Instructions Accumulator Logic Instructions
Compare (CMP)
430 440 450
DS
HPP
The compare instruction is a 16 bit instruction that compares the value in the lower 16 bits of the accumulator with the value in a specified V--memory location (Aaaa). The corresponding status flag will be turned on indicating the result of the comparison. You can compare either binary or BCD numbers, as long as both numbers are of the same data type. Operand Data Type
CMP A aaa
DL430 Range
DL440 Range
DL450 Range
A aaa aaa aaa
V--memory
V
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Pointer
P
----
All (See p. 3--41)
All (See p. 3--42)
Discrete Bit Flags
Description
SP60
On when the value in the accumulator is less than the instruction value.
SP61
On when the value in the accumulator is equal to the instruction value.
SP62
On when the value in the accumulator is greater than the instruction value.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example when X1 is on, the constant 4526 will be loaded into the lower 16 bits of the accumulator using the Load instruction. The value in the accumulator is compared with the value in V1410 using the Compare instruction. The corresponding discrete status flag will be turned on indicating the result of the comparison. In this example, if the value in the accumulator is less than the value specified in the Compare instruction, SP60 will turn on energizing C30. DirectSOFT X1
K4526
Load the constant value 4526 into the lower 16 bits of the accumulator
V1410
Compare the value in the accumulator with the value in V1410
LD
CMP
SP60
Standard RLL Instructions
5
2
6
4
5
2
6
The unused accumulator bits are set to zero Acc. 0
0
0
0
C30 OUT
Compared with 8
Handheld Programmer Keystrokes
9
4
V1410
STR
X(IN)
1
LD
K(CON)
4
5
2
6
CMP
V
1
4
1
0
STR
SPCL
6
0
OUT
C(CR)
3
0
DL405 User Manual, 4th Edition
Constant 4
5
Page 255
5--83
Standard RLL Instructions Accumulator Logic Instructions
Compare Double (CMPD)
430 440 450
DS
HPP
The Compare Double instruction is a 32--bit instruction that compares the value in the accumulator with the value (Aaaa), which is either two consecutive V--memory locations or an 8--digit (max.) constant. The corresponding status flag will be turned on indicating the result of the comparison. You can compare either binary or BCD numbers, as long as both numbers are of the same data type. Operand Data Type
CMPD A aaa
DL430 Range
DL440 Range
DL450 Range
A aaa aaa aaa
V--memory
V
----
All (See p. 3--41)
All (See p. 3--42)
Pointer
P
----
All (See p. 3--41)
All (See p. 3--42)
Constant
K
0--FFFFFFFF
0--FFFFFFFF
0--FFFFFFFF
Discrete Bit Flags
Description
SP60
On when the value in the accumulator is less than the instruction value.
SP61
On when the value in the accumulator is equal to the instruction value.
SP62
On when the value in the accumulator is greater than the instruction value.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example when X1 is on, the value in V1400 and V1401 will be loaded into the accumulator using the Load Double instruction. The value in the accumulator is compared with the value in V1410 and V1411 using the CMPD instruction. The corresponding discrete status flag will be turned on indicating the result of the comparison. In this example, if the value in the accumulator is less than the value specified in the Compare instruction, SP60 will turn on energizing C30. DirectSOFT X1
V1400
Compare the value in the accumulator with the value in V1410 and V1411
CMPD V1410
SP60
V1400
V1401
Load the value in V1400 and V1401 into the accumulator
LDD
4
5
2
6
7
2
9
9
Acc. 4
5
2
6
7
2
9
9
0
2
6
Compared with
C30 OUT 6
7
3
V1411
Handheld Programmer Keystrokes X(IN)
1
LD
SHFT
D
SHFT
V
1
4
0
0
CMP
SHFT
D
SHFT
V
1
4
1
0
STR
SPCL
6
0
OUT
C(CR)
3
0
5
V1410
DL405 User Manual, 4th Edition
Standard RLL Instructions
STR
9
Page 256
5--84
Standard RLL Instructions Accumulator Logic Instructions
The Compare Formatted compares the value in the accumulator with a specified number of discrete locations (1--32). The instruction requires a starting location (Aaaa) and the number of bits (Kbbb) to be compared. The corresponding status flag will be turned on indicating the result of the comparison.
Compare Formatted (CMPF)
430 440 450
DS
HPP
Operand Data Type
CMPF A aaa K bbb
DL440 Range
DL450 Range
A/B aaa bbb aaa bbb
Inputs
X
0--477
----
0--1777
----
Outputs
Y
0--477
----
0--1777
----
Control Relays
C
0--1777
----
0--3777
----
Stage Bits
S
0--1777
----
0--1777
----
Timer Bits
T
0--377
----
0--377
----
Counter Bits
CT
0--177
----
0--377
----
Special Relays
SP
0--137 320--717
----
0--137 320--717
----
Global I/O
GX
0--1777
----
0--2777
----
Constant
K
----
1--32
----
1--32
Discrete Bit Flags
Description
SP60
On when the value in the accumulator is less than the instruction value.
SP61
On when the value in the accumulator is equal to the instruction value.
SP62
On when the value in the accumulator is greater than the instruction value.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example, when X1 is on the Load Formatted instruction loads the binary value (6) from C10--C13 into the accumulator. The CMPF instruction compares the value in the accumulator to the value in Y20--Y23 (E hex). The corresponding discrete status flag will be turned on indicating the result of the comparison. In this example, if the value in the accumulator is less than the value specified in the Compare instruction, SP60 will turn on energizing C30. DirectSOFT X1
LDF
C10 K4
CMPF
Y20 K4
Standard RLL Instructions
SP60
Load the value of the specified discrete locations (C10--C13) into the accumulator
Location
Constant
C10
K4
The unused accumulator bits are set to zero
Compare the value in the accumulator with the value of the specified discrete location (Y20--Y23)
Acc. 0
C30
Y23 Y22 Y21 Y20
OUT
0
0
0
0
Compared with
ON ON ON OFF E
Handheld Programmer Keystrokes STR
X(IN)
1
LD
SHFT
F
SHFT
C
1
0
K(CON)
4
CMP
SHFT
F
SHFT
Y(OUT)
2
0
K(CON)
4
STR
SPCL
6
0
OUT
C(CR)
3
0
DL405 User Manual, 4th Edition
C13 C12 C11 C10 OFF ON ON OFF
0
0
6
Page 257
5--85
Standard RLL Instructions Accumulator Logic Instructions
Compare with Stack (CMPS)
The Compare with Stack instruction is a 32-bit instruction that compares the value in the accumulator with the value in the first level of the accumulator stack.
430 440 450
The corresponding status flag will be turned on indicating the result of the comparison. This does not affect the value in the accumulator.
DS
HPP
CMPS
Discrete Bit Flags
Description
SP60
On when the value in the accumulator is less than the instruction value.
SP61
On when the value in the accumulator is equal to the instruction value.
SP62
On when the value in the accumulator is greater than the instruction value.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example when X1 is on, the value in V1400 and V1401 is loaded into the accumulator using the Load Double instruction. The value in V1410 and V1411 is loaded into the accumulator using the Load Double instruction. The value that was loaded into the accumulator from V1400 and V1401 is placed on top of the stack when the second Load instruction is executed. The value in the accumulator is compared with the value in the first level or the accumulator stack using the CMPS instruction. The corresponding discrete status flag will be turned on indicating the result of the comparison. In this example, if the value in the accumulator is less than the value in the stack, SP60 will turn on, energizing C30. DirectSOFT
V1401
X1
LDD V1400 LDD V1410
SP60
6
5
0
0
3
5
4
4
Load the value in V1410 and V1411 into the accumulator
Acc. 6
5
0
0
3
5
4
4
Compare the value in the accumulator with the value in the first level of the accumulator stack
CMPS
V1400
Load the value in V1400 and V1401 into the accumulator
V1411
C30 OUT
V1410
5
5
0
0
3
5
4
4
Acc. 5
5
0
0
3
5
4
4
Compared with Handheld Programmer Keystrokes
Top of Stack
X(IN)
1
LD
SHFT
D
SHFT
V
1
4
0
0
LD
SHFT
D
SHFT
V
1
4
1
0
CMP
SHFT
S
STR
SPCL
6
0
OUT
C(CR)
3
0
Standard RLL Instructions
STR
DL405 User Manual, 4th Edition
Page 258
5--86
Standard RLL Instructions Accumulator Logic Instructions
Compare Real Number (CMPR)
430 440 450
DS
HPP
The Compare Real Number instruction compares a real number value in the accumulator with two consecutive V-memory locations containing a real number. The corresponding status flag will be turned on indicating the result of the comparison. Both numbers being compared are 32 bits long. Operand Data Type
CMPR A aaa
DL450 Range A aaa
V--memory
V
All (See p. 3--42)
Pointer
P
All (See p. 3--42)
Constant
R
--3.402823E+038 to + --3.402823E+038
Discrete Bit Flags
Description
SP60
On when the value in the accumulator is less than the instruction value.
SP61
On when the value in the accumulator is equal to the instruction value.
SP62
On when the value in the accumulator is greater than the instruction value.
SP71
On anytime the V-memory specified by a pointer (P) is not valid.
SP75
On when a real number instruction is executed and a non--real number was encountered.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example when X1 is on, the LDR instruction loads the real number representation for 7 decimal into the accumulator. The CMPR instruction compares the accumulator contents with the real representation for decimal 6. Since 7 > 6, the corresponding discrete status flag is turned on (special relay SP62). DirectSOFT X1
R7.0
Load the real number representation for decimal 7 into the accumulator.
R6.0
Compare the value with the real number representation for decimal 6.
LDR
CMPR
SP62
C1 OUT
Standard RLL Instructions
Handheld Programmer Keystrokes STR
X(IN)
1
LD
SHFT
D
SHFT
K(CON)
4
0
E
0
0
0
0
0
CMP
SHFT
R
SHFT
K(CON)
4
0
D
0
0
0
0
0
STR
SPCL
6
0
OUT
C(CR)
3
0
DL405 User Manual, 4th Edition
Acc. 4
0
E
0
0
0
0
0
CMPR 4
0
D
0
0
0
0
0
Page 259
Standard RLL Instructions Math Instructions
5--87
Math Instructions Add (ADD)
430 440 450
DS
HPP
Add is a 16 bit instruction that adds a BCD value in the accumulator with a BCD value in a V--memory location (Aaaa). The result resides in the accumulator.
Operand Data Type
ADD A aaa
DL430 Range
DL440 Range
DL450 Range
A aaa aaa aaa
V--memory
V
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Pointer
P
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Discrete Bit Flags
Description
SP63
On when the result of the instruction causes the value in the accumulator to be zero.
SP66
On when the 16 bit addition instruction results in a carry.
SP67
On when the 32 bit addition instruction results in a carry.
SP70
On anytime the value in the accumulator is negative.
SP75
On when a BCD instruction is executed and a NON--BCD number was encountered.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example, when X1 is on, the value in V1400 will be loaded into the accumulator using the Load instruction. The value in the lower 16 bits of the accumulator are added to the value in V1420 using the Add instruction. The value in the accumulator is copied to V1500 using the Out instruction. DirectSOFT
V1400
X1
4
9
3
5
The unused accumulator bits are set to zero 0 0 0 0 4
Load the value in V1400 into the lower 16 bits of the accumulator
LD V1400
Add the value in the lower 16 bits of the accumulator with the value in V1420
ADD V1420
+ Acc.
Copy the value in the lower 16 bits of the accumulator to V1500
OUT V1500
9
3
5
(Accumulator)
2
5
0
0
(V1420)
7
4
3
5
7
4
3
5
V1500
STR
X(IN)
1
LD
V
1
4
0
0
ADD
V
1
4
2
0
OUT
V
1
5
0
0
Standard RLL Instructions
Handheld Programmer Keystrokes
DL405 User Manual, 4th Edition
Page 260
5--88
Standard RLL Instructions Math Instructions
Add Double (ADDD)
430 440 450
DS
HPP
Add Double is a 32 bit instruction that adds the BCD value in the accumulator with a BCD value (Aaaa), which is either two consecutive V--memory locations or an 8--digit (max.) BCD constant. The result resides in the accumulator.
Operand Data Type
ADDD A aaa
DL430 Range
DL440 Range
A aaa aaa
DL450 Range aaa
V--memory
V
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Pointer
P
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Constant
K
0--99999999
0--99999999
0--99999999
Discrete Bit Flags
Description
SP63
On when the result of the instruction causes the value in the accumulator to be zero.
SP66
On when the 16 bit addition instruction results in a carry.
SP67
On when the 32 bit addition instruction results in a carry.
SP70
On anytime the value in the accumulator is negative.
SP75
On when a BCD instruction is executed and a NON--BCD number was encountered.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example, when X1 is on, the value in V1400 and V1401 will be loaded into the accumulator using the Load Double instruction. The value in the accumulator is added with the value in V1420 and V1421 using the Add Double instruction. The value in the accumulator is copied to V1500 and V1501 using the Out Double instruction. DirectSOFT
V1401
X1
6
LDD
7
3
V1400 9
5
0
2
6
V1400 Load the value in V1400 and V1401 into the accumulator ADDD V1420
6
7
3
9
5
0
2
6
(Accumulator)
+ 2
0
0
0
4
0
4
6
(V1421 and V1420)
Acc. 8
7
3
9
9
0
7
2
8
7
3
9
9
0
7
2
Add the value in the accumulator with the value in V1420 and V1421 OUTD
Standard RLL Instructions
V1500
V1501
Copy the value in the accumulator to V1500 and V1501
V1500
Handheld Programmer Keystrokes STR
X(IN)
1
LD
SHFT
D
SHFT
V
1
4
0
0
ADD
SHFT
D
SHFT
V
1
4
2
0
OUT
SHFT
D
SHFT
V
1
5
0
0
DL405 User Manual, 4th Edition
Page 261
5--89
Standard RLL Instructions Math Instructions Add Real is a 32--bit instruction that adds a real number, which is either two consecutive V--memory locations or a 32--bit constant, to a real number in the accumulator. Both numbers must conform to the IEEE floating point format. The result is a 32--bit real number that resides in the accumulator.
Add Real (ADDR)
430 440 450
DS
HPP
Operand Data Type
ADDR A aaa
DL450 Range A aaa
V--memory
V
All (See p. 3--42)
Pointer
P
All V mem (See p. 3--42)
Constant
R
--3.402823E+038 to +3.402823E+038
Discrete Bit Flags
Description
SP63
On when the result of the instruction causes the value in the accumulator to be zero.
SP70
On anytime the value in the accumulator is negative.
SP71
On anytime the V-memory specified by a pointer (P) is not valid.
SP72
On anytime the value in the accumulator is a valid floating point number.
SP73 on when a signed addition or subtraction results in a incorrect sign bit.
SP74
On anytime a floating point math operation results in an underflow error.
SP75
On when a real number instruction is executed and a non-real number was encountered.
NOTE: Status flags are valid only until another instruction uses the same flag. DirectSOFT X1
4
LDR
0
E
0
0
0
0
0
R7.0 Load the real number 7.0 into the accumulator
7 +
4
0
E
0
0
0
0
0
(Accumulator)
1
5
+ 4
1
7
0
0
0
0
0
(ADDR)
2
2
Acc. 4
1
B
0
0
0
0
0
0
0
(decimal)
ADDR R15.0
V1401 4
Add the real number 15.0 to the accumulator contents, which is in real number format.
OUTD V1400 Copy the result in the accumulator to V1400 and V1401.
1
B
V1400 0
0
0
(Hex number)
Real Value 8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Acc. 0
1
0
0
0
0
0
1
1
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Sign Bit
Exponent (8 bits)
1.011 x 2 (exp 4) = 10110. binary= 22 decimal
NOTE: If the value being added to a real number is 16,777,216 times smaller than the real number, the calculation will not work. NOTE: The current HPP does not support real number entry with automatic conversion to the 32-bit IEEE format. You must use DirectSOFT for this feature.
DL405 User Manual, 4th Edition
Standard RLL Instructions
128 + 2 + 1 = 131 131 -- 127 = 4
Mantissa (23 bits)
Page 262
5--90
Standard RLL Instructions Math Instructions
Subtract (SUB)
430 440 450
DS
HPP
Subtract is a 16 bit instruction that subtracts the BCD value (Aaaa) in a V--memory location from the BCD value in the lower 16 bits of the accumulator The result resides in the accumulator.
Operand Data Type
SUB A aaa
DL430 Range
DL440 Range
DL450 Range
A aaa aaa aaa
A aaa aaa aaa
V--memory
V
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Pointer
P
All (See p. 3--40)
All (See p. 3--41)
All (See p. 3--42)
Discrete Bit Flags
Description
SP63
On when the result of the instruction causes the value in the accumulator to be zero.
SP64
On when the 16 bit subtraction instruction results in a borrow.
SP65
On when the 32 bit subtraction instruction results in a borrow.
SP70
On anytime the value in the accumulator is negative.
SP75
On when a BCD instruction is executed and a NON--BCD number was encountered.
NOTE: Status flags are valid only until another instruction uses the same flag. In the following example, when X1 is on, the value in V1400 will be loaded into the accumulator using the Load instruction. The value in V1420 is subtracted from the value in the accumulator using the Subtract instruction. The value in the accumulator is copied to V1500 using the Out instruction. V1400
DirectSOFT X1
2
4
7
5
2
4
7
5
(Accumulator)
1
5
9
2
(V1420)
0
8
8
3
0
8
8
3
LD V1400 Load the value in V1400 into the lower 16 bits of the accumulator
The unused accumulator bits are set to zero 0 0 0 0
SUB y V1420 Acc.
Subtract the value in V1420 from the value in the lower 16 bits of the accumulator OUT V1500
V1500
Standard RLL Instructions
Copy the value in the lower 16 bits of the accumulator to V1500 Handheld Programmer Keystrokes
DL405 User Manual, 4th Edition
STR
X(IN)
1
LD
V
1
4
0
0
SUB
V
1
4
2
0
OUT
V
1
5
0
0