Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 35 of 68

DL405 User Manual: Chapter 5: Standard RLL Instructions, pages 303 to 312

Pages 303 to 312 of 608, from DL405 User Manual

The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AutomationDirect D4-08B-1, AutomationDirect D4-08ND3S, AutomationDirect D4-16TA, PLC Direct D4-16TD2, AutomationDirect D4-32ND3-1, Konnect-It D4-08B-1, Koyo D4-08B-1, Konnect-It D4-08ND3S, and 6 more models

Page 303

Standard RLL Instructions Number Conversion Instructions

Ten’s Complement The Ten’s Complement instruction takes the 10’s complement (BCD) of the 8 digit (BCDCPL) accumulator. The result resides in the accumulator. The calculation for this 430 440 450 instruction is :

100000000 HPP DS -- accumulator value 10’s complement value

5--131

BCDCPL

In the following example when X1 is on, the value in V1400 and V1401 is loaded into the accumulator. The 10’s complement is taken for the 8 digit accumulator using the Ten’s Complement instruction. The value in the accumulator is copied to V1500 and V1501 using the Out Double instruction. DirectSOFT

V1400

V1401

X1

LDD

0

0

0

0

0

0

8

7

Acc. 0

0

0

0

0

0

8

7

Acc. 9

9

9

9

9

9

1

3

9

9

9

9

9

9

1

3

V1400 Load the value in V1400 and V1401 into the accumulator

BCDCPL

Takes a 10’s complement of the value in the accumulator OUTD V1500

V1501

Copy the value in the accumulator to V1500 and V1501

V1500

Handheld Programmer Keystrokes STR

X(IN)

1

LD

SHFT

D

BCD

SHFT

C

P

L

OUT

SHFT

D

SHFT

V

SHFT

V

1

4

0

0

1

5

0

0

NOTE: If your program has a subtraction calculation which results in a borrowed digit (noted by the status flag), the BCDCPL instruction can be used to find the absolute difference between the two values in the subtraction.

Standard RLL Instructions DL405 User Manual, 4th Edition

Page 304

5--132

Standard RLL Instructions Number Conversion Instructions

Binary to Real Conversion (BTOR)

The Binary-to-Real instruction converts a binary value in the accumulator to its equivalent real number (floating point) format. The result resides in the accumulator. Both the binary and the real number may use all 32 bits of the accumulator

430 440 450

DS

HPP

BTOR

NOTE: This instruction will not work for a signed decimal. Discrete Bit Flags

Description

SP63

On when the result of the instruction causes the value in the accumulator to be zero.

SP70

On anytime the value in the accumulator is negative.

In the following example, when X1 is on, the value in V1400 and V1401 is loaded into the accumulator using the Load Double instruction. The BTOR instruction converts the binary value in the accumulator the equivalent real number format. The binary weight of the MSB is converted to the real number exponent by adding it to 127 (decimal). Then the remaining bits are copied to the mantissa as shown. The value in the accumulator is copied to V1500 and V1501 using the Out Double instruction. The handheld programmer would display the binary value in V1500 and V1501 as a HEX value. DirectSOFT

V1401

X1

LDD

V1400

0

0

0

5

7

2

4

1

V1400 Load the value in V1400 and V1401 into the accumulator 8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

Acc. 0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

1

0

1

1

1

0

0

1

0

0

0

1

0

0

0

0

1

1

0

1

0

0

0

0

0

1

0

0

0

0

0

Binary Value

2 (exp 18) 127 + 18 = 145 145 = 128 + 16 + 1 BTOR

Convert the binary value in the accumulator to the real number equivalent format

Acc. 0

Sign Bit

1

0

0

1

0

0

0

1

0

1

0

1

1

1

0

0

Exponent (8 bits)

0

Mantissa (23 bits)

Real Number Format

OUTD

Standard RLL Instructions

V1500 4

Copy the real value in the accumulator to V1500 and V1501

A

V1501

Handheld Programmer Keystrokes STR

X(IN)

1

LD

SHFT

D

SHFT

V

1

SHFT

B

T

O

R

SHFT

OUT

SHFT

D

SHFT

V

1

DL405 User Manual, 4th Edition

8

4

0

0

5

0

0

E

4

8

2

V1500

0

The real number (HEX) value copied to V1500

Page 305

5--133

Standard RLL Instructions Number Conversion Instructions

The Real-to-Binary instruction converts the real number in the accumulator to a binary value. If the real number is negative, it will become a signed decimal. The result resides in the accumulator. Both the binary and the real number may use all 32 bits of the accumulator. Any decimal portion will be truncated.

Real to Binary Conversion (RTOB)

430 440 450

DS

HPP

RTOB

Discrete Bit Flags

Description

SP63

On when the result of the instruction causes the value in the accumulator to be zero.

SP70

On anytime the value in the accumulator is negative.

SP72

On anytime the value in the accumulator is a valid floating point number.

SP73 on when a signed addition or subtraction results in a incorrect sign bit.

SP75

On when a BCD instruction is executed and a NON--BCD number was encountered.

In the following example, when X1 is on, the value in V1400 and V1401 is loaded into the accumulator using the Load Double instruction. The RTOB instruction converts the real value in the accumulator to the equivalent binary number format. The value in the accumulator is copied to V1500 and V1501 using the Out Double instruction. The handheld programmer would display the binary value in V1500 and V1501 as a HEX value. DirectSOFT X1

4

LDD

8

A

E

4

V1401

V1400 Load the value in V1400 and V1401 into the accumulator

Sign Bit

Exponent (8 bits)

Acc. 0

1

0

0

1

0

0

0

1

8

2

0

Real Number Format

V1400

Mantissa (23 bits)

0

1

0

1

1

1

0

0

0

1

0

1

0

0

0

0

0

1

0

0

0

0

0

RTOB

Convert the real number in the accumulator to binary format.

128 + 16 + 1 = 145 127 + 18 = 145 Binary Value

2 (exp 18) 8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

Acc. 0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

1

0

1

1

1

0

0

1

0

0

0

1

0

0

0

0

1

5

7

OUTD V1500 Copy the real value in the accumulator to V1500 and V1501

V1501 0

0

V1500 2

4

1

The binary number copied to V1400.

Handheld Programmer Keystrokes STR

X(IN)

1

LD

SHFT

D

SHFT

V

1

SHFT

R

T

O

B

SHFT

OUT

SHFT

D

SHFT

V

1

4

0

0

5

0

0

DL405 User Manual, 4th Edition

Standard RLL Instructions

0

Page 306

5--134

Standard RLL Instructions Number Conversion Instructions

Radian Real Conversion (RADR)

430 440 450

DS

HPP

Degree Real Conversion (DEGR)

430 440 450

DS

HPP

The Radian Real Conversion instruction converts the real degree value stored in the accumulator to the equivalent real number in radians. The result resides in the accumulator.

RADR

The Degree Real instruction converts the degree real radian value stored inthe accumulator to the equivalent real number in degrees. The result resides in the accumulator.

DEGR

The two instructions described above convert real numbers into the accumulator from degree format to radian format, and visa-versa. In degree format, a circle contains 360 degrees. In radian format, a circle contains 2 Π radians. These convert between both positive and negative real numbers, and for angles greater than a full circle. These functions are very useful when combined with the transcendantal trigonometric functions (see the section on math instructions). Discrete Bit Flags

Description

SP63

On when the result of the instruction causes the value in the accumulator to be zero.

SP70

On anytime the value in the accumulator is negative.

SP71

On anytime the V-memory specified by a pointer (P) is not valid.

SP72

On anytime the value in the accumulator is a valid floating point number.

SP74

On anytime a floating point math operation results in an underflow error.

SP75

On when a BCD instruction is executed and a NON--BCD number was encountered.

NOTE: The current HPP does not support real number entry with automatic conversion to the 32-bit IEEE format. You must use DirectSOFT for entering real numbers, using the LDR (Load Real) instruction. The following example takes the sine of 45 degrees. Since transcendental functions operate only on real numbers, we do a LDR (load real) 45. The trig functions operate only in radians, so we must convert the degrees to radians by using the RADR command. After using the SINR (Sine Real) instruction, we use an OUTD (Out Double) instruction to move the result from the accumulator to V-memory. The result is 32-bits wide, requiring the Out Double to move it. Accumulator contents (viewed as real number)

DirectSOFT X1

LDR

Standard RLL Instructions

R45

45.000000

RADR

Convert the degrees into radians, leaving the result in the accumulator.

0.7358981

SINR

Take the sine of the number in the accumulator, which is in radians.

0.7071067

Copy the value in the accumulator to V2000 and V2001.

0.7071067

OUTD V2000

DL405 User Manual, 4th Edition

Load the real number 45 into the accumulator.

Page 307

Standard RLL Instructions Number Conversion Instructions

ASCII to HEX (ATH)

430 440 450

DS

HPP

5--135

The ASCII TO HEX instruction converts a ATH table of ASCII values to a specified table of V aaa HEX values. ASCII values are two digits and their HEX equivalents are one digit. This means an ASCII table of four V--memory locations would only require two V-memory locations for the equivalent HEX table. The function parameters are loaded into the accumulator stack and the accumulator by two additional instructions. Listed below are the steps necessary to program an ASCII to HEX table function. The example on the following page shows a program for the ASCII to HEX table function. Step 1:, Load the number of V--memory locations for the ASCII table into the first level of the accumulator stack. Step 2:, Load the starting V--memory location for the ASCII table into the accumulator. This parameter must be a HEX value. Step 3:, Specify the starting V--memory location (Vaaa) for the HEX table in the ATH instruction. Helpful Hint:, For parameters that require HEX values when referencing memory locations, the LDA instruction can be used to convert an octal address to the HEX equivalent and load the value into the accumulator. Operand Data Type

V--memory

V

DL440 Range

DL450 Range aaa aaa

All (See p. 3--41)

All (See p. 3--42)

In the example on the following page, when X1 is ON the constant (K4) is loaded into the accumulator using the Load instruction and will be placed in the first level of the accumulator stack when the next Load instruction is executed. The starting location for the ASCII table (V1400) is loaded into the accumulator using the Load Address instruction. The starting location for the HEX table (V1600) is specified in the ASCII to HEX instruction. The table below lists valid ASCII values for ATH conversion. ASCII Values Valid for ATH Conversion Hex Value

ASCII Value

Hex Value

30

0

38

8

31

1

39

9

32

2

41

A

33

3

42

B

34

4

43

C

35

5

44

D

36

6

45

E

37

7

46

F

DL405 User Manual, 4th Edition

Standard RLL Instructions

ASCII Value

Page 308

5--136

Standard RLL Instructions Number Conversion Instructions

DirectSOFT X1

LD K4

33 34

V1400

Convert octal 1400 to HEX 300 and load the value into the accumulator

LDA O 1400

V1401

31 32

V1402

37 38

V1600

Handheld Programmer Keystrokes X(IN)

1

LD

K(CON)

4

LD

SHFT

A

OCT

1

4

0

0

SHFT

A

T

H

SHFT

V

1

6

DS

HPP

V1600

5678

V1601

35 36

V1403

STR

430 440 450

1234

V1600 is the starting location for the HEX table

ATH

HEX to ASCII (HTA)

Hexadecimal Equivalents

ASCII TABLE

Load the constant value into the lower 16 bits of the accumulator. This value defines the number of V memory location in the ASCII table

0

0

The HEX to ASCII instruction converts a table of HEX values to a specified table of ASCII values. HEX values are one digit and their ASCII equivalents are two digits.

HTA V aaa

This means a HEX table of two V--memory locations would require four V--memory locations for the equivalent ASCII table. The function parameters are loaded into the accumulator stack and the accumulator by two additional instructions. Listed below are the steps necessary to program a HEX to ASCII table function. The example on the following page shows a program for the HEX to ASCII table function. Step 1:, Load the number of V--memory locations in the HEX table into the first level of the accumulator stack. Step 2:, Load the starting V--memory location for the HEX table into the accumulator. This parameter must be a HEX value.

Standard RLL Instructions

Step 3:, Specify the starting V--memory location (Vaaa) for the ASCII table in the HTA instruction. Helpful Hint:, For parameters that require HEX values when referencing memory locations, the LDA instruction can be used to convert an octal address to the HEX equivalent and load the value into the accumulator. Operand Data Type

V--memory

DL405 User Manual, 4th Edition

DL440 Range

V

DL440 Range aaa aaa

All (See p. 3--41)

All (See p. 3--42)

Page 309

Standard RLL Instructions Number Conversion Instructions

5--137

In the following example, when X1 is ON the constant (K2) is loaded into the accumulator using the Load instruction. The starting location for the HEX table (V1500) is loaded into the accumulator using the Load Address instruction. The starting location for the ASCII table (V1400) is specified in the HEX to ASCII instruction. DirectSOFT X1

Hexadecimal Equivalents

LD

ASCII TABLE

K2 Load the constant value into the lower 16 bits of the accumulator. This value defines the number of V locations in the HEX table.

33 34

V1400

31 32

V1401

37 38

V1402

35 36

V1403

1234

V1500 LDA O 1500 Convert octal 1500 to HEX 340 and load the value into the accumulator

HTA V1400

5678

V1501

V1400 is the starting location for the ASCII table. The conversion is executed by this instruction. Handheld Programmer Keystrokes STR

X(IN)

1

LD

K(CON)

2

LD

SHFT

A

OCT

1

5

0

0

SHFT

H

T

A

SHFT

V

1

4

0

0

The table below lists valid ASCII values for HTA conversion. ASCII Values Valid for HTA Conversion ASCII Value

Hex Value

ASCII Value

0

30

8

38

1

31

9

39

2

32

A

41

3

33

B

42

4

34

C

43

5

35

D

44

6

36

E

45

7

37

F

46

DL405 User Manual, 4th Edition

Standard RLL Instructions

Hex Value

Page 310

5--138

Standard RLL Instructions Number Conversion Instructions

The BCD/Segment instruction converts a four digit HEX value in the accumulator to seven segment display format. The result resides in the accumulator.

Segment (SEG)

430 440 450

DS

HPP

SEG

In the following example, when X1 is on, the value in V1400 is loaded into the lower 16 bits of the accumulator using the Load instruction. The binary (HEX) value in the accumulator is converted to seven segment format using the Segment instruction. The bit pattern in the accumulator is copied to Y20--Y57 using the Out Formatted instruction. DirectSOFT

V1400

X1

6

LD

F

7

1

V1400 Load the value in V1400 into the lower 16 bits of the accumulator Acc.

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6 5

4 3

2

1

0

0

1

1

0

1

1

0

0

0

1

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6 5

4 3

2

1

0

0

1

1

1

1

1

0

1

0

1

1

1

0

0

0

1

0

0

0

0

0

1

1

1

0

0

0

0

0

1

1

0

-- g f e d c b a

-- g f e d c b a

-- g f e d c b a

-- g f e d c b a Segment Labels

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0

1

1

1

SEG

Convert the binary (HEX) value in the accumulator to seven segment display format

OUTF

Y20 K32

Copy the value in the accumulator to Y20--Y57

Acc.

a f b

Segment Labels

Y57 Y56 Y55 Y54 Y53 g e

OFF ON ON ON ON

S S

S S

S S c d

Standard RLL Instructions

Handheld Programmer Keystrokes STR

X(IN)

1

LD

SHFT

V

SHFT

S

E

G

OUT

SHFT

F

SHFT

1

4

0

0

Y(OUT)

2

0

DL405 User Manual, 4th Edition

K(CON)

3

2

S S

Y24 Y23 Y22 Y21 Y20 OFF OFF ON ON OFF

Page 311

5--139

Standard RLL Instructions Number Conversion Instructions

The Gray code instruction converts a 16 bit gray code value to a BCD value. The BCD conversion requires 10 bits of the accumulator. The upper 22 bits are set to “0”. This instruction is designed for use with devices (typically encoders) that use the grey code numbering scheme. The Gray Code instruction will directly convert a gray code number to a BCD number for devices having a resolution of 512 or 1024 counts per revolution. If a device having a resolution of 360 counts per revolution is to be used you must subtract a BCD value of 76 from the converted value to obtain the proper result. For a device having a resolution of 720 counts per revolution you must subtract a BCD value of 152.

Gray Code (GRAY)

430 440 450

DS

HPP

GRAY

In the following example, when X1 is ON the binary value represented by X10--X27 is loaded into the accumulator using the Load Formatted instruction. The gray code value in the accumulator is converted to BCD using the Gray Code instruction. The value in the lower 16 bits of the accumulator is copied to V1500. DirectSOFT

X27 X26 X25

X1

LDF

S S

OFF OFF OFF

X10

X12 X11 X10

S S

ON OFF ON

K16 Load the value represented by X10--X27 into the lower 16 bits of the accumulator Acc.

GRAY Acc.

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6 5

4 3

2

1

0

0

0

0

0

0

0

0

1

0

1

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6 5

4 3

2

1

0

0

0

0

0

0

0

1

1

0

0

0

0

6

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Convert the 16 bit grey code value in the accumulator to a BCD value OUT V1500

V1500

Copy the value in the lower 16 bits of the accumulator to V1500

Handheld Programmer Keystrokes STR

X(IN)

1

LD

SHFT

F

SHFT

X(IN)

1

G

R

A

Y

SHFT

OUT

V

1

5

0

0

K(CON)

1

6

BCD

0000000000

0000

0000000001

0001

0000000011

0002

0000000010

0003

0000000110

0004

0000000111

0005

0000000101

0006

0000000100

0007

S S

S S

S

S

1000000001

1022

1000000000

1023

DL405 User Manual, 4th Edition

Standard RLL Instructions

SHFT

0

Gray Code

Page 312

5--140

Standard RLL Instructions Number Conversion Instructions

Shuffle Digits (SFLDGT)

430 440 450

DS

HPP

The Shuffle Digits instruction shuffles a maximum of 8 digits rearranging them in a specified order. This function requires parameters to be loaded into the first level of the accumulator stack and the accumulator with two additional instructions. Listed below are the steps necessary to use the shuffle digit function. The example on the following page shows a program for the Shuffle Digits function.

SFLDGT

Step 1: - Load the value (digits) to be shuffled into the first level of the accumulator stack. Step 2: - Load the order the digits will be shuffled to into the accumulator, numbered 1 through 8 (“1” being the least significant digit, and “8” being the most significant digit. Note: - If the number used to specify the order contains a 0 or 9--F, the corresponding position will be set to 0. See example Note: - If the number used to specify the order contains duplicate numbers, the most significant duplicate number is valid. The result resides in the accumulator. See example Step 3: - Insert the SFLDGT instruction. Shuffle Digits Block Diagram

There are a maximum of 8 digits that can be shuffled. The bit positions in the first level of the accumulator stack defines the digits to be shuffled. They correspond to the bit positions in the accumulator that define the order the digits will be shuffled. The digits are shuffled and the result resides in the accumulator.

Digits to be shuffled (first stack location) 9

A

B

C D

E

F

0

1

2

8

7

6

5

4

3

Specified order (accumulator) Bit Positions

8

7

6

5

4

3

2

1

B

C

E

F

0

D

A

9

Standard RLL Instructions

Result (accumulator)

DL405 User Manual, 4th Edition