Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 62 of 68

DL405 User Manual: Appendix C: Instruction Execution Times, pages 553 to 560

Pages 553 to 560 of 608, from DL405 User Manual

The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AutomationDirect D4-08B-1, AutomationDirect D4-08ND3S, AutomationDirect D4-16TA, PLC Direct D4-16TD2, AutomationDirect D4-32ND3-1, Konnect-It D4-08B-1, Koyo D4-08B-1, Konnect-It D4-08ND3S, and 6 more models

Page 553

Instruction Execution Times

1C

In This Appendix. . . ., Introduction, Boolean Instructions, Comparative Boolean Instructions, Immediate Instructions, Clock/Calendar Instructions, Timer, Counter, and Shift Register Instructions, Accumulator/Data Stack Load and Output Instructions, Accumulator Logic Instructions, Bit Operation Instructions, Math Instructions, Number Conversion Instructions, Table Instructions, CPU Control Instructions, Program Control Instructions, Interrupt Instructions, RLL PLUS Instructions, Intelligent I/O Instructions, Network Instructions, Message Instructions, Drum Instructions

Page 554

Appendix A DL405 Error Codes

C--2

Instruction Execution Times

Introduction

Appendix C Inst. Execution Times

Appendix B DL405 Error Codes

V-Memory Data Registers

This appendix contains several tables that provide the instruction execution times for the DL430, DL440, and DL450 CPUs. Many execution times depend on the type of data used with the instruction. Registers are classified into the following types: S Data (word) Registers S Bit Registers Some V-memory locations are considered data registers, such as timer or counter current values. Standard User V-memory is classified as a V-memory data register. Note that can load a bit pattern into these types of registers, even though their primary use is for data registers. The following locations are data registers: Data Registers

V-Memory Bit Registers

DL440

DL450

Timer Current Values

V00000 -- V 00177

V00000 -- V00377

V00000 -- V00377

Counter Current Values

V01000 -- V01177

V01000 -- V01177

V01000 -- V01377

User Data Words

V1400 -- V7377

V1400 -- V7377 V10000 -- V17777

V1400 -- V7377 V10000 -- V37777

You may recall some of the discrete points such as X, Y, C, etc. are automatically mapped into V--memory. The following bit registers contain this data: Bit Registers

How to Read the Tables

DL430

DL430

DL440

DL450

Input Points (X)

V40400 -- V 40423

V40400 -- V 40423

V40400 -- V 40477

Output Points (Y)

V40500 -- V40523

V40500 -- V40523

V40500 -- V40577

Control Relays (C)

V40600 -- V40635

V40600 -- V40677

V40600 -- V40777

Timer Status Bits

V41100 -- V41107

V41100 -- V41117

V41100 -- V41117

Counter Status Bits

V41140 -- V41147

V41140 -- V41147

V41140 -- V41157

Stages

V41000 -- V41027

V41000 -- V41077

V41000 -- V41077

Remote I/O, (Global GX) (Global GY)

V40000 -- V40037

V40000 -- V40077

V40000 -- V40177 V40200 -- V40377

Some instructions can have more than one parameter. For example, the SET instruction shown in the ladder program to the right can set a single point or a range of points.

Range Available X0

X1

Y0 -- Y7 SET

C0

In these cases, execution times depend on the amount and type of parameters. The execution time tables list execution times for various situations, as shown below: SET RST

DL405 User Manual, 4th Edition

1st #:

X, Y, C, S, GX, GY

2nd #:

X, Y, C, S, GX, GY (N pt) 13.0μs+7.8μsxN

1st #:

X, Y, C, S, GX, GY

2nd #:

X, Y, C, S, GX, GY (N pt) 11.7μs+7.8μsxN

20.8 μs 19.5 μs

Execution depends on numbers of locations and types of data used

Page 555

C--3

Instruction Execution Times

Boolean Instructions Boolean Instructions Instruction

STRN STRB STRNB

ORN ORB ORNB AND ANDN ANDB ANDNB

DL450

Execute

Not Exe.

Execute

Not Exe.

Execute

Not Exe.

X, Y, C, T, CT

4.7 μs

4.7 μs

0.33 μs

0.33 μs

0.96 μs

0.96 μs

S, SP, GX, GY

4.7 μs

4.7 μs

8.0 μs

8.0 μs

1.0 μs

1.0 μs

X, Y, C, T, CT

5.7 μs

5.7 μs

0.33 μs

0.33 μs

1.0 μs

1.0 μs

S, SP, GX, GY

5.7 μs

5.7 μs

8.0 μs

8.0 μs

1.0 μs

1.0 μs

V:Register (Bit), - - - 5.0 μs

??? μs

P:Indirect (Bit), - - - 15.3 μs

??? μs

V:Register (Bit), - - - 4.9 μs

??? μs

P:Indirect (Bit), - - - 15.1 μs

??? μs

X, Y, C, T, CT

3.1 μs

3.1 μs

0.33 μs

0.33 μs

0.9 μs

0.9 μs

S, SP, GX, GY

3.1 μs

3.1 μs

4.24 μs

4.24 μs

0.9 μs

0.9 μs

X, Y, C, CT

4.1 μs

4.1 μs

0.33 μs

0.33 μs

0.96 μs

0.96 μs

S, SP, GX, GY

4.1 μs

4.1 μs

4.67 μs

4.67 μs

0.96 μs

0.96 μs

V:Register (Bit), - - - 4.7 μs

??? μs

P:Indirect (Bit), - - - 15.0 μs

??? μs

V:Register (Bit), - - - 4.6 μs

??? μs

P:Indirect (Bit), - - - 14.8 μs

??? μs

X, Y, C, T, CT

2.4 μs

2.4 μs

0.33 μs

0.33 μs

0.8 μs

0.8 μs

S, SP, GX, GY

2.4 μs

2.4 μs

2.72 μs

2.72 μs

0.8 μs

0.8 μs

X, Y, C, T, CT

3.4 μs

3.4 μs

0.33 μs

0.33 μs

0.9 μs

0.9 μs

S, SP, GX, GY

3.4 μs

3.4 μs

3.14 μs

3.14 μs

0.9 μs

0.9 μs

V:Register (Bit), - - - 4.6 μs

??? μs

P:Indirect (Bit), - - - 14.8 μs

??? μs

V:Register (Bit), - - - 4.4 μs

??? μs

P:Indirect (Bit), - - - 14.7 μs

??? μs

ANDSTR

None

1.8 μs

1.8 μs

0.33 μs

0.33 μs

0.5 μs

0.5 μs

ORSTR

None

1.8 μs

1.8 μs

0.33 μs

0.33 μs

0.5 μs

0.5 μs

OUT

X, Y, C

6.7 μs

6.7 μs

0.33 μs

0.33 μs

2.9 μs

2.9 μs

GX, GY

6.7 μs

6.7 μs

2.06 μs

2.06 μs

2.9 μs

2.9 μs

V:Register (Bit), - - - 5.6 μs

??? μs

P:Indirect (Bit), - - - 16.4 μs

??? μs

OROUT

X, Y, C, GX, GY

8.3 μs

8.3 μs

6.1 μs

6.1 μs

3.4 μs

3.4 μs

NOT

None, - 3.2 μs, ??? μs, OUTB

DL405 User Manual, 4th Edition

Appendix C Inst. Execution Codes

OR

DL440

Appendix B DL405 Error Codes

STR

Legal Data Types

DL430

Appendix A DL405 Error Codes

NOTE: The GY data type listed for some instructions throughout this appendices is valid only for the DL450 CPU, which uses both GX and GY data types for Remote I/O points. The DL430 and DL440 CPUs use the GX data type for any Remote I/O points.

Page 556

Appendix C Inst. Execution Times

Appendix B DL405 Error Codes

Appendix A DL405 Error Codes

C--4

Instruction Execution Times

Boolean Instructions Instruction

Legal Data Types

DL430

DL440

DL450

Execute

Not Exe.

Execute

Not Exe.

Execute

Not Exe.

15.1 μs

15.1 μs

8.5 μs

8.5 μs

10.0 μs

10.0 μs

PD

X, Y, C

STRPD

X, Y, C, T, CT, S, SP, GX, GY, - - - 3.7 μs

3.7 μs

STRND

X, Y, C, T, CT, S, SP, GX, GY, - - - 2.8 μs

2.8 μs

ANDPD

X, Y, C, T, CT, S, SP, GX, GY, - - - 3.6 μs

3.6 μs

ANDND

X, Y, C, T, CT, S, SP, GX, GY, - - - 2.7 μs

2.7 μs

ORPD

X, Y, C, T, CT, S, SP, GX, GY, - - - 3.6 μs

3.6 μs

ORND

X, Y, C, T, CT, S, SP, GX, GY, - - - 2.7 μs

2.7 μs

SET

1st #:

X, Y, C

20.8 μs

5.2 μs

0.33 μs

0.33 μs

5.6 μs

1.0 μs

S, GX, GY

20.8 μs

5.2 μs

14.6 μs

5.4 μs

5.6 μs

1.0 μs

X, Y, C, S, GX (N pt)

13.0 μs+ 7.8μsxN

5.2 μs

8.9 μs+ 5.7μsxN

5.4 μs

7.6 μs+ 0.6μsxN

1.2 μs

V:Register (Bit), - - - 10.5 μs

2.3 μs

P:Indirect (Bit), - - - 22.2 μs

13.8 μs

X, Y, C

19.5 μs

5.2 μs

0.33 μs

0.33 μs

5.6 μs

1.0 μs

S, GX, GY

19.5 μs

5.2 μs

13.7 μs

4.5 μs

5.6 μs

5.6 μs

2nd #: (N pt)

X, Y, C, S, GX, GY

11.7 μs+ 7.8μsxN

5.2 μs

8.0 μs+ 5.7μsxN

4.5 μs

7.6 μs+ 0.6μsxN

1.2 μs

1st #:

T, CT

28.2 μs

5.2 μs

15.2 μs

3.8 μs

10.2 μs

0.9 μs

2nd #:

T, CT (N pt)

23.3 μs+ 5.8μsxN

5.2 μs

10.7 μs+ 4.6μsxN

3.8 μs

6.1 μs+ 1.9μsxN

1.2 μs

V:Register (Bit), - - - 10.5 μs

2.3 μs

P:Indirect (Bit), - - - 22.2 μs

13.8 μs

1wd: Y

24.0 μs

24.0 μs

14.7 μs

14.7 μs

7.4 μs

7.5 μs

2wd: Y (N points)

18 μs+ 6μs x N

18μs+ 6μs x N

11μs+ 4μs x N

11μs+ 4μs x N

14.6μs+ 0.32μs xN

14.6μs+ 0.3μs x N

2nd #: SETB RST

RSTB PAUSE

1st #:

DL405 User Manual, 4th Edition

Page 557

C--5

Instruction Execution Times

Comparative Boolean (cont.) Instruction STRE

DL440

DL450

Execute

Not Execute

Execute

Not Execute

Execute

Not Execute

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

61 μs 182 μs 75 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 69 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 4.9 3.5 9.9 9.9

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

182 μs 300 μs 193 μs, - 13.5 μs 13.5 μs 13.5 μs, - 130 μs 206 μs 206 μs 252 μs 347 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 4.9 3.5 9.9 9.9

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 174 μs 248 μs 182 μs 296 μs 387 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

3.4 μs 3.4 μs 8.3 μs 14.3 μs 14.3 μs

9.9 9.9 8.3 14.3 14.3

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 265 μs 341 μs 276 μs 387 μs 480 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

3.4 μs 3.4 μs 8.3 μs 14.3 μs 14.3 μs

9.9 9.9 8.3 14.3 14.3

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

63 μs 180 μs 77 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 69 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 4.9 3.5 9.9 9.9

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

180 μs 298 μs 195 μs, - 13.5 μs 13.5 μs 13.5 μs, - 130 μs 206 μs 206 μs 252 μs 347 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 4.9 3.5 9.9 9.9

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 174 μs 248 μs 182 μs 296 μs 387 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

3.4 μs 3.4 μs 8.3 μs 14.3 μs 14.3 μs

9.9 9.9 8.3 14.3 14.3

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 265 μs 341 μs 276 μs 387 μs 480 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

3.4 μs 3.4 μs 8.3 μs 14.3 μs 14.3 μs

9.9 9.9 8.3 14.3 14.3

DL405 User Manual, 4th Edition

Appendix C Inst. Execution Codes

1st

Appendix B DL405 Error Codes

STRNE

Legal Data Types

DL430

Appendix A DL405 Error Codes

Comparative Boolean Instructions

Page 558

Instruction Execution Times

Comparative Boolean (cont.) Instruction ORE

Appendix C Inst. Execution Times

Appendix B DL405 Error Codes

Appendix A DL405 Error Codes

C--6

ORNE

Legal Data Types

DL430

DL440

DL450

Execute

Not Execute

Execute

Not Execute

Execute

Not Execute

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

62 μs 180 μs 73 μs, - 11.0 μs 11.0 μs 11.0 μs, - 48 μs 122 μs 55 μs 170 μs 262 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

180 μs 297 μs 191 μs, - 11.0 μs 11.0 μs 11.0 μs, - 122 μs 198 μs 131 μs 244 μs 340 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 166 μs 240 μs 175 μs 288 μs 379 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 257 μs 333 μs 268 μs 380 μs 473 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

62 μs 178 μs 75 μs, - 11.0 μs 11.0 μs 11.0 μs, - 48 μs 122 μs 55 μs 170 μs 262 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

178 μs 296 μs 192 μs, - 11.0 μs 11.0 μs 11.0 μs, - 122 μs 198 μs 131 μs 244 μs 340 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 166 μs 240 μs 175 μs 288 μs 379 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 257 μs 333 μs 268 μs 380 μs 473 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

DL405 User Manual, 4th Edition

Page 559

C--7

Instruction Execution Times

Instruction ANDE

DL440

DL450

Execute

Not Execute

Execute

Not Execute

Execute

Not Execute

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

60 μs 178 μs 74 μs, - 11.0 μs 11.0 μs 11.0 μs, - 48 μs 122 μs 55 μs 170 μs 262 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

178 μs 296 μs 192 μs, - 11.0 μs 11.0 μs 11.0 μs, - 122 μs 198 μs 131 μs 244 μs 340 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 166 μs 240 μs 175 μs 288 μs 379 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 257 μs 333 μs 268 μs 380 μs 473 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

62 μs 179 μs 73 μs, - 11.0 μs 11.0 μs 11.0 μs, - 48 μs 122 μs 55 μs 170 μs 262 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

179 μs 297 μs 191 μs, - 11.0 μs 11.0 μs 11.0 μs, - 122 μs 198 μs 131 μs 244 μs 340 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

4.9 μs 4.9 μs 3.5 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 166 μs 240 μs 175 μs 288 μs 379 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 257 μs 333 μs 268 μs 380 μs 473 μs

10.8 μs 10.8 μs 10.8 μs 10.8 μs 10.8 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

DL405 User Manual, 4th Edition

Appendix C Inst. Execution Codes

1st

Appendix B DL405 Error Codes

ANDNE

Legal Data Types

DL430

Appendix A DL405 Error Codes

Comparative Boolean (cont.)

Page 560

Instruction Execution Times

Comparative Boolean (cont.) Instruction STR

Appendix C Inst. Execution Times

Appendix B DL405 Error Codes

Appendix A DL405 Error Codes

C--8

STRN

Legal Data Types

DL430

DL440

DL450

Execute

Not Exe.

Execute

Not Exe.

Execute

Not Exe.

65 μs 182 μs 75 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 63 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

1st

2nd

T, CT

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

66 μs 184 μs 79 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 63 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

184 μs 800 μs 193 μs, - 13.5 μs 13.5 μs 13.5 μs, - 130 μs 206 μs 139 μs 252 μs 347 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 174 μs 248 μs 182 μs 296 μs 387 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 265 μs 341 μs 276 μs 387 μs 480 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

1st

2nd

T, CT

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

65 μs 180 μs 75 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 63 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

1st

2nd

V: Data Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

65 μs 180 μs 77 μs, - 13.5 μs 13.5 μs 13.5 μs, - 56 μs 130 μs 63 μs 178 μs 270 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

180 μs 298 μs 195 μs, - 13.5 μs 13.5 μs 13.5 μs, - 130 μs 206 μs 139 μs 252 μs 347 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

4.8 μs 4.8 μs 3.4 μs 9.9 μs 9.9 μs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 174 μs 248 μs 182 μs 296 μs 387 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit), - - - - - - - - - 265 μs 341 μs 276 μs 387 μs 480 μs

12.2 μs 12.2 μs 12.2 μs 12.2 μs 12.2 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

9.9 μs 9.9 μs 8.3 μs 14.3 μs 14.3 μs

DL405 User Manual, 4th Edition