The text of a manual ยท part 65 of 68
DL405 User Manual: Appendix D: Special Relays
Pages 575 to 578 of 608, from DL405 User Manual
The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AutomationDirect D4-08B-1, AutomationDirect D4-08ND3S, AutomationDirect D4-16TA, PLC Direct D4-16TD2, AutomationDirect D4-32ND3-1, Konnect-It D4-08B-1, Koyo D4-08B-1, Konnect-It D4-08ND3S, and 6 more models
Page 575
Special Relays
In This Appendix. . . ., Startup and Real-time Special Relays, CPU Status Relays, System Monitoring Relays, Accumulator Status Relays, Communication Monitoring Relays
1D
Page 576
AppendixDD Appendix DL405 Special Relays Special Relays
Appendix C Special Relays
Appendix B DL405 Error Codes
Appendix A DL405 Error Codes
D--2
Special Relays
Startup and Real-time Special Relays First scan on for the first scan after a power cycle or program to run transition, and is reset to off on the second scan. It is useful when a function needs to be performed only at startup.
SP1
Always ON provides a contact to insure a instruction is executed every scan.
SP2
Always OFF provides a contact that is always off.
SP3
1 minute on for 30 seconds and off for 30 seconds.
SP4
1 second on for 0.5 second and off for 0.5 second.
SP5
100 millisecond on for 50 ms. and off for 50 ms.
SP6
50 millisecond on for 25 ms. and off for 25 ms.
SP7
Alternate scan on every other scan.
SP0
CPU Status Relays SP11
Forced run mode on anytime the CPU keyswitch is in the RUN position.
SP12
Terminal run mode on when the CPU keyswitch is in the TERM position and the CPU is in the run mode.
SP13
Test run mode on when the CPU is in the test run mode.
SP14
Break relay 1 on when the BREAK instruction is executed. It is off when the CPU is in any other mode.
SP15
Test program mode on when the CPU is in the test program mode.
SP16
Terminal PGM mode on when the CPU keyswitch is in the TERM position and the CPU is in program mode.
SP17
Forced stop mode on anytime the CPU keyswitch is in the STOP position.
Break relay 2 on when the BREAK instruction is executed. It is off only when the CPU mode is changed to RUN.
SP22
Interrupt enabled on when hardware interrupts are enabled using the ENI instruction.
SP25
CPU battery disabled on when the CPU battery is disabled by dipswitch 1 on the rear of the CPU.
SP26
I/O update disable
(DL440/DL450) turned on by the application program, thus freezing the state of the I/O.
SP27
Selective I/O update disable
(DL440/DL450) relay can be turned on by the application program. If turned on the I/O update is frozen at last state, for I/O modules sensing a missing terminal block .
SP30
Dipswitch 1 status
(DL430/DL440) follows the On/Off status of dipswitch 1 on the rear of the CPU.
SP31
Dipswitch 2 status
(DL430/DL440) follows the On/Off status of dipswitch 2 on the rear of the CPU.
SP32
Dipswitch 3 status
(DL430/DL440) follows the On/Off status of dipswitch 3 on the rear of the CPU.
SP33
Dipswitch 4 status
(DL430/DL440) follows the On/Off status of dipswitch 4 on the rear of the CPU.
Scan control error
(DL450) this relay will be on if the actual scan time is in excess of the scan time set in fixed or limit scan modes. The relay contact may be useful in program error recovery.
SP21
SP37
DL405 User Manual, 4th Edition
Page 577
Special Relays
D--3 on when a critical error such as I/O communication loss has occurred.
SP41
Warning on when a non critical error such as a low battery has occurred.
SP43
Battery low (440/450)
on when either the memory cartridge battery or the CPU battery is low. Once detected, check V7757 for the exact error code.
SP44
Program memory error on when a memory error such as a memory parity error or a failed memory cartridge has occurred.
SP45
I/O error on when a I/O error such as blown fuse or 24V bad has occurred.
SP46
Communications error on when a communications error has occurred on any of the CPU ports.
I/O configuration error on if a I/O configuration error has occurred. The I/O configuration check must be set on in the CPU before this relay will be functional.
SP50
FAULT instruction on when a FAULT Instruction is executed.
SP51
Math timeout relay on if the CPU time out on a math function.
Grammatical error on if a grammatical error has occurred either while the CPU is running or if the syntax check is run. Once detected check V7755 for a exact error code.
SP53
Math/Table pointer on if there is math execution error or a table pointer error.
SP54
Communication error on when RX, WX, RD, WT instructions are executed with the wrong parameters.
SP56
Table instruction overrun on if a table instruction with a pointer is executed and the pointer value is outside the table boundary.
SP47
SP52
Accumulator Status Relays Math/Table pointer error on if there is math execution error or a table pointer error.
SP60
Value less than on when the value in the accumulator is less than the instruction value.
SP61
Value equal to on when the value in the accumulator is equal to the instruction value.
SP62
Value greater than on when the value in the accumulator is greater than the instruction value.
SP63
Zero on when the result of the instruction causes the value in the accumulator to be zero.
SP64
Half borrow on when the 16 bit subtraction instruction results in a borrow.
SP65
Borrow on when the 32 bit subtraction instruction results in a borrow.
SP66
Half carry on when the 16 bit addition instruction results in a carry.
SP67
Carry when the 32 bit addition instruction results in a carry.
SP70
Sign (negative)
on anytime the value in the accumulator is negative.
SP71
Pointer reference error on when the V-memory specified by a pointer (P) is not valid.
SP72
Floating point
(DL450) on when the numerical value in the accumulator is a floating point number.
SP73
Overflow on when a signed addition or subtraction results in an incorrect sign bit.
SP74
Under flow
(DL450) on when a floating point math operation results in an underflow error.
SP75
Data error on when a BCD instruction is executed and a NON--BCD number was encountered.
SP76
Load zero on when the value loaded into the accumulator by any instruction is zero.
DL405 User Manual, 4th Edition
Appendix AppendixDD DL405 Special Relays Special Relays
SP53
Appendix C Special Relays
Critical error
Appendix B DL405 Error Codes
SP40
Appendix A DL405 Error Codes
System Monitoring Relays
Page 578
AppendixDD Appendix DL405 Special Relays Special Relays
Appendix C Special Relays
Appendix B DL405 Error Codes
Appendix A DL405 Error Codes
D--4
Special Relays
Communication Monitoring Relays The Communications Monitoring Relays are numbered in pairs corresponding to CPU port numbers or slot positions in a base. The two relay types are: S Module/port busy -- on when the port or the communication module in the referenced slot and base is busy transmitting or receiving. You must use this relay with RX and WX instructions to prevent attempting to execute a RX or WX while the module is busy. S Communication error -- on when a communications error occurs. This error automatically clears when another RX or WX instruction executes. DL450 CPU only All DL405 CPUs
Local Base
SP112
CPU port busy Port 1
SP114
CPU port busy Port 2
SP116
CPU port busy Port 3
SP113
Comm error Port 1
SP115
Comm error Port 2
SP117
Comm error Port 3
Expansion Base #1
Expansion Base #2
Expansion Base #3
SP120
Module busy Slot 0
SP140
Module busy Slot 0
SP160
Module busy Slot 0
SP200
Module busy Slot 0
SP121
Comm error Slot 0
SP141
Comm error Slot 0
SP161
Comm error Slot 0
SP201
Comm error Slot 0
SP122
Module busy Slot 1
SP142
Module busy Slot 1
SP162
Module busy Slot 1
SP202
Module busy Slot 1
SP123
Comm error Slot 1
SP143
Comm error Slot 1
SP163
Comm error Slot 1
SP203
Comm error Slot 1
SP124
Module busy Slot 2
SP144
Module busy Slot 2
SP164
Module busy Slot 2
SP204
Module busy Slot 2
SP125
Comm error Slot 2
SP145
Comm error Slot 2
SP165
Comm error Slot 2
SP205
Comm error Slot 2
SP126
Module busy Slot 3
SP146
Module busy Slot 3
SP166
Module busy Slot 3
SP206
Module busy Slot 3
SP127
Comm error Slot 3
SP147
Comm error Slot 3
SP167
Comm error Slot 3
SP207
Comm error Slot 3
SP130
Module busy Slot 4
SP150
Module busy Slot 4
SP170
Module busy Slot 4
SP210
Module busy Slot 4
SP131
Comm error Slot 4
SP151
Comm error Slot 4
SP171
Comm error Slot 4
SP211
Comm error Slot 4
SP132
Module busy Slot 5
SP152
Module busy Slot 5
SP172
Module busy Slot 5
SP212
Module busy Slot 5
SP133
Comm error Slot 5
SP153
Comm error Slot 5
SP173
Comm error Slot 5
SP213
Comm error Slot 5
SP134
Module busy Slot 6
SP154
Module busy Slot 6
SP174
Module busy Slot 6
SP214
Module busy Slot 6
SP135
Comm error Slot 6
SP155
Comm error Slot 6
SP175
Comm error Slot 6
SP215
Comm error Slot 6
SP136 SP137
Module busy Slot 7 Comm error Slot 7
DL405 User Manual, 4th Edition
SP156 SP157
Module busy Slot 7 Comm error Slot 7
SP176 SP177
Module busy Slot 7 Comm error Slot 7
SP216 SP217
Module busy Slot 7 Comm error Slot 7