Page 583
ASCII Table
In This Appendix. . . ., ASCII Conversion Table
1G
Page 584
Appendix G ASCII Table
G--2
ASCII Table
DECIMAL TO HEX TO ASCII CONVERTER DEC
HEX
ASCII
DEC
HEX
ASCII
DEC
HEX
ASCII
DEC
HEX
ASCII
0
00
NUL
32
20 space
64
40
@
96
60
‘
1
01
SOH
33
21
!
65
41
A
97
61 a
2
02
STX
34
22
“
66
42
B
98
62 b
3
03
ETX
35
23
#
67
43
C
99
63 c
4
04
EOT
36
24
$
68
44
D
100
64 d
5
05
ENQ
37
25
%
69
45
E
101
65 e
6
06
ACK
38
26
&
70
46
F
102
66 f
7
07
BEL
39
27
’
71
47
G
103
67 g
8
08
BS
40
28
(
72
48
H
104
68 h
9
09
TAB
41
29
)
73
49
I
105
69 i
10
0A
LF
42
2A
*
74
4A
J
106
6A j
11
0B
VT
43
2B
+
75
4B
K
107
6B k
12
0C
FF
44
2C
,
76
4C
L
108
6C l
13
0D
CR
45
2D
--
77
4D
M
109
6D m
14
0E
SO
46
2E
.
78
4E
N
110
6E n
15
0F
SI
47
2F
/
79
4F
O
111
6F o
16
10
DLE
48
30
0
80
50
P
112
70 p
17
11
DC1
49
31
1
81
51
Q
113
71 q
18
12
DC2
50
32
2
82
52
R
114
72 r
19
13
DC3
51
33
3
83
53
S
115
73 s
20
14
DC4
52
34
4
84
54
T
116
74 t
21
15
NAK
53
35
5
85
55
U
117
75 u
22
16
SYN
54
36
6
86
56
V
118
76 v
23
17
ETB
55
37
7
87
57
W
119
77 w
24
18
CAN
56
38
8
88
58
X
120
78 x
25
19
EM
57
39
9
89
59
Y
121
79 y
26
1A
SUB
58
3A
:
90
5A
Z
122
7A z
27
1B
ESC
59
3B
;
91
5B
[
123
7B
{
28
1C
FS
60
3C
<
92
5C
\
124
7C
|
29
1D
GS
61
3D
=
93
5D
]
125
7D
}
30
1E
RS
62
3E
>
94
5E
^
126
7E
~
31
1F
US
63
3F
?
95
5F
_
127
7F
DEL
DL405 User Manual, 4th Edition
Page 585
Numbering Systems
1H
In This Appendix. . . ., Introduction, Binary Numbering System, Hexadecimal Numbering System, Octal Numbering System, Binary Coded Decimal (BCD) Numbering System, Real (Floating Point) Numbering System, BCD/Binary/Decimal/Hex/Octal -- What is the Difference?, Data Type Mismatch, Signed vs. Unsigned Integers, AutomationDirect.com Products and Data Types
Page 586
H--2
Numbering Systems
Appendix H Numbering Systems
Introduction As almost anyone who uses a computer is somewhat aware, the actual operations of a computer are done with a binary number system. Traditionally, the two possible states for a binary system are represented by the digits for ”zero” (0) and ”one” (1) although ”off” and ”on” or sometimes ”no” and yes” are closer to what is actually involved. Most of the time a typical PC user has no need to think about this aspect of computers, but every now and then one gets confronted with the underlying nature of the binary system. A PLC user should be more aware of the binary system specifically the PLC programmer. This appendix will provide an explanation of the numbering systems most commonly used by a PLC.
Binary Numbering System Computers, including PLCs, use the Base 2 numbering system, which is called Binary or Boolean. Like in a computer there are only two valid digits in Base 2 a PLC relies on, zero and one, or off and on respectively. You would think that it would be hard to have a numbering system built on Base 2 with only two possible values, but the secret is by encoding using several digits. Each digit in the base 2 system when referenced by a computer is called a bit. When four bits are grouped together, they form what is known as a nibble. Eight bits or two nibbles would be a byte. Sixteen bits or two bytes would be a word as in. Thirty--two bits or two words is a double word as in Table 1. Double Word Word Byte Nibble
Nibble
Word Byte
Nibble
Byte
Nibble
Nibble
Nibble
Byte Nibble
Nibble
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Table 1 Binary is not “natural“ for us to use since we have grown up using the base 10 system. Base 10 uses the numbers 0--9, as we are all well aware. From now on, the different bases will be shown as a subscripted number following the number. Example: 10 decimal would be 1010. Table 2 shows how base 2 numbers relate to their decimal equivalents. A nibble of 10012 would be equal to a decimal number 9 (1*23 + 1*20 or 810 + 110). A byte of 110101012 would be equal to 213 (1*27 + 1*26 +1*24 + 1*22 +1*20 or 12810 + 6410 + 1610 + 410 + 110).
Table 2
DL405 User Manual, 4th Edition
Page 587
Numbering Systems
H--3
Hexadecimal Numbering System The binary numbering system can be difficult and cumbersome to interpret for some users. Therefore, the hexadecimal numbering system was developed as a convenience for humans since the PLC (computer) only understands pure binary. The hexadecimal system is useful because it can represent every byte (8 bits) as two consecutive hexadecimal digits. It is easier for us to read hexadecimal numbers than binary numbers.
Decimal Hex
Decimal Hex
0
0
9
9
1
1
10
A
2
2
11
B
3
3
12
C
4
4
13
D
5
5
14
E
6
6
15
F
7
7
16
10
8
8
17
11
Table 3 Note that “10” and “11“ in hex are not the same as “10“ and “11“ in decimal. Only the first ten numbers 0--9 are the same in the two representations. For example, consider the hex number “D8AF“. To evaluate this hex number use the same method used to write decimal numbers. Each digit in a decimal number represents a multiple of a power of ten (base 10). Powers of ten increase from right to left. For example, the decimal number 365 means 3x102 + 6x10 + 5. In hex each digit represents a multiple of a power of sixteen (base 16). Therefore, the hex number D8AF translated to decimal means 13x163 + 8x162 + 10x16 + 15 = 55471. However, going through the arithmetic for hex numbers in order to evaluate them is not really necessary. The easier way is to use the calculator that comes as an accessory in Windows. It can convert between decimal and hex when in “Scientific“ view. Note that a hex number such as “365“ is not the same as the decimal number “365“. Its actual value in decimal terms is 3x162 6x16 + 5 = 869. To avoid confusion, hex numbers are often labeled or tagged so that their meaning is clear. One method of tagging hex numbers is to append a lower case “h“ at the end. Another method of labeling is to precede the number with 0x. Thus, the hex number “D8AF“ can also be written “D8AFh“, where the lower case “h” at the end is just a label to make sure we know that it is a hex number. Also, D8AF can be written with a labeling prefix as “0xD8AF”.
DL405 User Manual, 4th Edition
Appendix H Numbering Systems
The hexadecimal numbering system uses 16 characters (base 16) to represent values. The first ten characters are the same as our decimal system, 0--9, and the first six letters of the alphabet, A--F. Table 3 lists the first eighteen decimal numbers; 0--17 in the left column and the equivalent hexadecimal numbers are shown in the right column.
Page 588
H--4
Numbering Systems
Octal Numbering System
Appendix H Numbering Systems
Many of the early computers used the octal numbering system for compiled printouts. Today, the PLC is about the only device that uses the Octal numbering system. The octal numbering system uses 8 values to represent numbers. The values are 0--7 being Base 8. Table 4 shows the first 32 decimal digits in octal. Note that the octal values are 0--7, 10--17, 20--27, and 30--37. Octal
Decimal
Octal
Decimal
0
0
20
16
1
1
21
17
2
2
22
18
3
3
23
19
4
4
24
20
5
5
25
21
6
6
26
22
7
7
27
23
10
8
30
24
11
9
31
25
12
10
32
26
13
11
33
27
14
12
34
28
15
13
35
29
16
14
36
30
17
15
37
31
Table 4 This follows the DirectLOGIC PLCs. Refer to the bit maps in Chapter 3 and notice that the memory addresses are numbered in octal, as well as each bit. The octal system is much like counting in the decimal system without the digits 8 and 9 being available. The general format for four digits of the octal number is: (d x 80) + (d x 81) + (d x 82) + (d x 83) where “d“ means digit. This is the same format used in the binary, decimal, or hexadecimal systems except that the base number for octal is 8.
DL405 User Manual, 4th Edition
Page 589
H--5
Numbering Systems
Using the powers of expansion, the example below shows octal 4730 converted to decimal.
Appendix H Numbering Systems
Binary Coded Decimal (BCD) Numbering System BCD is a numbering system where four bits are used to represent each decimal digit. The binary codes corresponding to the hexadecimal digits A--F are not used in the BCD system. For this reason numbers cannot be coded as efficiently using the BCD system. For example, a byte can represent a maximum of 256 different numbers (i.e. 0--255) using normal binary, whereas only 100 distinct numbers (i.e. 0--99) could be coded using BCD. Also, note that BCD is a subset of hexadecimal and neither one does negative numbers. BCD Bit Pattern Bit #
15 14 13 12 11 10 103
Power Bit Value Max Value
8
4
2 9
9
8
7
102 1
8
4
2 9
6
5
4
3
101 1
8
4
2 9
2
1
0
100 1
8
4
2
1
9
Table 5 One plus for BCD is that it reads like a decimal number, whereas 867 in BCD would mean 867 decimal. No conversion is needed.
DL405 User Manual, 4th Edition
Page 590
H--6
Numbering Systems
Real (Floating Point) Numbering System The terms Real and floating--point both describe IEEE--754 floating point arithmetic. This standard specifies how single precision (32 bit) and double precision (64 bit) floating point numbers are to be represented as well as how arithmetic should be carried out on them. Most PLCs use the 32--bit format for floating point (or Real) numbers which will be discussed here. Appendix H Numbering Systems
Real (Floating Point 32) Bit Pattern 31
Bit #
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Sign
Exponent
15
14 13 12 11 10
Bit #
Mantissa 9
8
7
6
5
4
3
2
1
0
Mantissa (continues from above) Table 6 Floating point numbers, which DirectLOGIC PLCs use, have three basic components: sign, exponent and mantissa. The 32 bit word required for the IEEE standard floating point numbers is shown in Table 6. It is represented as a number bits from 0 to 31, left to right. The first bit (31) is the sign bit, the next eight bits (30--23) are the exponent bits and the final 23 bits (22--0) are the fraction bits. In summary: The sign bit is either “0” for positive or “1“ for negative; The exponent uses base 2; The first bit of the mantissa is typically assumed to be “1.fff“, where “f“ is the field of fraction bits. The Internet can provide a more in--depth explanation of the floating point numbering system. One website to look at is: http://www.psc.edu/general/software/packages/ieee/ieee.php
DL405 User Manual, 4th Edition
Page 591
H--7
Numbering Systems
BCD/Binary/Decimal/Hex/Octal -- What is the Difference? Sometimes there is confusion about the differences between the data types used in DirectLOGIC PLCs. The PLC’s native data format is BCD, while the I/O numbering system is octal. Other numbering formats used are binary, decimal and Real. Although data is stored in the same manner (0’s and 1’s), there are differences in the way that the PLC interprets it. While all of the formats rely in the base 2 numbering system and bit--coded data, the format of the data is dissimilar. The formats discussed are shown in Table 7 below. Bit # Decimal
Bit Value
15
14
13
12
11
10
9
8
7
3 2 6 7 8
1 6 3 8 4
8 1 9 2
4 0 9 6
2 0 4 8
1 0 2 4
5 1 2
2 5 6
1
Max Value
2 8
6
5
4
3
2
1
0
6 4
3 2
1 6
8
4
2
1
65535
Hexidecimal Bit Pattern Bit #
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Decimal Bit Value
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Max Value
F
F
F
F
BCD Bit Pattern Bit #
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Decimal Bit Value
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Max Value
9
9
9
9
Octal Bit Pattern Bit #
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit Value
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
Max Value
1
7
7
7
7
7
Octal Bit Pattern Bit #
31
30
29
28
15
26
25
24
23
22
21
20
Exponent
Sign Bit #
27
14
13
12
11
10
19
18
17
16
1
0
Mantissa 9
8
7
6
5
4
3
2
Mantissa (continued from above) Table 7 As seen in Table 7, the BCD and hexadecimal formats are similar, although the maximum number for each grouping is different (9 for BCD and F for hexadecimal). This allows both formats to use the same display method. The unfortunate side effect is that unless the data type is documented, it’s difficult to know what the data type is unless it contains the letters A--F.
DL405 User Manual, 4th Edition
Appendix H Numbering Systems
Binary/Decimal Bit Pattern
Page 592
H--8
Numbering Systems
Data Type Mismatch Data type mismatching is a common problem when using an operator interface. Diagnosing it can be a challenge until you identify the symptoms. Since the PLC uses BCD as the native format, many people tend to think it is interchangeable with binary (unsigned integer) format. This is true to some extent, but not in this case. Table 8 shows how BCD and binary numbers differ. Appendix H Numbering Systems
Data Type Mismatch Decimal
0
1
2
3
4
5
6
7
8
9
10
11
BCD
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 0001 0000 0001 0001
Binary
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 0000 1010 0000 1011 Table 8 As the table shows, BCD and binary share the same bit pattern up until you get to the decimal number 10. Once you get past 10, the bit pattern changes. The BCD bit pattern for the decimal 10 is actually equal to a value of 16 in binary, causing the number to jump six digits by when viewing it as the BCD. With larger numbers, the error multiplies. Binary values from 10 to 15 Decimal are actually invalid for the BCD data type. Looking at a larger number, such as the value shown in Table 9, both the BCD bit pattern and the decimal bit pattern correspond to a base 10 value of 409510. If bit patterns are read, or interpreted, in a different format than what is used to write them, the data will not be correct. For instance, if the BCD bit pattern is interpreted as a decimal (binary) bit pattern, the result is a base 10 value of 1653310. Similarly, if you try to view the decimal (binary) bit pattern as a BCD value, it is not a valid BCD value at all, but could be represented in hexadecimal as 0xFFF.
Base 10 Value
BCD Bit Pattern
Binary Bit Pattern
4095
0100 0000 1001 0101
1111 1111 1111
Table 9 Look at the following examples and note the same value represented by the different numbering systems. The decimal values of 67 and 4660 are used. 6 7 Decimal 0110 0111 BCD 0100 0011 Binary 4 3 Hex 1 0 3 Octal
DL405 User Manual, 4th Edition
4 6 6 0 Decimal 0100 0110 0110 0000 BCD 0001 0010 0011 0100 Binary 1 2 3 4 Hex 1 1 0 6 4 Octal
Page 593
H--9
Numbering Systems
Signed vs. Unsigned Integers
Bit # 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Table 10 There are two ways to encode a negative number: two’s complement and Magnitude Plus sign. The two methods are not compatible. The simplest method to represent a negative number is to use one bit of the PLC word as the sign of a number while the remainder of the word gives its magnitude. It is general convention to use the most significant bit (MSB) as the sign bit: a 1 will indicate a negative, and a 0 a positive number. Thus, a 16 bit word allows numbers in the range ¦32767. The following tables show a representation of 100 and a representation of --100 in this format. Magnitude Plus Sign Decimal
Binary
100
0000 0000 0110 0100
--100
1000 0000 0110 0100
Table 11 Two’s complement is a bit more complicated. Without getting involved with a full explanation, a simple formula for two’s complement is to invert the binary and add one (see Table 12). Basically, 1’s are being changed to 0’s and all 0’s are being changed to 1, then a 1 is added. Two’s Compliment Decimal
Binary
100
0000 0000 0110 0100
--100
1111 1111 1001 1100
Table 12 More information about 2’s complement can be found on the Internet, however most of the websites deal with 8--bit examples. Two fairly good websites are listed below, you can also do a search and checkout more websites. http://www.evergreen.edu/biophysics/technotes/program/2s_comp.htm http://www.website.masmforum.com/tutorials/fptute/fpuchap2.htm
DL405 User Manual, 4th Edition
Appendix H Numbering Systems
So far, we have dealt with unsigned data types only. Now we will deal with signed data types (negative numbers). The BCD and hexadecimal numbering systems do not use signed data types. In order to signify that a number is negative or positive, we must assign a bit to it. Usually, this is the Most Significant Bit (MSB) as shown in Table 10. For a 16--bit number, this is bit 15. This means that for 16--bit numbers we have a range of --32767 to 32767.
Page 594
H--10
Numbering Systems
AutomationDirect.com Products and Data Types
Appendix H Numbering Systems
DirectLOGIC PLCs
The DirectLOGIC PLC family uses the octal numbering system for all addressing which includes: inputs, outputs, internal V--memory locations, timers, counters, internal control relays (bits), etc. Most data in the PLC, including timer and counter current values, is in BCD format by default. User data in V--memory locations may be stored in other data types if it is changed by the programmer, or comes from some external source, such as an operator interface. Any manipulation of data must use instructions appropriate for that data type which includes: Load instructions, Math instructions, Out box instructions, comparison instructions, etc. In many cases, the data can be changed from one data type to another, but be aware of the limitations of the various data types when doing so. For example, to change a value from BCD to decimal (binary), use a BIN instruction box. To change from BCD to a real number, use a BIN and a BTOR instruction box. When using Math instructions, the data types must match. For example, a BCD or decimal (binary) number cannot be added to a real number, and a BCD number cannot be added to a decimal (binary) number. If the data types are mismatched, the results of any math operation will be meaningless. To simplify making, number conversions Intelligent Box (IBox) Instructions are available with DirectSOFT 5. These instruction descriptions are located in the DL405 IBox Instructions PLC User Manual Supplement, page 30, in the Math IBox group. Most DirectLOGIC analog modules can be setup to give the raw data in decimal (binary) format or in BCD format, so it is necessary to know how the module is being used. DirectLOGIC PID is another area where not all values are in BCD. In fact, nearly all of the PID parameters are stored in the PLC memory as decimal (binary) numbers. NOTE: The PID algorithm uses magnitude plus sign for negative decimal (binary) numbers, whereas the standard math functions use two’s complement. This can cause confusion while debugging a PID loop.
C--more/C--more Micro--Graphic Panels
When using the Data View in DirectSOFT, be certain that the proper format is selected for the element to be viewed. The data type and length is selected using the drop--down boxes at the top of the Data View window. Also notice that BCD is called BCD/Hex. Remember that BCD is a subset of hexadecimal so they share a display format even though the values may be different. This is where good documentation of the data type stored in memory is crucial. In the C--more and C--more Micro--Graphic HMI operator panels, the 16--bit BCD format is listed as “BCD int 16“. Binary format is either “Unsigned int 16“ or “Signed int 16“ depending on whether or not the value can be negative. Real number format is “Floating PT 32”. More available formats are, “BCD int 32“, “Unsigned int 32“ and “Signed int 32“.
DL405 User Manual, 4th Edition