Page 210
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 5–56
X1
LD P2000 V2000 (P2000) contains the value 440 HEX. 440 HEX. = 2100 Octal which contains the value 2635. V2000 0
4
4
0
V2076
X
X
X
V2077
X
X
X
X X
V2100
2
6
3
5
V2101
X
X
X
X
V2102
X
X
X
X
V2103
X
X
X
X
V2104
X
X
X
X
V2105
X
X
X
X
V2200
2
6
3
5
V2201
X
X
X
X
Accumulator 2
6
3
5
OUT V2200 Copy the data from the lower 16 bits of the accumulator to V2200.
The following example is identical to the one above with one exception. The LDA (Load Address) instruction automatically converts the Octal address to Hex.
X1
LDA O 2100
Load the lower 16 bits of the accumulator with Hexadecimal equivalent to Octal 2100 (440)
2
1
0
0 2100 Octal is converted to Hexadecim 440 and loaded into the accumulator
Unused accumulator bits are set to zero Acc. 0
OUT V 2000
LD P 2000
0
00 44 44 00
0
4
4
0
V2000
V2000 (P2000) contains the value 440 Hex. 440 Hex. = 2100 Octal which contains the value 2635
0
V 2200
0
Copy the data from the lower 16 bits of the accumulator to V2000
V2100
OUT
0
4
4
0
Copy the data from the lower 16 bits of the accumulator to V2200
DL06 Micro PLC User Manual, 3rd Edition Rev. A
V2076
X
X
X
V2077
X
X
X
X X
V2100
2
6
3
5
V2101
X
X
X
X
V2102
X
X
X
X
V2103
X
X
X
X
V2104
X
X
X
X
V2105
X
X
X
X
V2200
2
6
3
5
V2201
X
X
X
X
Accumulator 0
0
0
0
22 66 33 55
Page 211
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load (LD) DS5
Used
HPP
Used
The Load instruction is a 16 bit instruction that loads the value (Aaaa), which is either a V-memory location or a 4 digit constant, into the lower 16 bits of the accumulator. The upper 16 bits of the accumulator are set to 0.
LD A aaa
Operand Data Type
DL06 Range aaa
....................................A V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K
See memory map See memory map 0–FFFF
Discrete Bit Flags
Description
SP53 SP70 SP76
On when the pointer is outside of the available range. On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack.
In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator and output to V2010. Direct SOFT32 5 DirectSOFT
V2000
X1
LD
8
9
3
5
V2000 The unused accumulator bits are set to zero
Load the value in V2000 into the lower 16 bits of the accumulator
Acc. 0
0
0
0
88 99 33 55
OUT V2010 8
Copy the value in the lower 16 bits of the accumulator to V2010
9
3
5
V2010
Handheld Programmer Keystrokes B
$ STR SHFT
L ANDST
D
C
A
A
2 GX OUT
X 1
0
SET
3 A 0
0
SHFT
V AND
ENT C
A 2
B 0
A 1
0
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 5–57
Page 212
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load Double (LDD)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5
Used
HPP
Used
5–58
The Load Double instruction is a 32 bit instruction that loads the value (Aaaa), which is either two consecutive V-memory locations or an 8 digit constant value, into the accumulator. Operand Data Type
A aaa
DL06 Range aaa
....................................A V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K
Discrete Bit Flags
LDD
See memory map See memory map 0–FFFF
Description
SP53 SP70 SP76
On when the pointer is outside of the available range. On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack.
In the following example, when X1 is on, the 32 bit value in V2000 and V2001 will be loaded into the accumulator and output to V2010 and V2011. DirectSOFT SOFT32 5 Direct X1
V2001
LDD V2000
V2000
6
7
3
9
5
0
2
6
Acc. 6
7
3
9
65 00 22 66
6
7
3
9
5
Load the value in V2000 and V2001 into the 32 bit accumulator
OUTD V2010 Copy the value in the 32 bit accumulator to V2010 and V2011 Handheld Programmer Keystrokes $
B STR
1
SHFT
L ANDST
D
C
A
A 0
GX OUT
SHFT
D
C
A
B 0
D 3
2
2
ENT
3 A
0
0
ENT
3 A 1
0
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
V2011
0
2
V2010
6
Page 213
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load Formatted (LDF) DS5
Used
HPP
Used
The Load Formatted instruction loads 1–32 consecutive bits from discrete memory locations into the accumulator. The instruction requires a starting location (Aaaa) and the number of bits (Kbbb) to be loaded. Unused accumulator bit locations are set to zero.
LDF K bbb
Operand Data Type
DL06 Range
....................................A Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . C Stage Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Timer Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T Counter Bits . . . . . . . . . . . . . . . . . . . . . . . . . . CT Special Relays . . . . . . . . . . . . . . . . . . . . . . . . . SP Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K
Discrete Bit Flags SP70 SP76
A aaa aaa bbb
0–777 0–777 0–1777 0–1777 0–377 0–177 0–777 ––
–– –– –– –– –– –– –– 1–32
Description On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack.
In the following example, when C0 is on, the binary pattern of C10–C16 (7 bits) will be loaded into the accumulator using the Load Formatted instruction. The lower 7 bits of the accumulator are output to Y0–Y6 using the Out Formatted instruction. DirectSOFT 5
Direct SOFT32 C0
LDF
C10 K7
Load the status of 7 consecutive bits (C10–C16) into the accumulator
Constant
C10
K7
C16 C15 C14 C13 C12 C11 C10 OFF OFF OFF ON ON ON OFF
The unused accumulator bits are set to zero
Acc.
OUTF
Location
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
4 3
2
1
0
0
0
0
0
0
0
1
1
1
0
Y4
Y3
Y2
Y1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Y0 K7
Copy the value from the specified number of bits in the accumulator to Y0 – Y6
Location
Constant
Y6 Y5
Y0
K7
OFF OFF OFF ON ON ON OFF
Handheld Programmer Keystrokes SHFT
C
SHFT
L ANDST
D
F
SHFT
C
B
GX OUT
SHFT
$ STR
A
3
2
0
ENT
5 A
1
H 0
7
ENT
F 5 H
0
A 2
7
Y0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
5–59
Page 214
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load Address (LDA)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5
Used
HPP
Used
5–60
The Load Address instruction is a 16 bit instruction. It converts any octal value or address to the HEX equivalent value and loads the HEX value into the accumulator. This instruction is useful when an address parameter is required since all addresses for the DL06 system are in octal.
LDA O aaa
Operand Data Type
DL06 Range aaa
Octal Address . . . . . . . . . . . . . . . . . . . . . . . . . . O
See memory map
Discrete Bit Flags
Description
SP70 SP76
On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack.
In the following example when X1 is on, the octal number 40400 will be converted to a HEX 4100 and loaded into the accumulator using the Load Address instruction. The value in the lower 16 bits of the accumulator is copied to V2000 using the Out instruction.
DirectSOFT Direct SOFT32 5 X1
4
O 40400
0
Load The HEX equivalent to the octal number into the lower 16 bits of the accumulator
Handheld Programmer Keystrokes 1
SHFT
L ANDST
D
E
A
E
4 GX OUT
0
ENT A
3
0 A
A
4
0
SHFT
V AND
0 C
ENT A
2
0
4
1
0
0
0
0
0
4
1
0
0
4
1
0
0
V2000
Copy the value in lower 16 bits of the accumulator to V2000
B
0
Acc. 0
V2000
STR
4
The unused accumulator bits are set to zero
OUT
$
Hexadecimal
Octal
LDA
A 0
A 0
0
DL06 Micro PLC User Manual, 3rd Edition Rev. A
ENT
Page 215
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load Accumulator Indexed (LDX) DS5
Used
HPP
Used
Load Accumulator Indexed is a 16 bit instruction that specifies a source address (V-memory) which will be offset by the value in LDX the first stack location. This instruction interprets the value in A aaa the first stack location as HEX. The value in the offset address (source address + offset) is loaded into the lower 16 bits of the accumulator. The upper 16 bits of the accumulator are set to 0. Helpful Hint:, The Load Address instruction can be used to convert an octal address to a HEX address and load the value into the accumulator.
1 2 3 4 Operand Data Type DL06 Range A aaa aaa 5 6 Discrete Bit Flags Description 7 8 NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack. 9 In the following example when X1 is on, the HEX equivalent for octal 25 will be loaded into the accumulator (this value will be placed on the stack when the Load Accumulator Indexed 10 instruction is executed). V-memory location V1410 will be added to the value in the 1st. level of the stack and the value in this location (V1435 = 2345) is loaded into the lower 16 bits of 11 the accumulator using the Load Accumulator Indexed instruction. The value in the lower 16 12 13 14 A B C bits of the accumulator is output to D V1500 using the Out instruction. V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
SP53 SP70 SP76
X1
See memory map See memory map
See memory map See memory map
On when the pointer is outside of the available range. On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
LDA
O 25
Load The HEX equivalent to octal 25 into the lower 16 bits of the accumulator
Octal
Hexadecimal
2
0
0
1
5
0
0
1
5
V 1
4
5
The unused accumulator bits are set to zero Acc. 0
0
0
0
LDX
V1410
HEX Value in 1st stack location
Octal
Move the offset to the stack. Load the accumulator with the address to be offset
V 1
4
1
0
+
1
5
Accumulator Stack
Octal
=
3
5
The unused accumulator bits are set to zero
OUT
Acc. 0
V1500
0
0
0
2
3
4
5
The value in V1435 is 2345
Copy the value in the lower 16 bits of the accumulator to V1500
2
3
4
5
Level 1
0
0
0
0
0
0
1
5
Level 2
X
X
X
X
X
X
X
X
Level 3
X
X
X
X
X
X
X
X
Level 4
X
X
X
X
X
X
X
X
Level 5
X
X
X
X
X
X
X
X
Level 6
X
X
X
X
X
X
X
X
Level 7
X
X
X
X
X
X
X
X
Level 8
X
X
X
X
X
X
X
X
Handheld Programmer Keystrokes $
V1500
B
STR
1
SHFT
L ANDST
D
SHFT
L ANDST
D
GX OUT
ENT
A
F
C
3
0
3
X SET
PREV
PREV
5
2
B
E 1
PREV
4 F
B 1
ENT
B
A 1
A 5
0 A
0
0
ENT ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
5–61
Page 216
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Load Accumulator Indexed from Data Constants (LDSX)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5
Used
HPP
Used
The Load Accumulator Indexed from Data Constants is a 16 bit instruction. The instruction specifies a Data Label Area LDSX K aaa (DLBL) where numerical or ASCII constants are stored. This value will be loaded into the lower 16 bits. The LDSX instruction uses the value in the first level of the accumulator stack as an offset to determine which numerical or ASCII constant within the Data Label Area will be loaded into the accumulator. The LDSX instruction interprets the value in the first level of the accumulator stack as a HEX value. Helpful Hint:, The Load Address instruction can be used to convert octal to HEX and load the value into the accumulator. Operand Data Type aaa Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K
1-FFFF
Discrete Bit Flags
Description
SP53 SP70 SP76
On when the pointer is outside of the available range. On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
NOTE: Two consecutive Load instructions will place the value of the first load instruction onto the accumulator stack.
In the following example when X1 is on, the offset of 1 is loaded into the accumulator. This value will be placed into the first level of the accumulator stack when the LDSX instruction is executed. The LDSX instruction specifies the Data Label (DLBL K2) where the numerical constant(s) are located in the program and loads the constant value, indicated by the offset in the stack, into the lower 16 bits of the accumulator. Hexadecimal X1
LD
0 K1
Load the offset value of 1 (K1) into the lower 16 bits of the accumulator.
0
0
1
0
0
1
0
Acc.
0
0
0
Accumulator Stack
0
K2
Constant
Move the offset to the stack. Load the accumulator with the data label number
DLBL DLBL
0
Acc.
Copy the value in the lower 16 bits of the accumulator to V2000
0
0
0
0
0
0
0
0
The unused accumulator bits are set to zero
END
Acc.
0
0
0
0
2
3
2
3
2
3
2
3
K2
NCON K3333
NCON K2323
K4549
2
The unused accumulator bits are set to zero
V2000
.
0
K
OUT . .
Value in 1st. level of stack is used as offset. The value is 1
The unused accumulator bits are set to zero
LDSX
NCON
5–62
DL06 Range
Offset 0
Offset 1
Offset 2
DL06 Micro PLC User Manual, 3rd Edition Rev. A
V2000
2
Level 1
0
0
0
0
0
0
0
1
Level 2
X
X
X
X
X
X
X
X
Level 3
X
X
X
X
X
X
X
X
Level 4
X
X
X
X
X
X
X
X
Level 5
X
X
X
X
X
X
X
X
Level 6
X
X
X
X
X
X
X
X
Level 7
X
X
X
X
X
X
X
X
Level 8
X
X
X
X
X
X
X
X
Page 217
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data $
B STR
1
SHFT
L ANDST
D
SHFT
L ANDST
D
SHFT
E
N TMR
D
4
SHFT
D
B
3
L ANDST
SHFT
N TMR
C
SHFT
N TMR
C
SHFT
N TMR
C
GX OUT
SHFT
3 3
Handheld Programmer Keystrokes
ENT
S RST 3
K JMP
X SET
B 1 C 2
ENT
ENT C
1
L ANDST N TMR
D
2
O INST#
N TMR
C
2
O INST#
N TMR
E
2
O INST# V AND
C
SHFT
ENT
2 3
D 3
4
5 0
3 D
2 E
A 0
D 3
C
F
A 0
D 3
2
A 2
ENT D
3 J
4
9
ENT ENT ENT
ENT
Load Real Number (LDR) DS5
Used
HPP
N/A
The Load Real Number instruction loads a real number contained in two consecutive V-memory locations, or an 8-digit constant into the accumulator. Operand Data Type
LDR A aaa
DL06 Range
....................................A aaa
V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Real Constant . . . . . . . . . . . . . . . . . . . . . . . . . . R
See memory map See memory map
Discrete Bit Flags SP70 SP76
-3.402823E+38 to + -3.402823E+38
Description On anytime the value in the accumulator is negative. On when any instruction loads a value of zero into the accumulator.
DirectSOFT 5 allows you to enter real numbers directly, by using the leading “R” to indicate a real number entry. You can enter a constant such as Pi, shown in the example to the right. To enter negative numbers, use a minus (–) after the “R”. For very large numbers or very small numbers, you can use exponential notation. The number to the right is 5.3 million. The OUTD instruction stores it in V1400 and V1401. These real numbers are in the IEEE 32-bit floating point format, so they occupy two V-memory locations, regardless of how big or small the number may be! If you view a stored real number in hex, binary, or even BCD, the number shown will be very difficult to decipher. Just like all other number types, you must keep track of real number locations in memory, so they can be read with the proper instructions later. The previous example above stored a real number in V1400 and V1401. Suppose that now we want to retrieve that number. Just use the Load Real with the V data type, as shown to the right. Next we could perform real math on it, or convert it to a binary number.
LDR R3.14159
LDR R5.3E6 OUTD V1400
LDR V1400
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 5–63
Page 218
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Output Data
Out (OUT)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5
Used
HPP
Used
The Out instruction is a 16 bit instruction that copies the value in the lower 16 bits of the accumulator to a specified Vmemory location (Aaaa). Operand Data Type
OUT A aaa
DL06 Range aaa
....................................A V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
See memory map See memory map
Discrete Bit Flags
Description
SP53
On if CPU cannot solve the logic.
In the following example, when X1 is on, the value in V2000 will be loaded into the lower 16 bits of the accumulator using the Load instruction. The value in the lower 16 bits of the accumulator are copied to V2010 using the OUT instruction. DirectSOFT 5 Direct SOFT32 X1
Handheld Programmer Keystrokes V2000
LD 8
V2000 Load the value in V2000 into the lower 16 bits of the accumulator
9
3
STR
The unused accumulator bits are set to zero Acc. 0
0
0
0
B
$ 5
SHFT
L ANDST
D
C
A
A
2
88 99 33 55
0
GX OUT
OUT V2010 Copy the value in the lower 16 bits of the accumulator to V2010
8
9
3
ENT
1 3
A
ENT
0
0
SHFT
V AND
C
A 2
B 0
A 1
0
5
V2010
Out Double (OUTD) DS5
Used
HPP
Used
The Out Double instruction is a 32 bit instruction that copies the value in the accumulator to two consecutive Vmemory locations at a specified starting location (Aaaa). Operand Data Type
DL06 Range aaa
....................................A V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
See memory map See memory map
Discrete Bit Flags
Description
SP53
On if CPU cannot solve the logic.
In the following example, when X1 is on, the 32 bit value in V2000 and V2001 will be loaded into the accumulator using the Load Double instruction. The value in the accumulator is output to V2010 and V2011 using the OUTD instruction. DirectSOFT 5
V2001
Direct SOFT32
6 X1
7
3
Handheld Programmer Keystrokes
V2000 9
5
0
2
6
LDD
B
$
1
STR V2000
Load the value in V2000 and V2001 into the accumulator
Acc. 6
7
3
9
55 00 22 66
SHFT
L ANDST
D
C
A
A
2 OUTD V2010 Copy the value in the accumulator to V2010 and V2011
5–64
OUTD A aaa
6
7
3
V2011
9
5
0
2
6
V2010
DL06 Micro PLC User Manual, 3rd Edition Rev. A
3
0 SHFT
D
C
A
B 0
3 A
0
GX OUT 2
ENT D
0
ENT
3 A 1
0
ENT
ENT
Page 219
Chapter 5: Standard RLL Instructions - Accumulator/Stack Load and Data
Out Formatted (OUTF) DS5
Used
HPP
Used
The Out Formatted instruction outputs 1–32 bits from the accumulator to the specified discrete memory locations. The instruction requires a starting location (Aaaa) for the destination and the number of bits (Kbbb) to be output.
OUTF A aaa K bbb
Operand Data Type
DL06 Range
....................................A Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . C Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K aaa bbb
0–777 0–777 0–1777 ––
–– –– –– 1–32
In the following example, when C0 is on, the binary pattern of C10–C16 (7 bits) will be loaded into the accumulator using the Load Formatted instruction. The lower 7 bits of the accumulator are output to Y0–Y6 using the OUTF instruction. DirectSOFT 5
Direct SOFT32 C0
LDF
C10 K7
Load the status of 7 consecutive bits (C10–C16) into the accumulator
OUTF
Location
Constant
C10
K7
C16 C15 C14 C13 C12 C11
C10
OFF OFF OFF ON ON ON OFF
The unused accumulator bits are set to zero
Y20
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
4 3
2
1
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Accumulator
K7 Copy the value of the specified number of bits from the accumulator to Y20–Y26
Location
Constant
Y26 Y25 Y24 Y23 Y22 Y21 Y20
Y20
K7
OFF OFF OFF ON ON ON OFF
Handheld Programmer Keystrokes $ STR
SHFT
C F
SHFT
L ANDST
D
SHFT
C
B
GX OUT
3
2 SHFT
A
0
1
ENT
5 A
H 0
7
ENT
F 5 H
0
A 2
7
ENT
Pop (POP) DS5
Used
HPP
Used
The Pop instruction moves the value from the first level of the accumulator stack (32 bits) to the accumulator and shifts each value in the stack up one level.
POP
Discrete Bit Flags
Description
SP63
ON when the result of the instruction causes the value in the accumulator to be zero.
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
5–65