For the Banner CL5RA and Banner CM5RA
Page 11
MAXI-AMP™ CL Series Logic-level Input Modules Recognized
Certified
Banner CL Series MAXI-AMP™ modules are the perfect solution for many sensing/control applications where economy, versatility, dependability, and ruggedness are important. CL Series MAXI-AMPs combine power supply, timing logic (in CL5 models) and output relay in a single compact, cost-saving module. The integrated, stand-alone design saves both the expense of a separate control chassis and a substantial amount of panel space. Several models are available, for either 120V ac or 240V ac operation, and either with or without timing logic (models are listed in table at above right). Alternatively, any model may be powered by 12 to 28V dc. The well-defined electrical characteristics of CL Series MAXI-AMP modules provide a wealth of application possibilities. The input circuit accepts signals from any Banner dc sensor with an NPN (current sinking) output; as well as from MAXI-AMP, MICRO-AMP, and Plug Logic modules. The input is compatible with almost any sensor or circuit which has an NPN transistor (current sinking) output. Additionally, inputs may be generated by limit switches, contact closures, and optical couplers. A 50mA power supply is included for powering 10 to 30V dc devices. CL5 models offer a versatile multi-function timing logic circuit which is programmable for twelve of the most popular and useful delay, one-shot, and latch functions (see page 5). The MAXI-AMP offers the choice of either single or dual timing functions in the same module. Logic and timing may be easily reprogrammed as control requirements change.
Solid-state Output Option CL Series modules are available with a solid-state relay which replaces the electromechanical relay. This is actually two SPST solid-state contacts. One contact will switch ac loads, and is rated at 250V ac maximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 amp at 50 degrees C). A solid-state contact is particularly helpful when switching inductive ac loads which can cause electrical "noise" and contact damage when switched with a "hard" relay contact. The other solid-state contact will switch dc loads of up to 30V dc and up to 50 milliamps. Both solid-state outputs are electrically isolated from the MAXI-AMP power supply. Both outputs switch within the 1 millisecond response time of the CL module circuitry. NOTE: ac loads may take up to 1/2 cycle (8.3 milliseconds) to turn "off".
OUTPUT
LOGIC
CL3RA
SUPPLY VOLTAGE 105 to 130V ac, or 12 to 28V dc
CL3RB
210 to 250V ac, or 12 to 28V dc
SPDT electromechanical relay, plus NPN transistor solidstate switch
ON/OFF
CL5RA
105 to 130V ac, or 12 to 28V dc
CL5RB
210 to 250V ac, or 12 to 28V dc
SPDT electromechanical relay (5 amp contact rating)
12 timing functions
MODEL
In order to allow accurate timing adjustments, each CL5 model has three time ranges to choose from. Timing adjustments are made via rugged 15-turn potentiometers. Circuitry is included to prevent any possibility of false output on power-up. An auxiliary input is available on CL5 models for interrogation or reset of the selected logic function by using an additional sensor or input signal (see example, page 3). Page 5 describes the function of the auxiliary input for each logic mode. The output circuit for all CL Series modules is an SPDT 5-amp electro-mechanical relay. A solid-state relay is offered as an option to the electromechanical relay (see information below). Additionally, CL3 models have an NPN transistor solid-state switch. This solid-state output may be used to take advantage of the amplifier's fast 1-millisecond response. This output may be connected directly to the primary or auxiliary input of other Banner logic modules, including CL5 modules, MICRO-AMP logic modules, and Plug Logic modules. In addition, this output can interface to other dc devices or circuits such as counters, rate meters, or programmable controllers. Switching capacity is 20mA at 12V dc. The output may be programmed for either normally open or normally closed operation. Like all MAXI-AMPs, the CL Series modules are designed both electrically and mechanically for solid dependability in industrial environments.
MODEL
SUPPLY VOLTAGE
CL3A
105 to 130V ac, or 12 to 28V dc
CL3B
210 to 250V ac, or 12 to 28V dc
CL5A
105 to 130V ac, or 12 to 28V dc
CL5B
210 to 250V ac, or 12 to 28V dc
OUTPUT SPST solidstate contact for switching AC loads up to 250V ac and up to 3/4 amp, plus solidstate contact for switching dc loads up to 30V dc and up to 50mA.
LOGIC ON/OFF
12 timing functions
Both outputs are normally open, but may be programmed for normally closed operation. Except for the output configuration, the specifications for the models listed in the table at the right are exactly the same as for the standard CL Series models.
Please read Personnel Safety Warning, page 3.
P/N 03449D4E
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 12
MAXI-AMP CL Series Specifications SUPPLY VOLTAGE: Models CL3RA, CL5RA: 105 to 130V ac,
50/60Hz (4 VA), or 12 to 28V dc* at 60mA. Models CL3RB, CL5RB: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc at 60mA. *Do not connect ac voltage if using external dc power.
OUTPUT CONFIGURATION: all models have SPDT electromechanical relay: CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load), 1/10 H.P. at 240V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. CLOSURE TIME: 10 milliseconds max. RELEASE TIME: 10 milliseconds max. MAXIMUM SWITCHING SPEED: 20 operations/second MECHANICAL LIFE: 20,000,000 operations CL3 models also have a logic level current sinking NPN transistor switch at pin #9. See schematic below and hookup info.
INDICATOR LEDs: Red indicator LEDs for input and output status.
CONSTRUCTION: Rugged NORYL® polyphenylene oxide
(PPO®) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base. OPERATING TEMPERATURE: 0 to 50 degrees C (32 to 122 degrees F).
Generalized Hookup:
models with electromechanical relay output
AMPLIFIER:
RESPONSE SPEED: 1 millisecond INPUT CHARACTERISTICS: input is switched when the voltage at pin #2 is pulled below 1V dc or when less than 1K ohms is connected between pins #2 and #1. When an inverting jumper is connected between pins #10 and #11, input is switched when the voltage at pin #2 rises above 4.5V dc or when the impedance between pins #2 and #1 exceeds 15K ohms. HYSTERESIS: greater than .35 volts, less than 2 volts.
Dimension Drawing
MULTIPLE SENSOR HOOKUP: any number of switched output devices may be connected in parallel to the input (see hookup example).
TIMERS (CL5 models only):
TIME RANGES: LOW range - 10 to 150 milliseconds
MIDDLE range - 0.1 to 1.5 seconds
HIGH range - 1 to 15 seconds REPEATABILITY: +/-2% of set time over all extremes of supply voltage and temperature
ADJUSTMENTS: Miniature switches for setting of timing function, timing range, and output polarity (CL5 models). 15-turn clutched potentiometer for time setting (CL5 models).
CL5 Models
Functional Schematics
NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device (see hookup example). Current available is 50mA at 120V ac (240V ac) line level; 40mA at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power.
CL3 Models
NOTE #2: pulling pin #9 low (to Common) will inhibit the timing, or reset the latch of CL5 models. (See "Description of Logic Functions", page 5) NOTE #3: pin #9 of model CL3RA and CL3RB may be connected directly to the primary or auxiliary input of MAXI-AMP model CL5 or to Banner Plug Logic modules.
2 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 13
Sensor Hookup Diagrams, CL Series MAXI-AMP Modules To MAXI-BEAM Sensors
To MULTI-BEAM Sensors NOTE: use power block model PBT or PBT2.
MAXI-BEAM
NOTE: use power block model RPBT.
4
4 5 6 7 8
3 2
CL3� or � CL5� model
RPBT
1 11
5
4� 3� 2� 1
6 7 8
CL3� or � CL5� model
10 9
MULTI-BEAM
3 2
PBT
1 11
3
4
1
2
10 9
NOTE: the MAXI-AMP cannot power a MULTI-BEAM emitter and receiver pair. Use a separate power source for the emitter (e.g.- power block PBA-1, etc.)
To MINI-BEAM SM312 Series Sensors
To VALU-BEAM SM912 Series SM912 Sensors NOTE: Black wire is not used
BROWN 4 5 6 7 8
CL3� or � CL5� model
3 2 1 11
WHITE
SM312
BLUE
10 9
4 5 6 7 8
CL3� or � CL5� model
NOTE: Black wire is not used
To ECONO-BEAM SE612 SeriesNOTE: Sensors Black wire is not used 5 6 7 8
CL3� or � CL5� model
10 9
BROWN WHITE BLUE
NOTE: White wire is not used 4 5
3 2 1 11 10 9
1 11
To EZ-BEAM Sensors SE612
NOTE: black wire is not used.
4
3 2
6 7 8
BROWN WHITE
CL3� or � CL5� model
3 2 1 11
BROWN BLACK
10 9
BLUE
BLUE
This hookup is for DC NPN (current sinking) models of S18 Series, Q25 Series, and other DC sensors bearing the EZ-BEAM logo.
Use of Auxiliary Input (CL5 models) CL5 model MAXI-AMPs have an auxiliary input at terminal #9 which may be used for the interrogation or reset of the selected logic function. This is accomplished by a switch closure between pins #9 and #1 (Common). The auxiliary input may also be switched by a DC device with an NPN transistor (current sinking) output. The effect of the auxiliary input is described for each logic function on page 5. This example shows a typical inspection/rejection scheme which uses a Banner MINI-BEAM as the inspection sensor. Typically, the CL5 module would be programmed for the ONE-SHOT or DELAYED ONE-SHOT logic function. If the SM312 "sees" an acceptable condition when the SE612 senses the leading (or trailing) edge of the product, the SM312 will inhibit a reject pulse from occuring. Reject products will be ejected by the output pulse. NOTE: the MAXI-AMP can supply 50mA for external 10 to 30V dc devices. Carefully check the current draw of the devices to be powered by the MAXI-AMP.
WARNING The MAXI-AMP modules described in this data sheet do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A failure or malfunction can result in either an energized or a de-energized output condition.
Never use these products for personnel protection. Their use as safety devices may create an unsafe condition which could lead to serious injury or death. Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 14
MAXI-AMP CL Series
Hookup of Multiple Self-contained Sensors Any number of self-contained dc sensors may be wired together in parallel to a single CL Series MAXI-AMP module to create almost any multiple-sensor logic configuration. Power for the sensors may be obtained from MAXI-AMP 400mA power supply CP12 (shown below) or from 1-amp model PS120-15. The table at the right describes how the four most frequently used multiple-sensor logic configurations may be created. MINI-BEAM SM312 Series and VALU-BEAM SM912 Series sensors have a switch on the back of their housings which is used to program the sensors for LIGHT or DARK operate. MAXI-BEAM sensors are set for LIGHT or DARK operate using the programming ring. MULTI-BEAM sensors are programmed for LIGHT or DARK operate with the logic module jumper wire. OMNI-BEAMs are programmed by a switch in the sensor block.
INVERTING JUMPER Installed Between Module Terminals #10 and #11
LIGHT OPERATE
NO
If any receiver "sees" light
LIGHT "OR"
LIGHT OPERATE
YES
When all receivers "see" dark
DARK "AND"
DARK OPERATE
NO
If any receiver "sees" dark
DARK "OR"
DARK OPERATE
YES
When all receivers "see" light
LIGHT "AND"
(AFTER DELAY, IF ANY)
LOGIC DESCRIPTION
Brown� +V dc
+V dc
For ON/OFF sensor operation, light operate is equated to normally open output, and dark operate is defined as normally closed. EZ-BEAM sensors have both a normally open and a normally closed output. Selection of either output determines the LIGHT/DARK operate mode. ECONO-BEAM sensors are not programmable and must be ordered for LIGHT OPERATE (standard models) or DARK OPERATE (model suffix "NC"). The addition of a jumper wire between MAXI-AMP terminals #10 and #11 changes the input response from a low-going to a high-going signal. This feature, combined with the selection of LIGHT or DARK operate at the sensor, allows "AND" logic with parallel sensor connections.
OUTPUT OCCURS
SENSOR PROGRAM: Light or Dark Operate
4 5 6 7 8
CL3� or � CL5� model
3 2 1 11 10 9
Brown White Blue�SM31R/RL (#1)
SM31E/EL
Brown� +V dc
Blue� (#1) Brown� +V dc
White
105-130V ac 105-130V AC �
4 5 6 7 8
CP12� power supply
3 2 1 11 10 9
Timing Logic Programming (CL5 models)
Settings illustrated below are factory settings. Factory settings are "underlined" in the table.
Blue�SM31R/RL (#1) Brown� +V dc
SM31E/EL
Blue� (#1) Brown� +V dc
White Blue
SM31R/RL
SM31E/EL Blue� (#1)
(NOTE: see page 5 for description of logic functions)
A group of ten switches located on one side of the module is used to select the timing logic for CL5 models. Switches #1 through #7 are used to select the logic function. Switch #8 programs the output for either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10 program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds, and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timing mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However, DELAY and HOLD times are independently adjustable within the selected range.
The diagram shows switch locations, and the table summarizes the program switch positions.
4 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 15
Description of Logic Functions, CL5 models
ON/OFF: ON/OFF operation does not involve timing. The output simply follows the action of the input signal.
Grounding pin #9 (AUXILIARY) turns the output "off", regardless of the state of the input signal. This may be accomplished by closing a switch or relay contact between pins #9 and #1 (common), or by connecting an open collector NPN (current sinking) output of any external dc device directly to pin #9. NOTE: connect the COMMON of any external dc device to pin #1 of the MAXI-AMP to establish a voltage reference between the dc supply for the external device and the internal dc supply of the MAXI-AMP.
ON DELAY: The ON DELAY timer keeps the output "off" until the selected LIGHT or DARK signal has been present for the preset "DELAY" time. If the input signal is interrupted, the timing is reset and starts over with the next signal. Grounding pin #9 immediately cancels an output in progress and resets the delay timer. The delay timer is restarted when the inhibit signal is removed, if an input signal is present.
OFF DELAY: The output energizes immediately when the input signal occurs, but does not de-energize until the signal has been removed for the preset OFF-DELAY ("HOLD") time. Grounding pin #9 prevents an output from occuring. If an inhibit input occurs during an output, the output remains "on" for the remainder of the OFF-DELAY time. ON & OFF DELAY: ON and OFF DELAY logic combines both timing functions into a single mode. The ON-
DELAY ("DELAY") time and the OFF-DELAY ("HOLD") time are independently adjustable within the selected time range. Momentary grounding of pin #9 during the ON-DELAY period resets the DELAY timer. An inhibit signal which occurs during an output will allow the output to stay energized for the remainder of the OFF-DELAY time. ON and OFF DELAY logic is often used in jam and void control, high/low level control, and edge-guiding applications.
ONE-SHOT: The output of a ONE-SHOT function is a pulse of adjustable "HOLD" duration which is independent of the duration of the input signal. With the MAXI-AMP programmed for LIGHT operate, the pulse occurs when the input signal changes from dark to light. In DARK operate, the pulse occurs with a light to dark input transition. Grounding pin #9 prevents the one-shot from triggering, but does not affect a pulse already under way.
DELAYED ONE-SHOT: A DELAYED ONE-SHOT is initiated by either a momentary or maintained input signal. This input starts the adjustable "DELAY" period, after which the output pulses for an adjustable pulse ("HOLD") time. No further action occurs unless the input is removed and reapplied, beginning a new sequence. Grounding pin #9 during the delay period will cancel the sequence, and no output occurs. This feature is often used for inspection/rejection control logic. An inhibit signal will not affect a pulse under way.
LIMIT: The output of the LIMIT function follows the action of the input, as it does with the ON/OFF function. However, an input signal which is longer than the adjustable LIMIT ("HOLD") time will turn the output "off". Removing the input signal resets the timer. This function is sometimes called "TIME LIMITED ON/OFF", and is useful for energy conservation. Grounding pin #9 cancels the output. Lifting the inhibit restarts the LIMIT timer, if an input signal is present.
REPEAT CYCLE: The REPEAT CYCLE function provides an oscillating output when an input signal is present. Presence of an input signal triggers an adjustable "DELAY" timer. After the delay, the output energizes for an adjustable "HOLD" period. If the input remains, the output continues to cycle "on" and "off" at this rate indefinitely. When the signal is removed, any output in progress completes and then remains "off" until the next signal and DELAY period. Grounding pin #9 cancels the sequence, but will allow the completion of a "HOLD" period in progress. Lifting the inhibit signal begins the DELAY period, if an input signal is present. AC LATCH: An AC LATCH is the combination of a ONE-SHOT and a LATCH. A momentary or sustained input will latch the output "on". Grounding pin #9 will reset the latch, even if the input signal remains. The output will not re-latch until the input signal is removed and then reapplied. DC LATCH: The output will latch "on" whenever the selected LIGHT or DARK input condition occurs. Grounding pin #9 of a dc latch will turn the output "off" regardless of the state of the input signal. If the signal is present when the reset is removed, the output will immediately latch "on" again.
DELAY AND LATCH: The DELAY + LATCH is a combination of the ON-DELAY and DC LATCH functions.
An input must be present for at least the adjustable "DELAY" time for the output to latch "on". If the input signal is removed during the timing cycle, the timing is reset. Momentary grounding of pin #9 resets the latch and/or the DELAY timing cycle. Sustained grounding of pin #9 inhibits any output.
LIMIT AND LATCH: The LIMIT + LATCH operates exactly like the LIMIT function, except that the LIMIT ("HOLD") timer can be reset only by the auxiliary input. An output remains latched "off" until reset by momentarily grounding pin #9. In addition to resetting the timer, grounding pin #9 will hold the output "off", regardless of the state of the input signal.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 16
MAXI-AMP System
Mounting and Accessories Panel Wall Mounting of MAXI-AMP Module After the panel cutout has been completed and de-burred, slide the MAXI-AMP through the cutout and place one clip assembly into the rectangular depression on each of the two narrow sides of the housing. Orient clips as shown, and alternately tighten the screws for equal pressure against the inside of the panel wall. Do not overtighten the screws. Attach the optional EC11-6 extension cable (described below) to the MAXI-AMP and route the opposite end of the cable to the RS-11 (or equivalent) socket. Model EC11-6 extension cable is 6 feet (2m) long. Clips for panel wall mounting of the MAXI-AMP are included with the cable.
Accessories for MAXI-AMP Modules Model RS-11 Socket
Model RS-11 is an eleven-pole round-pin screw terminal relay socket which is used to make electrical connections to any MAXI-AMP module. The socket provides in-line wire clamp screw terminals which will accept from one #24 AWG up to two #14 wires at each pin. The RS-11 is UL recognized (file #E92191) and CSA approved (file #LR38486). It may be mounted directly to a panel plate or via standard 35mm DIN-rail track (see below). A holddown wire is supplied with each RS-11 socket (see dimension diagram on page 2). The RS-11 is supplied with a coding ring and pin (see diagram at right). This allows a MAXI-AMP to be keyed to fit only its own 11-pin socket. The pin is installed in one of the eleven slots in the RS-11, and the notch in the ring is aligned to slip over the pin. When the MAXI-AMP is removed from the RS-11, the coding ring stays with the MAXI-AMP base, while the coding pin remains in the socket.
35mm DIN Rail Track
Track model DIN-35-70 accomodates one RS-11 socket. Model DIN-35-105 holds two sockets. Model DIN-35-140 holds up to three sockets. The RS-11 socket is designed to snap (or slide) directly into the 35mm DIN track.
Model BENC-4 Enclosure
Model BENC-4 is a NEMA-4 rated corrosion-resistant enclosure for a MAXI-AMP module or other control device. It is supplied with a DIN-35-70 track for easy mounting of one RS-11 socket. For mounting two sockets, use DIN-35-105.
WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.
Banner Engineering Corp.
9714 Tenth Ave. No. Minneapolis, MN 55441
Telephone: (763) 544-3164
FAX (applications): (763) 544-3573
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 17
MAXI-AMP™ CR Series
Modulated Amplifier Modules for "100 Series" Sensors • Modulated photoelectric amplifier, power supply, output relay, and versatile timing logic (CR5 models) in one compact, stand-alone package
• 120 or 240V ac or 12 to 28V dc operation; requires only the addition of Banner "100 Series" modulated remote sensor(s) to create a complete sensing system
• CR5 models are easily programmed for any of 12 delay, one-shot, and latch functions (single or dual timing); interrogation schemes are possible using the module's auxiliary input
CR Series MAXI-AMPs combine power supply, modulated photoelectric amplifier, timing logic (in CR5 models) and output relay in a single compact, cost-saving module. The integrated stand-alone design saves both the expense of a separate control chassis and a substantial amount of panel space. Several models are available, for either 120V or 240V ac operation, and either with or without timing logic. Altenatively, any model may be powered by 12 to 28V dc. CR Series modules are specifically designed for use with the popular "100 Series" of Banner miniature sensors (page 3). Their rugged encapsulated design, slim ribbon-style connecting cables, and small size make these sensors ideal for use in many situations previously considered impractical or impossible. MAXI-AMP modules themselves are also ruggedly built for dependable industrial duty. CR Series MAXI-AMP modules contain the state-of-the-art Banner custom-designed CMOS modulator/demodulator/amplifier circuit, of-
MODEL
SUPPLY VOLTAGE
CR3RA
105 to 130V ac, or 12 to 28V dc
CR3RB
210 to 250V ac, or 12 to 28V dc
CR5RA
105 to 130V ac, or 12 to 28V dc
CR5RB
210 to 250V ac, or 12 to 28V dc
OUTPUT
LOGIC
SPDT electromechanical relay, plus NPN transistor solidstate DC switch
ON/OFF
SPDT electromechanical relay (5 amp contact rating)
12 timing functions
Model CR5RA shown with SP100C sensor fering high immunity to both ambient light and electrical interference plus reliable sensor performance. All models have Banner's exclusive, patented Alignment Indicating Device (AID™) system, which lights an LED indicator whenever the sensor sees a "light" condition, and pulses the LED at a rate proportional to the received light signal strength. All CR Series modules are programmable for LIGHT or DARK operate and either high or low hysteresis. Input response time may be set at 0.3, 2, or 10 milliseconds. The 10-millisecond response mode offers enhanced immunity to electrical interference ("noise"), and also minimizes optical "crosstalk" between adjacent sensors. CR5 models include a versatile multi-function timing logic circuit which is programmable for 12 of the most popular and useful delay, one-shot, and latch functions. Each timing function has a choice of three time ranges. Timing and sensitivity adjustments are accomplished via rugged 15-turn potentiometers for very accurate settings. CR Series circuitry is designed to prevent false outputs on system power-up. The output circuit for all CR Series modules is an SPDT 5-amp electromechanical relay. Additionally, CR3 models have an NPN transistor solid-state switch. The output may be programmed for either normally open or normally closed operation. A solid-state relay is offered as an option to the electromechanical relay (see below). An auxiliary input is available on CR5 models for interrogation or reset of the selected logic function (see example, page 4). Page 6 describes the function of the auxiliary input for each logic mode. A dc power supply is included for powering an additional self-contained dc sensor. Read Personnel Safety Use WARNING, page 7.
Solid-state Output Option CR Series modules are available with a solid-state relay which replaces the electromechanical relay. This is actually two SPST solid-state contacts. One contact will switch ac loads, and is rated at 250V ac maximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 amp at 50 degrees C). The other solid-state contact will switch dc loads of up to 30V dc and up to 50 milliamps. Both contacts are isolated from the MAXI-AMP power supply.
Printed in USA
MODEL
SUPPLY VOLTAGE
CR3A
105 to 130V ac, or 12 to 28V dc
CR3B
210 to 250V ac, or 12 to 28V dc
CR5A
105 to 130V ac, or 12 to 28V dc
CR5B
210 to 250V ac, or 12 to 28V dc
OUTPUT SPST solidstate contact for switching AC loads up to 250 V ac and up to 3/4 amp, plus solid-state contact for switching DC loads up to 30V dc and up to 50mA.
LOGIC ON/OFF
12 timing functions
P/N 03452C4D
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 18
MAXI-AMP CR Series Specifications SUPPLY VOLTAGE: Models CR3(R)A, and CR5(R)A: 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA. Models CR3(R)B, and CR5(R)B: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA. *NOTE: do not connect ac power if using external dc power.
Functional Schematics CR5 Models
OUTPUT CONFIGURATION:
Models CR3A, CR3B, CR5A, CR5B have an SPST solid-state relay for switching ac or dc (see page 1). Models CR3RA, CR3RB, CR5RA, CR5RB have an SPDT electromechanical (e/m) relay with the following ratings: CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load), 1/10 H.P. at 240V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. CONTACT RESPONSE: 10 milliseconds max. open/close; 20 operations/second max. MECHANICAL LIFE: 20,000,000 operations CR3 models also have a logic level current sinking NPN transistor switch at pin #9. See schematic (right) and hookup info.
AMPLIFIER:
RESPONSE SPEED: programmable for 10, 2, or 0.3 milliseconds. NOTE: use 10 millisecond setting whenever possible for enhanced noise rejection. HYSTERESIS: if programmed "HIGH", approximately 20%; if programmed "LOW", approximately 5%. NOTE: see cautions for "LOW" setting (see page 5). MODULATION FREQUENCY: approximately 10kHz.
SENSOR LEAD LENGTH: 50 feet (15 m) maximum. Use separate shielded cable for emitter and receiver, or order sensors with extended cable length. NOTE: see splicing precautions.
MULTIPLE SENSOR HOOKUP: Up to three sensors may be wired together to one CR Series amplifier for "OR" operation (in LIGHT operate) or "NAND" operation (in DARK operate). Emitters are connected in series, and receivers are connected in parallel. When wiring two sensors to one MAXIAMP, multiply excess gain data for each sensor by 1/2 (obtain data from applicable excess gain curve). When wiring three sensors to one MAXI-AMP, multiply excess gain by 1/3.
NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device (see hookup example, page 4). Current available is 40 mA at 120V ac (240V ac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power. NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latch of CR5 model (see "Description of Logic Functions", page 6).
CR3 Models
TIMERS (CR5 models only): TIMING RANGES:
REPEATABILITY:
LOW range - 10 to 150 milliseconds MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds +/-2% of set time over all extremes of supply voltage and temperature
ADJUSTMENTS: Miniature switches for programming of LIGHT/ DARK operate, amplifier response time, amplifier hysteresis, normally open or normally closed output, and timing function (CR5 models). 15-turn clutched potentiometer for gain and time setting(s) (CR5 models). OPERATING TEMPERATURE: 0 to 50°C (32 to 122°F). INDICATOR LEDs: Red indicator LED is "ON" when the module output is energized. Exclusive Banner Alignment Indicating Device (AID™) system lights a red LED indicator whenever the receiver "sees" its own modulated light source, and pulses it at a rate which is proportional to the strength of the received light signal.
CONSTRUCTION: Rugged NORYL® polyphenylene oxide (PPO®) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base.
NOTE #3: pin #9 of CR3 model may be connected directly to the AUXILIARY input of a MAXI-AMP or Banner M Series module. It may also serve as the input to Banner CL series MAXI-AMPs or to Banner Plug Logic modules.
Dimension Drawing
Generalized Hookup
CR3RA CR3RB CR5RA CR5RB NOTE: If MAXI-AMP is powered by a dc power supply, connect +12 to 28V dc @ ≥70mA to terminal #3 and dc common to terminal #1. Make no connections to terminal #7 or #8.
2
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 19
Sensors for use with CR Series Modulated Amplifier Modules Temperature range for all miniature modulated remote sensors is 0 to 70 degrees C (+32 to 158 degrees F). Sensors are epoxy-encapsulated and optics are hermetically sealed.
Models/Dimensions SP100E & SP100R Range: 8 inches (20cm) Beam: infrared, 880nm Effective beam: .05 inch (1,3mm diameter)
Excess Gain
Beam Pattern
OPPOSED Mode Sensors SP100E and SP100R miniature opposed sensors have a slim right-angle design which allows them to be mounted in very tight locations. The thin, flexible ribbon cable which exits from one corner may be run in any direction away from the sensing point. The SP100E and R have a wide beam angle for forgiving line-of-sight alignment. Alignment is easily made exact (and monitored) using the AID™ LED on the CR module.
Cable (all 6-foot lengths): SP100E: 2-wire ribbon cable (white, green). SP100R: 3-wire ribbon cable (red, black, yellow). SP100D, DB, C, CCF: 5-wire ribbon cable (white, green, red, black, yellow). See hookup drawing, page 4.
SP100D
SP100DB
DIFFUSE Mode Sensors
Models SP100D and SP100DB are general-purpose miniature diffuse sensors which detect the reflection of their own light from the surface of an object. The SP100D is a right-angle design which is generally held in place using a #4 (3mm) screw. The SP100DB ("B" = Barrel) is an in-line threaded barrel which typically mounts through a 3/8" (10mm) diameter hole using the lock nuts which are supplied. The optical response of these two sensors is the same.
SP100C
SP100CCF
CONVERGENT Mode Sensors
Models SP100C and CCF are ideally suited to applications where depth of field is critical. The emitter and receiver are both directed at a point 0.1 inch (2,5mm) ahead of the front surface. An aperture is included which, when attached, narrows the depth of field (see curves, below). This is particularly useful when it is necessary to detect an object while ignoring another object or a surface just a fraction of an inch farther away. The high excess gain at the focus allows detection of objects of low reflectivity. The SP100C and CCF differ only in housing style. Model SP100C is for general application. Model SP100CCF is used where a narrow profile is important for mounting.
3