Manual · Banner
MAXI-AMP System
Manual58 pagesPDF 9.8 MB
Collected Banner MAXI-AMP data sheets: CL, CM, CR and CD series sensor control modules, CP power supplies, sensors and accessories.
Covers · 2 models
The models it covers
Summary
What is in it
A collection of Banner Engineering data sheets for the MAXI-AMP system of stand-alone sensor control modules. It covers the CL series logic-level input modules (including the CL5RA with timing logic), the CM series modulated amplifier modules (including the CM5RA), the CR and CD series, CI3RC current trip point modules, CP series power supply modules and the OC-12 optical coupler, with specifications, sensor hookup diagrams, logic function descriptions, amplifier programming, mounting and accessories. Some pages are scans with no readable text.
From the manual
Key facts from this manual
Each line names its page in the PDF.
Banner MAXI-AMP system catalog: a set of data sheets for MAXI-AMP modules and related parts, such as the CP Series power supplies and the OC-12 optical coupler. It includes the CL Series logic-level input modules (among them the CL5RA) and the CM Series modulated amplifier modules (among them the CM5RA), with their specifications, hookup notes and timing options.
- Supply voltage
- 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc (CL5RA at 60mA, CM5RA at 70mA) p. 12, 43
- Relay output
- SPDT electromechanical relay: 250V ac max, 24V dc max, 5 amps max resistive, 1/10 H.P. at 240V ac p. 12, 43
- Timing
- 12 delay, one-shot and latch functions; ranges 10 to 150 milliseconds, 0.1 to 1.5 seconds, 1 to 15 seconds; +/-2% repeatability p. 11, 12
- Relay life
- 10 milliseconds max closure and release; 20 operations/second max; 20,000,000 operations mechanical life p. 12
- Housing
- NORYL PPO housing, 1.6" x 2.3" x 4", standard round-pin 11-pole plug base p. 12
- Operating temperature
- 0 to 50 degrees C (32 to 122 degrees F) p. 12
- CL5RA input
- CL5RA: logic-level input from NPN (current sinking) dc sensors, MAXI-AMP, MICRO-AMP and Plug Logic modules, limit switches or contact closures p. 11
- CL5RA switching
- CL5RA: input switches when pin #2 drops below 1V dc or under 1K ohms to pin #1; 1 millisecond response p. 12
- CL5RA sensor power
- CL5RA: 50mA at 120V ac line (40mA at 105V ac) for an external 10 to 30V dc device p. 12
- CM5RA amplifier
- CM5RA: modulated amplifier for Banner modulated remote sensors; response 0.3, 2 or 10 milliseconds; hysteresis about 20% (high) or 5% (low) p. 42, 43
- CM5RA sensors
- CM5RA: sensor leads 50 feet (15 m) maximum; up to three sensors on one amplifier p. 43
- CM5RA sensor power
- CM5RA: 40 mA at 120V ac line (30mA at 105V ac) for an external 10 to 30V dc device p. 43
- Solid-state option
- Optional solid-state relay: ac contact 250V ac, 3/4 amp at 25 degrees C (1/2 amp at 50 degrees C); dc contact 30V dc, 50 milliamps p. 11
- Adjustments
- Miniature switches and 15-turn clutched potentiometers (CM5RA: also gain) p. 12, 43
What this manual walks you through
- Setting the timing function, time range and output polarity p. 12
- Powering the module from 12 to 28V dc instead of ac p. 12
- Inverting the CL input with a jumper p. 12
- Using pin #9 to inhibit timing or reset a latch p. 12
- Wiring several switched devices to one CL input p. 12
- Wiring up to three sensors to one CM amplifier p. 43
- Reading signal strength with the AID alignment indicator p. 43
Good to know
- Do not connect ac power while the module runs on external dc power. p. 12
- Fit an MOV transient suppressor across relay contacts that switch inductive loads. p. 12
- On CM modules use the 10 millisecond response whenever possible for better noise rejection. p. 43
- With two or three sensors on one CM amplifier, multiply each sensor's excess gain by 1/2 or 1/3. p. 43
- With the solid-state option, ac loads may take up to 1/2 cycle (8.3 milliseconds) to turn off. p. 11
Questions this manual answers
What voltage does the Banner CL5RA use?
105 to 130V ac at 50/60Hz, or 12 to 28V dc at 60mA. p. 12
What is the relay rating of the CL5RA and CM5RA?
An SPDT relay rated 250V ac or 24V dc maximum, 5 amps resistive, 1/10 H.P. at 240V ac. p. 43
What timing ranges does the CM5RA offer?
10 to 150 milliseconds, 0.1 to 1.5 seconds and 1 to 15 seconds, repeatable to +/-2%. p. 43
How long can the sensor leads be on a CM5RA?
Up to 50 feet (15 m). p. 43