The text of a manual · part 7 of 7
MAXI-AMP System, pages 54 to 58
Pages 54 to 58 of 58
The original document is the PDF (9.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Banner CL5RA and Banner CM5RA
Page 54
MAXI-AMP™ System CP Series Power Supply Modules MODEL
INPUT VOLTAGE
CP12C
105 to 130V ac (15 VA) or
CP12RC
MAXI-AMP CP Series power supply modules provide a convenient source of power for 10 to 30V dc sensing devices such as Banner selfcontained dc sensors and/or any of the Banner logic modules and remote amplifiers. It is an excellent way to supply power to a system using multiple MAXI-AMP modules and associated sensors.
210 to 250V ac (15 VA) 50/60Hz
OUTPUT POWER
OUTPUT DEVICE
400 milliamps maximum for 10-30V dc sensing devices
None
SPDT 5-amp electromechanical
Model CP12RC includes a relay which may be switched by the output of dc sensors or modules. The relay is a single-pole double-throw (SPDT) 5 amp electromechanical type.
Load Curve
Dimensions
120V ac Hookup Diagram, CP12C
120V ac Hookup Diagram, CP12RC 4
CR
7 8
SOURCING INPUT
+12V
5 6
105 to 130V ac
CR
CP12RC
+V output (see load curve) SINKING INPUT dc COMMON RELAY OUTPUT 5 AMP CONTACTS
220/240V ac Hookup Diagram, CP12RC 4
CR
7 8
SOURCING INPUT
+12V
5 6
210 to 250V ac
CR
CP12RC
9 10 11 1 2 3
220/240V ac Hookup Diagram, CP12C
9 10 11 1 2 3
These supplies are designed for either 120 or 220/240V ac input voltage (see hookup diagrams). They offer 400 milliamps for powering 10 to 30V dc devices.
CP series power supplies are built into the rugged MAXI-AMP housing. They connect via a standard 11-pole round-pin relay socket (Banner RS-11). The RS-11 socket allows DIN rail mounting of the power supply. Operating temperature for CP series power supply modules is 0 to 50 degrees C (32 to 122 degrees F).
+V output (see load curve) SINKING INPUT dc COMMON RELAY OUTPUT 5 AMP CONTACTS
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 55
MAXI-AMP System Mounting and Accessories Panel Wall Mounting of MAXI-AMP Module After the panel cutout has been completed and deburred, slide the MAXI-AMP through the cutout and place one clip assembly into the rectangular depression on each of the two narrow sides of the housing. Orient clips as shown, and alternately tighten the screws for equal pressure against the inside of the panel wall. Do not overtighten the screws. Attach the optional EC116 extension cable (described below) to the MAXI-AMP and route the opposite end of the cable to the RS-11 (or equivalent) socket. Model EC11-6 extension cable is 6 feet (2m) long. Clips for panel wall mounting of the MAXI-AMP are included with the cable.
Accessories for MAXI-AMP Modules Model RS-11 Socket Model RS-11 is an eleven-pole round-pin screw terminal relay socket which is used to make electrical connections to any MAXI-AMP module. The socket provides in-line wire clamp screw terminals which will accept from one #24 AWG up to two #14 wires at each pin. The RS-11 is UL recognized (file #E92191) and CSA approved (file #LR38486). It may be mounted directly to a panel plate or via standard 35mm DIN-rail track (see below). A hold-down wire is supplied with each RS-11 socket (see Dimension Diagram on page 22). The RS-11 is supplied with a coding ring and pin (see diagram at right). This allows a MAXI-AMP to be keyed to fit only its own 11-pin socket. The pin is installed in one of the eleven slots in the RS-11, and the notch in the ring is aligned to slip over the pin. When the MAXI-AMP is removed from the RS-11, the coding ring stays with the MAXI-AMP base, while the coding pin remains in the socket.
35mm DIN Rail Track
Model BENC-4 Enclosure
Track model DIN-35-70 accomodates one RS-11 socket. Model DIN-35-105 Model BENC-4 is a NEMA-4 rated corrosion-resistant enclosure for a MAXIholds two sockets. Model DIN-35-140 holds up to three sockets. The RS-11 AMP module or other control device. It is supplied with a DIN-35-70 track for easy mounting of one RS-11 socket. For mounting two sockets, use DIN-35-105. socket is designed to snap (or slide) directly into the 35mm DIN track.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
23
Page 56
Accessories for High Performance Modulated Remote Sensors Extension Cable Modulated remote sensors require specially designed cable for efficient sensor performance. Extension cable is available in 100 foot (30m) lengths.
Extension Cable Model
Used on Sensor Models
# of Wires
EC12E-100
SP12SEL, SP12PEL
2
White, Green
EC12R-100
SP12SRL, SP12PRL
3
Black, Blue, Brown
ESC-100
PT200, PT250, PT400, SP300RL LR200, LR250, LR400, SP300EL
3
White, Green, Shield
3
Red, Black, Shield
5
White, Green, Red, Black, Shield
RSC-100
Wire Colors
EC300E-100
SP300D, SP300L, LP400WB, SP1000V LR300
2
White, Shield
EC300R-100
PT300
2
Red, Shield
EC320-100
SP320D
4
White, Shield, Red, Shield
SSC-100
Compression Fittings used to Attach Protective Tubing to Remote Sensors Cable Protection AC-6 6 feet (1,8m) AC-30 30 feet (9m)
PVC-6 6 feet (1,8m) PVC-30 30 feet (9m)
This is mild-steel flexible tubing used with the compression fittings, at right, to achieve maximum protection to sensor cables. I.D. = 5/16"; O.D. = 7/16".
Heavy duty PVC tubing used to protect sensor cable in applications involving moisture and/or corrosive materials. I.D. = 1/4"; O.D. = 3/8".
!
CF3-8 3/8"-32 thread CF7-16 7/16"-20 thread
Compression Fitting Model
Used to Attach Tubing to these Models
CF3-8
LR400, PT400, LP400WB
CF7-16
SP300EL, SP300RL,SP300D,SP300L, LR200, PT200
WARNING MAXI-AMP sensors, amplifiers, and logic modules do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either an energized or a de-energized output condition. Never use any MAXI-AMP product as a sensing device for personnel protection. Its use as a safety device may create an unsafe condition which could lead to serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection.
WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 57
Trip MAXI-AMP™ CI3RC2 Current Point Module for SMI Series intrinsically safe sensors
• Self-contained current sensing amplifier • Works with intrinsically safe barrier to provide power to • • •
Banner SMI Series intrinsically safe DC sensor(s); converts input signal from the sensor to a contact closure Powers a single sensor or both the emitter and receiver of an opposed mode pair Powered by 105-130 or 210-250V ac (50/60Hz) Two output devices: SPDT 5 amp electromechanical relay and opto-isolated transistor for logic level dc switching
CI3RC2 module (left) shown with RS-11 socket and DIN rail; also SMI30 Series emitter/receiver pair and intrinsic safety barrier.
The Banner MAXI-AMP model CI3RC2 (p/n 36606) is a selfcontained module which converts the current output signal of an SMI Series intrinsically safe sensor to a trip point switch. Banner SMI Series intrinsically safe sensors carry Factory Mutual Research's rating for use in hazardous areas. Sensors are wired to model CI3RC2 using the two-wire hookup through an intrinsically safe barrier. Refer to the hookups, page 2. The SMI Series sensor sinks ≤10 milliamps in the "OFF" state and ≥20 milliamps in the "ON" state. The CI3RC2 module senses this current change and switches internal relays that may be easily wired to most loads and/or additional control circuitry. Model CI3RC2 is powered by either 105-130 or 210-250V ac. It supplies dc power to operate a single sensor or both the emitter and receiver of one SMI Series opposed mode sensor pair. The sensor's input to the CI3RC2 is protected against short circuits.
SPECIFICATIONS SUPPLY VOLTAGE: 105 to 130 or 210 to 250V ac, 50/60 Hz (8VA) OUTPUT CONFIGURATION: SPDT electromechanical relay: Contact rating: 250V ac maximum, 24V dc maximum, 5 amps maximum (resistive load), 1/10 HP at 240V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. Closure time: 10 milliseconds maximum. Release time: 10 milliseconds maximum. Maximum switching speed: 20 operations/second. Mechanical life: 20,000,000 operations Solid-state dc relay: SPST optically-coupled transistor; 30V dc maximum, 20mA maximum.
DIMENSION DRAWING
Printed in USA
Built-in circuit diagnostics indicate an input overload by flashing an LED status light. The MAXI-AMP CI3RC2 module has two isolated output switches. There is a 5-amp rated SPDT electromechanical relay, and a solid-state transistor switch which may be used for logiclevel interfaces. Banner also offers the CI3RC2 Current Trip Point Module as part of a kit. See page 2 for further information. The CI3RC2 may be used with the following Banner Intrinsically Safe sensors: SMI30 Series, SMI912 Series.
EMITTER POWER: +24V dc at 25 mA maximum available at module pin #3. INPUTS: Trip point for output "OFF": ≤10 milliamps Trip point for output "ON": ≥20 milliamps Trip point range for input overload indication: 30mA ≤ I ≤ 80mA. INDICATOR LEDs: OUTPUT "ON" and INPUT overload/short. OPERATING TEMPERATURE: 0 to 50°C (32 to 122°F). CONSTRUCTION: rugged NORYL® polyphenylene oxide (PPO®) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole base. Use RS-11 socket or equivalent.
FUNCTIONAL SCHEMATIC
P/N 36611 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 58
WARNING This photoelectric sensing product does NOT
GENERALIZED HOOKUP, CI3RC2 OUTPUT RELAY 250V ac max. 24V dc max. 5A max.
4
3
AUX. INPUT
5
2
INPUT
6
1
COMMON
7
11
8
10
OUTPUT 30V dc max. 20 mA max.
110V ac AC SUPPLY 8 VA 50/60 Hz
! condition.
Never use this product as a sensing device for personnel protection. Its use as a safety device may create an unsafe condition which could lead to serious injury or death. Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection.
9
220V ac include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A failure or malfunction can result in either an energized or a de-energized output load which draws up to 5 amps (see specifications). The SPST solid-state relay can switch a dc load of up to 30V dc, max.; 20mA, max.
SMI Series sensors are certified intrinsically safe ONLY when used with certified energy-limiting intrinsically-safe barriers. Banner does not itself manufacture intrinsically-safe barriers. Barriers may, however, be purchased from Banner. Kit CI2BK-1 includes one each of the following: single channel barrier, CI3RC2 amplifier, RS-11 socket, DIN rail mount, and a 70 mm DIN rail for mounting the socket. Kit CI2BK-2 provides a dual channel barrier in place of the single channel barrier. Barriers are available separately (below right).
SMI Series emitter-only units also use the 2-wire hookup through a barrier (see hookup diagram "B"). Emitter power (24V dc, 25 mA maximum) is obtained at pin #3. This is sufficient to power one emitter. The user of this equipment is responsible for the proper installation and maintenance of the equipment, and must conform with certification requirements relating to barriers and to maximum allowable capacitance and inductance of field wiring. If you have questions about these requirements, Banner applications engineers can refer you to the proper authority.
An SMI Series sensor is wired through a barrier using the 2-wire hookup. In the 2-wire hookup configuration, the sensor acts as a current sink, drawing less than 10mA in the OFF state and more than 20mA in the ON state. Model CI3RC2 senses this current change and switches internal relays. The SPDT electromechanical relay in the CI3RC2 can switch a
HOOKUP DIAGRAM A: Hookup of SMI Series Intrinsically Safe Sensor to CI3RC2 (except emitter - see below)
Kits for use with Intrinsically Safe Sensors
SAFE AREA HAZARDOUS AREA
4
9 10 11 1 2 3
BLACK
105 to 130V ac AC SUPPLY
5 6 7 8
RELAY OUTPUT 5 AMP CONTACTS
CI3RC2
INPUT
INPUT: ≤10 MA. (OFF STATE) ≥20 MA. (ON STATE)
1
IN
+
COMMON
+
-
OPTO-COUPLER OUTPUT: 20mA max.
OUT BROWN 2
V
-
3
SMI Series Sensor
BLUE
I.S. BARRIERG
210 to 250V ac
BOTTOM VIEW OF CABLE CONNECTOR ON SENSOR (colors shown are for mating cable model MBCC-312)
BUSBAR
G EARTH GROUND (less than 1Ω)
SAFE AREA
HOOKUP DIAGRAM B: Hookup of SMI Series Intrinsically Safe Emitter/receiver pair to CI3RC2
HAZARDOUS AREA 1
IN
+
Dual Barrier +
OUT
BROWN 2
4
105 to 130V ac AC SUPPLY
5 6 7 8
RELAY OUTPUT 5 AMP CONTACTS
CI3RC2
9 10 11 1 2 3
NOTE: Two single channel barriers may be used in lieu of one dual INPUT: ≤10 MA. (OFF STATE) channel barrier. ≥20 MA. (ON STATE) AUX.
3
SMI Series Emitter
I.S. -
Barriers are available separately:
BLUE IN
+
OUT
BLACK 1
INPUT BROWN
COMMON
2
OPTO-COUPLER OUTPUT: 20mA max.
3
SMI Series Receiver
BUSBAR
G
210 to 250V ac EARTH GROUND (less than 1Ω)
Kit CI2BK-2 (p/n 36605), one each: Dual-channel barrier CI3RC2 amplifier RS-11 socket DIN rail mount 70 mm DIN rail
BLUE
-
+
Kit CI2BK-1 (p/n 36860), one each: Single-channel barrier CI3RC2 amplifier RS-11 socket DIN rail mount 70 mm DIN rail
BOTTOM VIEW OF CABLE CONNECTOR ON SENSOR (colors shown are for mating cable model MBCC-312)
Single channel barrier: CIB-1 (p/n 27030) Dual channel barrier: CI2B-1 (p/n 36865)
WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for a period of one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp., 9714 10th Ave. No., Minneapolis, MN 55441 Telephone (612) 544-3164
FAX (Applications): (612) 544-3573
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com