Amplifier Programming (all models) Amplifier response conditions may be programmed via the group of four switches located on one of the narrow sides of the MAXI-AMP module. Switch #1 selects the amount of amplifier hysteresis. Hysteresis is the amount of signal change beyond the switching threshold which is required to cause the amplifier output to change state, and is expressed as a percent of amplifier gain. The NORMAL setting of 20% should always be used, except for low contrast situations such as many color registration applications.
ON 1
O F F
NOTE: the LOW hysteresis setting should be used only when all sensing conditions remain stable. "Buzzing" of the output (in ON/ OFF and LIMIT operation) or false outputs (in DELAY, ONESHOT, or LATCH operation) may occur if sensing variables (e.g.web flutter) result in optical contrast approaching unity. Switches #2 and #3 are used to program the amplifier response time. The 10 millisecond setting should be used whenever possible for the greatest immunity to electrical interference ("noise"). The 2 millisecond setting has more interference rejection than the 0.3 millisecond mode. Sensor performance (excess gain) is identical in all three response settings.
Factory settings shown at left. "Underlined" settings in table below are factory settings.
2 3
Switch #4 is used to select LIGHT OPERATE or DARK OPERATE. In the LIGHT OPERATE mode, the output will energize (in ON/OFF or LATCH operation) or the timing function will initiate (in DELAY, ONE-SHOT, or LIMIT operation) when the receiver "sees" sufficient light (excess gain greater than 1X). In DARK OPERATE, the output will energize or timing will begin when the receiver is sufficiently dark (excess gain less than 1X).
4
AMPLIFIER PROGRAMMING Normal hysteresis (20%)
SWITCH
SWITCH
#2
#3
#4
10 millisecond response
OFF
ON
2 millisecond response
ON
ON
0.3 millisecond response
ON
OFF
Low hysteresis (5%)
SWITCH SWITCH
#1 ON OFF
The diagram at the left shows the location of switches 1-4, and the table summarizes the settings required for each response condition.
Light operate
ON
Dark operate
OFF
NOTE: an adhesive-backed mylar label is supplied, which may be marked to indicate switch programming and then applied to the MAXI-AMP housing as a switch cover.
Timing Logic Programming (CM5 and CR5 models) Settings illustrated below are factory settings. Factory settings are "underlined" in the table. TIMING LOGIC PROGRAMMING
ON O F F
1
SWITCH SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
OFF
OFF
1.5 Sec. Max. Time
ON
OFF
15 Sec. Max. Time
OFF
ON
On/Off
ON
ON
ON
OFF
ON
OFF
ON
2
On Delay
ON
ON
OFF
OFF
ON
OFF
ON
3
Off Delay
ON
OFF
ON
OFF
ON
OFF
ON
4
On and Off Delay
ON
OFF
OFF
OFF
ON
OFF
ON
One-shot
OFF
OFF
ON
OFF
ON
OFF
ON
Delayed One-shot
OFF
OFF
OFF
OFF
ON
OFF
OFF
Limit
ON
ON
OFF
OFF
OFF
OFF
ON
Repeat Cycle
ON
OFF
OFF
ON
ON
OFF
ON
AC Latch
OFF
ON
ON
OFF
ON
ON
ON
DC Latch
ON
ON
ON
OFF
ON
ON
ON
Delay and Latch
ON
ON
OFF
OFF
ON
ON
ON
Limit and Latch
ON
ON
OFF
OFF
OFF
ON
ON
5 6 7 8 9 10
A group of ten switches, located on the side of the module opposite the amplifier program switches, is used to select the timing logic for the CM5 and CR5 models. Switches #1 through #7 are used to select the logic function. Switch #8 programs the output for either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10 program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds, and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timing mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However, DELAY and HOLD times are independently adjustable within the selected range.
12
N/C Output
OFF
N/O Output
ON
.15 Sec. Max. Time
The diagram shows switch locations, and the table summarizes the program switch positions.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 45
MAXI-AMP System Sensors for use with CM Series Modulated Amplifiers Sensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order. Sensor accessories are shown on page 24.
Models/Dimensions OPPOSED Mode
Excess Gain 1000
E X C 100 E S S
ALL MODELS: Range: 8 feet (2,4m) Beam: infrared, 880nm Effective Beam: .14 inch (3,6mm) dia.
LR/PT200, 250, 300, & 400
G A 10 II N
LR models are emitters PT models are receivers
Beam Pattern
1 .1 FT
12 8 I N 4 C 0 H E S 4
LR/PT200, 250, 300, 400
8 12 0 1 FT
10 FT
100 FT
2
4
6
8
10
OPPOSED DISTANCE--FEET
DISTANCE
LR200 & PT200
LR250 & PT250
LR300 & PT300
LR400 & PT400
Temp. range: -40 to +100 degrees C Housing material: black Delrin®
Temp. range: -40 to +100 degrees C Housing material: black Delrin®
Temp. range: -40 to +80 degrees C Housing material: black VALOX®
Temp. range: -40 to +100 degrees C Housing material: anodized alum.
LR/PT200, 250, 300, and 400 opposed mode remote sensors are identical electronically and optically, and differ only in their housings. All are totally epoxy-encapsulated and use hermetically sealed glass lenses to eliminate condensation inside the optical chamber. These sensors may be washed down without damage. Operating temperature is determined by the type of cable used (see specifications above). These sensor pairs feature wide beam angle for forgiving line-of-sight alignment. At the same time, the effective beam of each pair is only 1/8 inch, allowing small-profile resolution and reliable response to fastmoving objects. LR models are emitters; PT models are receivers. LR200 & PT200: this is a right-angle design which mounts through a 7/16 inch (12mm) diameter hole, using the steel jam nut which is included. This pair is used most commonly on small conveyors when it is desireable to run the cable directly down to a wireway.
LR & PT300: this is a miniature right-angle design which is mounted in place using two #4 screws. This pair uses a very flexible, low-profile 2-wire cable. Despite their small size, the optical performance of the LR/PT300 is equal to the other remote sensor pairs. LR400 & PT400: the 3/8 inch (9,5mm) diameter threaded barrel design makes the LR/PT400 the most versatile and most popular remote opposed sensor pair. They are easily mounted through clearance holes using the jam nuts which are supplied. They may be used with optional L4 or L16 lenses for extended range and/or higher excess gain. The addition of an L4 lens on both the LR and PT400 will increase their range from 8 feet to 40 feet and increase the excess gain at any distance by a factor of 25X. A pair of L16 lenses will increase available excess gain by a factor of 250X. L4 lens
L16 lens
LR250 & PT250: these sensors feature a 1/4 inch (6,4mm) diameter smooth barrel design, and are usually held in place in a clearance hole with a small set-screw. Optional mounting blocks (shown below) are available. Model SMB250 holds the sensor in place with two setscrews. The block is then mounted to a bracket (like model SMB300, page 15), or directly to a machine frame with two #6 screws. Block model SMB250C holds an LR & PT250 together to converge at approximately 1/2 inch ahead of the block.
The LR/PT400 pair is often used at close range with optional AP400 aperture assemblies to create a very small and well-defined effective beam for resolving small profiles, increasing sensing repeatability, or easing response time requirements.
SMB250
AP400 apertures
SMB250C
Aperture model AP400-010 AP400-015 AP400-040 AP400-030R
Aperture size .010" dia. .015" dia. .040" dia. .030" x .125"
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
13
Page 46
MAXI-AMP System Sensors for use with CM Series Modulated Amplifiers Sensors are epoxy-encapsulated. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order. Sensor accessories are shown on page 24.
Models/Dimensions SP300EL & SP300RL
Beam Pattern
Excess Gain
Range: 50 feet (15m) Effective Beam: .5 inch (13mm) dia. Temp. range: -40 to +100 degrees C Housing material: anodized aluminum
Long Range OPPOSED Mode
1000
G A 10 II N
SP300EL/RL
18
E X C 100 E S S
12 I N C H E S
SP300EL/RL
6 0 6 12 18
1 .1 FT
0 1 FT
10 FT
100 FT
10
20
30
40
50
OPPOSED DISTANCE --FEET
DISTANCE
Emitter-receiver pair SP300EL/RL are extremely rugged and are totally encapsulated in anodized aluminum housings. The threaded hub at the cable exit allows for the use of flexible armored cable or protective PVC tubing with the addition of compression gland model CF7-16 (page 24). This pair uses
SP300L
Range: 15 feet (4,5m) with BRT-3 retroreflector Temp. range: -40 to +80 degrees C Housing material: blue anodized aluminum collimating lenses to increase range. These sensors should also be used at short ranges for their high excess gain or to avoid optical "crosstalk" in situations which require several pairs to be mounted adjacent to one another.
RETROREFLECTIVE Mode NOTE: for complete information on retroreflective materials, see Banner catalog. 1000
E X C 100 E S S
SP300L
6 with BRT-T tape with BRT-3 target
G A 10 II N
4 I N 2 C H 0 E S 2
SP300L with BRT-3 reflector
4 with BRT-1 target
1 .1 FT
6 0
1 FT
10 FT
100 FT
4 8 12 15 DISTANCE TO REFLECTOR--FEET
18
DISTANCE
Model SP300L is a remote retroreflective sensor with the same rugged design as the SP300EL/RL, described above. Its useable range is from 6 inches to 15 feet (0,2 to 4,5m) using the model BRT-3 retroreflector.
LP400WB Range: 3 inches (76mm) Temp. range: -40 to +80 degrees C Housing material: blue anodized aluminum
DIVERGENT Mode
If the object that is to break the beam has a shiny surface, then the SP300L and its retroreflector should be mounted so that the beam is at an angle of 10 degrees or more to that surface in order to eliminate false signals which are caused by proxing.
1000
LP400WB E X C 100 E S S
14
1.0 I N .5 C H 0 E S .5
G A 10 II N 1 .1 IN
"WB" in this model number designates "wide beam". The LP400WB is an infrared divergent mode (wide angle diffuse mode) sensor which is particularly
1.5
Range based on 90% reflectance white test card
LP400WB
1.0 1.5
1 IN 10 IN DISTANCE
100 IN
0 1 2 3 4 5 DISTANCE TO 90% WHITE TEST CARD--INCHES forgiving for reflectively sensing transparent or translucent materials or for sensing objects with irregular surfaces (e.g.- webs with "flutter"). The optics are such that even small threads or wires .005" (0,1mm) or greater in diameter may be detected when they pass within .25" (6mm) of the sensor's plastic lens. Due to its wide response pattern, the LP400WB should not be used for precise positioning control, nor should it be mounted with its lens recessed into a hole.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 47
MAXI-AMP System Sensors for use with CM Series Modulated amplifiers Sensors are epoxy-encapsulated. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order. Sensor accessories are shown on page 24.
Models/Dimensions SP300D
SP320D
Range: 12 inches (30cm) Temp. range: -40 to +80 degrees C Housing material: green anodized aluminum
Range: 12 inches (30cm) Temp. range: -40 to +80 degrees C Housing material: black VALOX®
Beam Pattern
Excess Gain DIFFUSE Mode 1000
E X C 100 E S S
SP300D, SP320D
.6 I N .2 C H 0 E S .2
G 10 A II N 1 .1 IN
SP300D, 320D
.4
.4 .6
1 IN
10 IN
100 IN
0 3 6 9 12 15 DISTANCE TO 90% WHITE TEST CARD--INCHES
DISTANCE
SP300D: the SP300D is the diffuse mode version of the SP300L with the same rugged aluminum housing and totally encapsulated construction. The glass lenses are hermetically sealed, which eliminates any possibility of condensation inside the lenses and allows operation in adverse environments like steam washdown and high vibration. The SP300D may be mounted by its through-holes or with the SMB300 bracket, as shown below. SP320D: model SP320D is identical to the SP300D, except for its housing. The 320 is a miniature plastic package, designed to fit into very tight locations. It mounts using two #4 (3mm) screws. The SP320D and the SP300D are excellent for nearly any presence sensing application.
SMB300 UNIVERSAL MOUNTING BRACKET for SP300 Sensors
Accessory bracket model SMB300 is designed for 2-axis universal mounting of sensor models SP300EL, SP300RL, SP300L, and SP300D. These sensors are affixed to the SMB300 with two #6 (3,5mm) screws. The bracket, in turn, mounts with two #10 (5mm) screws. In addition, as indicated by the dimension drawing, the SMB300 has a clearance slot for mounting LR400, PT400, and LP400WB barrel sensors. LR & PT200 sensors may be mounted with the SMB300, using its 7/16-20 threaded hole and steel jam nut, which is supplied with the sensors. LR250 and PT250 sensors may be used with the SMB300 when the SMB250 block is used (see page 13). Also, two SMB250 blocks may be attached to the SMB300 bracket and angled to mechanically converge an LR & PT250 sensor pair.
SP1000V
CONVERGENT Mode
Range: focus at 3.8 inches (96mm) Temp. range: -40 to +80 degrees C Housing material: black anodized aluminum
The SP1000V is a convergent mode sensor that produces a very small 0.1 inch (2,5mm) diameter sensing image at a point exactly 3.8 inches (96mm) from its glass lenses. As the excess gain curve illustrates, the SP1000V has a very sharp drop-off of gain beyond the focus point. This feature makes it an excellent choice for detecting a small part which is only a fraction of an inch in front of another surface, such as parts on a conveyor (viewed from above). It is also ideal for fill level detection and for precise positioning control, in lieu of opposed sensing. 1000
.090 E X C 100 E S S
SP1000V
.060 I N .030 C 0 H E S .030
G A 10 II N 1 .1 IN
SP1000V
.060 .090
1 IN
10 IN
100 IN
0 1 2 3 4 5 DISTANCE TO 90% WHITE TEST CARD--INCHES
DISTANCE
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 48
MAXI-AMP System Sensors for use with CM Series Modulated Amplifiers Sensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order. Sensor accessories are shown on page 24.
Excess Gain
Models/Dimensions FIBER OPTIC Mode glass fiber optics
LR400 & PT400 with FOF-400 fittings and fiber optics Range: see excess gain curves Temp. range: -40 to +100 degrees C The threaded barrel design of the LR400 and PT400 (see page 14) permit the connection of any Banner glass fiber optic assembly by using two model FOF-400 fittings. The sensors are typically mounted through 3/8 inch (10mm) diameter clearance holes, with the FOF-400 fittings threaded onto them after mounting. Setscrews in the fittings lock the fibers in place, but allow rapid replacement without disturbing any electrical wiring. As the excess gain curves show, the LR/PT400 combination produces a high-performance fiber optic sensing system. With the amplifier's 1 millisecond response time, this system can be used for almost any fiberoptic requirement.
FOF-400 Fiber optic Fitting
Fiber optic information: IT13S: individual assembly .06 in. (1,5mm) dia. bundle IT23S: individual assembly .12 in. (3mm) dia. bundle BT13S:bifurcated assembly .06 in. (1,5mm) dia. bundle BT23S:bifurcated assembly .12 in. (3mm) dia. bundle L9: .5 in. (12mm) dia. lens L16F: 1.0 in. (25mm) dia. lens
Beam Pattern
1000
LR/PT400 3 E X C 100 E S S
Opposed mode, no lenses with IT23S fibers with IT13S fibers
G A 10 II N
LR/PT400
2 I N 1 C 0 H E S 1
Opposed mode w/IT23S fibers w/IT13S fibers
2 3 0
1 .1 IN
1 IN
10 IN
100 IN
12 6 18 24 OPPOSED DISTANCE--INCHES
1000
LR/PT400 E X C 100 E S S with L9 lenses
Opposed mode with L16F lenses
IT23S fibers and L16F lenses IT23S fibers and L9 lenses
I N 8 C 0 H E S 8 16 24 0
1 .1 FT
1000
LR/PT400
24 16
G A 10 Opposed mode, II with IT23S N fibers
1 FT 10 FT DISTANCE
15
30
45
60
LR/PT400 with L16F lens and BRT-3 reflector
G A 10 II N
6 I N 3 C H 0 E S 3
1 FT
Retroreflective mode, with BRT-3 reflector and BT13S fiber w/L9 lens
6 with L9 lens and BRT-3 reflector
1 .1 FT
LR/PT400
9 w/L16F lens
9 10 FT
100 FT
0
DISTANCE
10 5 15 20 DISTANCE TO REFLECTOR--FEET
25
1000
E X C 100 E S S G A 10 II N
Diffuse mode -- range based on 90% reflectance white test card
0.6
LR/PT400
0.4 I N 0.2 C 0 H E S 0.2 with BT23S fibers
0.4 with BP13S fibers
1 .1 IN
LR/PT400
Diffuse mode w/BT23S fibers w/BT13S fibers
0.6
1 IN
10 IN
100 IN
2 0 1 3 4 5 DISTANCE TO 90% WHITE TEST CARD--INCHES
DISTANCE
Hookup to CM Series MAXI-AMP Modules Hookup of LR/PT200, 250, 300, and 400
NOTE: up to three sensors may be connected to each amplifier (see specifications).
16
75
OPPOSED DISTANCE--FEET
100 FT
Retroreflective mode, with BT13S fibers
E X C 100 E S S
For complete information on glass fiber optic assemblies and accessories, see Banner product catalog.
The hookup diagrams on this page and the next include all of the remote sensors for use with CM Series modulated amplifier modules. It is important to note how the shield wire of a remote sensor is wired. The shield wire is the uninsulated wire in each sensor cable. Failure to connect the shield as shown may result in false operation of the amplifier. When wiring emitters, it is good practice to connect the positive (white) wire first. LEDs are sensitive to application of the wrong voltage, and can easily be destroyed.
30
DISTANCE
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 49
Sensor Hookup Diagrams for CM Series MAXI-AMP Modules Hookup of LR300 and PT300
Hookup of SP320D
Hookup of SP300D, SP300L, LP400WB, and SP1000V
NOTE REGARDING CABLE SPLICING: When splicing additional cable length to modulated remote sensors, it is important to use a separate shielded cable for emitter and receiver wires. Combining emitter and receiver wires together in the same cable (even if the cable is shielded) will result in direct coupling of the emitter signal to the receiver leads. This is called "cable crosstalk", and will not allow full amplifier sensitivity setting without an amplifier "lock on" situation, which appears as a continuous LIGHT condition. Banner offers extension cable for remote sensors which, if used for cable splicing, will minimize the chances for cable crosstalk (see page 24).
Logic Level NPN Output (CM3 models) The AUXILIARY terminal (#9) of CM3 models offers a logic-level NPN (current sinking) output which may be used as a fast-response solid-state inhibit signal to the AUXILIARY input of MAXI-AMP CM5 modules. This output may also serve as an input to any B Series, Plug Logic, or CL Series module. In addition, this output may interface to other dc devices or circuits like counters, rate meters, or programmable logic controllers. Switching capacity is 20mA at 12V dc. The example here shows the use of LR & PT400 sensors and a CM3 module to provide inspection information, with the SP300D functioning as a product sensor. Typically, the CM5 module would be programmed for the ONE-SHOT or DELAYED ONE-SHOT logic function. If the LR & PT400 "sees" an acceptable condition when the SP300D senses the leading (or trailing) edge of a product, the CM3 will inhibit a reject pulse from occuring.
CM5 Model
CM3 Model
Power for External Devices External 10 to 30V dc devices such as self-contained sensors may be connected between terminals #3 (+) and #1 (-) of any CM series MAXI-AMP module. Terminal #3 offers 40mA maximum. This is sufficient to power most Banner selfcontained dc sensors.
CM5 Model
As the example at the right illustrates, the current sinking output of a self-contained sensor powered by the MAXIAMP may be used as the input to the AUXILIARY terminal of a CM5 module.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
17
Page 50
MAXI-AMP™ CL Series Logic-level Input Modules
Banner CL Series MAXI-AMP™ modules are the perfect solution for many sensing/control applications where economy, versatility, dependability, and ruggedness are important. CL Series MAXI-AMPs combine power supply, timing logic (in CL5 models) and output relay in a single compact, cost-saving module. The integrated, stand-alone design saves both the expense of a separate control chassis and a substantial amount of panel space. Several models are available, for either 120V ac or 240V ac operation, and either with or without timing logic (models are listed in table at above right). Alternatively, any model may be powered by 12 to 28V dc. The well-defined electrical characteristics of CL Series MAXI-AMP modules provide a wealth of application possibilities. The input circuit accepts signals from any Banner dc sensor with an NPN (current sinking) output; as well as from MAXI-AMP, MICRO-AMP, and Plug Logic modules. The input is compatible with almost any sensor or circuit which has an NPN transistor (current sinking) output. Additionally, inputs may be generated by limit switches, contact closures, and optical couplers. A 50mA power supply is included for powering 10 to 30V dc devices. CL5 models offer a versatile multi-function timing logic circuit which is programmable for twelve of the most popular and useful delay, oneshot, and latch functions (see page 6). The MAXI-AMP offers the choice of either single or dual timing functions in the same module. Logic and timing may be easily reprogrammed as control requirements change.
Recognized
MODEL
SUPPLY VOLTAGE
CL3RA
105 to 130V ac, or 12 to 28V dc
CL3RB
210 to 250V ac, or 12 to 28V dc
CL5RA
105 to 130V ac, or 12 to 28V dc
CL5RB
210 to 250V ac, or 12 to 28V dc
The other solid-state contact will switch dc loads of up to 30V dc and up to 50 milliamps. Both solid-state outputs are electrically isolated from the MAXI-AMP power supply. Both outputs switch within the 1 millisecond response time of the CL module circuitry. NOTE: ac loads may take up to 1/2 cycle (8.3 milliseconds) to turn "off".
OUTPUT
LOGIC
SPDT electromechanical relay, plus NPN transistor solidstate switch
ON/OFF
SPDT electromechanical relay (5 amp contact rating)
12 timing functions
In order to allow accurate timing adjustments, each CL5 model has three time ranges to choose from. Timing adjustments are made via rugged 15-turn potentiometers. Circuitry is included to prevent any possibility of false output on power-up. An auxiliary input is available on CL5 models for interrogation or reset of the selected logic function by using an additional sensor or input signal (see example, page 20). Page 6 describes the function of the auxiliary input for each logic mode. The output circuit for all CL Series modules is an SPDT 5-amp electromechanical relay. A solid-state relay is offered as an option to the electromechanical relay (see information below). Additionally, CL3 models have an NPN transistor solid-state switch. This solid-state output may be used to take advantage of the amplifier's fast 1-millisecond response. This output may be connected directly to the primary or auxiliary input of other Banner logic modules, including CL5 modules, MICRO-AMP logic modules, and Plug Logic modules. In addition, this output can interface to other dc devices or circuits such as counters, rate meters, or programmable controllers. Switching capacity is 20mA at 12V dc. The output may be programmed for either normally open or normally closed operation. Like all MAXI-AMPs, the CL Series modules are designed both electrically and mechanically for solid dependability in industrial environments.
Solid-state Output Option CL Series modules are available with a solid-state relay which replaces the electromechanical relay. This is actually two SPST solid-state contacts. One contact will switch ac loads, and is rated at 250V ac maximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 amp at 50 degrees C). A solid-state contact is particularly helpful when switching inductive ac loads which can cause electrical "noise" and contact damage when switched with a "hard" relay contact.
Certified
MODEL
SUPPLY VOLTAGE
CL3A
105 to 130V ac, or 12 to 28V dc
CL3B
210 to 250V ac, or 12 to 28V dc
CL5A
105 to 130V ac, or 12 to 28V dc
CL5B
210 to 250V ac, or 12 to 28V dc
OUTPUT SPST solid-state contact for switching AC loads up to 250V ac and up to 3/4 amp, plus solidstate contact for switching dc loads up to 30V dc and up to 50mA.
LOGIC ON/OFF
12 timing functions
Both outputs are normally open, but may be programmed for normally closed operation. Except for the output configuration, the specifications for the models listed in the table at the right are exactly the same as for the standard CL Series models.
18
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 51
MAXI-AMP CL Series Specifications SUPPLY VOLTAGE: Models CL3RA, CL5RA: 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 60mA. Models CL3RB, CL5RB: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc at 60mA. *Do not connect ac voltage if using external dc power. OUTPUT CONFIGURATION: all models have SPDT electromechanical relay: CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load), 1/10 H.P. at 240V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. CLOSURE TIME: 10 milliseconds max. RELEASE TIME: 10 milliseconds max. MAXIMUM SWITCHING SPEED: 20 operations/second MECHANICAL LIFE: 20,000,000 operations CL3 models also have a logic level current sinking NPN transistor switch at pin #9. See schematic below and hookup info.
INDICATOR LEDs: Red indicator LEDs for input and output status.
CONSTRUCTION: Rugged NORYL® polyphenylene oxide (PPO® ) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base. OPERATING TEMPERATURE: 0 to 50 degrees C (32 to 122 degrees F).
Generalized Hookup models with electromechanical relay output
AMPLIFIER: RESPONSE SPEED: 1 millisecond INPUT CHARACTERISTICS: input is switched when the voltage at pin #2 is pulled below 1V dc or when less than 1K ohms is connected between pins #2 and #1. When an inverting jumper is connected between pins #10 and #11, input is switched when the voltage at pin #2 rises above 4.5V dc or when the impedance between pins #2 and #1 exceeds 15K ohms. HYSTERESIS: greater than .35 volts, less than 2 volts.
Dimension Drawing
MULTIPLE SENSOR HOOKUP: any number of switched output devices may be connected in parallel to the input (see hookup example).
TIMERS (CL5 models only): TIME RANGES:
LOW range - 10 to 150 milliseconds MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds REPEATABILITY: +/-2% of set time over all extremes of supply voltage and temperature
ADJUSTMENTS: Miniature switches for setting of timing function, timing range, and output polarity (CL5 models). 15-turn clutched potentiometer for time setting (CL5 models).
CL5 Models
Functional Schematics
NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device (see hookup example). Current available is 50mA at 120V ac (240V ac) line level; 40mA at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power.
CL3 Models
NOTE #2: pulling pin #9 low (to Common) will inhibit the timing, or reset the latch of CL5 models. (See "Description of Logic Functions", page 6) NOTE #3: pin #9 of model CL3RA and CL3RB may be connected directly to the primary or auxiliary input of MAXI-AMP model CL5 or to Banner Plug Logic modules.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 52
Sensor Hookup Diagrams for CL Series MAXI-AMP Modules To MAXI-BEAM Sensors
To MULTI-BEAM Sensors
NOTE: use power block model RPBT.
NOTE: use power block model PBT or PBT2. MULTI-BEAM
CL3 or CL5 model
7 8
7 8
4 3 2 1
6
6
9 10 11 1 2 3
4 5
4 5
CL3 or CL5 model
RPBT
PBT
9 10 11 1 2 3
MAXI-BEAM
3
4
1
2
NOTE: the MAXI-AMP cannot power a MULTI-BEAM emitter and receiver pair. Use a separate power source for the emitter (e.g.- power block PBA-1, etc.)
To VALU-BEAM SM912 Series Sensors
To MINI-BEAM SM312 Series Sensors
SM912
7 8
4 5
6
SM312 BLUE
7 8
BLUE
This hookup is for DC NPN (current sinking) models of S18 Series, Q25 Series, and other DC sensors bearing the EZ-BEAM logo.
SE612
4 5
7 8
7 8
6
CL3 or CL5 model
6
4 5
9 10 11 1 2 3
NOTE: Black wire is not used
BROWN WHITE
To EZ-BEAM Sensors
To ECONO-BEAM SE612 Series Sensors
CL3 or CL5 model
CL3 or CL5 model
6
NOTE: Black wire is not used
9 10 11 1 2 3
NOTE: Black wire is not used
WHITE
BROWN WHITE
BROWN
9 10 11 1 2 3
4 5
CL3 or CL5 model
9 10 11 1 2 3
BROWN
BLACK
BLUE
BLUE
NOTE: White wire is not used
Use of Auxiliary Input (CL5 models)
20
SE61E
Brown
CL3 or CL5 model
9 10 11 1 2 3
7 8
NOTE: the MAXI-AMP can supply 50mA for external 10 to 30V dc devices. Carefully check the current draw of the devices to be powered by the MAXI-AMP.
+V dc @50ma
NOTE: Black wire is not used
6
This example shows a typical inspection/rejection scheme which uses a Banner MINI-BEAM as the inspection sensor. Typically, the CL5 module would be programmed for the ONE-SHOT or DELAYED ONE-SHOT logic function. If the SM312 "sees" an acceptable condition when the SE612 senses the leading (or trailing) edge of the product, the SM312 will inhibit a reject pulse from occuring. Reject products will be ejected by the output pulse.
GATE (Interrogate)
SE61R
4 5
CL5 model MAXI-AMPs have an auxiliary input at terminal #9 which may be used for the interrogation or reset of the selected logic function. This is accomplished by a switch closure between pins #9 and #1 (Common). The auxiliary input may also be switched by a DC device with an NPN transistor (current sinking) output. The effect of the auxiliary input is described for each logic function on page 6.
White Blue
+15V dc (#3)
Brown
Blue (#1)
White
Inhibit SM312
+V dc (#3)
Brown
NOTE: Black wire is not used
DATA (Inspection)
Blue (#1)
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 53
Hookup of Multiple Self-contained Sensors OUTPUT OCCURS
SENSOR PROGRAM: Light or Dark Operate
INVERTING JUMPER Installed Between Module Terminals #10 and #11
LIGHT OPERATE
NO
If any receiver "sees" light
LIGHT "OR"
LIGHT OPERATE
YES
When all receivers "see" dark
DARK "AND"
DARK OPERATE
NO
If any receiver "sees" dark
DARK "OR"
DARK OPERATE
YES
When all receivers "see" light
LIGHT "AND"
MINI-BEAM SM312 Series and VALU-BEAM SM912 Series sensors have a switch on the back of their housings which is used to program the sensors for LIGHT or DARK operate. MAXI-BEAM sensors are set for LIGHT or DARK operate using the programming ring. MULTI-BEAM sensors are programmed for LIGHT or DARK operate with the logic module jumper wire. OMNI-BEAMs are programmed by a switch in the sensor block.
(AFTER DELAY, IF ANY)
Brown +V dc
6
2 3
CL3 or CL5 model
Brown White
7 8
Blue SM31R/RL (#1)
9 10 11 1
4 5
For ON/OFF sensor operation, light operate is equated to normally open output, and dark operate is defined as normally closed. EZ-BEAM sensors have both a normally open and a normally closed output. Selection of either output determines the LIGHT/DARK operate mode. ECONO-BEAM sensors are not programmable and must be ordered for LIGHT OPERATE (standard models) or DARK OPERATE (model suffix "NC").
Brown +V dc
2 3
4 5 6 7 8
CP12 power supply
White Blue
SWITCH SWITCH
(NOTE: see page 6 for description of logic functions)
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
OFF
OFF
1.5 Sec. Max. Time
ON
OFF
15 Sec. Max. Time
OFF
ON
On/Off
ON
ON
ON
OFF
ON
OFF
ON
On Delay
ON
ON
OFF
OFF
ON
OFF
ON
3
Off Delay
ON
OFF
ON
OFF
ON
OFF
ON
On and Off Delay
ON
OFF
OFF
OFF
ON
OFF
ON
One-shot
OFF
OFF
ON
OFF
ON
OFF
ON
Delayed One-shot
OFF
OFF
OFF
OFF
ON
OFF
OFF
Limit
ON
ON
OFF
OFF
OFF
OFF
ON
Repeat Cycle
ON
OFF
OFF
ON
ON
OFF
ON
AC Latch
OFF
ON
ON
OFF
ON
ON
ON
DC Latch
ON
ON
ON
OFF
ON
ON
ON
Delay and Latch
ON
ON
OFF
OFF
ON
ON
ON
Limit and Latch
ON
ON
OFF
OFF
OFF
ON
ON
5 6 7
SM31E/EL Blue (#1)
SM31R/RL
2
4
Blue (#1) Brown +V dc
Settings illustrated below are factory settings. Factory settings are "underlined" in the table.
TIMING LOGIC PROGRAMMING
SM31E/EL
Brown +V dc
Timing Logic Programming (CL5 models)
1
Blue (#1)
Brown +V dc
Blue SM31R/RL (#1)
The addition of a jumper wire between MAXI-AMP terminals #10 and #11 changes the input response from a low-going to a high-going signal. This feature, combined with the selection of LIGHT or DARK operate at the sensor, allows "AND" logic with parallel sensor connections.
O F F
SM31E/EL
White
105-130V 105-130Vac AC
ON
LOGIC DESCRIPTION
+V dc
9 10 11 1
Any number of self-contained dc sensors may be wired together in parallel to a single CL Series MAXI-AMP module to create almost any multiple-sensor logic configuration. Power for the sensors may be obtained from MAXI-AMP 400mA power supply CP12 (shown below) or from 1-amp model PS120-15. The table at the right describes how the four most frequently used multiple-sensor logic configurations may be created.
8 9 10
A group of ten switches located on one side of the module is used to select the timing logic for CL5 models. Switches #1 through #7 are used to select the logic function. Switch #8 programs the output for either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10 program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds, and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timing mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However, DELAY and HOLD times are independently adjustable within the selected range.
N/C Output
OFF
N/O Output
ON
.15 Sec. Max. Time
The diagram shows switch locations, and the table summarizes the program switch positions.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com