Page 36
MAXI-AMP™ CD Series Modules Specifications SUPPLY VOLTAGE: Models CD3(R)A, CD5(R)A: 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA. Models CD3(R)B, CD5(R)B: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA. *NOTE: do not connect ac power when using external dc power.
Functional Schematics Models CD5RA, CD5RB
OUTPUT CONFIGURATION: CD3A, CD3B, CD5A, CD5B: Two solid-state SPST switches, one for ac loads of up to 250V ac and up to 3/4 amp, the other for dc loads of up to 30V dc and up to 50mA. CD3A and CD3B also have a logic level current sinking NPN transistor switch at pin #9, maximum load 20mA at 12V dc max. CD3RA and CD3RB: SPDT electromechanical relay (see specifications, below) plus an NPN transistor solid-state logic-level dc switch (at pin #9, maximum load 20mA at 12V dc max.). CD5RA and CD5RB: SPDT electromechanical relay (specs below). SPDT Electromechanical Relay Specifications: CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load), 1/10 H.P. at 240V ac. Install a transient suppressor (MOV) across contacts that switch inductive loads. CLOSURE TIME: 10 milliseconds max. RELEASE TIME: 10 milliseconds max. MAXIMUM SWITCHING SPEED: 20 operations/second MECHANICAL LIFE: 20,000,000 operations AMPLIFIER: RESPONSE SPEED: Programmable for 1.5 or 15 milliseconds. NOTE: use 15 millisecond setting for maximum sensor excess gain. MODULATION FREQUENCY: selectable, "A" or "B". SENSOR LEAD LENGTH: 100 feet (30 m) maximum, each sensor. When splicing, use separate cable for emitter and receiver, or order sensors with extended cable length.
NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device (see hookup example, page 9). Current available is 40 mA at 120V ac (240V ac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage when using external dc power. NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latch of CD5 models (see "Description of Logic Functions", page 6).
Models CD3RA, CD3RB
SENSOR HOOKUP: One SP12 Series opposed mode sensor pair per amplifier module. Additionally, one self-contained sensor may be connected at pin #9 (CD5 models) to provide a RESET or INHIBIT signal. +15V dc power for this one additional sensor is available at module pin #3 (40mA maximum load). TIMERS (CD5 models only): Timing ranges: LOW range - 10 to 150 milliseconds MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds Repeatability: +/-2% of set time over all extremes of supply voltage and temperature ADJUSTMENTS: Miniature switches are provided for programming of LIGHT/DARK operate, amplifier response time, modulation frequency, normally open or normally closed output and timing function (CD5 models). 15-turn clutched potentiometer for gain (sensitivity) and time settings (CD5 models). OPERATING TEMPERATURE: 0 to 50°C (+32 to 122°F). INDICATOR LEDs: Two LEDs. A red indicator LED is "ON" when the module output is energized. Exclusive Banner Alignment Indicating Device (AID™) system lights another red LED indicator whenever the receiver "sees" its own modulated light source, and pulses it at a rate proportional to the strength of the received light signal.
NOTE #3: pin #9 of CD3 models may be connected directly as the input to Banner CL Series MAXI-AMPs or to Banner MICRO-AMP™ or Plug Logic modules (see hookup example, page 9).
Dimension Drawing
CONSTRUCTION: Rugged Noryl® polyphenylene oxide (PPO®) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base. Noryl® is a registered trademark of General Electric Co.
Generalized Hookup:
7 8
4
5 6
AC Supply
4
SPDT 5A Relay Output
CD3RA CD3RB CD5RA CD5RB
9 10 11 1 2 3 models with electromechanical relay output LED + LED Common PT PT + Auxiliary (see table)
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 37
Amplifier Programming (all CD Series modules) Amplifier response conditions may be programmed via the group of four switches located on one of the narrow sides of the MAXI-AMP™ module.
Switch #1 selects the modulation frequency of the amplifier and the emitter light source. When two pairs of SP12 Series sensors are being used in close proximity to each other, the modulation frequency switch of their respective CD Series modules should be set to different modulaON tion frequencies. This makes it possible to use the two sensor pairs in close proximity without optical crosstalk. Both amplifiers must be set for the same response time (either 1.5 or 15 milliseconds) to ensure freedom from crosstalk.
Switches #2 and #3 are used to program the amplifier response time. The 15 millisecond setting allows SP12 Series sensors to operate at their maximum excess gain.
Switch #4 is used to select LIGHT OPERATE or DARK OPER-
O F F
1 2 3 4
AMPLIFIER PROGRAMMING
Factory settings are shown at left. The "underlined" settings in table below are factory settings. SWITCH
SWITCH
SWITCH
SWITCH
#1
#2
#3
#4
Modulation freq. "A"
OFF
Modulation freq. "B"
ON
1.5 millisecond response
OFF
OFF
15 millisecond response
ON
ON
ATE. In the LIGHT OPERATE mode, the output will energize (in ON/OFF or LATCH operation) or the timing function will initiate (in DELAY, ONE-SHOT, or LIMIT operation) when the receiver "sees" sufficient light (excess gain greater than 1X). In DARK OPERATE, the output will energize or timing will begin when the receiver is sufficiently dark (excess gain less than 1X).
The diagram at the left shows the location of switches 1-4, and the table summarizes the settings required for each response condition.
Light operate
ON
Dark operate
OFF
NOTE: An adhesive-backed mylar label is supplied. It may be marked to indicate switch programming and then applied to the MAXI-AMP housing as a switch cover.
Timing Logic Programming (CD5 models) Settings illustrated below are factory settings. Factory settings are "underlined" in the table. TIMING LOGIC PROGRAMMING
ON O F
1
F
2 3 4 5
SWITCH SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
On/Off
ON
ON
ON
OFF
ON
OFF
ON
On Delay
ON
ON
OFF
OFF
ON
OFF
ON
Off Delay
ON
OFF
ON
OFF
ON
OFF
ON
On and Off Delay
ON
OFF
OFF
OFF
ON
OFF
ON
One-shot
OFF
OFF
ON
OFF
ON
OFF
ON
Delayed One-shot
OFF
OFF
OFF
OFF
ON
OFF
OFF
Limit
ON
ON
OFF
OFF
OFF
OFF
ON
Repeat Cycle
ON
OFF
OFF
ON
ON
OFF
ON
AC Latch
OFF
ON
ON
OFF
ON
ON
ON
DC Latch
ON
ON
ON
OFF
ON
ON
ON
Delay and Latch
ON
ON
OFF
OFF
ON
ON
ON
Limit and Latch
ON
ON
OFF
OFF
OFF
ON
ON
.15 Sec. Max. Time
OFF
OFF
1.5 Sec. Max. Time
ON
OFF
15 Sec. Max. Time
OFF
ON
6 7 8 9 10
A group of ten switches, located on the side of the module opposite the amplifier program switches, is used to select the timing logic for the CD5 models. Switches #1 through #7 are used to select the logic function. Switch #8 programs the output for either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10 program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds, and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timing mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However, DELAY and HOLD times are independently adjustable within the selected range.
N/C Output
OFF
N/O Output
ON
The diagram shows switch locations, and the table summarizes the program switch positions.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
5
Page 38
Description of Logic Functions for CD5, CL5, CM5, and CR5 models ON/OFF: ON/OFF operation does not involve timing. The output simply follows the action of the input signal. Grounding pin #9 (AUXILIARY) turns the output "off", regardless of the state of the input signal. This may be accomplished by closing a switch or relay contact between pins #9 and #1 (common), or by connecting an open collector NPN (current sinking) output of any external dc device directly to pin #9. NOTE: connect the COMMON of any external dc device to pin #1 of the MAXI-AMP to establish a voltage reference between the dc supply for the external device and the internal dc supply of the MAXI-AMP.
ON DELAY: The ON DELAY timer keeps the output "off" until the selected LIGHT or DARK signal has been present for the preset "DELAY" time. If the input signal is interrupted, the timing is reset and starts over with the next signal. Grounding pin #9 immediately cancels an output in progress and resets the delay timer. The delay timer is restarted when the inhibit signal is removed, if an input signal is present.
OFF DELAY: The output energizes immediately when the input signal occurs, but does not de-energize until the signal has been removed for the preset OFF-DELAY ("HOLD") time. Grounding pin #9 prevents an output from occuring. If an inhibit input occurs during an output, the output remains "on" for the remainder of the OFF-DELAY time.
ON & OFF DELAY: ON and OFF DELAY logic combines both timing functions into a single mode. The ONDELAY ("DELAY") time and the OFF-DELAY ("HOLD") time are independently adjustable within the selected time range. Momentary grounding of pin #9 during the ON-DELAY period resets the DELAY timer. An inhibit signal which occurs during an output will allow the output to stay energized for the remainder of the OFF-DELAY time. ON and OFF DELAY logic is often used in jam and void control, high/low level control, and edge-guiding applications.
ONE-SHOT: The output of a ONE-SHOT function is a pulse of adjustable "HOLD" duration which is independent of the duration of the input signal. With the MAXI-AMP programmed for LIGHT operate, the pulse occurs when the input signal changes from dark to light. In DARK operate, the pulse occurs with a light to dark input transition. Grounding pin #9 prevents the one-shot from triggering, but does not affect a pulse already under way.
DELAYED ONE-SHOT: A DELAYED ONE-SHOT is initiated by either a momentary or maintained input signal. This input starts the adjustable "DELAY" period, after which the output pulses for an adjustable pulse ("HOLD") time. No further action occurs unless the input is removed and reapplied, beginning a new sequence. Grounding pin #9 during the delay period will cancel the sequence, and no output occurs. This feature is often used for inspection/rejection control logic. An inhibit signal will not affect a pulse under way.
LIMIT: The output of the LIMIT function follows the action of the input, as it does with the ON/OFF function. However, an input signal which is longer than the adjustable LIMIT ("HOLD") time will turn the output "off". Removing the input signal resets the timer. This function is sometimes called "TIME LIMITED ON/OFF", and is useful for energy conservation. Grounding pin #9 cancels the output. Lifting the inhibit restarts the LIMIT timer, if an input signal is present.
REPEAT CYCLE: The REPEAT CYCLE function provides an oscillating output when an input signal is present. Presence of an input signal triggers an adjustable "DELAY" timer. After the delay, the output energizes for an adjustable "HOLD" period. If the input remains, the output continues to cycle "on" and "off" at this rate indefinitely. When the signal is removed, any output in progress completes and then remains "off" until the next signal and DELAY period. Grounding pin #9 cancels the sequence, but will allow the completion of a "HOLD" period in progress. Lifting the inhibit signal begins the DELAY period, if an input signal is present.
AC LATCH: An AC LATCH is the combination of a ONE-SHOT and a LATCH. A momentary or sustained input will latch the output "on". Grounding pin #9 will reset the latch, even if the input signal remains. The output will not re-latch until the input signal is removed and then reapplied.
DC LATCH: The output will latch "on" whenever the selected LIGHT or DARK input condition occurs. Grounding pin #9 of a dc latch will turn the output "off" regardless of the state of the input signal. If the signal is present when the reset is removed, the output will immediately latch "on" again.
DELAY AND LATCH: The DELAY + LATCH is a combination of the ON-DELAY and DC LATCH functions. An input must be present for at least the adjustable "DELAY" time for the output to latch "on". If the input signal is removed during the timing cycle, the timing is reset. Momentary grounding of pin #9 resets the latch and/or the DELAY timing cycle. Sustained grounding of pin #9 inhibits any output.
LIMIT AND LATCH: The LIMIT + LATCH operates exactly like the LIMIT function, except that the LIMIT ("HOLD") timer can be reset only by the auxiliary input. An output remains latched "off" until reset by momentarily grounding pin #9. In addition to resetting the timer, grounding pin #9 will hold the output "off", regardless of the state of the input signal. 6
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 39
MAXI-AMP™ System SP12 Series Opposed Mode Remote Modulated Barrel Sensors for use with MAXI-AMP CD Series Modules opposed mode • Leakproof NEMA 6P threaded-barrel ® remote sensor pairs; VALOX or stainless steel housing
• Compact and powerful: 1/2" (12mm) in diameter by 2"
SP12 Series sensors (foreground) shown with MAXI-AMP™ CD Series amplifier and logic modules (see pages 3-6).
long; 200-foot sensing range. Apertures are available.
• Special preamplified circuit design for noise immunity equal to that of self-contained sensors
Banner SP12 Series sensors are a family of powerful, modulated, totally-encapsulated opposed mode remote sensor pairs in compact, threaded-barrel type housings. They are the ideal choice for applications that require high excess gain together with small size in difficult sensing environments. SP12 Series sensors are especially effective at penetrating heavy contaminants when used at close range. The preamplified design of these sensors results in exceptional noise immunity. Signals carried along remote receiver cables are often subject to interference (from electrical noise sources) that can be as strong as (or stronger than) the desired light signal. The severity of this problem often worsens with increasing sensor cable length. SP12 Series receivers contain a preamplifier that immediately boosts the received light signal to a high level before sending it down the cable to the rest of the sensing system. SP12 Series sensors are designed for use with the Banner CD Series MAXI-AMP™ modules. CD Series modules provide sensor power, additional amplification, a choice of several programmable timing logic functions (CD5 models), and output circuitry for interfacing to a load. They also allow two different programmable sensor modulation frequencies, making it possible to use multiple high-powered sensor pairs in close proximity to each other without optical crosstalk. CD Series modules are available for a wide range of supply voltages. Each CD module powers one SP12 emitter/receiver pair. See page 3 for more information. SP12 sensors are rated NEMA 6P (IEC IP67) for use in wet locations. There is a choice of either VALOX® or stainless steel housing style (see table, below). Positive sealing at both ends of the sensors, with no exposed epoxy interfaces, eliminates all leak paths (including capillary leakage). Electronics are fully encapsulated for maximum resistance to mechanical shock and vibration. Lenses are acrylic, and quad-ring sealed. These sensors may be used with watertight, thread-on apertures to create very narrow, very powerful effective beams (see next page). A 1/2" clearance hole is required for mounting. Alternatively, the Banner model SMB12MM mounting bracket may be used (see next page). SP12 Series sensors are supplied with 6-1/2 feet of PVCcovered attached cable, or QD connectors (page 8). Options for models with attached cable are summarized below. The maximum recommended emitter or receiver cable length is 100 feet (each).
SP12 Series Barrel Sensors Model
Type
Housing Material
SP12SEL
Emitter
Stainless steel
SP12PEL
Emitter
VALOX®
SP12SRL
Receiver
Stainless steel
SP12PRL
Receiver
VALOX®
Models are also available with QD connectors (page 8).
Excess Gain Curve
Beam Pattern
1000
SP12 Series opposed mode emitters and receivers
E X C 100 E S S G A II N
15ms response
60 40 I N 20 C 0 H E 20 S
10
1.5ms response
40 1.5ms response
0 1 FT
SP12 Series emitters and receivers
60
15ms response
0 10 FT
100 FT
1000FT
40
80
120
160
200
OPPOSED DISTANCE--FEET
DISTANCE
Specifications, SP12 Sensors SUPPLY VOLTAGE: sensors are powered from a Banner CD Series
MAXI-AMP™ module (see page 3). RANGE: up to 200 feet in opposed mode (see gain curve, above). RESPONSE SPEED: selectable for 1.5 or 15 milliseconds; a function of the MAXI-AMP CD Series module. LIGHT BEAM: infrared LED, 880nm. Effective beam diameter: 3/8". CONSTRUCTION: NEMA 6P.
12mm diameter tubular threaded VALOX® or stainless steel housing; positive sealing at both ends, quad-ring sealed acrylic lens. Electronics fully epoxy-encapsulated. Two jam nuts are provided: VALOX® for VALOX® units; stainless steel for stainless steel units. Mounting requires 1/2" diameter clearance hole. OPERATING TEMPERATURE: -40 to +70°C (-40 to +158°F). CABLE: sensors are supplied with 6-1/2 feet of PVC-covered 2- or 3conductor cable. Models with QD connectors are available (page 8). VALOX® is a registered trademark of General Electric Co.
Dimension Drawing
NOTE: Models with 30-foot attached cable are available (contact factory for information). 2- and 3-conductor 50- and 100-foot extension cables (without connectors) are also available. For 2-conductor (emitter) cable: order model EC12E-50 (50') or model EC12E-100 (100'). For 3-conductor (receiver) cable: order model EC12R-50 (50') or model EC12R-100 (100').
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
7
Page 40
SP12 Series Opposed Mode Remote Modulated Barrel Sensors with Quick Disconnect (QD) Cable Option The stainless steel models of SP12 Series modulated remote barrel sensors may be ordered with a built-in connector designed to mate with eurofast™ quick-disconnect (QD) cables. The resultant sensor model numbers are:
SP12SELQD (emitter), and SP12SRLQD (receiver). The mating cables are ordered separately. Cables are available in 15 foot lengths with either of two styles of mating connector. Cable model MQDC415 has a straight connector, and model MQDC-415RA has a right-angled connector (see drawings below). In both models, the plug body is molded to the PVC cable for waterproof integrity. Plug contacts are gold-plated.
Dimensional Information for MQDC-415 Cable
Dimensional Information for MQDC-415RA Cable White wire Blue wire
White wire Black wire
Blue wire
Brown wire
Black wire Brown wire
Dimension Drawing
Model SMB12MM Mounting Bracket Model SMB12MM is a stainless steel mounting bracket for SP12 Series sensors. The sensor mounts to the bracket using the two jam nuts supplied with the sensor. This rugged, slotted bracket allows ±10 degrees of lateral movement. Bracket is 12-gauge stainless steel. The bracket mounting holes accommodate #8 hardware.
SMB12MM bracket:
Apertures Rectangular and circular thread-on watertight apertures are available for SP12 sensors. Apertures are used to shape and size the sensor's effective beam and to protect the sensor's lens. Use of apertures with these high-gain sensors makes it possible to create very narrow, concentrated sensing beams for demanding applications. Aperture Kit AP12SC includes three round apertures with openings of .02", .04". and .10" diameter. Aperture kit AP12SR has three rectangular apertures .02", .04", and .10" wide. Both include lens, o-rings, and thread-on housing.
8
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 41
SP12 Sensor Hookup to CD Series MAXI-AMP™ Modules 1) Hookup of SP12 Series Sensors (all models) SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here (QD sensor models shown). Each MAXI-AMP™ CD Series module supports use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below, this page).
7 8
AC SUPPLY*
5 6
AC Load Load Common
4
DC Load
CD3A CD3B CD5A CD5B
9 10 11 1 2 3
Models with isolated solid-state contacts LED + (white)
Emitter
Receiver
Emitter
Receiver
LED - (green) COMMON (black) PT - (blue) PT + (brown) AUX
5 6 7 8
AC SUPPLY*
4
SPDT 5A Relay Output
CD3RA CD3RB CD5RA CD5RB
9 10 11 1 2 3
Models with electromechanical relay contacts LED + (white) LED - (green) COMMON (black) PT - (blue) PT + (brown) AUX
*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply, connect +12 to 28V dc at ≥70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.
2) Logic Level NPN Output (CD3 models)
9 10 11 1 2
CD3 models
7 8
AC Supply
SP300D
Gate (Interrogate)
Data (Inspection) SP12 Series Receiver
SP12 Series Emitter white green black blue brown
3
4 5 6
The example here shows the use of SP12 Series sensors and a CD3 module to provide inspection information, with the SP300D functioning as a product (GATE) sensor.
Typically, the CM5 module would be programmed for the ONE-SHOT or DELAYED ONE-SHOT logic function. If the SP12 pair "sees" an acceptable condition when the SP300D senses the leading (or trailing) edge of a product, the CD3 will inhibit a reject pulse from occuring.
9 10 11 1 2 3
4 5 6 7 8
The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA and CD3RB modules offers a logic-level NPN (current sinking) output which may be used as a fast-response solid-state inhibit signal to the AUXILIARY input of MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output may also serve as an input to any MICRO-AMP™, Plug Logic, or CL white green Series logic module. In addition, CM5 this output may interface to other dc black models AC devices or circuits like counters, red Supply rate meters, or programmable logic controllers. Switching capacity is Inhibit 20mA maximum at 12V dc max.
See Hookup Diagram #1 (above) for load and power connection information.
3) Power for External Devices (all models) 9 10 11 1 2 3
AC Supply
7 8
As the example at the right illustrates, the current sinking output of a selfcontained sensor powered by the MAXIAMP may be used as the input to the AUXILIARY terminal of a CD5 module.
GATE (Interrogate)
+15V dc @40mA
4 5 6
External 10 to 30V dc devices such as self-contained sensors may be connected between terminals #3 (+) and #1 (-) of any CD series MAXI-AMP module. Terminal #3 offers 40mA maximum. This is sufficient to power most Banner self-contained dc sensors.
CD5 models
Inhibit
NOTE: Black wire from SE612 is not used
SP12 Series Emitter white green black blue brown
SP12 Series Receiver
DATA (Inspection)
SE612
White +15V dc (#3)
Brown
Blue (#1)
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 42
MAXI-AMP™ CM Series Modulated Amplifier Modules
CM Series MAXI-AMPs combine power supply, modulated photoelectric amplifier, timing logic (in CM5 models) and output relay in a single compact, cost-saving module. CM-series modules work together with the popular family of Banner high-performance modulated remote sensors (pages 13-17). These sensors offer small size and excellent optical performance, and are built to operate in highly demanding sensing environments. MAXI-AMP modules themselves are also ruggedly built for dependable industrial duty. CM Series MAXI-AMP modules contain the state-of-the-art Banner custom-designed CMOS modulator/demodulator/amplifier circuit, offering high immunity to both ambient light and electrical interference plus reliable sensor performance. All models have Banner's exclusive, patented Alignment Indicating Device ("AID™") system, which lights an LED indicator whenever the sensor sees a "light" condition, and pulses the LED at a rate proportional to the received light signal strength. All CM Series modules are programmable for LIGHT or DARK operate and either high or low hysteresis. Input response time may be set at 0.3, 2, or 10 milliseconds. The 10-millisecond response mode offers enhanced immunity to electrical interference ("noise"), and also
Recognized
MODEL
SUPPLY VOLTAGE
CM3RA
105 to 130V ac, or 12 to 28V dc
CM3RB
210 to 250V ac, or 12 to 28V dc
CM5RA
105 to 130V ac, or 12 to 28V dc
CM5RB
210 to 250V ac, or 12 to 28V dc
Certified
OUTPUT
LOGIC
SPDT electromechanical relay, plus NPN transistor solidstate DC switch
ON/OFF
SPDT electromechanical relay (5 amp contact rating)
12 timing functions minimizes optical "crosstalk" between adjacent sensors. Unlike other amplifier designs, input response time settings of the CM Series modules do not affect sensor range. CM5 models include a versatile multi-function timing logic circuit which is programmable for 12 of the most popular and useful delay, one-shot, and latch functions (see page 6). Each timing function has a choice of three time ranges. Timing and sensitivity adjustments are accomplish-ed via rugged 15-turn potentiometers for very accurate settings. CM Series circuitry is designed to prevent false outputs on system power-up. An auxiliary input is available on CM5 models for interrogation or reset of the selected logic function (see example, page 17). Page 6 describes the function of the auxiliary input for each logic mode. A dc power supply is included for powering an additional self-contained dc sensor. The output circuit for all CM Series modules is an SPDT 5-amp electromechanical relay. Additionally, CM3 models have an NPN transistor solid-state switch. The output may be programmed for either normally open or normally closed operation. A solid-state relay is offered as an option to the electromechanical relay (see information below).
Solid-state Output Option CM Series modules are available with a solid-state relay which replaces the electromechanical relay. This is actually two SPST solid-state contacts. One contact will switch ac loads. The contact is rated at 250V ac maximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 amp at 50 degrees C). The other solid-state contact will switch dc loads of up to 30V dc and up to 50 milliamps. Both contacts are isolated from the MAXI-AMP power supply.
MODEL
SUPPLY VOLTAGE
CM3A
105 to 130V ac, or 12 to 28V dc
CM3B
210 to 250V ac, or 12 to 28V dc
CM5A
105 to 130V ac, or 12 to 28V dc
CM5B
210 to 250V ac, or 12 to 28V dc
OUTPUT SPST solid-state contact for switching AC loads up to 250 V ac and up to 3/4 amp, plus solid-state contact for switching DC loads up to 30V dc and up to 50mA.
LOGIC ON/OFF
12 timing functions
MAXI-AMP CR Series Modulated Modules for SP100 Series Miniature Remote Sensors The amount of amplification available from CM Series MAXI-AMP modules is too high to operate with the Banner SP100 Series of miniature modulated remote sensors. CR Series modules correct this incompatibility with a modified modulated amplifier design. CR Series specifications are exactly the same as for the standard CM Series models (listed above) except for the difference in amplifier gain. Available models are listed in the table at the right.
MODEL
SUPPLY VOLTAGE
CR3RA
105 to 130V ac, or 12 to 28V dc
CR3RB
210 to 250V ac, or 12 to 28V dc
SP100 Series sensors are ideal for OEM machinery and for tight spaces where the use of photoelectric sensors was previously considered impossible. The SP100 Series is described in the Banner catalog.
CR5RA
105 to 130V ac, or 12 to 28V dc
CR Series modules are also available with the solid-state output option (see above).
CR5RB
210 to 250V ac, or 12 to 28V dc
10
OUTPUT
LOGIC
SPDT electromechanical relay, plus NPN transistor solidstate DC switch
ON/OFF
SPDT electromechanical relay (5 amp contact rating)
12 timing functions
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Page 43
MAXI-AMP CM and CR Series Specifications SUPPLY VOLTAGE: Models CM3(R)A, CM5(R)A, CR3(R)A, and CR5(R)A: 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA. Models CM3(R)B, CM5(R)B, CR3(R)B, and CR5(R)B: 210 to 250V ac, 50/ 60Hz (4 VA), or 12 to 28V dc* at 70mA. *NOTE: do not connect ac power if using external dc power.
Functional Schematics CM5 & CR5 Models
OUTPUT CONFIGURATION: Models CM3A, CM3B, CM5A, CM5B, CR3A, CR3B, CR5A, CR5B have SPST solid-state relay for switching ac or dc (see page 10). Models CM3RA, CM3RB, CM5RA, CM5RB, CR3RA, CR3RB, CR5RA, CR5RB have SPDT electromechanical (e/m) relay with the following ratings: CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load), 1/10 H.P. at 240V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. CONTACT RESPONSE: 10 milliseconds max. open/close; 20 operations/second max. MECHANICAL LIFE: 20,000,000 operations CM3 and CR3 models also have a logic level current sinking NPN transistor switch at pin #9. See schematic (right) and hookup info.
AMPLIFIER: RESPONSE SPEED: programmable for 10, 2, or 0.3 milliseconds. NOTE: use 10 millisecond setting whenever possible for enhanced noise rejection. HYSTERESIS: if programmed "HIGH", approximately 20%; if programmed "LOW", approximately 5%. NOTE: see cautions for "LOW" setting, page 12. MODULATION FREQUENCY: approximately 10kHz. shielded cable for emitter and receiver, or order sensors with extended cable length. NOTE: see splicing precautions, page 17.
NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device (see hookup example, page 17). Current available is 40 mA at 120V ac (240V ac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power. NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latch of CM5 or CR5 models (see "Description of Logic Functions", page 6).
MULTIPLE SENSOR HOOKUP: Up to three sensors may be wired
CM3 & CR3 Models
SENSOR LEAD LENGTH: 50 feet (15 m) maximum. Use separate together to one CM-series amplifier for "OR" operation (in LIGHT operate) or "NAND" operation (in DARK operate). Emitters are connected in series, and receivers are connected in parallel. When wiring two sensors to one MAXIAMP, multiply excess gain data for each sensor by 1/2 (obtain data from applicable excess gain curve). When wiring three sensors to one MAXI-AMP, multiply excess gain by 1/3.
TIMERS (CM5 models only): TIMING RANGES: REPEATABILITY:
LOW range - 10 to 150 milliseconds MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds +/-2% of set time over all extremes of supply voltage and temperature
ADJUSTMENTS: Miniature switches for programming of LIGHT/ DARK operate, amplifier response time, amplifier hysteresis, normally open or normally closed output, and timing function (CM5 & CR5 models). 15-turn clutched potentiometer for gain and time setting(s) (CM5 and CR5 models).
OPERATING TEMPERATURE: 0 to 50°C (32 to 122°F). INDICATOR LEDs: Red indicator LED is "ON" when the module output is energized. Exclusive Banner Alignment Indicating Device (AID™) system lights a red LED indicator whenever the receiver "sees" its own modulated light source, and pulses it at a rate which is proportional to the strength of the received light signal.
CONSTRUCTION: Rugged NORYL® polyphenylene oxide (PPO®) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base.
NOTE #3: pin #9 of CM3 or CR3 models may be connected directly to the AUXILIARY input of a MAXI-AMP or Banner M Series module. It may also serve as the input to Banner CL series MAXI-AMPs or to Banner Plug Logic modules (see hookup example, page 17).
Dimension Drawing
Generalized Hookup models with electromechanical relay output
NOTE: If MAXI-AMP is powered by a dc power supply, connect +12 to 28V dc @ ≥70mA to terminal #3 and dc common to terminal #1. Make no connections to terminal #7 or #8.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
11