Page 1 of Q45VR2 Series Sensors Datasheet

Spec sheet · Banner

Q45VR2 Series Sensors Datasheet

Spec sheet11 pagesPDF 405 KB

Datasheet for the Banner Q45VR2 series AC photoelectric sensors with relay output, including the Q45VR2LVQ retroreflective model.

Download the PDF405 KB

Covers · 1 model

The models it covers

Summary

What is in it

Banner's datasheet for the Q45VR2 series of one-piece photoelectric sensors that run on 90 to 250 V AC and switch an SPDT relay. It lists every model by sensing mode (opposed, retroreflective, diffuse, convergent, glass and plastic fiber optic) with range, excess gain and beam pattern, including the Q45VR2LVQ non-polarized retroreflective model with a 5-pin Mini-style connector. It also gives specifications, dimensions, wiring diagrams, cordsets, targets, brackets and the optional timing logic and signal strength display modules.

Its parts

  1. Models
  2. Overview
  3. Specifications
  4. Dimensions
  5. Wiring Diagrams
  6. Accessories
  7. Output Timing Logic and Signal Strength Display Modules
  8. Banner Engineering Corp. Limited Warranty

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Banner datasheet (P/N 36339 Rev. H) for the Q45VR2 Series photoelectric sensors, which run on 90 to 250 V ac and switch an SPDT relay. It covers opposed, retroreflective, diffuse, convergent and fiber optic models, among them the Q45VR2LVQ non-polarized retroreflective model with a 5-pin Mini-style connector, plus specifications, dimensions, wiring and accessories.

Sensing mode
Q45VR2LVQ: non-polarized retroreflective, visible red 680 nm, range 0.08 to 9 m (3 in to 30 ft) with a BRT-3 reflector p. 2
Connection
Q45VR2LVQ: 5-Pin Mini-style quick-disconnect; mating cable ordered separately p. 2, 7
Supply
90 to 250 V ac (50/60 Hz), average current 20 mA p. 7
Output
SPDT electromechanical relay, max. 5 A at 250 V ac resistive; max. 250 V ac, 30 V dc; 150 W, 600 VA p. 7
Response time
15 milliseconds ON and OFF; 100 millisecond delay on power-up p. 7
Environmental rating
NEMA 6P, IEC IP67; built for 1200 psi washdown p. 7
Operating temperature
−40 °C to +70 °C (−40 °F to +158 °F); max. 90% relative humidity at 50 °C, non-condensing p. 7
Relay life
10,000,000 operations mechanical; 100,000 operations at full resistive load p. 7
Adjustments
Light/dark operate switch and multi-turn sensitivity control under the sealed cover p. 6, 7
Indicators
Green power, red signal (AID System) and amber output LEDs p. 6, 7
5-pin cordsets
MBCC-506 (1.83 m), MBCC-512 (3.66 m), MBCC-530 p. 9
Mounting
M30 x 1.5 external thread with hex nut supplied; brackets SMB30C, SMB30MM, SMB30SC p. 8, 10
Plug-in modules
45LM58 timing logic, 45LM58D timing logic plus signal strength display, 45LMD display only p. 10
Construction
Thermoplastic polyester housing, o-ring-sealed polycarbonate cover, acrylic lenses, stainless steel hardware p. 7

What this sheet walks you through

  • Choosing a model by sensing mode, range and connection p. 1, 2, 3, 4, 5, 6
  • Reading the indicator LEDs and setting sensitivity and light/dark operate p. 6
  • Sizing overcurrent protection for the supply wiring p. 7
  • Checking sensor dimensions for mounting p. 8
  • Wiring cabled and quick-disconnect sensors p. 9
  • Selecting cordsets, reflectors and mounting brackets p. 9, 10
  • Adding output timing logic or a signal strength display module p. 10

Good to know

  • Not to be used for personnel protection: it lacks the self-checking redundant circuitry needed for safety applications. p. 1
  • Transient suppression is recommended when the relay contacts switch inductive loads. p. 7
  • Polarized sensors need corner cube type retroreflective targets; non-polarized sensors may use any retroreflective target. p. 10
  • The output stays de-energized for 100 milliseconds after power-up. p. 7
  • Supply wiring leads smaller than 24 AWG must not be spliced. p. 7

Questions this sheet answers

What is the sensing range of the Banner Q45VR2LVQ?

0.08 to 9 m (3 in to 30 ft) in non-polarized retroreflective mode, specified with a BRT-3 reflector. p. 2

What voltage does the Q45VR2LVQ run on?

90 to 250 V ac at 50/60 Hz. p. 7

What cable fits the Q45VR2LVQ?

A 5-pin Mini-style cordset such as the MBCC-506, MBCC-512 or MBCC-530; QD cables are ordered separately. p. 2, 7, 9

How much current can the Q45VR2 relay switch?

Up to 5 A at 250 V ac with a resistive load; minimum 5 V dc, 0.1 mA. p. 7

Can a timer be added to the Q45VR2LVQ?

Yes. The 45LM58 and 45LM58D plug-in modules add programmable output timing logic and fit all Q45VR2 sensors. p. 10

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Q45VR2 Series Sensors1
  2. Models1
    1. Opposed-Mode Emitter (E) and Receiver (R) Models1
    2. Retroreflective-Mode Models2
    3. Diffuse-Mode Models3
    4. Convergent-Mode Models4
    5. Glass Fiber Optic Models5
    6. Plastic Fiber Optic Models6
  3. Overview6
  4. Specifications7
  5. Dimensions8
  6. Wiring Diagrams9
  7. Accessories9
    1. Cordsets9
    2. Retroreflective Targets10
    3. Brackets10
  8. Output Timing Logic and Signal Strength Display Modules10
  9. Banner Engineering Corp. Limited Warranty11

From the PDF’s own bookmarks.

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 117-11

The file

Revision and size

RevisionP/N 36339 Rev. H, 30 January 2017
PublisherBanner Engineering Corp.
Pages11
PDF405 KB
TextText from the PDF itself.

The first pages · 4 of 11

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 11
Page 2
Page 2of 11
Page 3
Page 3of 11
Page 4
Page 4of 11