Spec sheet · Banner
Q45VR2 Series Sensors Datasheet
Spec sheet11 pagesPDF 405 KB
Datasheet for the Banner Q45VR2 series AC photoelectric sensors with relay output, including the Q45VR2LVQ retroreflective model.
Covers · 1 model
The models it covers
Summary
What is in it
Banner's datasheet for the Q45VR2 series of one-piece photoelectric sensors that run on 90 to 250 V AC and switch an SPDT relay. It lists every model by sensing mode (opposed, retroreflective, diffuse, convergent, glass and plastic fiber optic) with range, excess gain and beam pattern, including the Q45VR2LVQ non-polarized retroreflective model with a 5-pin Mini-style connector. It also gives specifications, dimensions, wiring diagrams, cordsets, targets, brackets and the optional timing logic and signal strength display modules.
Its parts
- Models
- Overview
- Specifications
- Dimensions
- Wiring Diagrams
- Accessories
- Output Timing Logic and Signal Strength Display Modules
- Banner Engineering Corp. Limited Warranty
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Banner datasheet (P/N 36339 Rev. H) for the Q45VR2 Series photoelectric sensors, which run on 90 to 250 V ac and switch an SPDT relay. It covers opposed, retroreflective, diffuse, convergent and fiber optic models, among them the Q45VR2LVQ non-polarized retroreflective model with a 5-pin Mini-style connector, plus specifications, dimensions, wiring and accessories.
- Sensing mode
- Q45VR2LVQ: non-polarized retroreflective, visible red 680 nm, range 0.08 to 9 m (3 in to 30 ft) with a BRT-3 reflector p. 2
- Connection
- Q45VR2LVQ: 5-Pin Mini-style quick-disconnect; mating cable ordered separately p. 2, 7
- Supply
- 90 to 250 V ac (50/60 Hz), average current 20 mA p. 7
- Output
- SPDT electromechanical relay, max. 5 A at 250 V ac resistive; max. 250 V ac, 30 V dc; 150 W, 600 VA p. 7
- Response time
- 15 milliseconds ON and OFF; 100 millisecond delay on power-up p. 7
- Environmental rating
- NEMA 6P, IEC IP67; built for 1200 psi washdown p. 7
- Operating temperature
- −40 °C to +70 °C (−40 °F to +158 °F); max. 90% relative humidity at 50 °C, non-condensing p. 7
- Relay life
- 10,000,000 operations mechanical; 100,000 operations at full resistive load p. 7
- Adjustments
- Light/dark operate switch and multi-turn sensitivity control under the sealed cover p. 6, 7
- Indicators
- Green power, red signal (AID System) and amber output LEDs p. 6, 7
- 5-pin cordsets
- MBCC-506 (1.83 m), MBCC-512 (3.66 m), MBCC-530 p. 9
- Mounting
- M30 x 1.5 external thread with hex nut supplied; brackets SMB30C, SMB30MM, SMB30SC p. 8, 10
- Plug-in modules
- 45LM58 timing logic, 45LM58D timing logic plus signal strength display, 45LMD display only p. 10
- Construction
- Thermoplastic polyester housing, o-ring-sealed polycarbonate cover, acrylic lenses, stainless steel hardware p. 7
What this sheet walks you through
- Choosing a model by sensing mode, range and connection p. 1, 2, 3, 4, 5, 6
- Reading the indicator LEDs and setting sensitivity and light/dark operate p. 6
- Sizing overcurrent protection for the supply wiring p. 7
- Checking sensor dimensions for mounting p. 8
- Wiring cabled and quick-disconnect sensors p. 9
- Selecting cordsets, reflectors and mounting brackets p. 9, 10
- Adding output timing logic or a signal strength display module p. 10
Good to know
- Not to be used for personnel protection: it lacks the self-checking redundant circuitry needed for safety applications. p. 1
- Transient suppression is recommended when the relay contacts switch inductive loads. p. 7
- Polarized sensors need corner cube type retroreflective targets; non-polarized sensors may use any retroreflective target. p. 10
- The output stays de-energized for 100 milliseconds after power-up. p. 7
- Supply wiring leads smaller than 24 AWG must not be spliced. p. 7
Questions this sheet answers
What is the sensing range of the Banner Q45VR2LVQ?
0.08 to 9 m (3 in to 30 ft) in non-polarized retroreflective mode, specified with a BRT-3 reflector. p. 2
What voltage does the Q45VR2LVQ run on?
90 to 250 V ac at 50/60 Hz. p. 7
What cable fits the Q45VR2LVQ?
A 5-pin Mini-style cordset such as the MBCC-506, MBCC-512 or MBCC-530; QD cables are ordered separately. p. 2, 7, 9
How much current can the Q45VR2 relay switch?
Up to 5 A at 250 V ac with a resistive load; minimum 5 V dc, 0.1 mA. p. 7
Can a timer be added to the Q45VR2LVQ?
Yes. The 45LM58 and 45LM58D plug-in modules add programmable output timing logic and fit all Q45VR2 sensors. p. 10
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file