The text of a spec sheet · part 2 of 2
Q45VR2 Series Sensors Datasheet, pages 7 to 11
Pages 7 to 11 of 11
The original document is the PDF (405 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Banner Q45VR2LVQ
Page 7
Q45VR2 Series Sensors
Specifications Supply Voltage and Current 90 to 250 V ac (50/60 Hz) Average current 20 mA Peak current 500 mA at 120 V ac, 750 mA at 250 V ac
Repeatability Opposed mode: 0.25 milliseconds All other sensing modes: 0.5 milliseconds Response time and repeatability specifications are independent of signal strength.
Supply Protection Circuitry Protected against transient voltages Output Configuration SPDT (Single-Pole Double-Throw) electromechanical relay output. All models except emitters. Output Rating Max. switching power (resistive load): 150 W, 600 VA Max. switching voltage (resistive load): 250 V ac, 30 V dc Max. switching current (resistive load): 5 A at 250 V ac Min. voltage and current: 5 V dc, 0.1 mA Mechanical life of relay: 10,000,000 operations Electrical life of relay at full resistive load: 100,000 operations Output Protection Circuitry Protected against false pulse on power-up Output Response Time 15 milliseconds ON and OFF Note: 100 millisecond delay on power-up. Output is de-energized during this time Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
P/N 36339 Rev. H
Adjustments Light/Dark Operate select switch and multi-turn Sensitivity control (allows precise sensitivity setting – turn clockwise to increase gain). Optional logic and logic/display modules have adjustable timing functions. Indicators Indicator LEDs are clearly visible beneath a raised transparent Lexan® dome on top of the sensor Power (green) LED lights when 90 to 250 V ac power is applied Signal (red) AID™ System LED lights when the sensor sees its modulated light source and pulses at a rate proportional to the strength of the received light signal Load (amber) LED lights whenever the output relay is energized Optional 7-element LED signal strength display modules Construction Molded reinforced thermoplastic polyester housing, o-ring-sealed transparent polycarbonate cover, molded acrylic lenses, and stainless steel hardware. Q45s are designed to withstand 1200 psi washdown. The base of cabled models has a 1/2-inch NPS integral internal conduit thread. Connections PVC-jacketed 2-wire (emitters) or 5-wire (all others) 2 m (6.5 ft) or 9 m (30 ft) unterminated cables, or 3-pin (emitters) or 5-pin (all others) Mini-style quickdisconnect (QD) fittings are available (“Q” - suffix models). QD cables are ordered separately. Application Notes Transient suppression is recommended for contacts switching inductive loads. Optional output timing modules are available. Environmental Rating NEMA 6P, IEC IP67 Operating Conditions Temperature: −40 °C to +70 °C (−40 °F to +158 °F) Maximum relative humidity: 90% at 50 °C (non-condensing) Certifications www.bannerengineering.com - Tel: +1-763-544-3164
7
Page 8
Q45VR2 Series Sensors
Dimensions Opposed, Retro, and Diffuse Sensing Modes (Model Suffix E, R, D, DL, DX, LP, and LV) Cabled Models
Quick-Disconnect Models
Transparent Cover (Gasketed) View: Output Load Status Open to Access: Sensitivity (Gain) Adjustment 54.1 mm (2.13") 44.5 mm (1.75")
Lens Centerline
50.8 mm (2.00") 69.0 mm (2.72") 6.4 mm (0.25")
87.6 mm (3.45")
4.5 mm (#10) Screw Clearance (2) 7.1 mm (0.28") 30.0 mm (1.18") Internal Thread (1/2–14NPSM) External thread (M30 x 1.5) hex nut supplied
External Thread M30 X 1.5 14 mm (0.6")
Mini-style QD Connector
Convergent Sensor Models
Glass Fiber Optic Models
Plastic Fiber Optic Models
(CV and CV4)
(F and FV)
(FP)
61.7 mm (2.43")
8
ø 6.1 (0.24") 2m (6.5') Cable
60.5 mm (2.38")
www.bannerengineering.com - Tel: +1-763-544-3164
59.9 mm (2.36")
P/N 36339 Rev. H
Page 9
Q45VR2 Series Sensors
Wiring Diagrams Sensors with Attached Cable
Sensors with Quick-Disconnect 5-Pin Mini-Style (model suffix Q)
brown brown blue
90–250 V ac blue
90–250 V ac white
NC white
NC
C yellow
NO black yellow black
Q452E Emitter with Attached Cable
NO
Q452E Emitter with Quick-Disconnect 3-Pin Mini-Style (model suffix Q)
brown brown blue
C blue
90–250 V ac
90–250 V ac black
Accessories 3-Pin Mini-Style Cordsets Model
Length
MBCC-306
1.83 m (6.5 ft)
MBCC-312
3.66 m (12 ft)
MBCC-330
9.14 m (30 ft)
SMICC-306
1.83 m (6.5 ft)
SMICC-312
3.66 m (12 ft)
SMICC-330
9.14 m (30 ft)
SM30CC-306
1.83 m (6.5 ft)
SM30CC-312
3.66 m (12 ft)
Style
Dimensions
Pinout (Female)
1
Straight 52 Typ.
Straight
7/8-16UN-2B
2
3
1 = Black 2 = Brown 3 = Blue
ø 25.5
1 = Red/Black 2 = Red/White 3 = Green
Straight
5-Pin Mini-Style Cordsets Model
Length
MBCC-506
1.83 m (6 ft)
MBCC-512
3.66 m (12 ft)
Style
Dimensions
Pinout (Female)
52 Typ.
7/8-16UN-2B
P/N 36339 Rev. H
ø 25.5
9.14 m (30 ft)
www.bannerengineering.com - Tel: +1-763-544-3164
2
4 3
Straight MBCC-530
1
5
1 = Black 2 = Blue 3 = Yellow 4 = Brown 5 = White
9
Page 10
Q45VR2 Series Sensors
Retroreflective Targets Banner offers a wide selection of high-quality retroreflective targets. See www.bannerengineering.com for complete information. Note: Polarized sensors require corner cube type retroreflective targets. Non-polarized sensors may use any retroreflective target.
Brackets SMB30C • 30 mm split clamp, black PBT bracket • Stainless steel mounting hardware included • Mounting hole for 30 mm sensor
56 A 66 B
13
Hole center spacing: A=ø 45 Hole size: B=ø 27.2
SMB30MM • 12-ga. stainless steel bracket with curved mounting slots for versatile orientation • Clearance for M6 (¼ in) hardware • Mounting hole for 30 mm sensor
57
70 C
57
B A
Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
SMB30SC • Swivel bracket with 30 mm mounting hole for sensor • Black reinforced thermoplastic polyester • Stainless steel mounting and swivel locking hardware included
67 B 58
29
A
Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0
Output Timing Logic and Signal Strength Display Modules Q45 sensors easily accept the addition of output timing logic and signal strength display functions. Display modules have a sevenelement display that gives a more precise indication of excess gain than does the AID™ system LED that is standard on Q45 sensors. The modules listed below may be used with all Q45VR2 sensors. Refer to the module's datasheet for more information. Models
Logic and/or Display Function
45LM58
Programmable output timing logic
45LM58D
Programmable output timing logic plus signal strength display
45LMD
Signal strength display only (no timing function)
10 www.bannerengineering.com - Tel: +1-763-544-3164
P/N 36339 Rev. H
Page 11
Q45VR2 Series Sensors
Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
© Banner Engineering Corp. All rights reserved