For the Banner S18SN6D

Page 19

MINI-BEAM® Expert™ Series Compact Sensors

Supply Voltage and Current

10 to 30V dc (10% max. ripple) at less than 45 mA, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor. Configuration in TEACH sequence for Light Operate (LO) or Dark Operate (DO).

Output Rating

150 mA max. each output at 25° C, derated to 100 mA at 70° C (derate ≈ 1 mA per ° C) Off-state leakage current: less than 5 µA @ 30V dc Output saturation voltage (PNP output): less than 1 volt at 10 mA and less than 2 volts at 150 mA Output saturation voltage (NPN output): less than 200 millivolts at 10 mA and less than 1 volt at 150 mA

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short-circuit of outputs

Output Response Time

Sensors will respond to either a “light” or a “dark” signal of 500 microseconds or longer duration, 1 kHz max. NOTE: 1 second delay on power-up; outputs do not conduct during this time.

Repeatability

100 microseconds (all models)

Adjustments

Push-button TEACH mode sensitivity setting; remote TEACH mode input is provided (gray wire)

Indicators

Two LEDs: Yellow and Bicolor Green/Red

PHOTOELECTRICS

MINI-BEAM® Expert™ Specifications

Green (RUN Mode):

ON when power is applied Flashes when received light level approaches the switching threshold Red (TEACH Mode): OFF when no signal is received. Pulses to indicate signal strength (received light level). Rate is proportional to signal strength (the stronger the signal, the faster the pulse rate). This is a function of Banner’s Alignment Indicating Device (AID). Yellow (TEACH Mode): ON to indicate sensor is ready to learn output ON condition OFF to indicate sensor is ready to learn output OFF condition Yellow (RUN Mode): ON when outputs are conducting Construction

Reinforced thermoplastic polyester housing, totally encapsulated, o-ring seal, acrylic lenses, and stainless steel screws.

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67

Connections

PVC-jacketed 5-conductor 2 m or 9 m unterminated cable, or 5-pin Euro-style quick-disconnect (QD) fitting are available. QD cables are ordered separately. See page 382.

Operating Conditions

Temperature: -20° to +70° C

Application Notes

The first condition presented during TEACH mode becomes the output ON condition.

Relative humidity: 90% at 50° C (non-condensing)

Certifications

Hookup Diagrams

DC11 (p. 478)

More information online at bannerengineering.com

83

Page 20

MINI-BEAM® Universal Voltage Series Compact Sensors PHOTOELECTRICS

MINI-BEAM® Universal Voltage Sensors

Opposed, Retroreflective, Diffuse and Convergent Models Suffix E, EL, R, RL, LV, LP, D, CV and CV2

Popular, compact MINI-BEAM package with a SPDT electromechanical (E/M) relay

30.7 mm 12.2 mm

Universal supply voltage: 24 to 240V ac, 50/60 Hz; 24 to 240V dc

30.7 mm

Easy-tooperate sensors with few required adjustments

12.2 mm

81.0 mm 12.2 mm

66.8 mm

12.2 mm 30.7 mm

Diffuse Models Suffix W

30.7 mm

Detailed Dimensions 85.3 mm 69.8 mm

Plastic Fiber Models Suffix FP

Glass Fiber Models Suffix F and FV

MINI-BEAM® Universal Voltage, 24-240V ac or dc Models

Sensing Mode/LED*

SMU31E Emitter SMU31R SMU31EL Emitter SMU31RL

OPPOSED

SMU315LV

Excess Gain

Beam Pattern

2m

EGCO-12 (p. 428)

BPO-12 (p. 450)

30 m

2m

EGCO-13 (p. 428)

BPO-13 (p. 450)

5 m†

2m

EGCR-16 (p. 431)

BPR-15 (p. 453)

10 mm - 3 m†

2m

EGCR-17 (p. 432)

BPR-16 (p. 453)

Range

Cable**

3m

Output Type

Download PDF

Data Sheet

RETRO

SMU315LP

P POLAR RETRO

SMU315D

SPDT E/M Relay

380 mm

2m

EGCD-19 (p. 435)

BPD-18 (p. 457)

130 mm

2m

EGCD-20 (p. 435)

BPD-19 (p. 457)

16 mm

2m

EGCC-26 (p. 438)

BPC-26 (p. 460)

43 mm

2m

EGCC-27 (p. 438)

BPC-27 (p. 460)

55230

DIFFUSE DIVERGENT

SMU315W DIFFUSE

SMU315CV SMU315CV2

CONVERGENT

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, SMU315D W/30). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

84

More information online at bannerengineering.com

Page 21

MINI-BEAM® Universal Voltage Series Compact Sensors

Models

Sensing Mode/LED*

SMU315F GLASS FIBER

SMU315FV

Range

Cable** 2m

Range varies by sensing mode and fiber optics used

2m

GLASS FIBER

SMU315FP PLASTIC FIBER

Output Type

Range varies by sensing mode and fiber optics used

SPDT E/M Relay

2m

PHOTOELECTRICS

MINI-BEAM® Universal Voltage, 24-240V ac or dc (cont’d)

Download PDF

Excess Gain

Beam Pattern

EGCG-16 (p. 444) & EGCG-17 (p. 445)

BPG-16 (p. 462) & BPG-17 (p. 463)

EGCG-18 & EGCG-19 (p. 445)

BPG-18 & BPG-19 (p. 463)

EGCP-12 & EGCP-13 (p. 447)

BPP-12 & BPP-13 (p. 465)

Data Sheet

55230

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, SMU315F W/30).

MINI-BEAM® Universal Voltage Specifications Supply Voltage

Universal voltage: 24 to 240V ac, 50/60Hz or 24 to 240V dc (1.5 watts or 2.5 VA max.)

Supply Protection Circuitry

Protected against transient voltages. DC hookup is without regard to polarity.

Output Configuration

SPDT (Single-Pole, Double Throw) (form C) electromechanical relay, ON/OFF output.

Output Rating

Max. switching power (resistive load): 90W, 250VA Max. switching voltage (resistive load): 250V ac or 30V dc Max. switching current (resistive load): 3A Min. voltage and current: 5V dc, 10 mA Mechanical life: 20,000,000 operations Electrical life at full resistive load: 100,000 operations

Output Protection Circuitry

Protected against false pulse on power-up.

Output Response Time

Closure time: 20 milliseconds max. Release time: 20 milliseconds max. Max. switching speed: 25 operations per second

Repeatability

All sensing modes: 1 millisecond

Adjustments

Light/Dark Operate select switch, and 15-turn slotted brass screw Gain (sensitivity) adjustment potentiometer (clutched at both ends of travel). Both controls are located on rear panel of sensor and are protected by a gasketed, clear acrylic cover.

Indicators

Alignment Indicator Device system (AID) lights a rear-panel-mounted LED indicator whenever the sensor sees a “light” condition, with a superimposed pulse rate proportional to the light signal strength (the stronger the signal, the faster the pulse rate).

Construction

Reinforced thermoplastic polyester housing, totally encapsulated, o-ring seal, acrylic lenses, and stainless steel screws.

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67.

Connections

PVC-jacketed 5-conductor 2 m or 9 m unterminated cable. Opposed mode emitter cables are 2-conductor.

Operating Conditions

Temperature: -20° to +55° C

Application Notes

Install transient suppressor (MOV) across contacts switching inductive loads.

Relative humidity: 90% at 50° C (non-condensing)

Certifications

Hookup Diagrams

Emitters: UN02 (p. 487)

Other AC/DC Models: UN01 (p. 487)

More information online at bannerengineering.com

85

Page 22

MINI-BEAM® NAMUR Series Compact Sensors

12.2 mm

PHOTOELECTRICS

MINI-BEAM® NAMUR Sensors 30.7 mm

Intrinsically safe sensors with MINI-BEAM performance and small size 30.7 mm

For use with approved switching amplifiers with intrinsically safe input circuits

51.8 mm

Diffuse Models Suffix W

Output 1 mA or less in the dark and 2 mA or more in the light

12.2 mm

Models with integral cable or quick-disconnect

66.0 mm

12.2 mm

30.7 mm

Opposed, Retroreflective, Diffuse and Convergent Models Suffix E, R, LV, D, and CV 69.9 mm

Detailed Dimensions

Glass Fiber Models Suffix F

MINI-BEAM® NAMUR, 5-15V dc Models

Sensing Mode/LED*

Range

Download PDF

Cable** 2m 4-Pin Euro QD

MI9E Emitter MI9EQ Emitter

Output Type

MIAD9LV MIAD9LVQ MIAD9LVAG MIAD9LVAGQ MIAD9D MIAD9DQ

2m 4-Pin Euro QD

OPPOSED

EGCR-18 (p. 432)

BPR-17 (p. 454)

50 mm - 2 m

2m 4-Pin Euro QD

EGCR-19 (p. 432)

BPR-18 (p. 454)

380 mm

2m 4-Pin Euro QD

EGCD-21 (p. 435)

BPD-20 (p. 457)

EGCD-22 (p. 435)

BPD-21 (p. 457)

DIFFUSE

DIVERGENT

75 mm

MIAD9WQ

2m 4-Pin Euro QD

DIFFUSE

Constant Current ≤1.2 mA dark ≥2.1 mA light

16 mm

2m 4-Pin Euro QD

EGCC-28 (p. 438)

BPC-28 (p. 460)

CONVERGENT

43 mm

2m 4-Pin Euro QD

EGCC-29 (p. 438)

BPC-29 (p. 460)

2m 4-Pin Euro QD

EGCG-20 & EGCG-21 (p. 445)

BPG-20 & BPG-21 (p. 463)

GLASS FIBER

Range varies by sensing mode and fiber optics used

MIAD9CV MIAD9CVQ MIAD9CV2 MIAD9CV2Q

BPO-14 (p. 450)

2m 4-Pin Euro QD

POLAR RETRO

MIAD9W

EGCO-14 (p. 428)

5m RETRO

P

Beam Pattern

MIAD9F MIAD9FQ

Data Sheet, 6m MIAD9R MIAD9RQ

Excess Gain

39616

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, MIAD9LV W/30). A model with a QD requires a special 4-pin Euro QD mating cable (see page 381). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

86

More information online at bannerengineering.com

Page 23

MINI-BEAM® NAMUR Series Compact Sensors

Supply Voltage

5 to 15V dc (provided by the amplifier to which the sensor is connected)

Output

Constant current output: ≤ 1.2 mA in the “dark” condition and ≤ 2.1 mA in the “light” condition

Output Response Time

Opposed mode receiver: 2 milliseconds on/400 microseconds off All other models: 5 milliseconds on/off (does not include amplifier response)

Adjustments

15-turn slotted brass screw GAIN (sensitivity) adjustment potentiometer (clutched at both ends of travel); located on rear panel and protected by a clear gasketed acrylic cover

Indicators

Red LED Alignment Indicator Device (AID) located on rear panel lights when the sensor sees a “light” condition; pulse rate is proportional to signal strength (the stronger the signal, the faster the pulse rate).

Construction

Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, and stainless steel screws

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12 and 13; IEC IP67

Connections

PVC-jacketed 2-conductor 2 m or 9 m cables, or special 4-pin Euro-style quick-disconnect (QD) fitting are available; QD cables are ordered separately. See page 381.

Operating Conditions

Temperature: -40° to +70° C

Design Standards

MIAD9 Series sensors comply with the following standards: DIN 19 234, EN 50 014 Part 1. 1977, EN50 020 Part 7. 1977, Factory Mutual #3610 and 3611, CSA 22.2 #157-92 and 22.2 #213-M1987

PHOTOELECTRICS

MINI-BEAM® NAMUR Specifications

Relative humidity: 90% at 50° C (non-condensing)

Certifications LISTE D

Hookup Diagrams

SP02 (p. 489)

APPROVALS CSA:

#LR 41887

Instrinsically Safe, with Entity for Class I, Groups A-D Class I, Div. 2, Groups A-D

FM:

#J.I. 5Y3A4.AX

Intrinsically Safe, with Entity for Class I, II, III, Div. 1, Groups A-G Class I, II, III, Div. 2, Groups A-D and G

KEMA:

#03ATEX1441X

II IG EEx ia IIC T6

ETL:

#553868

More information online at bannerengineering.com

87

Page 24

Q23 Series Compact Sensors PHOTOELECTRICS

Q23 and QH23 Vertical and Horizontal Rectangular Sensors • Available with vertical and horizontal housings • Delivers high power in a small package • Features ranges up to 8 m • Uses a powerful visible red sensing beam for easy setup and alignment • Offered in opposed, polarized retroreflective, convergent, diffuse and plastic fiber optic modes • Features marginal gain indicator with alarm output

OPPOSED

P POLAR RETRO

DIFFUSE

CONVERGENT

23.0 mm

Q23 and QH23 Sensors PLASTIC FIBER

BRACKETS

PAGE 350 QD CABLES

4-Pin Pico

Dual-LED multi-function indicators

Detailed Dimensions

34.0 mm

Two housing styles

34.0 mm

2 m or 9 m integral cable, or 150 mm Pico-style quickdisconnect pigtail

23.0 mm

PAGE 378 REFLECTORS

12.0 mm

PAGE 391

PAGE 406

12.0 mm

12.0 mm

APERTURES

Opposed, Retroreflective and Diffuse Models Suffix E, R, LP and D

34.0 mm

12.0 mm

23.0 mm 25.5 mm

12.0 mm 12.0 mm

Q23 Convergent Models Suffix CV

36.5 mm

34.0 mm 23.0 mm

88

27.1 mm

38.1 mm

Q23 Plastic Fiber Optic Models Suffix FP and FPY

QH23 Plastic Fiber Optic Models Suffix FP and FPY

More information online at bannerengineering.com

QH23 Convergent Models Suffix CV

Page 25

Q23 Series Compact Sensors

Models

Sensing Mode/LED*

Range

Q236E Emitter QH236E Emitter

PHOTOELECTRICS

Q23 and QH23, 10-30V dc

Download PDF

Cable**

Output Type

Excess Gain

Pattern

Beam

Data Sheet

EGCO-15 (p. 428)

BPO-15 (p. 450)

46637

EGCR-20 (p. 432)

BPR-19 (p. 454)

46637

EGCD-23 (p. 435)

BPD-22 (p. 457)

2m

– Q236EQ Emitter QH236EQ Emitter

4-pin Pico Pigtail QD

Q23SN6R QH23SN6R

2m

NPN

8m Q23SN6RQ QH23SN6RQ

4-pin Pico Pigtail QD

OPPOSED

Q23SP6R QH23SP6R

2m

Q23SP6RQ QH23SP6RQ

4-pin Pico Pigtail QD

Q23SN6LP QH23SN6LP

2m

Q23SN6LPQ QH23SN6LPQ

4-pin Pico Pigtail QD

PNP

NPN

Q23SP6LP QH23SP6LP

P

100 mm - 2 m† 2m

POLAR RETRO

PNP Q23SP6LPQ QH23SP6LPQ

4-pin Pico Pigtail QD

Q23SN6D QH23SN6D

2m

Q23SN6DQ QH23SN6DQ

NPN

SHORT-RANGE

4-pin Pico Pigtail QD 200 mm

Q23SP6D QH23SP6D

2m

DIFFUSE

PNP Q23SP6DQ QH23SP6DQ

4-pin Pico Pigtail QD 46637

Q23SN6DL QH23SN6DL Q23SN6DLQ QH23SN6DLQ

2m

NPN

LONG-RANGE

4-pin Pico Pigtail QD EGCD-24 (p. 435)

800 mm Q23SP6DL QH23SP6DL

DIFFUSE

BPD-23 (p. 457)

2m

PNP Q23SP6DLQ QH23SP6DLQ

4-pin Pico Pigtail QD

Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, Q23SN6D W/30). A model with a pigtail QD requires a mating cable (see page 378). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

More information online at bannerengineering.com

89

Page 26

Q23 Series Compact Sensors PHOTOELECTRICS

Q23 and QH23, 10-30V dc (cont’d) Models

Sensing Mode/LED*

Range

Q23SN6CV50 QH23SN6CV50

Cable**

Download PDF

Output Type

Excess Gain

Pattern

Beam

EGCC-30 (p. 438)

BPC-30 (p. 460)

EGCP-14 & EGCP-15 (p. 447)

BPP-14 & BP-15 (p. 465)

Data Sheet

2m

NPN Q23SN6CV50Q QH23SN6CV50Q

4-pin Pico Pigtail QD 50 mm

Q23SP6CV50 QH23SP6CV50

46637

2m

CONVERGENT

PNP Q23SP6CV50Q QH23SP6CV50Q

4-pin Pico Pigtail QD

Q23SN6FP QH23SN6FP Q23SN6FPQ QH23SN6FPQ Q23SP6FP QH23SP6FP

2m

NPN

Standard Speed: 1 ms

4-pin Pico Pigtail QD

2m

PLASTIC FIBER

PNP Q23SP6FPQ QH23SP6FPQ

Range varies by sensing mode and fiber optics used

Q23SN6FPY QH23SN6FPY Q23SN6FPYQ QH23SN6FPYQ Q23SP6FPY QH23SP6FPY

46637 2m

NPN

High Speed: 100 µs

4-pin Pico Pigtail QD

PLASTIC FIBER

Q23SP6FPYQ QH23SP6FPYQ * **

4-pin Pico Pigtail QD

EGCP-16 (p. 447) & EGCP-17 (p. 448)

2m

BPP-16 (p. 465) & BPP-17 (p. 466)

PNP 4-pin Pico Pigtail QD

Visible Red LED For 9 m cable, add suffix W/30 to the 2 m model number (example, Q23SN6CV50 W/30). A model with a pigtail QD requires a mating cable (see page 378).

Q23 and QH23 Specifications

90

Supply Voltage and Current

10 to 30V dc (10% max. ripple) at less than 25 mA for diffuse, Retroreflective, and fiber optic models (exclusive of load) Opposed emitters and receivers draw 20 mA each

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.

Output Rating

150 mA max. each in standard hookup; when wired for alarm output, the total load may not exceed 150 mA Off-state leakage current: less than 1 mA at 30V dc Output saturation voltage: less than 1 volt at 10 mA dc; less than 1.5V at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up, transient voltages, and continuous overload or short-circuit of outputs

Output Response Time

All other models: 1 millisecond ON/OFF Q23FPQ high-speed models: 100 microsecond ON/OFF; protected against false pulse on power-up NOTE: 100 millisecond delay on power-up: outputs do not conduct during this time.

More information online at bannerengineering.com

Page 27

Q23 Series Compact Sensors

Repeatability

Opposed: 0.13 milliseconds; Retroreflective and Diffuse: 0.25 milliseconds FPY High-Speed Plastic Fiber Optic: 25 microseconds Response time and repeatability specifications are independent of signal strength.

Adjustments

SENSITIVITY control (single-turn, o-ring sealed potentiometer)

Indicators

Sensors except opposed mode emitters have two LEDs: Green ON steady: dc power ON Green flashing: output overload Yellow ON steady: Light Operate (LO), output is energized Yellow flashing: marginal excess gain (1 - 1.5x), LO output is energized Emitters have green power “ON” indicator

Construction

Yellow and black ABS housing, with acrylic lenses, completely sealed. Stainless steel mounting bracket and M3 mounting hardware are supplied

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67. Housing materials rated UL 94 V-0

Connections

PVC-jacketed 4-conductor 2 m or 9 m cables, or 4-pin Pico-style 50 mm threaded quick-disconnect (QD) fitting are available. Mating QD cables are ordered separately. See page 378.

Operating Conditions

Temperature: -20° to +55° C

Application Notes

To avoid damage to the sensor caused by static discharge (ESD), use the plastic screwdriver supplied with each sensor (included in the hardware packet) to adjust the SENSITIVITY control. Otherwise, use a screwdriver with an insulated handle.

PHOTOELECTRICS

(cont’d) Q23 Q23 and and QH23 Specifications (cont’d) QH23 Specifications

Relative humidity: 90% at 50° C (non-condensing)

Certifications

Hookup Diagrams

Emitters: DC03 (p. 476)

NPN Models: DC07 (p. 477)

PNP Models: DC08 (p. 477)

More information online at bannerengineering.com

91