The text of a spec sheet · part 4 of 5
Compact Sensors (Photoelectrics), pages 28 to 36
Pages 28 to 36 of 42
The original document is the PDF (8.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Banner S18SN6D
Page 28
S18/M18 Series Compact Sensors PHOTOELECTRICS
S18 and M18 18 mm ThreadedBarrel Sensors • Features EZ-BEAM® technology, with specially designed optics and electronics for reliable sensing without adjustments • Available in plastic threaded barrel sensor (S18) and stainless steel threaded barrel sensor (M18) • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments (S18) • Uses innovative dual-indicator system to take the guesswork out of monitoring sensor performance • Available in models for ac or dc power • Includes advanced diagnostics to warn of marginal sensing conditions or output overload (dc models) • Meets rigorous IP69K standards for use in 1200 psi washdowns (S18) OPPOSED
RETRO
S18 DC Models. . . . . . . . . . . . . . . . . . . . . . . .Page 93 M18 DC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 S18 AC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
P POLAR RETRO
S18 and M18 DC Sensors DIFFUSE
FIXED-FIELD
BRACKETS
PAGE 350 QD CABLES
Advanced self-diagnostics with separate alarm output; dual-LED multi-function indicators
S18 Opposed, Non-polarized Retroreflective and Diffuse Models Suffix E, R, L and D 59.2 mm
Popular 18 mm threaded barrel
65.0 mm
ø 18.0 mm
10 to 30V dc with NPN or PNP outputs
S18 Polarized Retroreflective and Fixed-field Models Suffix LP and FF
4-Pin Euro + 4-Pin Micro
PAGE 380 & 386 REFLECTORS
2 m or 9 m integral cable, or Euro-style quick-disconnect fitting
PAGE 391
ø 18.0 mm
APERTURES
PAGE 406
Detailed Dimensions
65.0 mm
59.2 mm
M18 Opposed, Non-polarized Retroreflective and Diffuse Models Suffix E, R, L, D and DL
92
More information online at bannerengineering.com
M18 Polarized Retroreflective and Fixed-field Models Suffix LP and FF
Page 29
S18/M18 Series Compact Sensors
Models
Sensing Mode/LED*
Download PDF
Range
S186E Emitter S186EQ Emitter
Cable**
Output Type
2m 4-Pin Euro QD, 2m 4-Pin Euro QD
NPN
S18SP6R S18SP6RQ
2m 4-Pin Euro QD
PNP
S18SN6L S18SN6LQ
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
S18SN6R S18SN6RQ
PHOTOELECTRICS
S18, 10-30V dc
20 m
Excess Gain
Beam Pattern
EGCO-16 (p. 428)
BPO-16 (p. 450)
EGCR-21 (p. 432)
BPR-20 (p. 454)
EGCR-22 (p. 432)
BPR-21 (p. 454)
EGCF-6 (p. 441), Data Sheet
OPPOSED
2m S18SP6L S18SP6LQ S18SN6LP S18SN6LPQ S18SP6LP S18SP6LPQ
RETRO
P
2m
†
POLAR RETRO
S18SN6FF25 S18SN6FF25Q
0 - 25 mm Cutoff
S18SP6FF25 S18SP6FF25Q S18SN6FF50 S18SN6FF50Q S18SP6FF50 S18SP6FF50Q
†
0 - 50 mm Cutoff FIXED-FIELD
S18SN6FF100 S18SN6FF100Q
0 - 100 mm Cutoff
S18SP6FF100 S18SP6FF100Q S18SN6D S18SN6DQ
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
100 mm S18SP6D S18SP6DQ S18SN6DL S18SN6DLQ
DIFFUSE
300 mm S18SP6DL S18SP6DLQ
116159
EGCF-7 (p. 441), EGCF-8 (p. 441), EGCD-25 (p. 435)
BPD-24 (p. 457)
EGCD-26 (p. 435)
BPD-25 (p. 457)
Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18SP6D W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
More information online at bannerengineering.com
93
Page 30
S18/M18 Series Compact Sensors PHOTOELECTRICS
M18, 10-30V dc Models
Sensing Mode/LED*
Download PDF
Range
Cable**
Output Type
2m 4-Pin Euro QD
–
2m 4-Pin Euro QD
NPN
M18SP6R M18SP6RQ
2m 4-Pin Euro QD
PNP
M18SN6L M18SN6LQ
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
M186E Emitter M186EQ Emitter M18SN6R M18SN6RQ
20 m
Excess Gain
Beam Pattern
EGCO-17 (p. 429)
BPO-17 (p.451)
EGCR-23 (p. 432)
BPR-22 (p. 454)
EGCR-24 (p. 432)
BPR-23 (p. 454)
EGCF-9 (p. 441), Data Sheet
OPPOSED
2m M18SP6L M18SP6LQ M18SN6LP M18SN6LPQ M18SP6LP M18SP6LPQ
RETRO
P
2m
†
POLAR RETRO
M18SN6FF25 M18SN6FF25Q
0 - 25 mm Cutoff
M18SP6FF25 M18SP6FF25Q M18SN6FF50 M18SN6FF50Q M18SP6FF50 M18SP6FF50Q
†
0 - 50 mm Cutoff FIXED-FIELD
M18SN6FF100 M18SN6FF100Q
0 - 100 mm Cutoff
M18SP6FF100 M18SP6FF100Q M18SN6D M18SN6DQ
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
100 mm M18SP6D M18SP6DQ M18SN6DL M18SN6DLQ
DIFFUSE
300 mm M18SP6DL M18SP6DLQ
49201
EGCF-10 (p. 441), EGCF-11 (p. 441), EGCD-27 (p. 435)
BPD-26 (p. 457)
EGCD-28 (p. 435)
BPD-27 (p. 457)
Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, M18SN6D W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
94
More information online at bannerengineering.com
Page 31
S18/M18 Series Compact Sensors
Supply Voltage and Current
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Non-polarized Retroreflective: 25 mA Fixed-field: 35 mA Diffuse: 25 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
Output Rating
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA Off-state leakage current: less than 1 mA at 30V dc; On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time
Repeatability
Opposed: 375 microseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 750 microseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON steady: Light Operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Construction
M18 models: stainless steel housing S18 models: thermoplastic polyester housing Lenses are polycarbonate or acrylic; S18 and M18 models come with two jam nuts.
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
PHOTOELECTRICS
S18 and M18 DC Specifications
Relative humidity: 90% at 50° C (non-condensing)
Certifications (S18 models)
Hookup Diagrams
R
Emitters: DC03 (p. 476)
Excludes M18
NPN Models: DC07 (p. 477)
PNP Models: DC08 (p. 477)
More information online at bannerengineering.com
95
Page 32
S18/M18 Series Compact Sensors PHOTOELECTRICS
S18 AC Sensors 18 mm thermoplastic polyester threaded barrel sensor 85.3 mm
Dual LED indicators 20 to 250V ac (3-wire hookup)
86.3 mm
SPST solid-state switch output, maximum load 300 mA S18 Polarized Retroreflective and Fixed-field models Suffix LP and FF
ø 18.0 mm
S18 Opposed, Non-polarized Retroreflective and Diffuse models Suffix E, R, L and D
Detailed Dimensions
S18, 20-250V ac Models
Sensing Mode/LED*
Download PDF
Range
S183E Emitter S183EQ1 Emitter S18AW3R S18AW3RQ1 S18RW3R S18RW3RQ1
20 m OPPOSED
S18AW3L S18AW3LQ1
2m
S18RW3L S18RW3LQ1 S18AW3LP S18AW3LPQ1 S18RW3LP S18RW3LPQ1
RETRO
P
0 - 25 mm Cutoff
S18RW3FF25 S18RW3FF25Q1 S18AW3FF50 S18AW3FF50Q1
S18AW3FF100 S18AW3FF100Q1 S18RW3FF100 S18RW3FF100Q1
2m
†
POLAR RETRO
S18AW3FF25 S18AW3FF25Q1
S18RW3FF50 S18RW3FF50Q1
†
0 - 50 mm Cutoff FIXED-FIELD
0 - 100 mm Cutoff
Cable**
Output Type
2m 4-Pin Micro QD, 2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
Excess Gain
Beam Pattern
EGCO-16 (p. 428)
BPO-16 (p. 450)
EGCR-21 (p. 432)
BPR-20 (p. 454)
EGCR-22 (p. 432)
BPR-21 (p. 454)
Data Sheet
116160
EGCF-6 (p. 441), EGCF-7 (p. 441), EGCF-8 (p. 441), Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18AW3LP W/30). A model with a QD requires a mating cable (see page 386). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
96
More information online at bannerengineering.com
Page 33
S18/M18 Series Compact Sensors
Models
Sensing Mode/LED*
S18AW3D S18AW3DQ1 S18RW3D S18RW3DQ1 S18AW3DL S18AW3DLQ1
DIFFUSE
S18RW3DL S18RW3DLQ1
Download PDF
Cable**
Output Type
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
Range
100 mm
300 mm
PHOTOELECTRICS
S18, 20-250V ac (cont’d) Excess Gain
Beam Pattern
EGCD-25 (p. 435)
BPD-24 (p. 457)
Data Sheet
116160 EGCD-26 (p. 435)
BPD-25 (p. 457)
Infrared LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18AW3D W/30). A model with a QD requires a mating cable (see page 386).
S18 AC Specifications Supply Voltage and Current
20 to 250V ac (50/60 Hz). Average current 20 mA. Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; Light Operate (LO) or Dark Operate (DO), depending on model. Light operate: Output conducts when the sensor sees its own (or the emitter’s) modulated light Dark operate: Output conducts when sensor sees dark
Output Rating
300 mA max. (continuous) Fixed-field models: derate 5 mA/° C above +50° C; Inrush capability: 1 amp for 20 milliseconds, non-repetitive Off-state leakage current: less than 100 mA On-state voltage drop: 3V at 300 mA ac; 2V at 15 mA ac
Output Protection Circuitry
Protected against false pulse on power-up
Output Response Time
Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 16 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up
Repeatability
Opposed Mode: 2 milliseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 4 milliseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1-1.5x) in light condition
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; two jam nuts included.
Environmental Rating
S18 models: Leakproof design rated NEMA 6P, DIN 40050 (IP69K) M18 models: Rated NEMA 6P (IP67)
Connections
2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. See page 386.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Certifications
S18 & M18 models
Relative humidity: 90% at 50° C (non-condensing)
S18 models only
S18 models only R
Hookup Diagrams
Cabled Emitters: AC03 (p. 484) QD Emitters: AC07 (p. 485)
Other Cabled Models: AC05 (p. 485) Other QD Models: AC06 (p. 485)
More information online at bannerengineering.com
97
Page 34
T18 Series Compact Sensors PHOTOELECTRICS
T18 18 mm Threaded Right-Angle Sensors • Features EZ-BEAM® technology, with specially designed optics and electronics for reliable sensing without adjustments on most models • T-style plastic housing with 18 mm threaded lens mount • Available in opposed, retroreflective, diffuse and fixed-field modes • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments • Uses innovative dual-indicator system to take the guesswork out of monitoring sensor performance • Includes advanced diagnostics to warn of marginal sensing conditions or output overload (dc models) OPPOSED
RETRO
DC Models . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 99 AC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
P POLAR RETRO
T18 DC Sensors DIFFUSE
Dual-LED multi-function indicators
30.0 mm
Detailed Dimensions
Popular 18 mm threaded lens mount FIXED-FIELD
BRACKETS
PAGE 350 QD CABLES
4-Pin Euro + 4-Pin Micro
10 to 30V dc with NPN or PNP outputs 2 m or 9 m attached cable, or Euro-style quick-disconnect
41.5 mm
PAGE 380 & 386 REFLECTORS
PAGE 391
ø 30.0 mm
APERTURES
PAGE 406
T18 DC Sensors (all models)
98
More information online at bannerengineering.com
Page 35
T18 Series Compact Sensors
Models
Sensing Mode/LED*
Download PDF
Range
T186E Emitter T186EQ Emitter T18SN6R T18SN6RQ T18SP6R T18SP6RQ
20 m OPPOSED
T18SN6L T18SN6LQ
2m
T18SP6L T18SP6LQ T18SN6LP T18SN6LPQ T18SP6LP T18SP6LPQ
2m
0 - 25 mm Cutoff
T18SP6FF25 T18SP6FF25Q T18SN6FF50 T18SN6FF50Q
0 - 50 mm Cutoff FIXED-FIELD
T18SN6FF100 T18SN6FF100Q
0 - 100 mm Cutoff
T18SP6FF100 T18SP6FF100Q T18SN6D T18SN6DQ T18SP6D T18SP6DQ
†
POLAR RETRO
T18SN6FF25 T18SN6FF25Q
T18SP6FF50 T18SP6FF50Q
†
RETRO
P
500 mm DIFFUSE
PHOTOELECTRICS
T18, 10-30V dc Cable**
Output Type
2m 4-Pin Euro QD
–
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
2m 4-Pin Euro QD
NPN
2m 4-Pin Euro QD
PNP
Excess Gain
Beam Pattern
EGCO-18 (p. 429)
BPO-18 (p. 451)
EGCR-25 (p. 432)
BPR-24 (p. 454)
EGCR-26 (p. 432)
BPR-25 (p. 454)
EGCF-12 (p. 441), EGCF-13 (p. 441), EGCF-14 (p. 441), EGCD-29 (p. 435)
BPD-28 (p. 457)
Data Sheet
116163
Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, T18SN6L W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
More information online at bannerengineering.com
99
Page 36
T18 Series Compact Sensors PHOTOELECTRICS
T18 DC Specifications Supply Voltage and Current
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Non-polarized Retroreflective: 25 mA Diffuse: 25 mA Fixed-field: 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
Output Rating
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA; Off-state leakage current: less than 1 mA at 30V dc; On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time
Adjustments
T18 Series infrared non-polarized retroreflective and diffuse mode models (only) have a single-turn rear-panel SENSITIVITY control for adjustment of system gain (turn clockwise to increase)
Repeatability
Opposed: 375 microseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 750 microseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON steady: Light Operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Relative humidity: 90% at 50° C (non-condensing)
Certifications R
Hookup Diagrams
100
Emitters: DC03 (p. 476)
NPN Models: DC07 (p. 477)
More information online at bannerengineering.com
PNP Models: DC08 (p. 477)