Page 28

S18/M18 Series Compact Sensors PHOTOELECTRICS

S18 and M18 18 mm ThreadedBarrel Sensors • Features EZ-BEAM® technology, with specially designed optics and electronics for reliable sensing without adjustments • Available in plastic threaded barrel sensor (S18) and stainless steel threaded barrel sensor (M18) • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments (S18) • Uses innovative dual-indicator system to take the guesswork out of monitoring sensor performance • Available in models for ac or dc power • Includes advanced diagnostics to warn of marginal sensing conditions or output overload (dc models) • Meets rigorous IP69K standards for use in 1200 psi washdowns (S18) OPPOSED

RETRO

S18 DC Models. . . . . . . . . . . . . . . . . . . . . . . .Page 93 M18 DC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 S18 AC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

P POLAR RETRO

S18 and M18 DC Sensors DIFFUSE

FIXED-FIELD

BRACKETS

PAGE 350 QD CABLES

Advanced self-diagnostics with separate alarm output; dual-LED multi-function indicators

S18 Opposed, Non-polarized Retroreflective and Diffuse Models Suffix E, R, L and D 59.2 mm

Popular 18 mm threaded barrel

65.0 mm

ø 18.0 mm

10 to 30V dc with NPN or PNP outputs

S18 Polarized Retroreflective and Fixed-field Models Suffix LP and FF

4-Pin Euro + 4-Pin Micro

PAGE 380 & 386 REFLECTORS

2 m or 9 m integral cable, or Euro-style quick-disconnect fitting

PAGE 391

ø 18.0 mm

APERTURES

PAGE 406

Detailed Dimensions

65.0 mm

59.2 mm

M18 Opposed, Non-polarized Retroreflective and Diffuse Models Suffix E, R, L, D and DL

92

More information online at bannerengineering.com

M18 Polarized Retroreflective and Fixed-field Models Suffix LP and FF

Page 29

S18/M18 Series Compact Sensors

Models

Sensing Mode/LED*

Download PDF

Range

S186E Emitter S186EQ Emitter

Cable**

Output Type

2m 4-Pin Euro QD, 2m 4-Pin Euro QD

NPN

S18SP6R S18SP6RQ

2m 4-Pin Euro QD

PNP

S18SN6L S18SN6LQ

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

S18SN6R S18SN6RQ

PHOTOELECTRICS

S18, 10-30V dc

20 m

Excess Gain

Beam Pattern

EGCO-16 (p. 428)

BPO-16 (p. 450)

EGCR-21 (p. 432)

BPR-20 (p. 454)

EGCR-22 (p. 432)

BPR-21 (p. 454)

EGCF-6 (p. 441), Data Sheet

OPPOSED

2m S18SP6L S18SP6LQ S18SN6LP S18SN6LPQ S18SP6LP S18SP6LPQ

RETRO

P

2m

†

POLAR RETRO

S18SN6FF25 S18SN6FF25Q

0 - 25 mm Cutoff

S18SP6FF25 S18SP6FF25Q S18SN6FF50 S18SN6FF50Q S18SP6FF50 S18SP6FF50Q

†

0 - 50 mm Cutoff FIXED-FIELD

S18SN6FF100 S18SN6FF100Q

0 - 100 mm Cutoff

S18SP6FF100 S18SP6FF100Q S18SN6D S18SN6DQ

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

100 mm S18SP6D S18SP6DQ S18SN6DL S18SN6DLQ

DIFFUSE

300 mm S18SP6DL S18SP6DLQ

116159

EGCF-7 (p. 441), EGCF-8 (p. 441), EGCD-25 (p. 435)

BPD-24 (p. 457)

EGCD-26 (p. 435)

BPD-25 (p. 457)

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18SP6D W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

More information online at bannerengineering.com

93

Page 30

S18/M18 Series Compact Sensors PHOTOELECTRICS

M18, 10-30V dc Models

Sensing Mode/LED*

Download PDF

Range

Cable**

Output Type

2m 4-Pin Euro QD

–

2m 4-Pin Euro QD

NPN

M18SP6R M18SP6RQ

2m 4-Pin Euro QD

PNP

M18SN6L M18SN6LQ

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

M186E Emitter M186EQ Emitter M18SN6R M18SN6RQ

20 m

Excess Gain

Beam Pattern

EGCO-17 (p. 429)

BPO-17 (p.451)

EGCR-23 (p. 432)

BPR-22 (p. 454)

EGCR-24 (p. 432)

BPR-23 (p. 454)

EGCF-9 (p. 441), Data Sheet

OPPOSED

2m M18SP6L M18SP6LQ M18SN6LP M18SN6LPQ M18SP6LP M18SP6LPQ

RETRO

P

2m

†

POLAR RETRO

M18SN6FF25 M18SN6FF25Q

0 - 25 mm Cutoff

M18SP6FF25 M18SP6FF25Q M18SN6FF50 M18SN6FF50Q M18SP6FF50 M18SP6FF50Q

†

0 - 50 mm Cutoff FIXED-FIELD

M18SN6FF100 M18SN6FF100Q

0 - 100 mm Cutoff

M18SP6FF100 M18SP6FF100Q M18SN6D M18SN6DQ

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

100 mm M18SP6D M18SP6DQ M18SN6DL M18SN6DLQ

DIFFUSE

300 mm M18SP6DL M18SP6DLQ

49201

EGCF-10 (p. 441), EGCF-11 (p. 441), EGCD-27 (p. 435)

BPD-26 (p. 457)

EGCD-28 (p. 435)

BPD-27 (p. 457)

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, M18SN6D W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

94

More information online at bannerengineering.com

Page 31

S18/M18 Series Compact Sensors

Supply Voltage and Current

10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Non-polarized Retroreflective: 25 mA Fixed-field: 35 mA Diffuse: 25 mA

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.

Output Rating

150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA Off-state leakage current: less than 1 mA at 30V dc; On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short circuit of outputs

Output Response Time

Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time

Repeatability

Opposed: 375 microseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 750 microseconds. Repeatability and response are independent of signal strength.

Indicators

Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON steady: Light Operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized

Construction

M18 models: stainless steel housing S18 models: thermoplastic polyester housing Lenses are polycarbonate or acrylic; S18 and M18 models come with two jam nuts.

Environmental Rating

Leakproof design rated NEMA 6P, DIN 40050 (IP69K)

Connections

2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.

Operating Conditions

Temperature: -40° to +70° C

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)

PHOTOELECTRICS

S18 and M18 DC Specifications

Relative humidity: 90% at 50° C (non-condensing)

Certifications (S18 models)

Hookup Diagrams

R

Emitters: DC03 (p. 476)

Excludes M18

NPN Models: DC07 (p. 477)

PNP Models: DC08 (p. 477)

More information online at bannerengineering.com

95

Page 32

S18/M18 Series Compact Sensors PHOTOELECTRICS

S18 AC Sensors 18 mm thermoplastic polyester threaded barrel sensor 85.3 mm

Dual LED indicators 20 to 250V ac (3-wire hookup)

86.3 mm

SPST solid-state switch output, maximum load 300 mA S18 Polarized Retroreflective and Fixed-field models Suffix LP and FF

ø 18.0 mm

S18 Opposed, Non-polarized Retroreflective and Diffuse models Suffix E, R, L and D

Detailed Dimensions

S18, 20-250V ac Models

Sensing Mode/LED*

Download PDF

Range

S183E Emitter S183EQ1 Emitter S18AW3R S18AW3RQ1 S18RW3R S18RW3RQ1

20 m OPPOSED

S18AW3L S18AW3LQ1

2m

S18RW3L S18RW3LQ1 S18AW3LP S18AW3LPQ1 S18RW3LP S18RW3LPQ1

RETRO

P

0 - 25 mm Cutoff

S18RW3FF25 S18RW3FF25Q1 S18AW3FF50 S18AW3FF50Q1

S18AW3FF100 S18AW3FF100Q1 S18RW3FF100 S18RW3FF100Q1

2m

†

POLAR RETRO

S18AW3FF25 S18AW3FF25Q1

S18RW3FF50 S18RW3FF50Q1

†

0 - 50 mm Cutoff FIXED-FIELD

0 - 100 mm Cutoff

Cable**

Output Type

2m 4-Pin Micro QD, 2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

Excess Gain

Beam Pattern

EGCO-16 (p. 428)

BPO-16 (p. 450)

EGCR-21 (p. 432)

BPR-20 (p. 454)

EGCR-22 (p. 432)

BPR-21 (p. 454)

Data Sheet

116160

EGCF-6 (p. 441), EGCF-7 (p. 441), EGCF-8 (p. 441), Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18AW3LP W/30). A model with a QD requires a mating cable (see page 386). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

96

More information online at bannerengineering.com

Page 33

S18/M18 Series Compact Sensors

Models

Sensing Mode/LED*

S18AW3D S18AW3DQ1 S18RW3D S18RW3DQ1 S18AW3DL S18AW3DLQ1

DIFFUSE

S18RW3DL S18RW3DLQ1

Download PDF

Cable**

Output Type

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

2m 4-Pin Micro QD

LO

2m 4-Pin Micro QD

DO

Range

100 mm

300 mm

PHOTOELECTRICS

S18, 20-250V ac (cont’d) Excess Gain

Beam Pattern

EGCD-25 (p. 435)

BPD-24 (p. 457)

Data Sheet

116160 EGCD-26 (p. 435)

BPD-25 (p. 457)

Infrared LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, S18AW3D W/30). A model with a QD requires a mating cable (see page 386).

S18 AC Specifications Supply Voltage and Current

20 to 250V ac (50/60 Hz). Average current 20 mA. Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac

Supply Protection Circuitry

Protected against transient voltages

Output Configuration

SPST solid-state ac switch; three-wire hookup; Light Operate (LO) or Dark Operate (DO), depending on model. Light operate: Output conducts when the sensor sees its own (or the emitter’s) modulated light Dark operate: Output conducts when sensor sees dark

Output Rating

300 mA max. (continuous) Fixed-field models: derate 5 mA/° C above +50° C; Inrush capability: 1 amp for 20 milliseconds, non-repetitive Off-state leakage current: less than 100 mA On-state voltage drop: 3V at 300 mA ac; 2V at 15 mA ac

Output Protection Circuitry

Protected against false pulse on power-up

Output Response Time

Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 16 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up

Repeatability

Opposed Mode: 2 milliseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 4 milliseconds. Repeatability and response are independent of signal strength.

Indicators

Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1-1.5x) in light condition

Construction

Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; two jam nuts included.

Environmental Rating

S18 models: Leakproof design rated NEMA 6P, DIN 40050 (IP69K) M18 models: Rated NEMA 6P (IP67)

Connections

2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. See page 386.

Operating Conditions

Temperature: -40° to +70° C

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)

Certifications

S18 & M18 models

Relative humidity: 90% at 50° C (non-condensing)

S18 models only

S18 models only R

Hookup Diagrams

Cabled Emitters: AC03 (p. 484) QD Emitters: AC07 (p. 485)

Other Cabled Models: AC05 (p. 485) Other QD Models: AC06 (p. 485)

More information online at bannerengineering.com

97

Page 34

T18 Series Compact Sensors PHOTOELECTRICS

T18 18 mm Threaded Right-Angle Sensors • Features EZ-BEAM® technology, with specially designed optics and electronics for reliable sensing without adjustments on most models • T-style plastic housing with 18 mm threaded lens mount • Available in opposed, retroreflective, diffuse and fixed-field modes • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments • Uses innovative dual-indicator system to take the guesswork out of monitoring sensor performance • Includes advanced diagnostics to warn of marginal sensing conditions or output overload (dc models) OPPOSED

RETRO

DC Models . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 99 AC Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

P POLAR RETRO

T18 DC Sensors DIFFUSE

Dual-LED multi-function indicators

30.0 mm

Detailed Dimensions

Popular 18 mm threaded lens mount FIXED-FIELD

BRACKETS

PAGE 350 QD CABLES

4-Pin Euro + 4-Pin Micro

10 to 30V dc with NPN or PNP outputs 2 m or 9 m attached cable, or Euro-style quick-disconnect

41.5 mm

PAGE 380 & 386 REFLECTORS

PAGE 391

ø 30.0 mm

APERTURES

PAGE 406

T18 DC Sensors (all models)

98

More information online at bannerengineering.com

Page 35

T18 Series Compact Sensors

Models

Sensing Mode/LED*

Download PDF

Range

T186E Emitter T186EQ Emitter T18SN6R T18SN6RQ T18SP6R T18SP6RQ

20 m OPPOSED

T18SN6L T18SN6LQ

2m

T18SP6L T18SP6LQ T18SN6LP T18SN6LPQ T18SP6LP T18SP6LPQ

2m

0 - 25 mm Cutoff

T18SP6FF25 T18SP6FF25Q T18SN6FF50 T18SN6FF50Q

0 - 50 mm Cutoff FIXED-FIELD

T18SN6FF100 T18SN6FF100Q

0 - 100 mm Cutoff

T18SP6FF100 T18SP6FF100Q T18SN6D T18SN6DQ T18SP6D T18SP6DQ

†

POLAR RETRO

T18SN6FF25 T18SN6FF25Q

T18SP6FF50 T18SP6FF50Q

†

RETRO

P

500 mm DIFFUSE

PHOTOELECTRICS

T18, 10-30V dc Cable**

Output Type

2m 4-Pin Euro QD

–

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

2m 4-Pin Euro QD

NPN

2m 4-Pin Euro QD

PNP

Excess Gain

Beam Pattern

EGCO-18 (p. 429)

BPO-18 (p. 451)

EGCR-25 (p. 432)

BPR-24 (p. 454)

EGCR-26 (p. 432)

BPR-25 (p. 454)

EGCF-12 (p. 441), EGCF-13 (p. 441), EGCF-14 (p. 441), EGCD-29 (p. 435)

BPD-28 (p. 457)

Data Sheet

116163

Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, T18SN6L W/30). A model with a QD requires a mating cable (see page 380). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.

More information online at bannerengineering.com

99

Page 36

T18 Series Compact Sensors PHOTOELECTRICS

T18 DC Specifications Supply Voltage and Current

10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Non-polarized Retroreflective: 25 mA Diffuse: 25 mA Fixed-field: 35 mA

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.

Output Rating

150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA; Off-state leakage current: less than 1 mA at 30V dc; On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short circuit of outputs

Output Response Time

Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time

Adjustments

T18 Series infrared non-polarized retroreflective and diffuse mode models (only) have a single-turn rear-panel SENSITIVITY control for adjustment of system gain (turn clockwise to increase)

Repeatability

Opposed: 375 microseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and Diffuse: 750 microseconds. Repeatability and response are independent of signal strength.

Indicators

Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON steady: Light Operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized

Construction

Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included

Environmental Rating

Leakproof design rated NEMA 6P, DIN 40050 (IP69K)

Connections

2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.

Operating Conditions

Temperature: -40° to +70° C

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)

Relative humidity: 90% at 50° C (non-condensing)

Certifications R

Hookup Diagrams

100

Emitters: DC03 (p. 476)

NPN Models: DC07 (p. 477)

More information online at bannerengineering.com

PNP Models: DC08 (p. 477)