The text of a spec sheet · part 5 of 5
Compact Sensors (Photoelectrics), pages 37 to 42
Pages 37 to 42 of 42
The original document is the PDF (8.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Banner S18SN6D
Page 37
T18 Series Compact Sensors PHOTOELECTRICS
T18 AC Sensors 30.0 mm
Dual-LED multi-function indicators
Detailed Dimensions
Popular 18 mm threaded barrel 20 to 250V ac with solid-state outputs 2 m or 9 m attached cable, or Euro-style quick-disconnect
51.5 mm
ø 40.0 mm
T18 AC Sensors (all models)
T18, 20-250V ac Models
Sensing Mode/LED*
Download PDF
Range
T183E Emitter T183EQ1 Emitter T18AW3R T18AW3RQ1 T18RW3R T18RW3RQ1
20 m OPPOSED
T18AW3L T18AW3LQ1
2 m†
T18RW3L T18RW3LQ1 T18AW3LP T18AW3LPQ1 T18RW3LP T18RW3LPQ1
RETRO
P
2 m†
POLAR RETRO
T18AW3D T18AW3DQ1 T18RW3D T18RW3DQ1
300 mm DIFFUSE
Cable**
Output Type
2m 4-Pin Micro QD
–
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
Excess Gain
Beam Pattern
EGCO-18 (p. 429)
BPO-18 (p. 451)
EGCR-25 (p. 432)
BPR-24 (p. 454)
Data Sheet
116164
EGCR-26 (p. 432)
BPR-25 (p. 454)
EGCD-30 (p. 435)
BPD-29 (p. 457)
Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, T18AW3L W/30). A model with a QD requires a mating cable (see page 386). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
More information online at bannerengineering.com
101
Page 38
T18 Series Compact Sensors PHOTOELECTRICS
T18, 20-250V ac (cont’d) Models
Sensing Mode/LED*
T18AW3FF25 T18AW3FF25Q1
T18AW3FF50 T18AW3FF50Q1
0 - 50 mm Cutoff FIXED-FIELD
T18AW3FF100 T18AW3FF100Q1 T18RW3FF100 T18RW3FF100Q1
Cable**
Output Type
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
2m 4-Pin Micro QD
LO
2m 4-Pin Micro QD
DO
Range 0 - 25 mm Cutoff
T18RW3FF25 T18RW3FF25Q1
T18RW3FF50 T18RW3FF50Q1
Download PDF
0 - 100 mm Cutoff
Excess Gain
Beam Pattern
EGCF-12 (p. 441), EGCF-13 (p. 441), EGCF-14 (p. 441), Data Sheet
32994
Infrared LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, T18AW3FF25 W/30). A model with a QD requires a mating cable (see page 386).
T18 AC Specifications Supply Voltage and Current
20 to 250V ac (50/60 Hz). Average current 20 mA. Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; Light Operate (LO) or Dark Operate (DO), depending on model. Light operate: Output conducts when the sensor sees its own (or the emitter’s) modulated light Dark operate: Output conducts when sensor sees dark
Output Rating
300 mA max. (continuous) Fixed-field models: derate 5 mA/° C above +50° C; Inrush capability: 1 amp for 20 milliseconds, non-repetitive Off-state leakage current: less than 100 mA On-state voltage drop: 3V at 300 mA ac; 2V at 15 mA ac
Output Protection Circuitry
Protected against false pulse on power-up
Output Response Time
Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field & Diffuse: 16 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up
Repeatability
Opposed Mode: 2 ms; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 4 milliseconds Repeatability and response are independent of signal strength.
Adjustments
T18 Series infrared non-polarized retroreflective and diffuse mode models (only) have a single-turn rear-panel SENSITIVITY control for adjustment of system gain (turn clockwise to increase)
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1-1.5x) in light condition
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; T18 models come with one jam nut.
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. See page 386.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Relative humidity: 90% at 50° C (non-condensing)
Certifications R
Hookup Diagrams
102
Cabled Emitters: AC03 (p. 484) QD Emitters: AC07 (p. 485)
More information online at bannerengineering.com
Other cabled Models: AC05 (p. 485) Other QD Models: AC06 (p. 485)
Page 39
Q25 Series Compact Sensors PHOTOELECTRICS
Q25 Right-Angle Rectangular Sensors • Features EZ-BEAM® technology, with specially designed optics and electronics for reliable sensing without adjustments • Available in opposed, retroreflective or fixed-field modes in rectangular 25 mm plastic housing with 18 mm threaded mounting base • Completely epoxy-encapsulated for superior durability, even in harsh sensing environments • Uses an innovative dual-indicator system to take the guesswork out of monitoring sensor performance • Available in models for ac or dc power • Includes advanced diagnostics to warn of marginal sensing conditions or output overload (dc models)
OPPOSED
P
Q25 Sensors
POLAR RETRO
25.0 mm 30.0 mm
Yellow LED output indicator FIXED-FIELD
Detailed Dimensions
18 mm threaded mounting base 2 m or 9 m attached cable, or Euro-style quick disconnect
BRACKETS
PAGE 350 QD CABLES
4-Pin Euro + 4-Pin Micro
Green LED power indicator
31.0 mm 25.0 mm
PAGE 380 & 386 REFLECTORS
50.2 mm 50.2 mm PAGE 391
Q25 Fixed-field models Suffix FF
Q25 Opposed and Retroreflective models Suffix E, R and LP
More information online at bannerengineering.com
103
Page 40
Q25 Series Compact Sensors PHOTOELECTRICS
Q25, 10-30V dc Models Q256E Emitter Q256EQ Emitter Q25SN6R Q25SN6RQ Q25SP6R Q25SP6RQ Q25SN6LP Q25SN6LPQ Q25SP6LP Q25SP6LPQ Q25SN6FF25 Q25SN6FF25Q Q25SP6FF25 Q25SP6FF25Q Q25SN6FF50 Q25SN6FF50Q Q25SP6FF50 Q25SP6FF50Q Q25SN6FF100 Q25SN6FF100Q Q25SP6FF100 Q25SP6FF100Q
Sensing Mode/LED*
Download PDF
Range
20 m OPPOSED
P
2 m†
POLAR RETRO
0 - 25 mm Cutoff
0 - 50 mm Cutoff FIXED-FIELD
0 - 100 mm Cutoff
Cable** 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD 2m 4-Pin Euro QD
Output Type
Excess Gain
Beam Pattern
EGCO-19 (p. 429)
BPO-19 (p. 451)
EGCR-27 (p. 432)
BPR-26 (p. 454)
– NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP
116165 EGCF-15 (p. 441), EGCF-16 (p. 441), EGCF-17 (p. 442), Q25, 20-250V ac Models Q253E Emitter Q253EQ1 Emitter Q25AW3R Q25AW3RQ1 Q25RW3R Q25RW3RQ1 Q25AW3LP Q25AW3LPQ1 Q25RW3LP Q25RW3LPQ1 Q25AW3FF25 Q25AW3FF25Q1 Q25RW3FF25 Q25RW3FF25Q1 Q25AW3FF50 Q25AW3FF50Q1 Q25RW3FF50 Q25RW3FF50Q1 Q25AW3FF100 Q25AW3FF100Q1 Q25RW3FF100 Q25RW3FF100Q1
Sensing Mode/LED*
Download PDF
Range
20 m OPPOSED
P
Data Sheet
2 m†
POLAR RETRO
0 - 25 mm Cutoff
0 - 50 mm Cutoff FIXED-FIELD
0 - 100 mm Cutoff
Cable** 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD 2m 4-Pin Micro QD
Output Type
Excess Gain
Beam Pattern
EGCO-19 (p. 429)
BPO-19 (p. 451)
EGCR-27 (p. 432)
BPR-26 (p. 454)
EGCF-15 (p. 441), EGCF-16 (p. 441), EGCF-17 (p. 442), Data Sheet
– LO DO LO DO LO DO LO DO LO DO
116166
Infrared LED Visible Red LED * ** For 9 m cable, add suffix W/30 to the 2 m model number (example, Q25AW3LP W/30). A model with a QD requires a mating cable (see pages 380 and 386). † Retroreflective range is specified using one model BRT-3 retroreflector. Actual sensing range may differ, depending on the efficiency and reflective area of the retroreflector used. See Accessories for more information.
104
More information online at bannerengineering.com
Page 41
Q25 Series Compact Sensors PHOTOELECTRICS
Q25 DC Specifications Supply Voltage and Current
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-field: 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model. The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
Output Rating
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA Off-state leakage current: less than 1 mA at 30V dc On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective and Fixed-field: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time
Repeatability
Opposed: 375 microseconds; Polarized Retroreflective and Fixed-field: 750 microseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON steady: Light Operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; come with one jam nut.
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Relative humidity: 90% at 50° C (non-condensing)
Certifications R
Hookup Diagrams
Emitters: DC03 (p. 476)
NPN Models: DC07 (p. 477)
PNP Models: DC08 (p. 477)
More information online at bannerengineering.com
105
Page 42
Q25 Series Compact Sensors PHOTOELECTRICS
Q25 AC Specifications Supply Voltage and Current
20 to 250V ac (50/60 Hz). Average current 20 mA. Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; Choose Light Operate (LO) or Dark Operate (DO), depending on model. Light operate: Output conducts when the sensor sees its own (or the emitter’s) modulated light Dark operate: Output conducts when sensor sees dark
Output Rating
300 mA max. (continuous) Fixed-field models: derate 5 mA/° C above +50° C; Inrush capability: 1 amp for 20 milliseconds, non-repetitive Off-state leakage current: less than 100 mA On-state voltage drop: 3V at 300 mA ac; 2V at 15 mA ac
Output Protection Circuitry
Protected against false pulse on power-up
Output Response Time
Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF Polarized Retroreflective and Fixed-field: 16 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up
Repeatability
Opposed Mode: 2 milliseconds; Polarized Retroreflective and Fixed-field: 4 milliseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1-1.5x) in light condition
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included.
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. See page 386.
Operating Conditions
Temperature: -40° to +70° C
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Relative humidity: 90% at 50° C (non-condensing)
Certifications R
Hookup Diagrams
106
Cabled Emitters: AC03 (p. 484) QD Emitters: AC07 (p. 485)
More information online at bannerengineering.com
Other Cabled Models: AC05 (p. 485) Other QD Models: AC06 (p. 485)