For the Beijer Electronics AB E200

Page 182

Report print-outs

13 Report print-outs The chapter is not valid for E50. This section describes how to make a report print-out from the terminal. For production follow-up it is simple to create different types of reports such as daily reports and event reports. The illustration below shows the principle for generating a daily report.

171

Page 183

Report print-outs

13.1 Connection to a printer Printer

Terminal RS-422

RS-232

The printer should have a serial interface and be equipped with IBM character set (850). The settings for the printer are set under Peripherals in the Setup menu in the terminal. Refer to the printer manual for the correct configuration. Note! A printer with parallel interface can be connected if the expansioncard IFC PI is used.

13.2 Text block printouts The reports are created as Text blocks with static and dynamic text. The report has a maximum width of 150 characters. In the text block you enter a free text, e.g. table head and other static text which always will be printed. To get dynamic values from the process in the report you define dynamic objects, presenting the value for the signal the object is linked to. See the chapter Textbased presentation and maneuvering. Via time channels it is possible to decide when the report is to be printed.

172

Page 184

Report print-outs

13.3 Graphic block printout In E300, E600, E700 and E710 it is possible to print a graphic page to a Epson FX-80 or HP PCL5 compatible printer. Graphic blocks can only be printed when it’s displayed (screen dump). Only black and white graphics are supported.

13.4 Defining the print-out The Print signal parameter in the block header gives the signal which when set activates the print-out. A Completion signal is also given here which is set by the terminal when the print-out is completed. This signal is instead set to zero if Reset is marked.

173

Page 185

Report print-outs

13.5 Printer settings The settings for the printer must be made under Peripherals in the Setup menu. Under Peripherals you select Printer and then press Edit.... For more detailed information concerning the printer refer to the manual for the printer used. If you select Standard text the printer must support IBM extended ASCII character set. If graphic blocks are printed the printer must support Epson FX-80 or HP PCL graphics. If you use the expansion card IFC PI it is possible to print on a HP writer.

Parameter

174

Description

Printer type

Select printer, none or installed printer, e.g. HP PCL5.

Page length

The number of lines to be printed out before form feed. Form feed never takes place if the page length is set to 0.

Paper type

Select paper type according to installed printer.

Graphic orientation

States if the graphic printout should be portrait or landscape if a PCL5 compatible printer is used.

Text orientation

States if the report printout should be portrait or landscape if a PCL5 compatible printer is used.

Printer disable signal

State a digital signal which when set cloeses the printout. The port where the printer is connected will then be free to use for e.g. transparent mode. Not valid if IFC PI is used.

Page 186

Report print-outs Parameter

Description

New line character

End of line character; CR/LF, CR, LF or none.

Handshake

States whether handshaking between the printer and terminal will take place with XON/XOFF or CTS/RTS.

Screen dump

Possibility to printout the screen, normal or inverted.

13.6 Setting a communication port Settings for the communication port must be made under Peripherals. Under Peripherals you select RS-232 or RS-422 and then press the Edit... button. See the manual for the printer concerned for the correct setting.

Parameter

Description

Baudrate

Select the transfer rate for communication. Must be the same as the external unit.

Parity

Select parity. Must be the same as the external unit.

Databits

Select number of data bits. Must be the same as the external unit.

Stopbits

Select number of stop bits. Must be the same as the external unit.

175

Page 187

Report print-outs

13.7 Control codes to printer Not valid for E50, E100 and E200. It is possible to type control codes to a printer in textblocks. You type %% followed by a number between 1 and 31, which are control codes to printer. For example %%12 which is paper feed, for further description of control codes we refer to the manual for the printer used. One command must be followed by a blank character. If you have set a transverse (paper) feed must this be at the end of the line. The characters %% must not occur in the text. It is possible to have more than one command/control code on one line.

176