The text of a manual · part 32 of 41
E-terminals Programming manual: 18 Network communication, pages 248 to 253
Pages 248 to 253 of 335, from E-terminals Programming manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Beijer Electronics AB E200
Page 248
Network communication Recipients
A predefined list of max 16 receivers. A receiver addres can be max 60 characters long.
Alarm via email In the same way as alarm can be printed they can be sent as email. The whole alarmlist will be sent if you send block 990 (see Block Mail Report).
Mail to address
Enter the receiver of the message. Select up to eight receivers from the predefined list in the SMTP Client Service dialog. Info block
If you state an information block and it is a textblock it will be included in the message. For more information see “Alarm handling”.
Report via email In the same way as textblock can be printed they can be sent as email. Note! Only textblock can be sent. Only the alarm block,990, of the system block are sent as email. Trend and recipe files are sent as attach files.
237
Page 249
Network communication
Block name
If you enter a name of a textblock it will be sent as a message/subject. Send mail signal:
The message is sent when stated signal is set. Mail completion signal:
A digital signal which is activated by the terminal when the message is sent. Normally the signal is set. If you mark the function Reset the signal will be reset when the message is sent. Mail to address:
Enter the email address to the receiver. Select up to eight receivers from the list shown when you click on the ...-button. The list of email addresses are defined in the dialog SMTP Client Service under Network Services in the Setup menu. Attach file:
Enter a name of a trend or recipe file to be attach with the message. If there are a trend file and a recipe file with the same name the trend file will be attach. The file name may not contain national characters. 238
Page 250
Network communication
Email via system block By making a jump to the system block Mail, 993, you can write and send a mail during run-time. E700
E710
Send E-mail to
Enter the receiver. You can enter the address or select from the global list shown when you click the button LIST on a terminal with keyboard or on the MAIL button on a terminal with touch screen. Subject
Enter the subject for the message. Max 50 characters. The text in the message can be max 10 rows a 50 characters.
239
Page 251
Network communication
Terminal Controller Used for RUN/TRANSFER switching via TCP/IP. Press Edit and enter the number of the port to be stated to enable transfer. The port number doesn’t normally need to be changed. Mark Request authentication if username and password must be stated before transfer.
WWW Server With this function you can configure the WWW-server in the terminal. A Webb server is a program that, using the client/server model and the World Wide Webb’s Hypertext Transfer Protocol (HTTP), serves the files form Web pages to Web users (whose computers contain HTTP clients that forward their request). See the chapter Network functions in the terminal.
Port number
Default is 80 and should not be changed. Account name
By selecting an account name you protect the HTML pages with password. Accounts are defefined under Network.. Accounts in the Setup menu.
240
Page 252
Network communication
Account name
Shows the Account name entered in previous dialog. Password
Enter a password. All HTML pages are protected with this Account name/password. To protect a singel page with another Account name/Password you enter the following in the head of the HTML page. <HTML> <HEAD> <META name=”superuser” content=”12345”* </HEAD> Here you place the rest of the HTML code. </HTML> * “superuser” is user name and “12345” is password. Note! The code above must be found in the header. The parameters Name and Content must correspond to an Account name and a Password.
241
Page 253
Network communication
18.5 Network accounts Accounts define who may connect to services available at terminals requiring logon. The function is used to create access control. You create a name and password for different users who will have access to different network services.
242