Page 248

Network communication Recipients

A predefined list of max 16 receivers. A receiver addres can be max 60 characters long.

Alarm via email In the same way as alarm can be printed they can be sent as email. The whole alarmlist will be sent if you send block 990 (see Block Mail Report).

Mail to address

Enter the receiver of the message. Select up to eight receivers from the predefined list in the SMTP Client Service dialog. Info block

If you state an information block and it is a textblock it will be included in the message. For more information see “Alarm handling”.

Report via email In the same way as textblock can be printed they can be sent as email. Note! Only textblock can be sent. Only the alarm block,990, of the system block are sent as email. Trend and recipe files are sent as attach files.

237

Page 249

Network communication

Block name

If you enter a name of a textblock it will be sent as a message/subject. Send mail signal:

The message is sent when stated signal is set. Mail completion signal:

A digital signal which is activated by the terminal when the message is sent. Normally the signal is set. If you mark the function Reset the signal will be reset when the message is sent. Mail to address:

Enter the email address to the receiver. Select up to eight receivers from the list shown when you click on the ...-button. The list of email addresses are defined in the dialog SMTP Client Service under Network Services in the Setup menu. Attach file:

Enter a name of a trend or recipe file to be attach with the message. If there are a trend file and a recipe file with the same name the trend file will be attach. The file name may not contain national characters. 238

Page 250

Network communication

Email via system block By making a jump to the system block Mail, 993, you can write and send a mail during run-time. E700

E710

Send E-mail to

Enter the receiver. You can enter the address or select from the global list shown when you click the button LIST on a terminal with keyboard or on the MAIL button on a terminal with touch screen. Subject

Enter the subject for the message. Max 50 characters. The text in the message can be max 10 rows a 50 characters.

239

Page 251

Network communication

Terminal Controller Used for RUN/TRANSFER switching via TCP/IP. Press Edit and enter the number of the port to be stated to enable transfer. The port number doesn’t normally need to be changed. Mark Request authentication if username and password must be stated before transfer.

WWW Server With this function you can configure the WWW-server in the terminal. A Webb server is a program that, using the client/server model and the World Wide Webb’s Hypertext Transfer Protocol (HTTP), serves the files form Web pages to Web users (whose computers contain HTTP clients that forward their request). See the chapter Network functions in the terminal.

Port number

Default is 80 and should not be changed. Account name

By selecting an account name you protect the HTML pages with password. Accounts are defefined under Network.. Accounts in the Setup menu.

240

Page 252

Network communication

Account name

Shows the Account name entered in previous dialog. Password

Enter a password. All HTML pages are protected with this Account name/password. To protect a singel page with another Account name/Password you enter the following in the head of the HTML page. <HTML> <HEAD> <META name=”superuser” content=”12345”* </HEAD> Here you place the rest of the HTML code. </HTML> * “superuser” is user name and “12345” is password. Note! The code above must be found in the header. The parameters Name and Content must correspond to an Account name and a Password.

241

Page 253

Network communication

18.5 Network accounts Accounts define who may connect to services available at terminals requiring logon. The function is used to create access control. You create a name and password for different users who will have access to different network services.

242