Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of NM Series Direct Coupled Actuator

Manual · Belimo

NM Series Direct Coupled Actuator

Manual17 pagesPDF 413 KB

Belimo technical documentation for NM Series direct coupled damper actuators: NM24 US, NM24-SR US, NM24-MFT US and NMQ24-MFT US.

What this file really is

The old site listed this file as a manual for the Belimo NM24-AV, NM24-PWM and Control Systems Intl NM24-PWM. Linked as the NM24-AV manual, it is the NM Series section of Belimo's damper actuator documentation and does not name the NM24-AV or NM24-PWM.

Download the PDF413 KB

Filed with · 3 models

Also filed with these models on the old site

Summary

What is in it

The NM Series section of Belimo's damper actuator technical documentation. It gives an overview of the series, then technical data, operation, wiring diagrams and typical specifications for the NM24 US on-off/floating point actuator, the NM24-SR US proportional actuator, and the NM24-MFT US and fast-acting NMQ24-MFT US Multi-Function Technology actuators (which accept PWM and other control inputs), followed by auxiliary switches, general wiring, installation instructions and start-up and checkout.

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Belimo catalog section for the NM Series direct coupled damper actuators: the NM24 US, NM24-SR US, NM24-MFT US and NMQ24-MFT US, with the SN1 and SN2 auxiliary switches. It does not name the NM24-AV or NM24-PWM. It gives technical data, wiring diagrams, mounting steps and a start-up and checkout procedure.

Read for this summary: pages 1 to 13 and 16 to 17 of 17.

Device type
Direct coupled, non-spring return damper actuators for HVAC dampers p. 3, 5, 7, 9
Torque
NM24 US, NM24-SR US, NM24-MFT US: min 70 in-lb (8 Nm); NMQ24-MFT US: min 35 in-lb (4 Nm) p. 3, 5, 7, 9
Power supply
NM24 US, NM24-SR US, NM24-MFT US: 24 VAC ± 20% 50/60 Hz or 24 VDC ± 10%; NMQ24-MFT US: ± 5% p. 3, 5, 7, 9
Control signal
NM24 US: on-off or floating point; NM24-SR US: 2 to 10 VDC or 4 to 20 mA; NM24-MFT US: 2 to 10 VDC by default p. 3, 5, 7
Running time
NM24 US: 75 to 150 sec; NM24-SR US: 150 seconds for 35 to 95°; NM24-MFT US: 150 seconds; NMQ24-MFT US: 5.0 seconds for 95° p. 3, 5, 7, 9
Feedback
NM24-SR US and NM24-MFT US: 2 to 10 VDC position feedback (U) p. 5, 7
Power consumption
NM24 US: 2 W running, 1 W holding; NM24-SR US and NM24-MFT US: 1.3 W, 0.5 W; NMQ24-MFT US: 9 W, 1.2 W p. 3, 5, 7, 9
Angle of rotation
0 to 95°, adjustable with mechanical stops p. 3, 5, 7, 9
Electrical connection
3 ft, 18 GA plenum rated cable with 1/2 in. conduit connector p. 3, 5, 7
Temperature
Ambient -4 to +122° F (-20 to +50° C); storage -40 to +176° F (-40 to +80° C) p. 5, 7, 9
Housing
NEMA 2; NM24-MFT US and NMQ24-MFT US: NEMA 2, IP54 p. 3, 5, 7, 9
Weight
1.8 lbs (0.8 kg) p. 7, 9
Accessories
AV 10-18 shaft extension, SN1/SN2 auxiliary switches, ZG-H2 operator handle, ZG-NMSA-1 shaft adaptor, ZG-R01 resistor, SGA24/SGF24 positioners p. 5, 7, 16
Auxiliary switches
SN1: 1 SPDT; SN2: 2 SPDT; 6 A (2.5 A) 250 VAC p. 11

What this manual walks you through

  • Quick mounting of the actuator on a damper shaft p. 12
  • Standard mounting with the 5° pre-load for tight damper close-off p. 13
  • Setting the adjustable end stops p. 13
  • Testing the installation without power using the manual override p. 13
  • Wiring on-off and tri-state control of the NM24 US p. 4
  • Wiring 2 to 10 VDC and 4 to 20 mA control of the NM24-SR US p. 6
  • Wiring override control to min, mid and max positions on the NM24-MFT US p. 8
  • Starting the NMQ24-MFT US adaptation after installation p. 9
  • Mounting the SN1 or SN2 auxiliary switch p. 11
  • Start-up and electrical checkout of the NM24-SR US and NM24-MFT US p. 17

Good to know

  • Mount the actuator indoors; outdoors it needs a protective enclosure. p. 13
  • The SN1 and SN2 switches do not fit NM actuators made before May 1994. p. 11
  • Controllers and actuators must have separate 24 VAC/VDC power sources. p. 17
  • With a 4-20 mA input up to 4 actuators may be wired in parallel; the 500Ω resistor causes a 2% signal shift. p. 8
  • PWM and floating point control inputs are not available on the NMQ24-MFT US. p. 10

Questions this manual answers

What minimum voltage does an NM24-SR US actuator need?

At least 19.2 VAC or 21.6 VDC, from a supply rated at or above the total power of the actuators. p. 17

How do I use a 4 to 20 mA signal with the NM24-SR US?

Add a 500Ω resistor, which converts the 4 to 20 mA signal to 2 to 10 VDC. p. 6

Why does my NM24-SR US actuator not follow the control signal?

Check that control signal positive goes to wire 3 and negative to wire 1; most control problems come from reversing these two wires. p. 17

How large a damper can an NM24 US drive?

Up to 18 sq ft, based on about 4 in-lb of torque per square foot of damper area. p. 3

How do I move the damper by hand on an NM24 actuator?

Press the half round black manual override button next to the cable entry to disengage the gear train; release it to re-engage. p. 13

The whole text · 2 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1710-17

The file

Revision and size

RevisionG20492
PublisherBelimo Aircontrols (USA), Inc.
Pages17
PDF413 KB
TextText from the PDF itself.

The first pages · 3 of 17

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 17
Page 2
Page 2of 17
Page 3
Page 3of 17