The text of a manual · part 3 of 6
Installing In-Sight 1000 Series Vision Sensors: Installing the In-Sight 1000, pages 15 to 24
Pages 15 to 24 of 46, from Installing In-Sight 1000 Series Vision Sensors
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cognex In-Sight 1000
Page 15
2 Installing the In-Sight 1000 In this section… 2.1
Connecting the In-Sight 1000.................................................................................7
2.2
Installing In-Sight PC Host Software ....................................................................13
2.3
Adding the In-Sight 1000 to a Network.................................................................14
2.4
Logging On to the In-Sight 1000 ..........................................................................19
2.5
Changing In-Sight 1000 Network Settings ...........................................................20
2.1 Connecting the In-Sight 1000 The In-Sight sensor has two RJ-45 connector ports opposite the lens mount, as shown in Figure 2-1: the Network port (left, labeled ENET) and the Breakout port (right, labeled 24VDC). The Network port provides the Ethernet connection for network communications. The Breakout port supplies connections for power, I/O, and serial communications.
Figure 2-1: In-Sight 1000 Network and Breakout Ports
2.1.1 Connecting the Network Cable If you are connecting to an Ethernet switch: 1
Plug one of the RJ-45 connectors on a CAT5 straight-pinned cable (yellow if supplied by Cognex) into the ENET port.
2
Plug the other end of the CAT5 straight-pinned cable into an available port on the switch.
7
Page 16
Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
If you are connecting directly to an In-Sight sensor or In-Sight PC Host: 1
Plug one of the RJ-45 connectors on a CAT5 crossover cable into the ENET port on the In-Sight 1000.
2
Plug the other end of the CAT5 crossover cable into the other system’s Ethernet port.
2.1.2 Connecting the Breakout Cable The In-Sight Breakout Cable (P/N 300-0340-15) included with every In-Sight sensor provides access to the In-Sight 1000 sensor’s power, serial communications, and I/O lines. The RJ-45 connector on this cable is “keyed” to the notch in the breakout port, and cannot be inadvertently plugged in to the network port. See Section 3.2.1: Breakout Port Pin Assignments on page 29 for the Breakout Cable’s wiring details. To connect the Breakout Cable to the In-Sight 1000:
8
1
Verify the 24VDC power supply being used is switched off.
2
Attach the Breakout Cable’s power (white-green wire) and ground (brown wire) to the corresponding terminals on the power supply.
3
Connect the wires for the acquisition trigger, discrete outputs, and serial communications to their corresponding terminals on remote devices.
4
Plug the RJ-45 connector into the In-Sight 1000 sensor’s breakout port (labeled 24VDC).
5
Restore power to the 24V supply. The green power LED will indicate that the 1000 is receiving power.
Page 17
Installing In-Sight™ 1000 Series Vision Sensors
Section 2: Installing the In-Sight 1000
2.1.3 Connecting the Breakout Module The optional In-Sight Breakout Module (P/N 800-5743) is more convenient than using the standard Breakout Cable to connect the In-Sight 1000 sensor’s power, serial communications, and I/O lines. For additional information on connecting a Breakout module, see Section 3.2.1: Breakout Port Pin Assignments on page 29 or the Breakout Module Installation and Reference manual (P/N 597-0008-xx).
Figure 2-2: Breakout Module Connections
9
Page 18
Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
To connect the Breakout Module to the In-Sight 1000:
10
1
Verify the 24VDC power supply being used is switched off.
2
Optionally, connect the power and ground wires for the acquisition trigger input and the discrete outputs into their corresponding terminals on the Breakout Module.
3
Optionally, connect the 9-pin male D-sub connector of an RS232 serial cable into the corresponding 9-pin female connector on the Breakout Module.
4
Plug the Breakout Module Cable’s 15-pin male D-sub connector into the corresponding female connector on the Breakout Module.
5
Plug the RJ-45 connector of the Breakout Module Cable (P/N 300-0341-15) into the In-Sight 1000 sensor’s breakout port. The cable’s connectors are “keyed” to the notch in the Breakout port.
6
Plug the wire leads from a 24VDC supply for the +24V power and ground into the 2-pin terminal plug on the Breakout Module. Alternatively, remove the terminal plug and insert the 2-pin terminal plug attached to the In-Sight power adapter into the keyed power adapter port on the Breakout Module (Figure 2-2).
7
Restore power to the 24V supply. The red power LED on the In-Sight 1000 and the orange +24V LED on the Breakout Module will indicate that the In-Sight 1000 and Breakout Module are receiving power.
Page 19
Installing In-Sight™ 1000 Series Vision Sensors
Section 2: Installing the In-Sight 1000
2.1.4 Connecting the I/O Expansion Module Like the Breakout Module, the optional I/O Expansion Module provides convenient access to the In-Sight 1000 sensor’s power, serial communications, and discrete I/O lines. In addition to the two discrete outputs, acquisition trigger, and serial transmit/receive that are standard on the 1000, the I/O Expansion module provides the following:
§ § §
8 discrete outputs 8 discrete inputs RS232 hardware handshaking
For additional information on connecting an In-Sight I/O Expansion module, see Section 3.2.1: Breakout Port Pin Assignments on page 29 or the In-Sight Expansion Module Installation and Reference manual (P/N 597-0013-xx).
Figure 2-3: I/O Expansion Module Connections
11
Page 20
Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
To connect an I/O Expansion Module to the In-Sight 1000: 1
Verify the 24VDC power supply being used is switched off.
2
Optionally, connect the power and ground wires for the acquisition trigger input, discrete outputs, and discrete inputs into their corresponding terminals on the Expansion Module.
NOTE
12
The outputs labeled HSOUT0 and HSOUT1 are high-speed outputs direct from the In-Sight 1000 and pass through the Expansion Module. The outputs labeled OUT0 through OUT7 are lower speed because their signals are processed by the Expansion Module processor before being sent to remote devices.
3
Optionally, connect the 9-pin male D-sub connector of an RS232 serial cable into the corresponding 9-pin female connector on the Expansion Module.
4
Plug the Expansion Module Cable’s 15-pin male D-sub connector into the corresponding female connector on the Expansion Module.
5
Plug the RJ-45 connector of the Expansion Module Cable (P/N 300-0341-15) into the In-Sight 1000 sensor’s breakout port. The cable’s connectors are “keyed” to the notch in the Breakout port.
6
Plug wire leads from a 24VDC supply for the +24V power and ground into the 2-pin terminal plug labeled “Power Input” on the Expansion Module. Alternatively, remove the terminal plug and insert the 2-pin terminal plug attached to the In-Sight power adapter into the keyed power adapter port on the Expansion Module ().
7
Restore power to the 24V supply. The green power LED on the 1000 and the +24V LED on the Expansion Module will indicate that the 1000 is receiving power.
Page 21
Installing In-Sight™ 1000 Series Vision Sensors
Section 2: Installing the In-Sight 1000
2.2 Installing In-Sight PC Host Software The In-Sight 1000 is configured, and its operation monitored, over an Ethernet network from an In-Sight 3000 or from a PC. To use an In-Sight 1000 networked to an In-Sight 3000 requires a control pad for input and a VGA monitor for display. An In-Sight 1000 accessed from a networked PC is configured using mouse and keyboard input. The following must be installed on the PC:
§
A Microsoft® Windows™ XP, 2000, NT 4.0 (with Service Pack 4 or later), Me, or 98SE operating system.
§ §
A network card that supports 10/100 Base-T Ethernet TCP/IP communications.
§
Internet Explorer 4.0 or higher to display the In-Sight Guide & Reference.
NOTE
In-Sight PC Host software version 2.30 or later (included on the CD-ROM shipped with your system).
In-Sight PC Host software can be used only on a local subnet that includes a networked In-Sight sensor.
To install In-Sight PC Host software on a Windows PC: 1
Shut down any applications running on your PC.
2
Insert the In-Sight installation CD-ROM into your PC’s CD-ROM drive. If the install program starts automatically, follow the setup dialogs as they appear on screen. If the install program does not start automatically:
3
Click the Start menu, click Run, and then click Browse.
4
In the browse window, select the PC’s CD-ROM drive, and then select the SETUP.EXE file.
5
Click Open, and then click OK to begin the installation. The default installation directory is C:\IN-SIGHT2.
6
When the installation program is complete, remove the CD from the CD-ROM drive.
13
Page 22
Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
7
Verify the In-Sight PC Host software installation by opening the Start menu, opening the Programs menu, opening the In-Sight program group, and then selecting In-Sight PC Host. The In-Sight PC Host window will appear, displaying the In-Sight spreadsheet.
8
Verify the In-Sight Guide & Reference installation by opening the Start menu, opening the Programs menu, opening the In-Sight program group, and then selecting In-Sight Help. If you are running Windows NT 4.0 and the In-Sight Guide and Reference does not open, verify you are using Internet Explorer version 4.0 or higher. If not, use Service Pack 4 to update your browser.
NOTE
Open the RELNOTES.DOC file for current information about In-Sight software, including new features, fixes, and known issues. Registered In-Sight PC Host users can download updated versions of In-Sight documentation at www.cognex.com/In-Sight/support/support.asp.
2.3 Adding the In-Sight 1000 to a Network The In-Sight 1000 is ready to be installed as a network host once it has power and is physically connected to the network. As previously described, there are many possible In-Sight network configurations. The specific procedure for adding an In-Sight 1000 to a network depends on whether or not a Dynamic Host Configuration Protocol (DHCP) server is available. The DHCP server automatically assigns the In-Sight 1000 sensor a network IP address and Subnet Mask. NOTE
14
When installing the In-Sight 1000 to an existing network, consult your network administrator to determine whether a DHCP server is available.
Page 23
Installing In-Sight™ 1000 Series Vision Sensors
Section 2: Installing the In-Sight 1000
2.3.1 Installing to a DHCP Network The In-Sight 1000 is factory-configured for installation on an existing network with a DHCP server. To add an In-Sight 1000 to a network using a DHCP server requires only connecting the sensor to the network and supplying power; no manual configuration of the network settings is required. NOTE
After adding an In-Sight 1000 to a network with a DHCP server, disabling DHCP on the sensor and assigning it a static IP Address is strongly recommended. For more information on disabling DHCP and assigning a static IP address, refer to the “Network Dialog” topic in the In-Sight Guide & Reference HTML Help file.
The Host Name is the only configurable network setting when using DHCP. This Host Name is an “alias” for the In-Sight 1000 sensor’s IP Address, and appears in any list of host names in the In-Sight interface. If you do not assign a new Host Name, the In-Sight 1000 will appear on the network with the default Host Name. After adding the In-Sight 1000 to the network using DHCP, proceed to Section 2.4: Logging On to the In-Sight 1000 on page 19.
2.3.2 Installing to a Non-DHCP Network To install an In-Sight 1000 sensor on a network that does not use a DHCP server, use an In-Sight 3000 or an In-Sight PC Host to manually configure the 1000 sensor's network settings. This installation may also require changes to network settings in Microsoft Windows (see Appendix A, page 35).
15
Page 24
Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
To install the In-Sight 1000 on a non-DHCP network: 1
Logon to an In-Sight 3000 or In-Sight PC Host program on the local network.
2
From the In-Sight spreadsheet, open the System menu (Figure 2-4).
Figure 2-4: System Menu
3
Select Logon to open the Logon dialog (Figure 2-5).
Figure 2-5: Logon Dialog
4
16
Select the Host Name drop-down list to see the names of any In-Sight systems already installed on the network.