Installing In-Sight 1000 Series Vision Sensors: Specifications

Pages 35 to 42 of 46, from Installing In-Sight 1000 Series Vision Sensors

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cognex In-Sight 1000

Page 35

3 Specifications In this section… 3.1

General Specifications..........................................................................................28

3.2

Detailed I/O Specifications ...................................................................................29

3.3

CAT5 Network Cable Specifications ....................................................................33

3.4

Mechanical Specifications ....................................................................................34

27

Page 36

Section 3: Specifications

Installing In-Sight™ 1000 Series Vision Sensors

3.1 General Specifications Table 3-1: In-Sight 1000/1000C General Specifications SPECIFICATION Firmware Memory Image

1000 In-Sight version 2.00 and later.

1000C In-Sight version 2.20 and later.

Job/Program

4MB non-volatile flash memory; Unlimited storage via remote network device.

Image/Processing

16MB SDRAM

Sensor

1/3-inch CCD (5.84 x 4.94 mm, 6 mm diagonal) 640 x 480 pixel display (307,200 sq. pixels, 7.4 x 7.4 µm)

same as 1000 with RGB primary color mosaic filters.

Electronic shutter speed: 64 s to 33 ms Acquisition

Rapid reset, progressive scan (supports partial scan), full-frame integration. 256 grey levels (8 bits per pixel)

16 million colors (24 bits per pixel)

Gain controlled by software. Up to 30 frames per second. I/O*

Lens Type

C-mount

Trigger

1 opto-isolated, acquisition trigger input. Remote software commands via Ethernet and RS232.

Discrete Inputs

None built-in. 8 inputs available using optional I/O Expansion Module (P/N 800-5758). Unlimited inputs using optional Ethernet I/O Module (P/N CIO-ENET-IN4).

Discrete Outputs

2 built-in, high-speed outputs 8 additional outputs available using optional I/O Expansion Module (P/N 800-5758). Unlimited outputs using optional Ethernet I/O Module (P/N CIO-ENET-OUT4).

Communications

Status LEDs

2 configurable (1 green, 1 red)

Network

1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP address. Manual reset switch disable DHCP and forces factory-assigned, static IP address.

Serial

1 RS-232C port (1200 to 115,200 baud rates)

Power Mechanical

Environmental Certifications

24 ± 10% VDC, 200mA, 4.8W supply Material

Painted aluminum housing

Mounting

One ¼-20 and two M6 threaded holes

Dimensions

118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 38.61 mm (1.52 in)

Weight

210.0 g (7.5 oz)

Temperature

10 to 45°C (Operating), -10 to 65°C (Storage)

Humidity

10 to 90%, non-condensing (Operating and Storage) CE, CUL

* See Section 3.2: Detailed I/O Specifications for more information.

28

Page 37

Installing In-Sight™ 1000 Series Vision Sensors

Section 3: Specifications

3.2 Detailed I/O Specifications The In-Sight 1000 features one built-in acquisition trigger input and two configurable discrete outputs for general-purpose use. The number of I/O lines may be increased using the optional I/O Expansion Module, which provides 8 additional discrete inputs and outputs.

3.2.1 Breakout Port Pin Assignments Table 3-2 lists the pin assignment for each of the 8 signal lines of the In-Sight 1000 Breakout Port (labeled “24VDC”) according to each method of access. Table 3-2: Breakout Port Pin Assignments IN-SIGHT BREAKOUT PORT PIN

SIGNAL

BREAKOUT CABLE WIRE COLOR

BREAKOUT MODULE* TERMINALS

EXPANSION MODULE* TERMINALS

White-Green

6, 8, 10, 12, 14, 15, 16 (+24V)

+24V

1

+24 VDC

2

Trigger +

Green

5 (TRG+)

TRG+

3

Trigger –

White-Orange

4 (TRG-)

TRG-

4

Output 0

Blue

7 (OUT0)

HSOUT0

5

Output 1

White-Blue

9 (OUT1)

HSOUT1

6

Serial Receive

Orange

RS232 serial (9-pin Dsub connector)

RS232 remote (9-pin Dsub connector)

7

Serial Transmit

White-Brown

RS232 serial (9-pin Dsub connector)

RS232 remote (9-pin Dsub connector)

8

Ground

Brown

1, 2, 3 (GND)

GND

* Refer to the In-Sight Breakout Module Installation and Reference (P/N 597-0008-xx) and the In-Sight I/O Expansion Module Installation and Reference (P/N 597-0013-xx) for more detailed information.

29

Page 38

Section 3: Specifications

Installing In-Sight™ 1000 Series Vision Sensors

3.2.2 Acquisition Trigger Input Table 3-3: Acquisition Trigger Input Specifications SPECIFICATION Voltage

DESCRIPTION ON 20 to 28V (24V nominal) OFF 0 to 3V (12V nominal threshold)

Current

ON 0.9 to 1.3mA OFF <150µA Resistance ~22,000 Ohms For higher current add external resistor (for example, 2.2kΩ, 0.5W for 12mA) across inputs.

Delay

250 µSec latency between leading edge of trigger and start of acquisition. Input pulse should be minimum of 1 ms wide.

The acquisition trigger input on the 1000 is opto-isolated. To trigger from an NPN (pulldown) type photo-detector or PLC output, connect pin 2 (TRG+) to +24V and connect pin 3 (TRG-) to the output of the detector. When the output turns ON, it pulls TRGdown to 0V, turning the opto-coupler ON. To trigger from a PNP (pull-up) photo-detector or PLC output, connect pin 2 (TRG+) to the output of the detector and connect pin 3 (TRG-) to 0V. When the output turns ON, it pulls TRG+ up to 24V, turning the opto-coupler ON. NOTE

When using the In-Sight 1000 with the Breakout Cable, the polarity of the input trigger (pins 2 and 3) is not critical. However, when using the optional Breakout or I/O Expansion Modules, the polarity of the TRG+ and TRG- terminals should be observed.

Figure 3-1: Acquisition Trigger Input Schematic

30

Page 39

Installing In-Sight™ 1000 Series Vision Sensors

Section 3: Specifications

3.2.3 Discrete Outputs Table 3-4: Discrete Output Specifications SPECIFICATION

DESCRIPTION

Voltage

28V maximum through external load.

Current

200mA maximum sink current. OFF state leakage current 200µA maximum External load resistance 120 to 10K Ohms Each line rated at a maximum 200mA, protected against over-current, short circuit, and transients from switching inductive loads. High current inductive loads require external protection diode.

Both of the built-in discrete outputs (pins 4 and 5) on the In-Sight 1000 are NPN (pulldown) lines. The external load should be connected between the output and the positive supply voltage (<28V). The outputs pull down to 0V when ON, which causes current to flow through the load. When the outputs are OFF, no current flows through the load.

Figure 3-2: Discrete Output Connection Example 1

To connect to an NPN-compatible PLC input, connect Output 0 or Output 1 directly to the PLC input. When enabled, the output pulls down the PLC input to 0V.

Figure 3-3: Discrete Output Connection Example 2

31

Page 40

Section 3: Specifications

Installing In-Sight™ 1000 Series Vision Sensors

To connect Output 0 or Output 1 to a relay, LED, or similar load, connect the negative side of the load to the output and the positive side to +24V. When the output switches on, the negative side of the load is pulled down to 0V, and 24V appears across the load. Use a protection diode for a large inductive load, with the anode connected to the output and the cathode connected to +24V.

Figure 3-4: Discrete Output Connection Example 3

In-Sight 1000 outputs can also be used with PNP-compatible PLC input if a pull-up resistor (for example, 2.2kW 0.5W) is connected from the output to +24V. In this case, the resistor supplies 24V to the PLC input. The output will pull the voltage down to 0V, turning off the PLC input. This creates an inversion, with the PLC input ON when the In-Sight output is OFF, and vice-versa. Use an external NPN to PNP converter when this inversion is not desired.

Figure 3-5: Discrete Output Connection Example 4

32

Page 41

Installing In-Sight™ 1000 Series Vision Sensors

Section 3: Specifications

3.3 CAT5 Network Cable Specifications Cognex-supplied, straight-pinned and crossover network patch cables meet CAT5/CAT5e specifications using 568-B standard wire pairing. Table 3-5: CAT5/CAT5e Network Cable Wiring STRAIGHT-PINNED

CROSSOVER

RJ-45 Connector (A)

RJ-45 Connector (B)

Connector (A)

Connector (B)

1

1

1

3

2

2

2

6

3

3

3

1

4

4

4

5

5

5

5

4

6

6

6

2

7

7

7

8

8

8

8

7

Table 3-6: CAT5/CAT5e Network Cable 568-B Wire Pairs PAIR #

WIRE PAIRS

1

4 - 5

2

1 - 2

3

3 - 6

4

7 - 8

33

Page 42

Section 3: Specifications

Installing In-Sight™ 1000 Series Vision Sensors

3.4 Mechanical Specifications The following section presents dimensional drawings for the In-Sight 1000 series vision sensors. NOTE

All dimensions are shown in millimeters (inches).

Figure 3-6: Dimensions, In-Sight 1000/1000C

34