Page 7
Installing the In-Sight 3000
Introduction The In-Sight™ 3000 is a compact, network-ready machine vision system for automated inspection, measurement, identification, alignment, and robot guidance applications on the factory floor. The In-Sight 3000 provides an intuitive spreadsheet interface for configuring and monitoring any In-Sight sensor without using a PC. Use the In-Sight 3000 to configure sensors on the local network, or remotely on another part of the network. The spreadsheet also allows local or remote monitoring of any In-Sight sensor’s operation during runtime without using a PC. This manual provides detailed information related to installing the In-Sight 3000 and testing the installation. This information appears in the following sections: G Precautions G In-Sight 3000 Configurations G Installing In-Sight PC Host Software G Connecting the In-Sight 3000 G Adding an In-Sight 3000 to a Network G Specifications
Other resources with information about the In-Sight 3000 and its spreadsheet interface include: • Getting Started with In-Sight, Cognex P/N 590-6368 (English), 590-6368F (French), 590-6368J (Japanese), or 590-6368G (German) • In-Sight Guide and Reference, an on-line HTML Help file provided on the In-Sight CD-ROM. • In-Sight computer-based tutorials provided on CD-ROM with In-Sight starter accessories kits. • The In-Sight Online Support and Learning Center (www.cognex.com/support/In-Sight.asp). Note:
Only registered In-Sight users have access to this website.
1
Page 8
Installing the In-Sight 3000
Precautions Observe these precautions when installing the In-Sight 3000 to reduce the risk of injury or equipment damage:
2 n
Do not connect the In-Sight 3000 camera or processor to a power source other than 24VDC. Any other voltage creates a risk of fire or shock and can damage the In-Sight hardware. Always observe the polarity marked on the In-Sight 3000 processor.
n
Do not connect or disconnect In-Sight hardware to any equipment that is connected to a power source. Installing or removing “live” equipment can damage In-Sight 3000 components.
n
Do not connect the In-Sight 3000 processor to a camera other than the In-Sight camera specified in this document. Connecting a camera other than an In-Sight camera to the processor can damage the camera, the In-Sight processor, or both.
n
Do not connect an In-Sight 1000 sensor to the CAMERA port on the In-Sight 3000 processor. Connecting an In-Sight 1000 sensor an In-Sight 3000 CAMERA port can damage the sensor, the processor, or both.
n
Do not install the In-Sight 3000 in locations that directly expose it to environmental hazards such as excessive heat, dust, moisture, humidity, impact, vibration, corrosive substances, flammable substances, or static electricity.
n
Do not route cables and wires connecting In-Sight hardware close to high-voltage power sources. Route cables and wires away from high-voltage power sources to reduce the risk of damage or malfunction.
n
Do not open the In-Sight 3000 processor or camera. These devices do not contain userserviceable parts. Do not make electrical or mechanical modifications to the In-Sight hardware. Unauthorized modifications violate your warranty.
Page 9
Installing the In-Sight 3000
In-Sight 3000 Configurations The In-Sight 3000 can operate as a standalone system and as a host system on a network. For the purposes of the instructions in this manual, an In-Sight network is an In-Sight 3000 connected over Ethernet to any combination of the following devices: • one or more In-Sight 3000s • one or more In-Sight 1000 sensors • one or more PCs running In-Sight PC Host software. The following sections present information related to setting up the In-Sight 3000 system in each of its basic configurations. G Standalone (Non-Network) Configuration G Standalone In-Sight Network Configurations G Factory Network Configurations
3
Page 10
Installing the In-Sight 3000
Standalone (Non-Network) Configuration A standalone (non-network) In-Sight 3000 configuration does not include connections to PCs, other In-Sight sensors, Ethernet switches, or any other network devices. Figure 1 shows this basic configuration.
Figure 1. In-Sight 3000 Standalone Configuration
The non-network, standalone configuration in Figure 1 requires a VGA monitor and In-Sight control pad to configure applications and monitor operation. There is no network connection, so the number of jobs that can be stored is limited. Images and data must be sent to remote devices for storage over a serial port, as well as jobs in excess of the limit of local storage.
4
Page 11
Installing the In-Sight 3000
Standalone In-Sight Network Configurations Standalone In-Sight network configurations include connections to other network devices (PCs, other In-Sight 3000s, or switches), but not to the larger, factory network. The following sections present information related to standalone In-Sight network configurations. G Configurations Using a CAT5 Crossover Cable G Configurations Using Switches/Routers
Configurations Using a CAT5 Crossover Cable You can create a standalone In-Sight 3000 network using a CAT5 crossover cable to connect to another In-Sight 3000, an In-Sight 1000 sensor, or a PC running In-Sight PC Host software. Figure 2 shows an In-Sight 1000 connected directly to an In-Sight 3000 processor by a CAT5 crossover cable.
Figure 2. In-Sight 3000 – In-Sight 1000 Network For the standalone network configuration shown in Figure 2, the operator would use the display and In-Sight control pad to configure applications and monitor performance. For unlimited job and image storage and data logging, instead of connecting an In-Sight 1000 to the In-Sight 3000 (Figure 2), connect a PC (with a monitor, keyboard and mouse) running In-Sight PC Host via CAT5 cable. Because users can configure applications and monitor performance with an In-Sight PC Host, the monitor and In-Sight control pad shown in Figure 2 would be optional.
5
Page 12
Installing the In-Sight 3000
Configurations Using Switches/Routers You can create a wide variety of standalone In-Sight networks using one or more network switches or routers and straight-pinned CAT5 cables. The only limit on the size of this type of network is the number of switches or routers you connect and the number of connections each switch or router provides. The standalone network shown in Figure 3 includes two optional In-Sight 1000 sensors and an optional In-Sight PC Host, as indicated by the dashed lines connecting them to the switch/router.
Figure 3. Standalone In-Sight Network with Switch/Router For the network in Figure 3, the control pad and display allow the user to configure the In-Sight 3000 and In-Sight 1000s, and the In-Sight PC Host provides job, image and data storage, and an additional display. The network switch/router could also be connected to another network switch/router, which in turn could have a similar complement of network devices. Any In-Sight system on the network can be configured from the In-Sight 3000 or the In-Sight PC Host, if used.
6
Page 13
Installing the In-Sight 3000
Factory Network Configurations As with standalone networks, you can create a virtually unlimited number of In-Sight subnets connected to a factory network, each of virtually unlimited size. Connecting the In-Sight network to the factory network allows users throughout an enterprise to access production data on a real-time basis. The In-Sight subnet shown in Figure 4 optionally includes two In-Sight 1000 sensors and an In-Sight PC Host, as indicated by the dashed lines connecting them to the switch/router.
Figure 4. Factory Network with In-Sight Subnet For networks that cover large areas, an In-Sight 3000 located on each subnet allows for local job configuration and image display without a PC.
7