The text of a manual · part 6 of 6
Installing the In-Sight 3000: Appendix A: Network Settings
Pages 40 to 43 of 43, from Installing the In-Sight 3000
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cognex In-Sight 3000
Page 40
Installing the In-Sight 3000
Appendix A: Network Settings The information in this appendix applies to In-Sight 3000 network settings. You can configure these settings from an In-Sight 3000 or In-Sight PC Host.
IP Address Like the MAC address (page 19), the IP (Internet Protocol) Address uniquely identifies the In-Sight 3000 on the network. Unlike the MAC address, the IP address must be assigned automatically by a DHCP server or manually by the user. To manually connect the In-Sight 3000 to an existing network, match the address to the existing numbering scheme. When creating a network specifically for In-Sight, we recommend the following numbering system (extracted from an MSDN document): 10.0.0.0/8
The 10.0.0.0/8 private network is a class A network ID that allows valid IP addresses from 10.0.0.1 to 10.255.255.254. The 10.0.0.0/8 private network has 24 host bits which can be used for any subnetting scheme within the private organization. The default Subnet Mask is 255.0.0.0.
172.16.0.0/12
The 172.16.0.0/12 private network can be interpreted either as a block of 16 class B network IDs or as a 20-bit assignable address space (20 host bits) which can be used for any subnetting scheme within the private organization. The 172.16.0.0/12 private network allows valid IP addresses from 172.16.0.1 to 172.31.255.254. The default Subnet Mask is 255.255.240.0.
192.168.0.0/16
The 192.168.0.0/16 private network can be interpreted either as a block of 256 class C network IDs or as a 16-bit assignable address space (16 host bits), which can be used for any subnetting scheme within the private organization. The 192.168.0.0/16 private network allows valid IP addresses from 192.168.0.1 to 192.168.255.254. The default Subnet Mask is 255.255.0.0
When DHCP is enabled, this field is grayed out and displays the value assigned by DHCP.
34
Page 41
Installing the In-Sight 3000
Subnet Mask The Subnet Mask identifies which portions of the IP number are the network portion and which are the host portion. A value of 255.255.255.0 (a class C mask) identifies 24 bits for the network portion and 8 bits for the host portion. 255.0.0.0 255.255.0.0 255.255.255.0
Class A Class B Class C
8 network/24 host 16 network/16 host 24 network/8 host
When DHCP is enabled, this field is grayed out and displays the value assigned by DHCP.
Default Gateway A gateway is a device that routes data packets from a device on the local subnet to a device on another subnet. For example, if an In-Sight 3000 will need to communicate with a device on another subnet, enter the address of the gateway device in the Default Gateway field. However, if an In-Sight 3000 will need to communicate only with devices on the local subnet, do not enter an address for the Default Gateway (leave the field all zeros).
DNS Server A Domain name (i.e., yourcompany.com) is an alias for an IP address (i.e., 198.232.76.19). A DNS (Domain Name Server) maintains the data on corresponding domain names and IP addresses. The DNS Server field determines which host is contacted (by IP address) in response to a given Domain Name.
DHCP Server The DHCP Server check box determines whether In-Sight uses DHCP (Dynamic Host Configuration Protocol) on start up or if the values in the Network Settings dialog configure TCP/IP. Check this box only if a DHCP server is running on the local network. If a DHCP server does not respond within 60 seconds, the system will boot without network support enabled. In a production environment, use static IP numbers instead of placing a check in the DHCP Server check box. Using static IP numbers removes the need for a DHCP server on the local network and eliminates intermittent DHCP traffic. The In-Sight restores the settings for static IP assignment when this box is unchecked.
35
Page 42
Installing the In-Sight 3000
Host Name Host Name determines the name that is visible to other In-Sight systems through the host browsing dialogues. This field does not automatically reflect the name given by the DHCP server or referenced through the DNS server. When the DHCP server supplies a host name, it is ignored in favor of a user supplied name or the default host name (see installation section).
Set the Domain Name An In-Sight 3000 must have a FQDN (page 23) to be configured or monitored through an In-Sight 3000 or In-Sight PC Host that is not part of the local network. The Domain field sets the string that appends to a host name to make a FQDN. For example, setting the Domain to yourcorp.com yields the following results: • if a host name is system1, the FQDN for lookup is system1.yourcorp.com. • if a host name is system1.yourcorp.com. (note the period at the end), the FQDN for lookup is system1.yourcorp.com. Appending the period to the end of the host name prevents redundancy in appending the Domain name to the FQDN (i.e., system1.yourcorp.com would become system1.yourcorp.com.yourcorp.com). When the Use DHCP Server check box is enabled, this field is grayed out and displays the value assigned by the DHCP server.
36
Page 43
Installing the In-Sight 3000 www.cognex.com/products/InSight/default.asp
P/N 597-0003-02