Installing In-Sight 4000 Series Vision Sensors: Specifications
Pages 41 to 52 of 59, from Installing In-Sight 4000 Series Vision Sensors
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cognex In-Sight 4000 Series
Page 41
Installing In-Sight™ 4000 Series Vision Sensors
3 Specifications In this section… 3.1
General Specifications ......................................................................................... 28
3.2
Detailed I/O Specifications ................................................................................... 30
3.3
CAT5 Network Cable Specifications .................................................................... 34
3.4
Mechanical Specifications .................................................................................... 35
27
Page 42
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
3.1 General Specifications Table 3-1: In-Sight 4000/4001 General Specifications SPECIFICATION Firmware Memory Image
4000
4001
In-Sight version 2.30 and later. Job/Program
8MB non-volatile flash memory; Unlimited storage via remote network device.
Image/Processing
16MB SDRAM
Sensor
1/3-inch CCD (5.84 x 4.94 mm, 6 mm diagonal)
1/3-inch CCD (5.80 x 4.92 mm, 6 mm diagonal)
640 x 480 pixel display (307,200 sq. pixels, 7.4 x 7.4 µm
1024 x 768 pixel display (786,432 sq. pixels, 4.65 x 4.65 µm)
Electronic shutter speed: .025ms to 1000ms
Electronic shutter speed: .04ms to 1000ms
Acquisition
Rapid reset, progressive scan (supports partial scan), full-frame integration. 256 gray levels (8 bits/sec) Gain controlled by software. Up to 38 frames per second
I/O*
Lens Type
C-mount
Trigger
1 opto-isolated, acquisition trigger input.
Up to 18 frames per second
Remote software commands via Ethernet and RS232. Discrete Inputs
None built-in. 8 inputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited inputs using optional Ethernet I/O Module (P/N CIO-ENET-IN4).
Discrete Outputs
2 built-in, high-speed outputs 8 additional outputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited outputs using optional Ethernet I/O Module (P/N CIO-ENET-OUT4).
Communications
Status LEDs
2 configurable (1 green, 1 red)
Network
1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP address. Manual reset switch disable DHCP and forces factory-assigned, static IP address.
Serial
1 RS-232C port (1200 to 115,200 baud rates)
Power Mechanical
Environmental Certifications
24 ± 10% VDC, 200mA, 4.8W supply Material
Painted aluminum housing
Mounting
One ¼-20 and two M6 threaded holes
Dimensions
118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 46.7 mm (1.84 in)
Weight
275.0 g (9.7 oz)
Temperature
10 to 45°C (Operating), -10 to 65°C (Storage)
Humidity
10 to 90%, non-condensing (Operating and Storage) CE, CUL
* See Section 3.2: Detailed I/O Specifications for more information.
28
Page 43
Installing In-Sight™ 4000 Series Vision Sensors
Section 3 - Specifications
Table 3-2: In-Sight 4100 General Specifications SPECIFICATION Firmware Memory Image
4100 In-Sight version 2.30 and later
Job/Program
8MB non-volatile flash memory; Unlimited storage via remote network device
Image/Processing
16MB SDRAM
Sensor
1/3-inch CCD (5.84 x 4.94 mm, 6 mm diagonal) 640 x 480 pixel display (307,200 sq. pixels, 7.4 x 7.4 µm) Electronic shutter speed: .025ms to 1000 ms
Acquisition
Rapid reset, progressive scan (supports partial scan), full-frame integration 256 gray levels (8 bits/sec) Gain controlled by software Up to 38 frames per second
I/O*
Lens Type
CS-mount and C-mount (with 5mm extension, included)
Trigger
1 opto-isolated, acquisition trigger input. Remote software commands via Ethernet and RS232.
Discrete Inputs
None built-in. 8 inputs available using optional I/O Expansion Module (P/N800-5758-1). Unlimited inputs using optional Ethernet I/O Module (P/N CIO-ENET-IN4).
Discrete Outputs
2 built-in, high-speed outputs 8 additional outputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited outputs using optional Ethernet I/O Module (P/N CIO-ENET-OUT4).
Communications
Status LEDs
2 configurable (1 green, 1 red)
Network
1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP address. Manual reset switch disables DHCP and forces factory-assigned, static IP address.
Serial
1 RS-232C port (1200 to 115,200 baud rates)
Power
24 ± 10% VDC, 250mA, 6W supply
Mechanical
Processor Housing
Painted aluminum
Remote Head Black anodized aluminum or Stainless steel (optional)
Environmental
Certifications
Mounting
One ¼-20 & two M6 threaded holes
Two M4 threaded holes
Dimensions
118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 46.7 mm (1.84 in)
5 m (16.4 ft) cable, attached
Weight
266.0 g (9.4 oz)
45.4 g (1.6 oz) without lens or cable
Temperature (Operating
10 to 45°C
10 to 50°C
Temperature (Storage)
-10 to 65°C
Humidity
10 to 90%, non-condensing (Operating and Storage)
39.1 mm (1.54 in) x 30.00 mm (1.18 in) dia.
CE, CUL
* See Section 3.2: Detailed I/O Specifications for more information.
29
Page 44
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
Table 3-3: In-Sight 4100 Remote Head Enclosure Specifications SPECIFICATION
DESCRIPTION
Material
Black anodized aluminum housing with glass window. Stainless steel housing with polycarbonate window (optional)
Dimensions
Without camera: 65.2 mm (2.57 in) high x 46.0 mm (1.81) diameter Nominal height with camera: 76.8 mm (3.03 in) to 93.0 mm (3.66 in)
Weight
136.1 g (4.8 oz), without camera
Protection
Sealed against dust and liquids to IP67 rating (NEMA 6 equivalent).
3.2 Detailed I/O Specifications The In-Sight 4000 features one built-in acquisition trigger input and two configurable discrete outputs for general-purpose use. The number of I/O lines may be increased using the optional I/O Expansion Module, which provides 8 additional discrete inputs and outputs.
3.2.1 Breakout Port Pin Assignments Table 3-4 lists the pin assignment for each of the 8 signal lines of the In-Sight 4000 Breakout Port (labeled “24VDC”) according to each method of access. Table 3-4: Breakout Port Pin Assignments IN-SIGHT BREAKOUT PORT PIN
SIGNAL
BREAKOUT CABLE WIRE COLOR
BREAKOUT MODULE* TERMINALS
EXPANSION MODULE* TERMINALS
White-Green
6, 8, 10, 12, 14, 15, 16 (+24V)
+24V
1
+24 VDC
2
Trigger +
Green
5 (TRG+)
TRG+
3
Trigger –
White-Orange
4 (TRG-)
TRG-
4
Output 0
Blue
7 (OUT0)
HSOUT0
5
Output 1
White-Blue
9 (OUT1)
HSOUT1
6
Serial Receive
Orange
RS232 serial (9-pin Dsub connector)
RS232 remote (9-pin Dsub connector)
7
Serial Transmit
White-Brown
RS232 serial (9-pin Dsub connector)
RS232 remote (9-pin Dsub connector)
8
Ground
Brown
1, 2, 3 (GND)
GND
* Refer to the In-Sight Breakout Module Installation and Reference (P/N 597-0008-xx) and the In-Sight I/O Expansion Module Installation and Reference (P/N 597-0013-xx) for more detailed information.
30
Page 45
Installing In-Sight™ 4000 Series Vision Sensors
Section 3 - Specifications
3.2.2 Acquisition Trigger Input Table 3-5: Acquisition Trigger Input Specifications SPECIFICATION Voltage
DESCRIPTION ON 20 to 28V (24V nominal) OFF 0 to 3V (12V nominal threshold)
Current
ON 0.9 to 1.3mA OFF <150µA Resistance ~22,000 Ohms For higher current add external resistor (for example, 2.2kΩ, 0.5W for 12mA) across inputs.
Delay
250 µSec latency between leading edge of trigger and start of acquisition. Input pulse should be minimum of 1 ms wide.
The acquisition trigger input on the 4000 is opto-isolated. To trigger from an NPN (pulldown) type photo-detector or PLC output, connect pin 2 (TRG+) to +24V and connect pin 3 (TRG-) to the output of the detector. When the output turns ON, it pulls TRGdown to 0V, turning the opto-coupler ON. To trigger from a PNP (pull-up) photo-detector or PLC output, connect pin 2 (TRG+) to the output of the detector and connect pin 3 (TRG-) to 0V. When the output turns ON, it pulls TRG+ up to 24V, turning the opto-coupler ON. NOTE
When using the In-Sight 4000 with the Breakout Cable, the polarity of the input trigger (pins 2 and 3) is not critical. However, when using the optional Breakout or I/O Expansion Modules, the polarity of the TRG+ and TRG- terminals should be observed.
Figure 3-1: Acquisition Trigger Input Schematic
31
Page 46
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
3.2.3 Discrete Outputs Table 3-6: Discrete Output Specifications SPECIFICATION
DESCRIPTION
Voltage
28V maximum through external load.
Current
200mA maximum sink current. OFF state leakage current 200µA maximum External load resistance 120 to 10K Ohms Each line rated at a maximum 200mA, protected against over-current, short circuit, and transients from switching inductive loads. High current inductive loads require external protection diode.
Both of the built-in discrete outputs (pins 4 and 5) on the In-Sight 4000 are NPN (pulldown) lines. The external load should be connected between the output and the positive supply voltage (<28V). The outputs pull down to 0V when ON, which causes current to flow through the load. When the outputs are OFF, no current flows through the load.
Figure 3-2: Discrete Output Connection Example 1
To connect to an NPN-compatible PLC input, connect Output 0 or Output 1 directly to the PLC input. When enabled, the output pulls down the PLC input to 0V.
Figure 3-3: Discrete Output Connection Example 2
32
Page 47
Installing In-Sight™ 4000 Series Vision Sensors
Section 3 - Specifications
To connect Output 0 or Output 1 to a relay, LED, or similar load, connect the negative side of the load to the output and the positive side to +24V. When the output switches on, the negative side of the load is pulled down to 0V, and 24V appears across the load. Use a protection diode for a large inductive load, with the anode connected to the output and the cathode connected to +24V.
Figure 3-4: Discrete Output Connection Example 3
In-Sight 4000 outputs can also be used with PNP-compatible PLC input if a pull-up resistor (for example, 2.2kΩ 0.5W) is connected from the output to +24V. In this case, the resistor supplies 24V to the PLC input. The output will pull the voltage down to 0V, turning off the PLC input. This creates an inversion, with the PLC input ON when the In-Sight output is OFF, and vice-versa. Use an external NPN to PNP converter when this inversion is not desired.
Figure 3-5: Discrete Output Connection Example 4
33
Page 48
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
3.3 CAT5 Network Cable Specifications Cognex-supplied network patch cables meet CAT5/CAT5e specifications using 568-B standard wire pairing. Table 3-7: CAT5/CAT5e Network Cable Wiring STRAIGHT-PINNED
CROSSOVER
RJ-45 Connector (A)
RJ-45 Connector (B)
Connector (A)
Connector (B)
1
1
1
3
2
2
2
6
3
3
3
1
4
4
4
5
5
5
5
4
6
6
6
2
7
7
7
8
8
8
8
7
Table 3-8: CAT5/CAT5e Network Cable 568-B Wire Pairs
34
PAIR #
WIRE PAIRS
1
4 - 5
2
1 - 2
3
3 - 6
4
7 - 8
Page 49
Installing In-Sight™ 4000 Series Vision Sensors
Section 3 - Specifications
3.4 Mechanical Specifications The following sections present dimensional drawings for the In-Sight 4000 series vision sensors. NOTE
All dimensions are shown in millimeters (inches).
3.4.1 In-Sight 4000/4001 Dimensions
Figure 3-6: Dimensions, In-Sight 4000/4001
35
Page 50
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
3.4.2 In-Sight 4100 Dimensions
Figure 3-7: Dimensions, In-Sight 4100 Processor
36
Page 51
Installing In-Sight™ 4000 Series Vision Sensors
Section 3 - Specifications
Figure 3-8: Dimensions, In-Sight 4100 Remote Head Camera
37
Page 52
Section 3 - Specifications
Installing In-Sight™ 4000 Series Vision Sensors
Figure 3-9: Dimensions, In-Sight 4100 Remote Head Camera with Enclosure
38