Page 41

Installing In-Sight™ 4000 Series Vision Sensors

3 Specifications In this section… 3.1

General Specifications ......................................................................................... 28

3.2

Detailed I/O Specifications ................................................................................... 30

3.3

CAT5 Network Cable Specifications .................................................................... 34

3.4

Mechanical Specifications .................................................................................... 35

27

Page 42

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

3.1 General Specifications Table 3-1: In-Sight 4000/4001 General Specifications SPECIFICATION Firmware Memory Image

4000

4001

In-Sight version 2.30 and later. Job/Program

8MB non-volatile flash memory; Unlimited storage via remote network device.

Image/Processing

16MB SDRAM

Sensor

1/3-inch CCD (5.84 x 4.94 mm, 6 mm diagonal)

1/3-inch CCD (5.80 x 4.92 mm, 6 mm diagonal)

640 x 480 pixel display (307,200 sq. pixels, 7.4 x 7.4 µm

1024 x 768 pixel display (786,432 sq. pixels, 4.65 x 4.65 µm)

Electronic shutter speed: .025ms to 1000ms

Electronic shutter speed: .04ms to 1000ms

Acquisition

Rapid reset, progressive scan (supports partial scan), full-frame integration. 256 gray levels (8 bits/sec) Gain controlled by software. Up to 38 frames per second

I/O*

Lens Type

C-mount

Trigger

1 opto-isolated, acquisition trigger input.

Up to 18 frames per second

Remote software commands via Ethernet and RS232. Discrete Inputs

None built-in. 8 inputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited inputs using optional Ethernet I/O Module (P/N CIO-ENET-IN4).

Discrete Outputs

2 built-in, high-speed outputs 8 additional outputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited outputs using optional Ethernet I/O Module (P/N CIO-ENET-OUT4).

Communications

Status LEDs

2 configurable (1 green, 1 red)

Network

1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP address. Manual reset switch disable DHCP and forces factory-assigned, static IP address.

Serial

1 RS-232C port (1200 to 115,200 baud rates)

Power Mechanical

Environmental Certifications

24 ± 10% VDC, 200mA, 4.8W supply Material

Painted aluminum housing

Mounting

One ¼-20 and two M6 threaded holes

Dimensions

118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 46.7 mm (1.84 in)

Weight

275.0 g (9.7 oz)

Temperature

10 to 45°C (Operating), -10 to 65°C (Storage)

Humidity

10 to 90%, non-condensing (Operating and Storage) CE, CUL

* See Section 3.2: Detailed I/O Specifications for more information.

28

Page 43

Installing In-Sight™ 4000 Series Vision Sensors

Section 3 - Specifications

Table 3-2: In-Sight 4100 General Specifications SPECIFICATION Firmware Memory Image

4100 In-Sight version 2.30 and later

Job/Program

8MB non-volatile flash memory; Unlimited storage via remote network device

Image/Processing

16MB SDRAM

Sensor

1/3-inch CCD (5.84 x 4.94 mm, 6 mm diagonal) 640 x 480 pixel display (307,200 sq. pixels, 7.4 x 7.4 µm) Electronic shutter speed: .025ms to 1000 ms

Acquisition

Rapid reset, progressive scan (supports partial scan), full-frame integration 256 gray levels (8 bits/sec) Gain controlled by software Up to 38 frames per second

I/O*

Lens Type

CS-mount and C-mount (with 5mm extension, included)

Trigger

1 opto-isolated, acquisition trigger input. Remote software commands via Ethernet and RS232.

Discrete Inputs

None built-in. 8 inputs available using optional I/O Expansion Module (P/N800-5758-1). Unlimited inputs using optional Ethernet I/O Module (P/N CIO-ENET-IN4).

Discrete Outputs

2 built-in, high-speed outputs 8 additional outputs available using optional I/O Expansion Module (P/N 800-5758-1). Unlimited outputs using optional Ethernet I/O Module (P/N CIO-ENET-OUT4).

Communications

Status LEDs

2 configurable (1 green, 1 red)

Network

1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP address. Manual reset switch disables DHCP and forces factory-assigned, static IP address.

Serial

1 RS-232C port (1200 to 115,200 baud rates)

Power

24 ± 10% VDC, 250mA, 6W supply

Mechanical

Processor Housing

Painted aluminum

Remote Head Black anodized aluminum or Stainless steel (optional)

Environmental

Certifications

Mounting

One ¼-20 & two M6 threaded holes

Two M4 threaded holes

Dimensions

118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 46.7 mm (1.84 in)

5 m (16.4 ft) cable, attached

Weight

266.0 g (9.4 oz)

45.4 g (1.6 oz) without lens or cable

Temperature (Operating

10 to 45°C

10 to 50°C

Temperature (Storage)

-10 to 65°C

Humidity

10 to 90%, non-condensing (Operating and Storage)

39.1 mm (1.54 in) x 30.00 mm (1.18 in) dia.

CE, CUL

* See Section 3.2: Detailed I/O Specifications for more information.

29

Page 44

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

Table 3-3: In-Sight 4100 Remote Head Enclosure Specifications SPECIFICATION

DESCRIPTION

Material

Black anodized aluminum housing with glass window. Stainless steel housing with polycarbonate window (optional)

Dimensions

Without camera: 65.2 mm (2.57 in) high x 46.0 mm (1.81) diameter Nominal height with camera: 76.8 mm (3.03 in) to 93.0 mm (3.66 in)

Weight

136.1 g (4.8 oz), without camera

Protection

Sealed against dust and liquids to IP67 rating (NEMA 6 equivalent).

3.2 Detailed I/O Specifications The In-Sight 4000 features one built-in acquisition trigger input and two configurable discrete outputs for general-purpose use. The number of I/O lines may be increased using the optional I/O Expansion Module, which provides 8 additional discrete inputs and outputs.

3.2.1 Breakout Port Pin Assignments Table 3-4 lists the pin assignment for each of the 8 signal lines of the In-Sight 4000 Breakout Port (labeled “24VDC”) according to each method of access. Table 3-4: Breakout Port Pin Assignments IN-SIGHT BREAKOUT PORT PIN

SIGNAL

BREAKOUT CABLE WIRE COLOR

BREAKOUT MODULE* TERMINALS

EXPANSION MODULE* TERMINALS

White-Green

6, 8, 10, 12, 14, 15, 16 (+24V)

+24V

1

+24 VDC

2

Trigger +

Green

5 (TRG+)

TRG+

3

Trigger –

White-Orange

4 (TRG-)

TRG-

4

Output 0

Blue

7 (OUT0)

HSOUT0

5

Output 1

White-Blue

9 (OUT1)

HSOUT1

6

Serial Receive

Orange

RS232 serial (9-pin Dsub connector)

RS232 remote (9-pin Dsub connector)

7

Serial Transmit

White-Brown

RS232 serial (9-pin Dsub connector)

RS232 remote (9-pin Dsub connector)

8

Ground

Brown

1, 2, 3 (GND)

GND

* Refer to the In-Sight Breakout Module Installation and Reference (P/N 597-0008-xx) and the In-Sight I/O Expansion Module Installation and Reference (P/N 597-0013-xx) for more detailed information.

30

Page 45

Installing In-Sight™ 4000 Series Vision Sensors

Section 3 - Specifications

3.2.2 Acquisition Trigger Input Table 3-5: Acquisition Trigger Input Specifications SPECIFICATION Voltage

DESCRIPTION ON 20 to 28V (24V nominal) OFF 0 to 3V (12V nominal threshold)

Current

ON 0.9 to 1.3mA OFF <150µA Resistance ~22,000 Ohms For higher current add external resistor (for example, 2.2kΩ, 0.5W for 12mA) across inputs.

Delay

250 µSec latency between leading edge of trigger and start of acquisition. Input pulse should be minimum of 1 ms wide.

The acquisition trigger input on the 4000 is opto-isolated. To trigger from an NPN (pulldown) type photo-detector or PLC output, connect pin 2 (TRG+) to +24V and connect pin 3 (TRG-) to the output of the detector. When the output turns ON, it pulls TRGdown to 0V, turning the opto-coupler ON. To trigger from a PNP (pull-up) photo-detector or PLC output, connect pin 2 (TRG+) to the output of the detector and connect pin 3 (TRG-) to 0V. When the output turns ON, it pulls TRG+ up to 24V, turning the opto-coupler ON. NOTE

When using the In-Sight 4000 with the Breakout Cable, the polarity of the input trigger (pins 2 and 3) is not critical. However, when using the optional Breakout or I/O Expansion Modules, the polarity of the TRG+ and TRG- terminals should be observed.

Figure 3-1: Acquisition Trigger Input Schematic

31

Page 46

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

3.2.3 Discrete Outputs Table 3-6: Discrete Output Specifications SPECIFICATION

DESCRIPTION

Voltage

28V maximum through external load.

Current

200mA maximum sink current. OFF state leakage current 200µA maximum External load resistance 120 to 10K Ohms Each line rated at a maximum 200mA, protected against over-current, short circuit, and transients from switching inductive loads. High current inductive loads require external protection diode.

Both of the built-in discrete outputs (pins 4 and 5) on the In-Sight 4000 are NPN (pulldown) lines. The external load should be connected between the output and the positive supply voltage (<28V). The outputs pull down to 0V when ON, which causes current to flow through the load. When the outputs are OFF, no current flows through the load.

Figure 3-2: Discrete Output Connection Example 1

To connect to an NPN-compatible PLC input, connect Output 0 or Output 1 directly to the PLC input. When enabled, the output pulls down the PLC input to 0V.

Figure 3-3: Discrete Output Connection Example 2

32

Page 47

Installing In-Sight™ 4000 Series Vision Sensors

Section 3 - Specifications

To connect Output 0 or Output 1 to a relay, LED, or similar load, connect the negative side of the load to the output and the positive side to +24V. When the output switches on, the negative side of the load is pulled down to 0V, and 24V appears across the load. Use a protection diode for a large inductive load, with the anode connected to the output and the cathode connected to +24V.

Figure 3-4: Discrete Output Connection Example 3

In-Sight 4000 outputs can also be used with PNP-compatible PLC input if a pull-up resistor (for example, 2.2kΩ 0.5W) is connected from the output to +24V. In this case, the resistor supplies 24V to the PLC input. The output will pull the voltage down to 0V, turning off the PLC input. This creates an inversion, with the PLC input ON when the In-Sight output is OFF, and vice-versa. Use an external NPN to PNP converter when this inversion is not desired.

Figure 3-5: Discrete Output Connection Example 4

33

Page 48

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

3.3 CAT5 Network Cable Specifications Cognex-supplied network patch cables meet CAT5/CAT5e specifications using 568-B standard wire pairing. Table 3-7: CAT5/CAT5e Network Cable Wiring STRAIGHT-PINNED

CROSSOVER

RJ-45 Connector (A)

RJ-45 Connector (B)

Connector (A)

Connector (B)

1

1

1

3

2

2

2

6

3

3

3

1

4

4

4

5

5

5

5

4

6

6

6

2

7

7

7

8

8

8

8

7

Table 3-8: CAT5/CAT5e Network Cable 568-B Wire Pairs

34

PAIR #

WIRE PAIRS

1

4 - 5

2

1 - 2

3

3 - 6

4

7 - 8

Page 49

Installing In-Sight™ 4000 Series Vision Sensors

Section 3 - Specifications

3.4 Mechanical Specifications The following sections present dimensional drawings for the In-Sight 4000 series vision sensors. NOTE

All dimensions are shown in millimeters (inches).

3.4.1 In-Sight 4000/4001 Dimensions

Figure 3-6: Dimensions, In-Sight 4000/4001

35

Page 50

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

3.4.2 In-Sight 4100 Dimensions

Figure 3-7: Dimensions, In-Sight 4100 Processor

36

Page 51

Installing In-Sight™ 4000 Series Vision Sensors

Section 3 - Specifications

Figure 3-8: Dimensions, In-Sight 4100 Remote Head Camera

37

Page 52

Section 3 - Specifications

Installing In-Sight™ 4000 Series Vision Sensors

Figure 3-9: Dimensions, In-Sight 4100 Remote Head Camera with Enclosure

38