Manual · Cognex
Installing In-Sight 4000 Series Vision Sensors
Manual59 pagesPDF 3.2 MB
Installation guide for the Cognex In-Sight 4000, 4001 and 4100 networked machine vision sensors, with specifications.
Covers · 1 model
The models it covers
Summary
What is in it
The Cognex installation guide for the In-Sight 4000 series networked machine vision sensors: the In-Sight 4000 and 4001 integrated processor/cameras and the In-Sight 4100 processor with remote head camera. It explains standalone and factory-floor network layouts, connecting the network cable, breakout cable, breakout module and I/O expansion module, installing the In-Sight PC Host software, adding the sensor to a DHCP or non-DHCP network and changing its network settings, and gives general, I/O, cable and mechanical specifications.
Its parts
- Introduction
- Installing the In-Sight 4000
- Specifications
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Installation manual for the Cognex In-Sight 4000 series networked machine vision sensors: the In-Sight 4000, the In-Sight 4001 and the In-Sight 4100 processor with remote head camera. It explains connecting the network cable, breakout cable and optional modules, installing In-Sight PC Host software and setting network addresses. It also gives general, I/O, network cable and mechanical specifications.
- Device
- Compact networked machine vision sensor, configured remotely from an In-Sight PC Host or In-Sight 3000 p. 15
- Models and resolution
- 4000: 640 x 480 integrated processor/camera; 4001: 1024 x 768 integrated; 4100: processor with 640 x 480 remote head camera p. 15
- Supply voltage
- 24 ± 10% VDC p. 42, 43
- Power draw
- 4000/4001: 200mA, 4.8W; 4100: 250mA, 6W p. 42, 43
- Network
- 1 Ethernet port, 10/100 BaseT, TCP/IP; DHCP (factory default) or static IP p. 42, 43
- Built-in I/O
- 1 opto-isolated acquisition trigger input, 2 high-speed discrete outputs, 1 RS-232C port (1200 to 115,200 baud) p. 42
- I/O expansion
- 8 inputs and 8 outputs with I/O Expansion Module P/N 800-5758-1; Ethernet I/O Modules CIO-ENET-IN4 and CIO-ENET-OUT4 p. 42
- Memory
- 8MB non-volatile flash for jobs; 16MB SDRAM for images p. 42, 43
- Image sensor
- 1/3-inch CCD, 256 gray levels, progressive scan p. 42, 43
- Lens mount
- 4000/4001: C-mount; 4100: CS-mount and C-mount (with 5mm extension, included) p. 42, 43
- Size and weight
- 4000/4001: 118.60 mm (4.66 in) x 43.18 mm (1.70 in) x 46.7 mm (1.84 in), 275.0 g (9.7 oz) p. 42
- Temperature
- 4000/4001: 10 to 45°C operating, -10 to 65°C storage p. 42
- Cables and modules
- Breakout Cable P/N 300-0340-15/30; Breakout Module P/N 800-5743; module cable P/N 300-0341-15; crossover coupler P/N 185-0080 p. 22, 23, 24
- PC software
- In-Sight PC Host 2.30 or later on Windows XP, 2000, NT 4.0 (Service Pack 4 or later), Me or 98SE p. 27
What this manual walks you through
- Networking several sensors through an Ethernet switch p. 18, 19
- Connecting the network cable to a switch or directly to another system p. 21, 22
- Wiring power, trigger, outputs and serial through the Breakout Cable p. 22
- Connecting the optional Breakout Module p. 23, 24
- Connecting the optional I/O Expansion Module p. 25, 26
- Installing In-Sight PC Host software on a Windows PC p. 27
- Breakout port pin assignments and wire colors p. 44
- Wiring the trigger input from NPN or PNP sensors and PLC outputs p. 45
- Wiring the discrete outputs to PLC inputs, relays or LEDs p. 46, 47
- Forcing DHCP or a static IP address with the IP Address switch p. 57, 58
Good to know
- Connect the sensor only to a 24VDC power source; other voltages risk fire, shock and damage. p. 7
- The sensor has no user-serviceable parts and should not be opened or modified. p. 7
- High current inductive loads on the outputs need an external protection diode. p. 46
- With the Breakout or I/O Expansion Modules, observe the polarity of the TRG+ and TRG- terminals. p. 45
- In-Sight PC Host software works only on a local subnet that includes a networked In-Sight sensor. p. 27
Questions this manual answers
What resolution does the In-Sight 4001 have?
1024 x 768; the In-Sight 4000 and 4100 capture 640 x 480 images. p. 15
How do I return an In-Sight 4000 to its default IP address?
Hold a paper clip in the reset switch for at least five seconds to force static IP. Without a previously assigned static address it uses 192.168.0.1 and subnet mask 255.255.255.0. p. 58
What power supply does the In-Sight 4000 need?
24 ± 10% VDC. The 4000 and 4001 draw 200mA (4.8W) and the 4100 draws 250mA (6W). p. 42, 43
How can I add more inputs and outputs to an In-Sight 4000?
The optional I/O Expansion Module (P/N 800-5758-1) adds 8 discrete inputs and 8 discrete outputs plus RS232 hardware handshaking. p. 25, 42
Which Breakout Cable wires are power and ground?
The white-green wire is +24V power and the brown wire is ground. p. 22
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file