Page 1
|) i) i i i i i cone chy Vision for Industry | n Ni ' vf -
INSTALLING IN-SIGHT” 4000 SERIES VISION SENSORS
Page 2
Page 3
Installing In-Sight™ 4000 Series Vision Sensors
Copyright, Trademarks, Patents The software described in this document is furnished under license, and may be used or copied only in accordance with the terms of such license and with the inclusion of the copyright notice shown on this page. Neither the software, this document, nor any copies thereof may be provided to or otherwise made available to anyone other than the licensee. Title to and ownership of this software remains with Cognex Corporation or its licensor. Cognex Corporation assumes no responsibility for the use or reliability of its software on equipment that is not supplied by Cognex Corporation. Cognex Corporation makes no warranties, either express or implied, regarding the described software, its merchantability or its fitness for any particular purpose. The information in this document is subject to change without notice and should not be construed as a commitment by Cognex Corporation. Cognex Corporation is not responsible for any errors that may be present in either this document or the associated software. This document may not be copied in whole or in part, nor transferred to any other media or language, without the written permission of Cognex Corporation. Cognex P/N 597-0014-03 Copyright © 2002-2003 Cognex Corporation. All Rights Reserved.
The hardware and portions of the software described in this document may be covered by one or more of the following U.S. patents. Other U.S. and foreign patents are pending. In-Sight
Patents pending
Hardware
4,972,359; 5,526,050; 5,657,403; 5,793,899
Vision Tools
5,495,537; 5,548,326; 5,583,954; 5,602,937; 5,640,200; 5,717,785; 5,742,037; 5,751,853; 5,768,443; 5,796,868; 5,818,443; 5,825,483; 5,825,913; 5,845,007; 5,859,466; 5,872,870; 5,909,504
The following are registered trademarks of Cognex Corporation: Cognex Cognex, Vision for Industry In-Sight "crosshair" logo
The following are trademarks of Cognex Corporation: The Cognex logo In-Sight
Other product and company names mentioned herein are the trademarks, or registered trademarks, of their respective owners.
i
Page 4
Installing In-Sight™ 4000 Series Vision Sensors ii
Page 5
Installing In-Sight™ 4000 Series Vision Sensors
Regulations/Compliance Declaration of Conformity Manufacturer
Cognex Corporation One Vision Drive Natick, MA 01760 USA
Declares this
-marked product
Product Number
In-Sight 4000, 4001, 4100
Complies With
73/23/EEC Low Voltage Directive 89/336/EEC Electromagnetic Compatibility Directive
Compliance Standards
EN 60950:1992 Electrical Safety A1:1993, A2:1993, A3:1995 EN 55022 RF Emissions Information Technology EN 50082-1 EMC Immunity Standard
European Representative
Cognex France Immeuble le Patio 104 avenue Albert 1er 92563 Rueil Malmaison France
Safety LISTED (UL 1950) 51KJ
CUL Certification marks are present on products iii
Page 6
Installing In-Sight™ 4000 Series Vision Sensors iv
Page 7
Installing In-Sight™ 4000 Series Vision Sensors
Precautions Observe these precautions when installing the In-Sight 4000 to reduce the risk of injury or equipment damage: !
Never connect the In-Sight 4000 to a power source other than 24VDC. Any other voltage creates a risk of fire or shock and can damage the In-Sight hardware.
!
Do not install the In-Sight 4000 in locations that directly expose it to environmental hazards such as excessive heat, dust, moisture, humidity, impact, vibration, corrosive substances, flammable substances, or static electricity.
!
To reduce the risk of damage or malfunction due to over-voltage, line noise, electrostatic discharge (ESD), power surges, or other irregularities in the power supply, route all cables and wires away from high-voltage power sources.
!
Do not open the In-Sight 4000. This device does not contain user-serviceable parts. Do not make electrical or mechanical modifications to the In-Sight hardware. Unauthorized modifications violate your warranty.
v
Page 8
vi
Installing In-Sight™ 4000 Series Vision Sensors
COGNE X
Page 9
Installing In-Sight™ 4000 Series Vision Sensors
Table of Contents 1 Introduction
1
1.1 In-Sight 4000 Series Overview..........................................................................1 1.2 In-Sight Support ................................................................................................2 1.3 Networking an In-Sight 4000 Sensor ................................................................2
2 Installing the In-Sight 4000
7
2.1 Connecting the In-Sight 4000............................................................................7 2.2 Installing In-Sight PC Host Software ...............................................................13 2.3 Adding the In-Sight 4000 to a Network ...........................................................14 2.4 Logging On to the In-Sight 4000 .....................................................................19 2.5 Changing In-Sight 4000 Network Settings ......................................................20
3 Specifications
27
3.1 General Specifications ....................................................................................28 3.2 Detailed I/O Specifications ..............................................................................30 3.3 CAT5 Network Cable Specifications ...............................................................34 3.4 Mechanical Specifications ...............................................................................35
Appendix A
39
Configuring Microsoft Windows Network Settings...................................................39
Appendix B
43
Using the IP Address Switch ...................................................................................43 vii
Page 10
Installing In-Sight™ 4000 Series Vision Sensors vii COGNEX
Page 11
Installing In-Sight™ 4000 Series Vision Sensors
List of Figures Figure 1-1: In-Sight 4000 – In-Sight PC Host Network ....................................................3 Figure 1-2: In-Sight 4000 – In-Sight 3000 Network .........................................................3 Figure 1-3: Multiple In-Sight 4000 Sensors – In-Sight PC Host Network ........................4 Figure 1-4: Multiple In-Sight 4000 Sensors – In-Sight 3000 Network..............................4 Figure 1-5: Multiple In-Sight 4000 Sensors with In-Sight 3000 and PC Host ..................5 Figure 2-1: In-Sight 4000 Network and Breakout Ports ...................................................7 Figure 2-2: Breakout Module Connections ......................................................................9 Figure 2-3: I/O Expansion Module Connections ............................................................11 Figure 2-4: System Menu...............................................................................................16 Figure 2-5: Logon Dialog ...............................................................................................16 Figure 2-6: New Host Configuration Dialog ...................................................................17 Figure 2-7: IP Configuration Message Box ....................................................................18 Figure 2-8: IP Configuration Successful Message Box .................................................18 Figure 2-9: Network Dialog ............................................................................................20 Figure 3-1: Acquisition Trigger Input Schematic............................................................31 Figure 3-2: Discrete Output Connection Example 1 ......................................................32 Figure 3-3: Discrete Output Connection Example 2 ......................................................32 Figure 3-4: Discrete Output Connection Example 3 ......................................................33 Figure 3-5: Discrete Output Connection Example 4 ......................................................33 Figure 3-6: Dimensions, In-Sight 4000/4001 .................................................................35 Figure 3-7: Dimensions, In-Sight 4100 Processor .........................................................36 Figure 3-8: Dimensions, In-Sight 4100 Remote Head Camera .....................................37 Figure 3-9: Dimensions, In-Sight 4100 Remote Head Camera with Enclosure.............38 ix
Page 12
Installing In-Sight™ 4000 Series Vision Sensors
COGNE X
Page 13
Installing In-Sight™ 4000 Series Vision Sensors
List of Tables Table 2-1: IP Address Schemes ....................................................................................22 Table 2-2: Subnet Mask Formats...................................................................................22 Table 3-1: In-Sight 4000/4001 General Specifications ..................................................28 Table 3-2: In-Sight 4100 General Specifications ...........................................................29 Table 3-3: In-Sight 4100 Remote Head Enclosure Specifications.................................30 Table 3-4: Breakout Port Pin Assignments ....................................................................30 Table 3-5: Acquisition Trigger Input Specifications........................................................31 Table 3-6: Discrete Output Specifications .....................................................................32 Table 3-7: CAT5/CAT5e Network Cable Wiring ............................................................34 Table 3-8: CAT5/CAT5e Network Cable 568-B Wire Pairs ...........................................34 xi
Page 14
Installing In-Sight™ 4000 Series Vision Sensors xii COGNEX