Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 7

Installing In-Sight 4000 Series Vision Sensors, pages 1 to 14

Pages 1 to 14 of 59

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cognex In-Sight 4000 Series

Page 1 read from a scan by OCR; it may hold reading errors

|) i) i i i i i cone chy Vision for Industry | n Ni ' vf -

INSTALLING IN-SIGHT” 4000 SERIES VISION SENSORS

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

Installing In-Sight™ 4000 Series Vision Sensors

Copyright, Trademarks, Patents The software described in this document is furnished under license, and may be used or copied only in accordance with the terms of such license and with the inclusion of the copyright notice shown on this page. Neither the software, this document, nor any copies thereof may be provided to or otherwise made available to anyone other than the licensee. Title to and ownership of this software remains with Cognex Corporation or its licensor. Cognex Corporation assumes no responsibility for the use or reliability of its software on equipment that is not supplied by Cognex Corporation. Cognex Corporation makes no warranties, either express or implied, regarding the described software, its merchantability or its fitness for any particular purpose. The information in this document is subject to change without notice and should not be construed as a commitment by Cognex Corporation. Cognex Corporation is not responsible for any errors that may be present in either this document or the associated software. This document may not be copied in whole or in part, nor transferred to any other media or language, without the written permission of Cognex Corporation. Cognex P/N 597-0014-03 Copyright © 2002-2003 Cognex Corporation. All Rights Reserved.

The hardware and portions of the software described in this document may be covered by one or more of the following U.S. patents. Other U.S. and foreign patents are pending. In-Sight

Patents pending

Hardware

4,972,359; 5,526,050; 5,657,403; 5,793,899

Vision Tools

5,495,537; 5,548,326; 5,583,954; 5,602,937; 5,640,200; 5,717,785; 5,742,037; 5,751,853; 5,768,443; 5,796,868; 5,818,443; 5,825,483; 5,825,913; 5,845,007; 5,859,466; 5,872,870; 5,909,504

The following are registered trademarks of Cognex Corporation: Cognex Cognex, Vision for Industry In-Sight "crosshair" logo

The following are trademarks of Cognex Corporation: The Cognex logo In-Sight

Other product and company names mentioned herein are the trademarks, or registered trademarks, of their respective owners.

i

Page 4

Installing In-Sight™ 4000 Series Vision Sensors ii

Page 5

Installing In-Sight™ 4000 Series Vision Sensors

Regulations/Compliance Declaration of Conformity Manufacturer

Cognex Corporation One Vision Drive Natick, MA 01760 USA

Declares this

-marked product

Product Number

In-Sight 4000, 4001, 4100

Complies With

73/23/EEC Low Voltage Directive 89/336/EEC Electromagnetic Compatibility Directive

Compliance Standards

EN 60950:1992 Electrical Safety A1:1993, A2:1993, A3:1995 EN 55022 RF Emissions Information Technology EN 50082-1 EMC Immunity Standard

European Representative

Cognex France Immeuble le Patio 104 avenue Albert 1er 92563 Rueil Malmaison France

Safety LISTED (UL 1950) 51KJ

CUL Certification marks are present on products iii

Page 6

Installing In-Sight™ 4000 Series Vision Sensors iv

Page 7

Installing In-Sight™ 4000 Series Vision Sensors

Precautions Observe these precautions when installing the In-Sight 4000 to reduce the risk of injury or equipment damage: !

Never connect the In-Sight 4000 to a power source other than 24VDC. Any other voltage creates a risk of fire or shock and can damage the In-Sight hardware.

!

Do not install the In-Sight 4000 in locations that directly expose it to environmental hazards such as excessive heat, dust, moisture, humidity, impact, vibration, corrosive substances, flammable substances, or static electricity.

!

To reduce the risk of damage or malfunction due to over-voltage, line noise, electrostatic discharge (ESD), power surges, or other irregularities in the power supply, route all cables and wires away from high-voltage power sources.

!

Do not open the In-Sight 4000. This device does not contain user-serviceable parts. Do not make electrical or mechanical modifications to the In-Sight hardware. Unauthorized modifications violate your warranty.

v

Page 8 read from a scan by OCR; it may hold reading errors

vi

Installing In-Sight™ 4000 Series Vision Sensors

COGNE X

Page 9

Installing In-Sight™ 4000 Series Vision Sensors

Table of Contents 1 Introduction

1

1.1 In-Sight 4000 Series Overview..........................................................................1 1.2 In-Sight Support ................................................................................................2 1.3 Networking an In-Sight 4000 Sensor ................................................................2

2 Installing the In-Sight 4000

7

2.1 Connecting the In-Sight 4000............................................................................7 2.2 Installing In-Sight PC Host Software ...............................................................13 2.3 Adding the In-Sight 4000 to a Network ...........................................................14 2.4 Logging On to the In-Sight 4000 .....................................................................19 2.5 Changing In-Sight 4000 Network Settings ......................................................20

3 Specifications

27

3.1 General Specifications ....................................................................................28 3.2 Detailed I/O Specifications ..............................................................................30 3.3 CAT5 Network Cable Specifications ...............................................................34 3.4 Mechanical Specifications ...............................................................................35

Appendix A

39

Configuring Microsoft Windows Network Settings...................................................39

Appendix B

43

Using the IP Address Switch ...................................................................................43 vii

Page 10 read from a scan by OCR; it may hold reading errors

Installing In-Sight™ 4000 Series Vision Sensors vii COGNEX

Page 11

Installing In-Sight™ 4000 Series Vision Sensors

List of Figures Figure 1-1: In-Sight 4000 – In-Sight PC Host Network ....................................................3 Figure 1-2: In-Sight 4000 – In-Sight 3000 Network .........................................................3 Figure 1-3: Multiple In-Sight 4000 Sensors – In-Sight PC Host Network ........................4 Figure 1-4: Multiple In-Sight 4000 Sensors – In-Sight 3000 Network..............................4 Figure 1-5: Multiple In-Sight 4000 Sensors with In-Sight 3000 and PC Host ..................5 Figure 2-1: In-Sight 4000 Network and Breakout Ports ...................................................7 Figure 2-2: Breakout Module Connections ......................................................................9 Figure 2-3: I/O Expansion Module Connections ............................................................11 Figure 2-4: System Menu...............................................................................................16 Figure 2-5: Logon Dialog ...............................................................................................16 Figure 2-6: New Host Configuration Dialog ...................................................................17 Figure 2-7: IP Configuration Message Box ....................................................................18 Figure 2-8: IP Configuration Successful Message Box .................................................18 Figure 2-9: Network Dialog ............................................................................................20 Figure 3-1: Acquisition Trigger Input Schematic............................................................31 Figure 3-2: Discrete Output Connection Example 1 ......................................................32 Figure 3-3: Discrete Output Connection Example 2 ......................................................32 Figure 3-4: Discrete Output Connection Example 3 ......................................................33 Figure 3-5: Discrete Output Connection Example 4 ......................................................33 Figure 3-6: Dimensions, In-Sight 4000/4001 .................................................................35 Figure 3-7: Dimensions, In-Sight 4100 Processor .........................................................36 Figure 3-8: Dimensions, In-Sight 4100 Remote Head Camera .....................................37 Figure 3-9: Dimensions, In-Sight 4100 Remote Head Camera with Enclosure.............38 ix

Page 12 read from a scan by OCR; it may hold reading errors

Installing In-Sight™ 4000 Series Vision Sensors

COGNE X

Page 13

Installing In-Sight™ 4000 Series Vision Sensors

List of Tables Table 2-1: IP Address Schemes ....................................................................................22 Table 2-2: Subnet Mask Formats...................................................................................22 Table 3-1: In-Sight 4000/4001 General Specifications ..................................................28 Table 3-2: In-Sight 4100 General Specifications ...........................................................29 Table 3-3: In-Sight 4100 Remote Head Enclosure Specifications.................................30 Table 3-4: Breakout Port Pin Assignments ....................................................................30 Table 3-5: Acquisition Trigger Input Specifications........................................................31 Table 3-6: Discrete Output Specifications .....................................................................32 Table 3-7: CAT5/CAT5e Network Cable Wiring ............................................................34 Table 3-8: CAT5/CAT5e Network Cable 568-B Wire Pairs ...........................................34 xi

Page 14 read from a scan by OCR; it may hold reading errors

Installing In-Sight™ 4000 Series Vision Sensors xii COGNEX