Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 2 of 7

Installing In-Sight 4000 Series Vision Sensors: Introduction

Pages 15 to 20 of 59, from Installing In-Sight 4000 Series Vision Sensors

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cognex In-Sight 4000 Series

Page 15

Installing In-Sight™ 4000 Series Vision Sensors

1 Introduction In this section… 1.1

In-Sight 4000 Series Overview............................................................................... 1

1.2

In-Sight Support ..................................................................................................... 2

1.3

Networking an In-Sight 4000 Sensor ..................................................................... 2

1.1 In-Sight 4000 Series Overview The In-Sight™ 4000 series is a family of compact, high performance, networked machine vision sensors for high-speed automated inspection, measurement, identification, alignment, and robot guidance applications on the factory floor. In-Sight 4000 sensors are configured remotely using an intuitive spreadsheet interface running on a networked In-Sight PC Host or In-Sight 3000. This spreadsheet also allows remote monitoring of sensor operation during runtime. In-Sight 4000 sensors may also be controlled remotely from users’ custom application programs using In-Sight Native Mode commands to change settings and retrieve inspection results. The In-Sight 4000 series include the following models:

# # #

In-Sight 4000 integrated processor/camera (640 x 480 image resolution) In-Sight 4001 integrated processor/camera (1024 x 768 image resolution) In-Sight 4100 processor with remote head camera ( 640 x 480 image)

The In-Sight 4100 remote head camera is available in standard anodized aluminum. Optionally, a stainless steel version is available for applications where required (e.g. food services). The remote head enclosure is also available in stainless steel with a polycarbonate window. Unless otherwise specified, references to the In-Sight 4000 in this document also apply to the In-Sight 4001 and 4100 models.

1

Page 16

Section 1 – Introduction

Installing In-Sight™ 4000 Series Vision Sensors

1.2 In-Sight Support Many information resources are available to assist you in using the In-Sight 4000 sensor and its spreadsheet interface:

#

Getting Started with In-Sight, Cognex P/N 590-6368 (English), 590-6368F (French), 590-6368G (German), or 590-6368J (Japanese).

#

In-Sight Guide & Reference, an on-line HTML Help file provided on the In-Sight CD-ROM.

#

In-Sight computer-based tutorials provided on CD-ROM with In-Sight starter accessories kits.

#

The In-Sight Online Support and Learning Center at www.cognex.com/support/In-Sight.asp.

NOTE

Only registered In-Sight users have access to the In-Sight Online Support and Learning Center website.

1.3 Networking an In-Sight 4000 Sensor An In-Sight 4000 sensor is designed to operate as a host system on an Ethernet TCP/IP network. For the purposes of the instructions in this manual, an In-Sight network exists wherever any In-Sight sensor is connected by Ethernet to at least one other In-Sight sensor or personal computer running In-Sight PC Host software. In-Sight 4000 sensors may be used in several possible network configurations. For each configuration, the In-Sight 4000 is configured from the user interface of another In-Sight system, which also provides the remote display for the In-Sight 4000.

2

Page 17

Installing In-Sight™ 4000 Series Vision Sensors

Section 1 - Introduction

1.3.1 Standalone In-Sight Network Configurations The simplest In-Sight 4000 networks are shown in Figure 1-1 and Figure 1-2. In these basic configurations, a CAT5 cable with crossover coupler (P/N 185-0080) directly connects a single In-Sight 4000 to a standalone In-Sight PC Host equipped with a network card, or to an In-Sight 3000 processor. Neither the In-Sight PC Host nor the In-Sight 3000 is connected to the larger, factory-floor network.

Figure 1-1: In-Sight 4000 – In-Sight PC Host Network

Figure 1-2: In-Sight 4000 – In-Sight 3000 Network

3

Page 18

Section 1 – Introduction

Installing In-Sight™ 4000 Series Vision Sensors

To install multiple In-Sight 4000 sensors onto a standalone In-Sight network, use an Ethernet switch between the In-Sight 4000 sensors and the In-Sight PC Host or In-Sight 3000 processor. Make all connections via standard, straight-pinned CAT5 cable (Figure 1-3 and Figure 1-4).

Figure 1-3: Multiple In-Sight 4000 Sensors – In-Sight PC Host Network

Figure 1-4: Multiple In-Sight 4000 Sensors – In-Sight 3000 Network

The number of In-Sight sensors and In-Sight PC Hosts that may be installed on a standalone In-Sight network are limited only by the number of ports available on the Ethernet switch. To expand a standalone In-Sight network, add Ethernet switches as needed to increase the number of available network ports.

4

Page 19

Installing In-Sight™ 4000 Series Vision Sensors

Section 1 - Introduction

1.3.2 Factory-Floor In-Sight Network Configurations To take full advantage of their data sharing and remote monitoring capabilities, In-Sight sensors should be connected to the larger, factory-floor network. The only physical difference between factory-networked In-Sight sensors and a standalone In-Sight network is that the Ethernet switch is itself connected to the factory-floor network. Groups of In-Sight systems connected to the factory-floor network through a common Ethernet switch are referred to as a local network, or subnet. Figure 1-5 shows a subnet that includes two In-Sight 4000 sensors, an In-Sight 3000, and an In-Sight PC Host.

Figure 1-5: Multiple In-Sight 4000 Sensors with In-Sight 3000 and PC Host

NOTE

In-Sight 4000 sensors can be connected to the factory network even if there is no In-Sight PC Host or In-Sight 3000 processor on the same subnet. In this configuration, any In-Sight 3000 processor or PC Host on any other subnet on the network can provide remote configuration and display service to the In-Sight 4000 sensors on a different subnet.

5

Page 20 read from a scan by OCR; it may hold reading errors

Section 1, Introduction Installing In-Sight™ 4000 Series Vision Sensors

6 COGNE X