Page 57
Installing In-Sight™ 4000 Series Vision Sensors
Appendix B Using the IP Address Switch All In-Sight 4000 series sensors feature a manual switch that can be used to change IP address settings to a known state when performing one of the following actions:
#
Using Native Mode commands to change network settings on a non-DHCP network (or serial port) when an In-Sight PC Host is unavailable;
#
Troubleshooting network connection problems.
The IP Address switch has two modes of operation:
Force DHCP Force DHCP mode enables the Use DHCP Server checkbox (see Section 2.5.1: Use DHCP Server on page 21), overriding the sensor’s current Static IP address and allowing a DCHP server to automatically assign the In-Sight sensor a network IP address and Subnet Mask. If the Use DHCP Server checkbox is already enabled, no changes to the IP address will occur. The sensor’s Serial Port 1 Mode setting is also changed to ‘Native’ to allow Network settings to be configured from a remote RS232 device. To force DHCP mode, insert the end of a paper clip into the sensor’s IP Address switch. Depress the switch once and remove the paper clip. When all three LEDs have stopped blinking, the sensor has been restarted. These settings will remain in effect even after the sensor is powered down.
Figure B-1: IP Address Switch Operation
43
Page 58
Appendix B
Installing In-Sight™ 4000 Series Vision Sensors
Force Static IP Force Static IP mode disables the Use DHCP Server checkbox. If a static IP address and Subnet Mask were previously assigned to the In-Sight system, those settings will be used, otherwise, the factory default static IP Address (192.168.0.1) and Subnet Mask (255.255.255.0) will be used. If the Use DHCP Server checkbox is already disabled, no changes to the IP address will occur. Like force DHCP mode, force static IP mode changes the sensor’s Serial Port 1 Mode setting to ‘Native’ to allow Network settings to be configured from an RS232 device. To Force Static IP mode, insert the end of a paper clip into the sensor’s reset switch. Depress the switch for at least five seconds, then remove the paper clip. When all three LEDs have stopped blinking, the sensor has been restarted. These settings will remain in effect even after the sensor is powered down.
44