The text of a manual · part 10 of 16
M-Drive User Manual, pages 91 to 100
Pages 91 to 100 of 160
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Fenner M-DRIVE-4 and Contrex M-DRIVE-4
Page 91
OFFSET SPEED CONTROL FORMAT INTRODUCTION The Offset Speed Control format differs from Follower Format in two respects:
1. Offset provides for a second process variable in addition to the External Reference Frequency.
2. Offset allows the programmer to specify a speed difference (or offset) from the normally calculated Follower speed.
Consequently, the Offset Format motor speed is controlled by four variables: Ratio Setpoint, External Reference Frequency, Auxiliary Reference Frequency, and the user specified offset. .
Appendix B lists the actual formulas used to calculate the motor speed for both Follower Format and Offset Format.
OFFSET FORMAT EXAMPLE
Figure 8-1 below illustrates a simple web process. Note that this application contains a loop which is controlled by a dancer POT. The example illustrates the use of a voltage controlled oscillator from the dancer POT to the Auxiliary Frequency Input. (The Analog Input could also be used, eliminating the VCO.) The frequency output of the oscillator is then applied to J3 pin 8 of the Follower M-Drive. Depending on this output value, the M- Drive adjusts the speed of the Follower Motor up or down as required to maintain the dancer POT position.
Follower J3-5 J3-2 f - M-Drive 33-5
Master 33-8 M-Drive voo pW e Le
Dancer POT
Figure 8-1: Web Process illustrating Offset Format
Page 8-3
OFFSET SPEED CONTROL FORMAT INTRODUCTION The Offset Speed Control format differs from Follower Format in two respects:
1. Offset provides for a second process variable in addition to the External Reference Frequency.
2. Offset allows the programmer to specify a speed difference (or offset) from the normally calculated Follower speed.
Consequently, the Offset Format motor speed is controlled by four variables: Ratio Setpoint, External Reference Frequency, Auxiliary Reference Frequency, and the user specified offset. .
Appendix B lists the actual formulas used to calculate the motor speed for both Follower Format and Offset Format.
OFFSET FORMAT EXAMPLE
Figure 8-1 below illustrates a simple web process. Note that this application contains a loop which is controlled by a dancer POT. The example illustrates the use of a voltage controlled oscillator from the dancer POT to the Auxiliary Frequency Input. (The Analog Input could also be used, eliminating the VCO.) The frequency output of the oscillator is then applied to J3 pin 8 of the Follower M-Drive. Depending on this output value, the M- Drive adjusts the speed of the Follower Motor up or down as required to maintain the dancer POT position.
Follower
J3-5 J3-2 r - M-Drive 33-5 Master 33-8 M-Drive 6eT 68T / / eee al, _ - Dancer POT
Figure 8-1: Web Process illustrating Offset Format
Page 8-3
Page 92
Recall that in this case two frequencies are used by the Follower M-Drive to determine the required follower Motor RPM: Line Speed (the external reference supplied by the Master Motor Feedback), and dancer POT position (the auxiliary reference supplied by the VCO). Also note that it is possible to control the gain on the POT displacement from the center position and to bias or offset the result with the user specified constant. The Tach is explained later in this chapter.
This example uses Secondary Mode, but the Primary Mode would work as well.
ASSUMPTIONS 0 Nip rolls in Figure 8-1 are 1 foot in circumference o Follower Motor is to draw the web at the same linear speed as the Master
(1800 feet per minute at 1800 RPM)
Both gears have 60 teeth
Master is scaled as per chapter six (Page 6-5)
Desired Follower Setpoint is 1.000
VCO output range is 0 - 1000 Hz (500 Hz = dancer centered)
Full scale authority of the dancer POT is 10% of full speed (I.e., a 1000 Hz change in Aux Frequency shouid result ina 180 RPM change in the follower motor speed).
oo0o0°0o
Ignoring the dancer pot, first program the M-Drive to follow at the proper line speed:
Recall that in this case two frequencies are used by the Follower M-Drive to determine the required follower Motor RPM: Line Speed (the external reference supplied by the Master Motor Feedback), and dancer POT position (the auxiliary reference supplied by the VCO). Also note that it is possible to control the gain on the POT displacement from the center position and to bias or offset the result with the user specified constant. The Tach is explained later in this chapter.
This example uses Secondary Mode, but the Primary Mode would work as well.
ASSUMPTIONS 0 Nip rolls in Figure 8-1 are 1 foot in circumference oO Follower Motor is to draw the web at the same linear speed as the Master
(1800 feet per minute at 1800 RPM)
Both gears have 60 teeth
Master is scaled as per chapter six (Page 6-5)
Desired Follower Setpoint is 1.000
VCO output range is 0 - 1000 Hz (500 Hz = dancer centered)
Full scale authority of the dancer POT is 10% of full speed (I.e., a 1000 Hz change in Aux Frequency shouid result ina 180 RPM change in the follower motor speed).
oo0o0°0o
Ignoring the dancer pot, first program the M-Drive to follow at the proper line speed:
Control Parameter Entered
Parameter Title Data Remarks
CP-62 Secondary 3 Designates Secondary as Offset Format Scaling Format
CP-37 Secondary 1800 Maximum RPM of the shaft which the
RPM Feedback Maximum feedback sensor is monitoring (normal operation)
CP-36 Secondary 1800 Maximum RPM of the shaft which the external RPM External reference sensor is monitoring Reference (normal operation) Maximum
CP-21 Secondary 1.000 Desired setpoint when the Ext. Ref. and Feedback Setpoint shafts are rotating at the speeds entered at Engineering CP-37 and CP-36 Units
CP-31 PPR 60 Number of teeth on the gear or number of lines Feedback on the encoder used for feedback
CP-30 PPR Ext 60 Number of teeth on the gear or number of lines Ref. on the encoder used for external reference
Page 8-4
Control Parameter Entered
Parameter Title Data Remarks
CP-62 Secondary 3 Designates Secondary as Offset Format Scaling Format
CP-37 Secondary 1800 Maximum RPM of the shaft which the
RPM Feedback feedback sensor is monitoring
Maximum (normal operation)
CP-36 Secondary 1800 Maximum RPM of the shaft which the external RPM Externai reference sensor is monitoring Reference (normal operation) Maximum
CP-21 Secondary 1.000 Desired setpoint when the Ext. Ref. and Feedback Setpoint shafts are rotating at the speeds entered at Engineering CP-37 and CP-36 Units
CP-31 PPR 60 Number of teeth on the gear or number of lines Feedback on the encoder used for feedback
CP-30 PPR Ext 60 Number of teeth on the gear or number of lines Ref. on the encoder used for external reference
Page 8-4
Page 93
The next step is to program the Auxiliary Reference Frequency input which represents the Dancer POT position (the VCO output). Two characteristics of this input must be controlied: Offset and Gain. The Offset determines which frequency will have no effect on the M-Drive’s speed (j.e., which position the dancer POT stabilizes at). The Gain determines how large an impact on the speed a given change in the Auxiliary Reference Frequency will have. As the Auxiliary Frequency source (in this case) is a VCO instead of a gear and sensor, it may be helpful to review the material on alternative frequency sources on Page 5-16.
Recalf that the authority or gain of the dancer POT was assumed to be 10%. To accomplish this, entries are made indicating that the maximum expected Auxiliary Reference Frequency is 10,000 Hz when if fact it will never exceed the 1000 Hz output of the VCO. This provides the 10 to 1 reduction needed.
Control Parameter Entered
Parameter Title Data Remarks
CP-38 Secondary 1000 A RPM Auxil. Maximum
CP-32 PPR Aux. 600 These two entries imply the 10,000 Hz maximum Ref. as required
The last step is to enter an offset so that a centered POT (500 Hz) has no effect. This offset depends on the gain and is calculated using the formula:
- | AX* Rimx * Pf C= Rarmx * Pa
Where: C= the required offset = the maximum RPM of the feedback shaft (CP-37) in the example. Pf = PPR of the gear on the feedback shaft (CP-31) Ramx = the maximum RPM of the auxiliary shaft (CP-38) Pa = PPR of the gear on the auxiliary shaft (CP-32) AX = the frequency at which the POT is to be neutralized (500 Hz)
A Refer to the programming conventions used when using Hz instead of RPM and PPR as discussed in Chapter 5.
Page 8-5
The next step is to program the Auxiliary Reference Frequency input which represents the Dancer POT position (the VCO output). Two characteristics of this input must be controlled: Offset and Gain. The Offset determines which frequency will have no effect on the M-Drive’s speed (j.e., which position the dancer POT stabilizes at). The Gain determines how large an impact on the speed a given change in the Auxiliary Reference Frequency will have. As the Auxiliary Frequency source (in this case) is a VCO instead of a gear and sensor, it may be helpful to review the material on alternative frequency sources on Page 5-16.
Recall that the authority or gain of the dancer POT was assumed to be 10%. To accomplish this, entries are made indicating that the maximum expected Auxiliary Reference Frequency is 10,000 Hz when if fact it will never exceed the 1000 Hz output of the VCO. This provides the 10 to 1 reduction needed.
Control Parameter Entered
Parameter Title Data Remarks
CP-38 Secondary 1000 A RPM Auxil. Maximum
CP-32 PPR Aux. 600 These two entries imply the 10,000 Hz maximum Ref. as required
The last step is to enter an offset so that a centered POT (500 Hz) has no effect. This offset depends on the gain and is calculated using the formula:
- | AX * Rimx * Pf C= Ramx * Pa
Where: C= the required offset = the maximum RPM of the feedback shaft (CP-37) in the example. Pf = PPR of the gear on the feedback shaft (CP-31) Ramx = the maximum RPM of the auxiliary shaft (CP-38) Pa = PPR of the gear on the auxiliary shaft (CP-32) AX = the frequency at which the POT is to be neutralized (500 Hz)
A Refer to the programming conventions used when using Hz instead of RPM and PPR as discussed in Chapter 5.
Page 8-5
Page 94
Replacing the variables with the example numbers, the Offset is then calculated. Note the minus sign in front of the right-hand expression.
- 500 * 1800 * 60 C= 1000 * 600 C= -90 Control Parameter Entered Parameter Title Data Remarks CP-78 Secondary 90 Programming is complete Negative Offset
CP-77 and CP-78 work together in that CP-77 is a plus offset and CP-78 is a negative Offset. Note that only one of these parameters can have a non-zero value at a time. Whenever an entry is made at one location, the M-Drive automatically sets the other to zero. Codes CP-75 and CP-76 work the same but are in the Primary Parameter group.
Page 8-6
Replacing the variables with the example numbers, the Offset is then calculated. Note the minus sign in front of the right-hand expression.
- 500 * 1800 * 60 C= 41000 * 600 C= -90 Control Parameter Entered Parameter Title Data __ Remarks CP-78 Secondary 90 Programming is complete Negative Offset
CP-77 and CP-78 work together in that CP-77 is a plus offset and CP-78 is a negative Offset. Note that only one of these parameters can have a non-zero value at a time. Whenever an entry is made at one location, the M-Drive automatically sets the other to zero. Codes CP-75 and CP-76 work the same but are in the Primary Parameter group.
Page 8-6
Page 95
ADDITIONAL SETPOINT AND TACHOMETER POSSIBILITIES
SETPOINT POSSIBILITIES
The programmer is not prevented from designating the same format for both Primary and Secondary modes. E.g., CP-61 and CP-62 could both be loaded with a *2", giving two independent Follower formulas. In addition, both parameter groups could be loaded with the same system constants but four setpoints would be available.
TACHOMETER POSSIBILITIES
Chapter five assumed that the Master Format tach would always indicate the speed of the motor scaled in some appropriate engineering unit, and that the Follower Format tach would display a ratio between the two motors. Just as it is possible to use any combination of speed scaling formats and modes, it is possible to use any combination of tach scaling formats and modes. The most likely case is probably a Follower Speed control using a speed tach instead of a ratio tach.
ANALOG INPUT/OUTPUT PROGRAMMING (OPTIONAL)
ANALOG INPUT
The Analog input can be used to replace any of the three frequency inputs or four setpoint values. To allocate the Analog input to a specific function, enter the correct value for CP-84 according to the table below:
I< oo. Ic io)
Analog Function
Not Used
External Reference Frequency Replacement Feedback Frequency Replacement
Offset Frequency Replacement
CP-1 (Setpoint 1) Replacement
CP-2 (Setpoint 2) Replacement
CP-3 (Setpoint 3) Replacement
CP-4 (Setpoint 4) Replacement
NOOR OM O
Table 8-1: CP-84 - Analog Input Allocation Codes
Page 8-7
ADDITIONAL SETPOINT AND TACHOMETER POSSIBILITIES
SETPOINT POSSIBILITIES
The programmer is not prevented from designating the same format for both Primary and Secondary modes. E.g., CP-61 and CP-62 could both be loaded with a *2", giving two independent Follower formulas. In addition, both parameter groups could be loaded with the same system constants but four setpoints would be available.
TACHOMETER POSSIBILITIES
Chapter five assumed that the Master Format tach would always indicate the speed of the motor scaled in some appropriate engineering unit, and that the Follower Format tach would display a ratio between the two motors. Just as it is possible to use any combination of speed scaling formats and modes, it is possible to use any combination of tach scaling formats and modes. The most likely case is probably a Follower Speed control using a speed tach instead of a ratio tach.
ANALOG INPUT/OUTPUT PROGRAMMING (OPTIONAL) ANALOG INPUT The Analog input can be used to replace any of the three frequency inputs or four setpoint values. To allocate the Analog input to a specific function, enter the correct value for CP-84 according to the table below:
I< 9. Ic i)
Analog Function
Not Used
External Reference Frequency Replacement Feedback Frequency Replacement
Offset Frequency Replacement
CP-1 (Setpoint 1) Replacement
CP-2 (Setpoint 2) Replacement
CP-3 (Setpoint 3) Replacement
CP-4 (Setpoint 4) Replacement
NOOAROM =O
Table 8-1: CP-84 - Analog Input Allocation Codes
Page 8-7
Page 96
When the Analog Input is allocated to replace one of the frequency inputs, the M-Drive automatically adjusts the corresponding PPR and RPM MAX codes for that frequency input. It sets the PPR value to 60 and RPM MAX values to 4095. For example, if the user enters a value of 1 for CP-84, the M-Drive then sets CP-30 to 60, CP-33 to 4095 and CP- 36 to 4095. This is equivalent to having an input frequency of 4095 HZ (4095 RPMs with a 60 tooth gear) when the Analog Input is at its maximum level.
To complete the programming process, simply enter in the desired Engineering Unit values (at CP-20 through CP-23 and CP-75 through CP-78) that correspond to the maximum Analog Input value.
if an analog input level less than full scale is used, it is necessary to proportionally adjust the appropriate Engineering Unit parameter. For example, if a 0 to 5 VDC input corresponds to an Engineering Unit of 15 gallons/minute, the user enters an Engineering Unit value of 30 gallons/minute for the 0 to 10 VDC equivalent value.
The following examples illustrate the use of the Analog Input in the Master, Follower and Offset Modes.
Page 8-8
When the Analog Input is allocated to replace one of the frequency inputs, the M-Drive automatically adjusts the corresponding PPR and RPM MAX codes for that frequency input. It sets the PPR value to 60 and RPM MAX values to 4095. For example, if the user enters a value of 1 for CP-84, the M-Drive then sets CP-30 to 60, CP-33 to 4095 and CP- 36 to 4095. This is equivalent to having an input frequency of 4095 HZ (4095 RPMs with a 60 tooth gear) when the Analog Input is at its maximum level.
To complete the programming process, simply enter in the desired Engineering Unit values (at CP-20 through CP-23 and CP-75 through CP-78) that correspond to the maximum Analog Input value.
if an analog input level less than full scale is used, it is necessary to proportionally adjust the appropriate Engineering Unit parameter. For example, if a 0 to 5 VDC input corresponds to an Engineering Unit of 15 gallons/minute, the user enters an Engineering Unit value of 30 gallons/minute for the 0 to 10 VDC equivalent value.
The following examples illustrate the use of the Analog Input in the Master, Follower and Offset Modes.
Page 8-8
Page 97
MASTER FORMAT, ANALOG INPUT AS SETPOINT
A pump delivers 15 gallons/minute when the motor rotates at 1725 RPMs. An analog POT connected to the M-Drive analog input produces a 5 volt DC level
ASSUMPTIONS fo) fo) when the motor rotates at 1725 RPMs. fo)
Both Setpoint and the Tach are to indicate gallons per minute.
To accomplish these objectives, program the M-Drive as follows:
Control Parameter Title
CP-84
CP-61
CP-63
CP-31
CP-34
CP-20
CP-22
Parameter Entered Data
Analog 4 Function
Primary 1 Scalirig Format
Primary 1 Display Format
PPR 60 Feedback
Primary 1725 RPM MAX Feedback
Primary 30.00 Setpoint Engn. Units
Primary 15.00 Display Engn. Units
Remarks
Allocates Analog input as CP-1 (Setpoint 1) replacement.
Designates Master as the Primary Scaling Format.
Designates Master as the Primary Display Format
Designates the value used as a multiplier to obtain the desired authority of the analog input.
Designates maximum RPM of Feedback sensor shaft.
Designates the maximum setpoint engineering units at the maximum analog level of 10 VDC.
Designates the maximum display engineering units.
Page 8-9
MASTER FORMAT, ANALOG INPUT AS SETPOINT ASSUMPTIONS ie] ie]
(e)
A pump delivers 15 gallons/minute when the motor rotates at 1725 RPMs.
An analog POT connected to the M-Drive analog input produces a 5 volt DC level when the motor rotates at 1725 RPMs.
Both Setpoint and the Tach are to indicate gallons per minute.
To accomplish these objectives, program the M-Drive as follows:
Control
Parameter
Parameter Title
CP-84
CP-61
CP-63
CP-31
CP-34
CP-20
CP-22
Analog Function
Primary Scaling Format
Primary Display Format
PPR Feedback
Primary RPM MAX Feedback
Primary Setpoint Engn. Units
Primary
Display Engn. Units
Entered Data
4
60
1725
30.00
15.00
Remarks
Allocates Analog input as CP-1 (Setpoint 1) replacement.
Designates Master as the Primary Scaling Format.
Designates Master as the Primary Display Format
Designates the value used as a multiplier to obtain the desired authority of the analog input.
Designates maximum RPM of Feedback sensor shaft.
Designates the maximum setpoint engineering units at the maximum analog level of 10 VDC.
Designates the maximum display engineering units.
Page 8-9
Page 98
MASTER FORMAT, ANALOG INPUT AS FEEDBACK
ASSUMPTIONS o Apump delivers 15 gallons/minute when the motor rotates at 1725 RPMs.
© Ananalog tach connected to the M-Drive analog input produces a 10 volt DC level when the motor is to rotate 1725 RPMs. © Both Setpoint and the Tach are to indicate gallons per minute.
To accomplish these objectives, program the M-Drive as follows:
Control Parameter
CP-84
CP-61
CP-63
CP-31
CP-34
CP-20
CP-22
Parameter Title
Analog Function
Primary Scaling Format
Primary Display Format
PPR Feedback
Primary RPM MAX Feedback
Primary Setpoint Engn. Units
Primary Display Engn. Units
Entered
Data
2
60
4095
15.00
15.00
Remarks
Allocates Analog Input as feedback frequency replacement
Designates Master as the Primary Scaling Format
Designates Master as the Primary Display Format
Not Entered. Automatically entered by the M-Drive and cannot be altered. Not Entered. Automatically entered by the
M-Drive and cannot be altered.
Designates the maximum setpoint engineering units.
Designates the maximum display engineering units.
FOLLOWER FORMAT, ANALOG INPUT AS EXTERNAL REFERENCE ASSUMPTIONS
0 The Setpoint and Tach are to reflect the flow ratio in gallons/minute of B to A.
9 The Motor/Pump combination used for Component A delivers 10 gallons /minute at 1725 RPMs.
o The Motor/Pump combination used for Component B delivers 30 gallons /minute at 1725 RPMs.
Page 8-10
MASTER FORMAT, ANALOG INPUT AS FEEDBACK
ASSUMPTIONS ie) ie)
ie)
A pump delivers 15 gallons/minute when the motor rotates at 1725 RPMs.
An analog tach connected to the M-Drive analog input produces a 10 volt DC level when the motor is to rotate 1725 RPMs.
Both Setpoint and the Tach are to indicate gallons per minute.
To accomplish these objectives, program the M-Drive as follows:
Control
Parameter
Parameter Title
CP-84
CP-61
CP-63
CP-31
CP-34
CP-20
CP-22
Analog Function
Primary Scaling Format
Primary Display Format
PPR Feedback
Primary RPM MAX Feedback
Primary Setpoint Engn. Units
Primary Display Engn. Units
Entered
Data
2
60
4095
15.00
15.00
Remarks
Allocates Analog Input as feedback frequency replacement
Designates Master as the Primary Scaling Format
Designates Master as the Primary Display Format
Not Entered. Automatically entered by the M-Drive and cannot be altered. Not Entered. Automatically entered by the
M-Drive and cannot be altered.
Designates the maximum setpoint engineering units.
Designates the maximum display engineering units.
FOLLOWER FORMAT, ANALOG INPUT AS EXTERNAL REFERENCE ASSUMPTIONS
The Setpoint and Tach are to reflect the flow ratio in gallons/minute of B to A. The Motor/Pump combination used for Component A delivers 10 gallons /minute
The Motor/Pump combination used for Component B delivers 30 gallons /minute
{e} {e} at 1725 RPMs. ie) at 1725 RPMs. Page 8-10
Page 99
o An analog tach produces 10 VDC when the motor on Component A is at 1725 RPMs. o A230 tooth gear is used for the follower feedback (Component B)
CALCULATIONS
1. Determine the fiow ratio that exists when both components are flowing at maximum rates.
30 Gal/minute (Component B) = 3.000 10 Gal/minute (Component A)
To accomplish the above objectives, program the M-Drive as follows:
Control Parameter
CP-84
CP-62
CP-64
CP-37
CP-36
CP-31
CP-30
CP-21
CP-23
Parameter Entered Title Data
Analog 1 Function
Secondary 2 Scaling Format
Secondary 2 Display Format
Secondary 1725 RPM Feedback Max
Secondary 4095 RPM
External
Ref. MAX
PPR 30 Feedback
PPR 60 External Reference
Secondary 3.000 Setpoint Engn. Units
Secondary 3.000 Display Engn. Units
Remarks
Allocates the analog input as ext. ref. freq. replacement
Designates Follower as the Secondary setpoint scaling format
Designates Follower as the Secondary display scaling format
Maximum RPM of the shaft which the feedback sensor monitors
Not Entered. Automatically entered by the M-Drive and cannot be altered.
Number of teeth on the gear or number of lines on the encoder used for feedback
Not Entered. Automatically entered by the M-Drive and cannot be altered.
Page 8-11 o An analog tach produces 10 VDC when the motor on Component A is at 1725 RPMs. o A 30 tooth gear is used for the follower feedback (Component B)
CALCULATIONS
1. Determine the fiow ratio that exists when both components are flowing at maximum rates.
30_Gal/minute (Component B) = 3.000 10 Gal/minute (Component A)
To accomplish the above objectives, program the M-Drive as follows:
Control Parameter
CP-84
CP-62
CP-64
CP-37
CP-36
CP-31
CP-30
CP-21
CP-23
Parameter Entered Title Data
Analog 1 Function
Secondary 2 Scaling Format
Secondary 2 Display Format
Secondary 1725 RPM Feedback Max
Secondary 4095 RPM
External
Ref. MAX
PPR 30 Feedback
PPR 60 External Reference
Secondary 3.000
Setpoint Engn. Units
Secondary 3.000
Display Engn. Units
Remarks
Allocates the analog input as ext. ref. freq. replacement
Designates Follower as the Secondary setpoint scaling format
Designates Follower as the Secondary display scaling format
Maximum RPM of the shaft which the feedback sensor monitors
Not Entered. Automatically entered by the M-Drive and cannot be altered.
Number of teeth on the gear or number of lines on the encoder used for feedback
Not Entered. Automatically entered by the M-Drive and cannot be altered.
Page 8-11
Page 100
OFFSET FORMAT, ANALOG INPUT AS AUX FREQUENCY INTRODUCTION The Offset Speed Control format differs from Follower Format in two respects:
1. Offset provides for a second process variable in addition to the External Reference Frequency.
2. Offset allows the programmer to specify a speed difference (or offset) from the normally calculated Follower speed.
Consequently, the Offset Format motor speed is controlled by four variables: Ratio Setpoint, External Reference Frequency, Analog Input as Aux (Offset) Frequency, and the user specified offset.
Appendix 8 lists the actual formulas used to calculate the motor speed for both Follower Format and Offset Format.
OFFSET FORMAT EXAMPLE
Figure 8-2 below illustrates a simple web process. Note that this application contains a loop which is controlled by a dancer POT. The example uses a dancer POT on the Analog Input. Depending on the output value, the M-Drive adjusts the speed of the Follower Motor up or down as required to maintain the dancer POT position.
Follower 33-5 33-2 r< - M-Drive J3-5 Master M-Drive J4-16
Dancer POT
Figure 8-2: Web Process illustrating Offset Format with Analog Input Page 8-12
OFFSET FORMAT, ANALOG INPUT AS AUX FREQUENCY INTRODUCTION The Offset Speed Control format differs from Follower Format in two respects:
1. Offset provides for a second process variable in addition to the External Reference Frequency.
2. Offset allows the programmer to specify a speed difference (or offset) from the normally calculated Follower speed.
Consequently, the Offset Format motor speed is controlled by four variables: Ratio Setpoint, External Reference Frequency, Analog Input as Aux (Offset) Frequency, and the user specified offset.
Appendix 8 lists the actual formulas used to calculate the motor speed for both Follower Format and Offset Format.
OFFSET FORMAT EXAMPLE
Figure 8-2 below illustrates a simple web process. Note that this application contains a loop which is controlled by a dancer POT. The example uses a dancer POT on the Analog Input. Depending on the output value, the M-Drive adjusts the speed of the Follower Motor up or down as required to maintain the dancer POT position.
Follower 33-5 33-2 r< - M-Drive J3-5 Master M-Drive J4-16
Dancer POT
Figure 8-2: Web Process illustrating Offset Format with Analog Input Page 8-12