Manual · Contrex
M-Drive User Manual
Manual160 pagesPDF 1.8 MB
User manual for the Contrex M-Drive motor speed controller: configuration, installation, calibration, programming and maintenance.
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
Contrex user manual with the information needed to install, calibrate and operate the M-Drive Motor Speed Controller. Its 9 chapters cover an introduction to the M-Drive, hardware configuration, mounting and wiring, calibration of current limit and optional analog input and output, programming and tuning, theory of operation, RS422 serial communications, advanced programming and maintenance with trouble-shooting. Specifications and appendices with code lists, pin out and typical wiring diagrams are included.
Its parts
- Introduction
- Configuration
- Installation
- Calibration
- Programming
- Theory of Operation
- Serial Communication
- Advanced Programming
- Maintenance
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Contrex user manual (0001-0091, Rev G) for the M-Drive digital motor speed controller for DC motors. It covers configuration, mounting and wiring, calibration, programming, serial communications, advanced programming and maintenance, with feedback sensor parts. The manual names the drive only as the M-Drive; it does not print the M-DRIVE-4 designation.
- Type
- Digital motor speed drive in a 1/2 DIN enclosure for DC permanent magnet or field wound motors, 1/4 to 2 hp p. 13
- Drive output
- Phase fired, single quadrant: 0-90 V, 1/4 to 1 HP (115 VAC input); 0-180 V, 1/2 to 2 HP (230 VAC input) p. 11
- Power
- 115/230 VAC -10% +15%, 50/60 Hz; 0.1 Amps plus motor current p. 12
- Serial port
- RS-422, 300 to 9600 baud, full parameter access and control from a host computer p. 12, 13
- Dimensions
- 7.5 in. high, 3.9 in. wide, 6.0 in. deep p. 12
- Operating temperature
- Up to 40 degrees C ambient outside an enclosure of at least 12 x 10 x 8 in.; max. 55 degrees C inside it p. 12
- Frequency inputs
- Zero cross (magnetic pickup) or open-collector (proximity or encoder); 0 - 30 KHz feedback and external reference open collector p. 11
- Control inputs
- Required: Run, R-Stop, F-Stop; elective: jog, closed/open loop, primary/secondary mode, setpoint selects, ramp disable, keypad lockout, remote scroll p. 7
- Status outputs
- Zero speed, high alarm, low alarm, ramped error, scaled error; open-collector, 50 VDC max, 200 mA continuous p. 7, 11
- Accuracy
- .01% of set speed in master format; zero accumulative error in follower format; 10 ms control loop update p. 10
- Setpoints
- 4 preset master/follower setpoints plus 1 direct and 1 jog p. 10, 13
- Keypad
- Sealed keypad: operator panel plus a programming panel behind a separate door; dedicated SET SPEED and TACH keys p. 13
- Analog option
- Optional analog input/output board, 12 bit resolution p. 6, 11
- Sensor accessories
- Ring kits RK56C, RK143TC, RK182TC, RK213TC, RK254TC (and -30 versions); sensor models SM3N, SM3N-A, SM5XP, SP8IS, SP8N3, ENCDR-600, ENCDR-1200 p. 122
What this manual walks you through
- Setting up frequency inputs, the analog option and power voltage p. 6
- Mounting the drive and wiring inputs, outputs and the motor p. 7
- Calibrating current limit and analog input/output p. 5
- Programming tuning, acceleration, limits and alarms p. 8
- Setting up serial communications with a host computer p. 9
- Power-up RAM and PROM tests p. 105
- Running the built-in diagnostic tests p. 106, 107, 108, 109
- Troubleshooting by symptom p. 110
- Restoring factory default settings p. 105
- Spare parts and feedback sensor parts lists p. 116, 122
Good to know
- The drive is a control component; the user is responsible for safe system design, and installation should follow the National Electrical Code. p. 3
- Hazardous voltages are present during some troubleshooting procedures; only qualified electrical maintenance personnel should perform them. p. 110
- Install the drive in a pollution degree 2 macro-environment. p. 12
- The output test needs pull-up resistors and a meter or LED. p. 108
Questions this manual answers
What motors can the Contrex M-Drive control?
DC permanent magnet or field wound motors from 1/4 to 2 horsepower: 0-90 V up to 1 HP on 115 VAC, 0-180 V up to 2 HP on 230 VAC. p. 11, 13
How do I start the M-Drive diagnostic tests?
Remove power, then hold Clear and 4 on the keypad while applying power; if no 1 appears, repeat with Clear and 8, then pick one of seven tests with UP or DOWN. p. 106
What serial interface does the M-Drive have?
An RS-422 port running at 300 to 9600 baud, with full parameter access and control. p. 12, 13
How big is the M-Drive?
7.5 inches high, 3.9 inches wide and 6.0 inches deep, in a 1/2 DIN enclosure. p. 12, 13
What does a number on the M-Drive display at power up mean?
During the power-up RAM test a displayed number means the RAM failed; the RAM address is the number plus 49152, and the factory should be consulted. p. 105
The whole text · 16 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
The file