45 - SCALED REFERENCE
The Scaled Reference is the scaled setpoint number in hertz. The Scaled Reference is the calculated variable input to the Acceleration/Deceleration routine. See Note on Page C-6.
46 - RAMPED REFERENCE
The Ramped Reference is the calculated output of the Acceleration/Deceleration routine in hertz. The Ramped Reference is the setpoint input to the control algorithm. See Note on Page C-6.
47 - OUTPUT
The Output variable represents the level of the Drive Output to the motor. The Output variable is represented in percent of full output.
48 - TRIM OUTPUT
The Trim Output is the calculated output of the contro! algorithm. It is equivalent to the total output minus the feedforward {output(47) = Trim Output (48) + Feedforward}. The Trim Output is represented in DAC bits where 4096 equals 100% output, 2048 equals 50% output, etc.
49 - PULSE ERROR COUNT
The Pulse Error Count indicates the difference between the number of External Reference pulses received and the number of Feedback pulses received during the Follower Scaling Mode of operation. It is an indicator of the position error between the lead and follower devices. This error is cleared to zero when the M- Drive enters a stop state.
50 - ACTIVE MODE
The Active Mode is an M-Drive status indicator of the active scaling mode.
0 - Direct Mode
1 - Master Mode 2 - Follower Mode 3 - Offset Mode
A description of these modes is available in the Control Parameters - Scaling Mode Control section of the manual. ;
Page C-7
45 - SCALED REFERENCE
The Scaled Reference is the scaled setpoint number in hertz. The Scaled Reference is the calculated variable input to the Acceleration/Deceleration routine. See Note on Page C-6.
46 - RAMPED REFERENCE
The Ramped Reference is the calculated output of the Acceleration/Deceleration routine in hertz. The Ramped Reference is the setpoint input to the control algorithm. See Note on Page C-6.
47 - OUTPUT
The Output variable represents the level of the Drive Output to the motor. The Output variable is represented in percent of full output.
48 - TRIM OUTPUT
The Trim Output is the calculated output of the contro! algorithm. It is equivalent to the total output minus the feedforward {output(47) = Trim Output (48) + Feedforward}. The Trim Output is represented in DAC bits where 4096 equals 100% output, 2048 equals 50% output, etc.
49 - PULSE ERROR COUNT
The Pulse Error Count indicates the difference between the number of External Reference pulses received and the number of Feedback pulses received during the Follower Scaling Mode of operation. It is an indicator of the position error between the lead and follower devices. This error is cleared to zero when the M- Drive enters a stop state.
50 - ACTIVE MODE
The Active Mode is an M-Drive status indicator of the active scaling mode.
0 - Direct Mode
1 - Master Mode 2 - Follower Mode 3 - Offset Mode
A description of these modes is available in the Control Parameters - Scaling Mode Control section of the manual. ;
Page C-7
Page 132
51 - ENTRY ERRORS
The Entry Errors display can be used to indicate why a keypad entry was not accepted by the M-Drive.
0 - No Error
1 - Invalid Code
2 - Above Maximum Value 3 - Below Minimum Value 4 - Keypad Lockout
5 - Entry Timeout
If an entry is not accepted by the M-Drive, the last valid value is displayed. Code 51 can be used to interrogate why the new value was not accepted.
52 - ALARM STATUS
The Alarm Status display indicates the status of the limits and alarms in the M- Drive. The presence of the number associated with that alarm indicates that alarm is active.
1 - Low Limit
2 - High Limit
3 - Low Alarm
4 - High Alarm
5 - Error Alarm 1 6 - Error Alarm 2 7 - Current Limit
53 - CONTROL STATE
The Control State display indicates the control or operating state of the M-Drive.
1 - Jog 32 - Run 64 - Ramped Stop 128- Fast Stop
Page C-8
51 - ENTRY ERRORS
The Entry Errors display can be used to indicate why a keypad entry was not accepted by the M-Drive.
0 - No Error
1 - Invalid Code
2 - Above Maximum Value 3 - Below Minimum Value 4 - Keypad Lockout
5 - Entry Timeout
If an entry is not accepted by the M-Drive, the last valid value is displayed. Code 51 can be used to interrogate why the new value was not accepted.
52 - ALARM STATUS
The Alarm Status display indicates the status of the limits and alarms in the M- Drive. The presence of the number associated with that alarm indicates that alarm is active.
1 - Low Limit
2 - High Limit
3 - Low Alarm
4 - High Alarm
5 - Error Alarm 1 6 - Error Alarm 2 7 - Current Limit
53 - CONTROL STATE
The Control State display indicates the control or operating state of the M-Drive.
1 - Jog 32 - Run 64 - Ramped Stop 128- Fast Stop
Page C-8
Page 133
54 - CONTROL MODE
The Control Mode display indicates the status of the optional switch inputs to the M- Drive. This number is a weighted sum of the numbers associated with the switched inputs. This code, along with code 53, is intended for use by the computer interface. It is available through the keypad for trouble-shooting convenience only.
128 - Primary Mode/Secondary Mode 64 -NotUsed
32 - Closed/Open_Loop
16 - Pri. Setpt. 1/Pri. Setpt. 2
- Sec. Setpt. 3/Sec. Setpt. 4
- Local/Computer.
- Keypad Enable/Disable - Ramp Enable/Ramp Disable, =rp Ow
To decode the display, subtract the highest number from the above list consecutively from the display number.
For example, a display of 178 would be decoded as: 178 -128 Primary Mode 50 +32 Closed Loop
18 -16 Primary Setpoint 1 th
-_2 Keypad Enable o
Also Secondary Setpoint 4, Computer, Setpoint Hold because these numbers were not subtractable.
55 - A/D INPUT
The A/D Input display indicates the status of the Analog Input. This number is filtered but is not zero and span adjusted.
56 - A/D INPUT - ADJUSTED
This monitor variable displays the status of the Analog Input after the zero and span calculations have been made.
Page C-9
54 - CONTROL MODE
The Control Mode display indicates the status of the optional switch inputs to the M- Drive. This number is a weighted sum of the numbers associated with the switched inputs. This code, along with code 53, is intended for use by the computer interface. It is available through the keypad for trouble-shooting convenience only.
128 - Primary Mode/Secondary Mode 64 -NotUsed
32 - Closed/Open_Loop
16 - Pri. Setpt. 1/Pri. Setpt. 2
8 - Sec. Setpt. 3/Sec. Setpt. 4 - Local/Computer.
4 2 - Keypad Enable/Disable 1 - Ramp Enable/Ramp Disable
To decode the display, subtract the highest number from the above list consecutively from the display number.
For example, a display of 178 would be decoded as: 178 -128 Primary Mode -32 Closed Loop
18 -16 Primary Setpoint 1 ft
-_2 Keypad Enable oO
Also Secondary Setpoint 4, Computer, Setpoint Hold because these numbers were not subtractable.
55 - A/D INPUT
The A/D Input display indicates the status of the Analog Input. This number is filtered but is not zero and span adjusted.
56 - A/D INPUT - ADJUSTED
This monitor variable displays the status of the Analog Input after the zero and span calculations have been made.
Page C-9
Page 134
57 - POWER LINE FAILURE
MV- 57 is a counter that is incremented every time the AC line falls below the specified level. It can be used to determine if inductive loads are causing line notches or dips. The count can be reset to zero by pressing the “Clear” key when this variable is accessed.
58 - SERIAL COMMUNICATIONS ERROR
MV-58 displays the communications error code for the last message transmitted to the M-Drive. This code is intended for use by the communications interface, and is a weighted sum of the error code bit pattern:
32 Data was out of minimum/maximum range
16 Invalid Parameter Code, Checksum or Decimal Point Error
8 Receive buffer filled before ETX received or Message Format Error 4 Invalid Parameter Data
2 Parity error
1 M-Drive in Local not Computer Mode
0 No errors
To decode the display, subtract the highest number from the list consecutively from the display number.
For example, a display of 37 would be decoded as:
37 -32 Data out of minimum/maximum range
Invalid Parameter Data
M-Drive in Local not Computer Mode
MV-59: FREQUENCY OVERFLOW MV-59 is a counter that is incremented every time the frequency inputs to the M-
Drive cause an overflow. The count can be reset to zero by pressing the “Clear” key when this variable is accessed.
60 - CURRENT LIMIT RESPONSE This parameter can be used to adjust the Current Limit response rate. A higher value for CP-60 will reduce the phase angle at a faster rate going into and out of current limit.
Page C-10
57 - POWER LINE FAILURE
MV- 57 is a counter that is incremented every time the AC line falls below the specified level. It can be used to determine if inductive loads are causing line notches or dips. The count can be reset to zero by pressing the “Clear” key when this variable is accessed.
58 - SERIAL COMMUNICATIONS ERROR
MV-58 displays the communications error code for the last message transmitted to the M-Drive. This code is intended for use by the communications interface, and is a weighted sum of the error code bit pattern:
32 Data was out of minimum/maximum range
16 Invalid Parameter Code, Checksum or Decimal Point Error
8 Receive buffer filled before ETX received or Message Format Error 4 Invalid Parameter Data
2 Parity error
1 M-Drive in Local not Computer Mode
0 No errors
To decode the display, subtract the highest number from the list consecutively from the display number.
For example, a display of 37 would be decoded as:
37 -32 Data out of minimum/maximum range
Invalid Parameter Data
M-Drive in Local not Computer Mode
MV-59: FREQUENCY OVERFLOW MV-59 is a counter that is incremented every time the frequency inputs to the M-
Drive cause an overflow. The count can be reset to zero by pressing the “Clear” key when this variable is accessed.
60 - CURRENT LIMIT RESPONSE This parameter can be used to adjust the Current Limit response rate. A higher value for CP-60 will reduce the phase angle at a faster rate going into and out of current limit.
Page C-10
Page 135
61 - PRIMARY SCALING MODE
This parameter selects the scaling format that is used for setpoint calculation when the Primary Scaling mode is switch selected.
0 - Direct 1 - Master
2 - Follower 3 - Offset
62 - SECONDARY SCALING MODE
This parameter selects the scaling format that is used for setpoint calculation when the Secondary Scaling Mode is switch selected.
0 - Direct 1 - Master
2 - Follower 3 - Offset
63 - PRIMARY DISPLAY MODE
This parameter selects the scaling format that is used for the display calculation when the Primary Scaling Mode is switch selected.
1 - Master 2 - Follower
64 - SECONDARY DISPLAY MODE
This parameter selects the scaling format that is used for the display calculation when the Secondary Scaling Mode is switch selected.
1 - Master 2 - Follower
65 -GAIN
Small numbers increase the contribution of the Proportional component (of the PID) except that an entry of "0" eliminates the Gain contribution.
Page C-11
61 - PRIMARY SCALING MODE
This parameter selects the scaling format that is used for setpoint calculation when the Primary Scaling mode is switch selected.
0 - Direct 1 - Master
2 - Follower 3 - Offset
62 - SECONDARY SCALING MODE
This parameter selects the scaling format that is used for setpoint calculation when the Secondary Scaling Mode is switch selected.
0 - Direct 1 - Master
2 - Follower 3 - Offset
63 - PRIMARY DISPLAY MODE
This parameter selects the scaling format that is used for the display calculation when the Primary Scaling Mode is switch selected.
1 - Master 2 - Follower
64 - SECONDARY DISPLAY MODE
This parameter selects the scaling format that is used for the display calculation when the Secondary Scaling Mode is switch selected.
1 - Master 2 - Follower
65 -GAIN
Small numbers increase the contribution of the Proportional component (of the PID) except that an entry of "0" eliminates the Gain contribution.
Page C-11
Page 136
66 - RESET (Integral)
Small numbers increase the contribution of the integral component (of the PID) except that an entry of "0" eliminates the Reset contribution.
67 - RATE (Derivative)
Small numbers increase the contribution of the Differential component (of the PID) except that an entry of “O" eliminates the Rate contribution.
68 - TRIM AUTHORITY
Trim Authority determines how much of the output is influenced by the Gain, Reset and Rate terms, and how much is determined by feedforward. If it is not possible to achieve stable operation with 100% Trim Authority, reduce this parameter and repeat the tuning procedure.
69 - RATE THRESHOLD
If erratic operation is exhibited only at very low feedback frequencies, the Rate Threshold can be increased slightly. This parameter determines the minimum amount of differential error required before the Rate term influences the control output.
70 - DEVICE ADDRESSES
The M-Drive has a settable physical address from 1 to 32. This is used to separately identify the individual M-Drive units on a multidropped RS422 line. Address references to 0 will globally be accepted by all M-Drive Units.
71 - BAUD RATE
There are six different baud or data rates for the M-Drive:
300 Baud 600 Baud 1200 Baud 2400 Baud 4800 Baud 9600 Baud
Onrnhwan - Page C-12
66 - RESET (Integral)
Small numbers increase the contribution of the integral component (of the PID) except that an entry of "0" eliminates the Reset contribution.
67 - RATE (Derivative)
Small numbers increase the contribution of the Differential component (of the PID) except that an entry of “O" eliminates the Rate contribution.
68 - TRIM AUTHORITY
Trim Authority determines how much of the output is influenced by the Gain, Reset and Rate terms, and how much is determined by feedforward. If it is not possible to achieve stable operation with 100% Trim Authority, reduce this parameter and repeat the tuning procedure.
69 - RATE THRESHOLD
If erratic operation is exhibited only at very low feedback frequencies, the Rate Threshold can be increased slightly. This parameter determines the minimum amount of differential error required before the Rate term influences the control output.
70 - DEVICE ADDRESSES
The M-Drive has a settable physical address from 1 to 32. This is used to separately identify the individual M-Drive units on a multidropped RS422 line. Address references to 0 will globally be accepted by all M-Drive Units.
71 - BAUD RATE
There are six different baud or data rates for the M-Drive:
300 Baud 600 Baud 1200 Baud 2400 Baud 4800 Baud 9600 Baud
Onhran =
Page C-12
Page 137
72 - CHARACTER FORMAT
The M-Drive accepts 3 different character formats:
8 Data Bits, No Parity, One Stop Bit 7 Data Bits, Even Parity, One Stop Bit 8
1 2 3 Data Bits, No Parity, Two Stop Bits
73 - CONTROL MASK
When the computer control is switch selected, it is possible to allow the computer to control some of the functions associated with the discrete switch inputs. These include:
= Ramp_Enable/Disable
= Run/R-Stop
= Secondary Setpoint Select = Primary Setpoint Select
= Closed/Open Loop
64 = Not Use
1
4 8
6 32
1 1 28 = Primary/Secondary Control Mode
To delegate contro! of the selected function to the computer, simply add the associated function number to the total. For example, a value of 36 for code 73 would mean the computer has control of the Closed/Open Loop and the Run/R- Stop functions.
74 - ZERO SPEED LOGIC
CP-74 determines the logic of the zero speed discrete output. If CP-74 = "0", the output is controlled only by the Ramped Reference (MV-46). If CP-74 = "1", the output is controlled by both the Ramped Reference and the Feedback (MV-43).
The direct effects of CP-74 on the output are:
QO Output is HIGH whenever the Ramped Ref is “O" and LOW whenever the Ramped Ref is not "0".
1. Output is LOW whenever Ramped Ref is not "0", but will not go HIGH until both the Ramped Ref and Feedback are "0". Once HIGH the output will not go LOW until the Ramped Ref is not "0".
75 - PRIMARY MODE POSITIVE OFFSET
CP-75 is the Primary Mode Positive Offset.
Note: Refer to Chapter 8 for a full discussion of CP-75, CP-76, CP-77, and CP-78. Page C-13
72 - CHARACTER FORMAT
The M-Drive accepts 3 different character formats:
8 Data Bits, No Parity, One Stop Bit 7 Data Bits, Even Parity, One Stop Bit 8
1 2 3 Data Bits, No Parity, Two Stop Bits
73 - CONTROL MASK
When the computer control is switch selected, it is possible to allow the computer to control some of the functions associated with the discrete switch inputs. These include:
1 = Ramp_Enable/Disable
4 = Run/R-Stop
8 = Secondary Setpoint Select
16 = Primary Setpoint Select
32 = Closed/Open Loop
64 = Not Use
128 = Primary/Secondary Control Mode
To delegate contro! of the selected function to the computer, simply add the associated function number to the total. For example, a value of 36 for code 73 would mean the computer has control of the Closed/Open Loop and the Run/R- Stop functions.
74 - ZERO SPEED LOGIC
CP-74 determines the logic of the zero speed discrete output. If CP-74 = "0", the output is controlled only by the Ramped Reference (MV-46). If CP-74 = "1", the output is controlled by both the Ramped Reference and the Feedback (MV-43).
The direct effects of CP-74 on the output are:
QO Output is HIGH whenever the Ramped Ref is “O" and LOW whenever the Ramped Ref is not "0".
1 Output is LOW whenever Ramped Ref is not "0", but will not go HIGH until both the Ramped Ref and Feedback are “O". Once HIGH the output will not go LOW until the Ramped Ref is not "0".
75 - PRIMARY MODE POSITIVE OFFSET
CP-75 is the Primary Mode Positive Offset.
Note: Refer to Chapter 8 for a full discussion of CP-75, CP-76, CP-77, and CP-78. Page C-13
Page 138
76 - PRIMARY MODE NEGATIVE OFFSET 76 - PRIMARY MODE NEGATIVE OFFSET
CP-76 is the Primary Mode Negative Offset. CP-76 is the Primary Mode Negative Offset. 77 - SECONDARY MODE POSITIVE OFFSET 77 - SECONDARY MODE POSITIVE OFFSET CP-77 is the Secondary Mode Positive Offset. CP-77 is the Secondary Mode Positive Offset. 78 - SECONDARY MODE NEGATIVE OFFSET 78 - SECONDARY MODE NEGATIVE OFFSET CP-78 is the Secondary Mode Negative Offset. CP-78 is the Secondary Mode Negative Offset.
79 - SETPOINT MASK 79 - SETPOINT MASK
CP-79 determines which setpoints are disabled when the keypad is locked out (see Page 3-14). The table below identifies the enable/disable status during a keypad lockout for each valid CP-79 value.
CP-79 Setpoints Setpoints Value Enabled Disabled ie} 1,2,3,4 None 1 None 1,2,3,4 2 1,3 2,4
80 - ANALOG OUTPUT FUNCTION SELECT
CP-80 allocates the Analog Output to the desired Monitor Variable or Control Parameter. Allocation is accomplished by entering the corresponding code number (CP-xx or MV-xx} for the selected variable into CP-80.
81 - ANALOG OUTPUT RANGE
CP-81 ranges the selected CP-80 variable by determining the value for the selected variable that provides a 100% analog output signal.
Page C-14
CP-79 determines which setpoints are disabled when the keypad is locked out (see Page 3-14). The table below identifies the enable/disable status during a keypad lockout for each valid CP-79 value.
CP-79 Setpoints Setpoints Value Enabled Disabled ie} 1,2,3,4 None 1 None 1,2,3,4 2 1,3
$3
80 - ANALOG OUTPUT FUNCTION SELECT
CP-80 allocates the Analog Output to the desired Monitor Variable or Control Parameter. Allocation is accomplished by entering the corresponding code number (CP-xx or MV-xx} for the selected variable into CP-80.
81 - ANALOG OUTPUT RANGE
CP-81 ranges the selected CP-80 variable by determining the value for the selected variable that provides a 100% analog output signal.
Page C-14
Page 139
82 - ANALOG OUTPUT ZERO
CP-82 is used to zero a the Analog Output during calibration. For further details, refer to Chapter 4 (Calibration).
83 - ANALOG OUTPUT SPAN
CP-83 is used to span “Cait the Analog Output during calibration. For further details, refer to Chapter 4 (Calibration).
84 - ANALOG INPUT FUNCTION SELECT
CP-84 allocates the Analog Input to the desired function. Allocation is accomplished by entering one of the following codes into CP-84:
Code Function
Analog Input Not Used
External Reference Freq. Replacement Feedback Frequency Replacement Offset Frequency Replacement Setpoint 1 Replacement
Setpoint 2 Replacement
Setpoint 3 Replacement
Setpoint 4 Replacement
NOORWDN =O
85 - ANALOG INPUT ZERO
CP-85 is used to zero adjust the Analog Input during calibration. For further details, refer to Chapter 4 (Calibration).
86 - ANALOG INPUT SPAN
CP-86 is used to span adjust the Analog Input during calibration. For further details, refer to Chapter 4 (Calibration).
99 - SOFTWARE CODE REVISION
MV-99 displays the code revision number of the M - Drive's software (EPROM).
00 - SOFTWARE PART NUMBER
MV-00 displays the last four digits of the eight digit part number for the M - Drive's software (EPROM). The first four digits are assumed to be “1000”.
Page C-15
82 - ANALOG OUTPUT ZERO
CP-82 is used to zero nO the Analog Output during calibration. For further details, refer to Chapter 4 (Calibration).
83 - ANALOG OUTPUT SPAN
CP-83 is used to span “Cait the Analog Output during calibration. For further details, refer to Chapter 4 (Calibration).
84 - ANALOG INPUT FUNCTION SELECT
CP-84 allocates the Analog Input to the desired function. Allocation is accomplished by entering one of the following codes into CP-84:
Code Function
Analog Input Not Used
External Reference Freq. Replacement Feedback Frequency Replacement Offset Frequency Replacement Setpoint 1 Replacement
Setpoint 2 Replacement
Setpoint 3 Replacement
Setpoint 4 Replacement
NOORWNM=O
85 - ANALOG INPUT ZERO
CP-85 is used to zero adjust the Analog Input during calibration. For further details, refer to Chapter 4 (Calibration).
86 - ANALOG INPUT SPAN
CP-86 is used to span adjust the Analog Input during calibration. For further details, refer to Chapter 4 (Calibration).
99 - SOFTWARE CODE REVISION
MV-99 displays the code revision number of the M - Drive's software (EPROM).
00 - SOFTWARE PART NUMBER
MV-00 dispiays the last four digits of the eight digit part number for the M - Drive's software (EPROM). The first four digits are assumed to be “1000”.
Page C-15