BRACKET MOUNT SENSORS

Bracket mount sensors are usually magnetic pickup sensors or proximity sensors, and do not require the use of an aluminum ring. Figure A-3 below is a typical example of a bracket mounted sensor.

Figure A-3 illustrates an SM3N magnetic pickup assembly which is mounted through a .437 clearance hole in a formed metal bracket fabricated by the user. The metal bracket must be sturdy and mounted to avoid vibrations and machine resonance.

SM3N MAGNETIC PICKUP

FIBER WASHERS STAR WASHER

BRACKET «005 GAP 2.003

*Installed to insulate pickup from the bracket.

Figure A-3: Typical Bracket Mounted Magnetic Pickup

Page A-3

BRACKET MOUNT SENSORS

Bracket mount sensors are usually magnetic pickup sensors or proximity sensors, and do not require the use of an aluminum ring. Figure A-3 below is a typical example of a bracket mounted sensor.

Figure A-3 illustrates an SM3N magnetic pickup assembly which is mounted through a .437 clearance hole in a formed metal bracket fabricated by the user. The metal bracket must be sturdy and mounted to avoid vibrations and machine resonance.

SM3N MAGNETIC PICKUP

FIBER WASHERS STAR WASHER

PN pencner

-005 GAP +.003

*Installed to insulate pickup from the bracket.

Figure A-3: Typical Bracket Mounted Magnetic Pickup

Page A-3

Page 122 read from a scan by OCR; it may hold reading errors

FEEDBACK SENSOR PARTS LIST

RING KITS: Part Number Model Number

7300-0980 RK56C 7300-0982 RK143TC 7300-0934 RK182TC 7300-0936 RK213TC 7300-0987 RK254TC 7300-0981 RK56C-30 7300-0983 RK143TC-30 7300-0984 RK182TC-30 7300-0985 RK213TC-30 7300-0986 RK254TC-30 7300-1310 RK56C 7300-1311 RK143TC

SENSOR ACCESSORIES: Part Number Model Number

5800-1410 SM3N 5800-1412 SM3N-A 6500-0033 SM5XP

3100-1190 SP8IS 5800-1413 SP8N3 3200-1340 ENCDR-600 3200-1350 ENCDR-1200

7000-0450 R56CXP GEARS: Part Number Model Number

5800-0340 G60T5 5800-0341 G60T7 5800-0435 G60T9 5800-0345 G60T11 5800-0346 G60T13 7300-0376 G20T2 5800-0382 G30TS 5800-0383 G30T7 5800-0347 G30TS 5800-0348 G30T11 5800-0349 G30T13

Page A4

Description

Sensor Kit w/60T gear - 5/8 inch Sensor Kit w/60T gear - 7/8 inch Sensor Kit w/60T gear - 1 1/8 inch Sensor Kit w/60T gear - 1 3/8 inch Sensor Kit w/60T gear - 1 5/8 inch Sensor Kit w/30T gear - 5/8 inch Sensor Kit w/30T gear - 7/8 inch Sensor Kit w/30T gear - 1 1/8 inch Sensor Kit w/30T gear - 1 3/8 inch Sensor Kit w/30T gear - 1 5/8 inch Quadrature Ring Kit - 5/8 inch Quadrature Ring Kit - 7/8 inch

Description

Magnetic Pickup, Threaded Magnetic Pickup, Smooth Magnetic Pickup, Explosion Proof

Proximity Sensor, intrinsically save with amp

Proximity Sensor, 3-wire Encoder, 10v, 600 PPR Encoder, 10v, 1200 PPR

Flange Ring only, 56C, for SM5XP sensor

Description

Gear, 60T, 5/8 inch Gear, 60T, 7/8 inch Gear, S0T, 1 1/8 inch Gear, S0T, 1 3/8 inch Gear, S0T, 1 5/8 inch Sprocket, 20T, 1/4 inch Gear, 30T, 5/8 inch Gear, 30T 7/8 inch Gear, 30T, 1 1/8 inch Gear, 30T, 1 3/8 inch Gear, 30T, 1 5/8 inch

FEEDBACK SENSOR PARTS LIST

RING KITS: Part Number Model Number

7300-0980 RK56C 7300-0982 RK143TC 7300-0934 RK182TC 7300-0936 RK213TC 7300-0987 RK254TC 7300-0981 RK56C-30 7300-0983 RK143TC-30 7300-0984 RK182TC-30 7300-0985 RK213TC-30 7300-0986 RK254TC-30 7300-1310 RK56C 7300-1311 RK143TC

SENSOR ACCESSORIES: Part Number Model Number

5800-1410 SM3N 5800-1412 SM3N-A 6500-0033 SM5XP

3100-1190 SP8IS 5800-1413 SP8N3 3200-1340 ENCDR-600 3200-1350 ENCDR-1200

7000-0450 R56CXP GEARS: Part Number Model Number

5800-0340 G60T5 5800-0341 G60T7 5800-0435 G60T9 5800-0345 G60T11 5800-0346 G60T13 7300-0376 G20T2 5800-0382 G30TS 5800-0383 G30T7 5800-0347 G30TS 5800-0348 G30T11 5800-0349 G30T13

Page A4

Description

Sensor Kit w/60T gear - 5/8 inch Sensor Kit w/60T gear - 7/8 inch Sensor Kit w/60T gear - 1 1/8 inch Sensor Kit w/60T gear - 1 3/8 inch Sensor Kit w/60T gear - 1 5/8 inch Sensor Kit w/30T gear - 5/8 inch Sensor Kit w/30T gear - 7/8 inch Sensor Kit w/30T gear - 1 1/8 inch Sensor Kit w/30T gear - 1 3/8 inch Sensor Kit w/30T gear - 1 5/8 inch Quadrature Ring Kit - 5/8 inch Quadrature Ring Kit - 7/8 inch

Description

Magnetic Pickup, Threaded Magnetic Pickup, Smooth Magnetic Pickup, Explosion Proof

Proximity Sensor, intrinsically save with amp

Proximity Sensor, 3-wire Encoder, 10v, 600 PPR Encoder, 10v, 1200 PPR

Flange Ring only, 56C, for SM5XP sensor

Description

Gear, 60T, 5/8 inch Gear, 60T, 7/8 inch Gear, S0T, 1 1/8 inch Gear, S0T, 1 3/8 inch Gear, S0T, 1 5/8 inch Sprocket, 20T, 1/4 inch Gear, 30T, 5/8 inch Gear, 30T 7/8 inch Gear, 30T, 1 1/8 inch Gear, 30T, 1 3/8 inch Gear, 30T, 1 5/8 inch

Page 123 read from a scan by OCR; it may hold reading errors

APPENDIX B - FORMULAS B APPENDIX B - FORMULAS B

INTRODUCTION

This appendix contains the actual formulas used to calculate M-Drive Speed Control values, and is divided into two sections. Symbols defines each symbol used by these formulas, and Speed Control Formulas provides 3 methods of calculating Speed Control Equations for Master, Follower and Auxiliary Reference Frequency Formats.

INTRODUCTION

This appendix contains the actual formulas used to calculate M-Drive Speed Control values, and is divided into two sections. Symbols defines each symbol used by these formulas, and Speed Control Formulas provides 3 methods of calculating Speed Control Equations for Master, Follower and Auxiliary Reference Frequency Formats.

SYMBOLS SYMBOLS SP Setpoint SP Setpoint ; ; ; ; EU Engineering Unit (Maximum Setpoint) EU Engineering Unit (Maximum Setpoint) Rf RPM of Subject Shaft Rf RPM of Subject Shaft Rfmx Maximum Rf Rfmx Maximum Rf ; Pf PPR of gear on Subject Shaft Pf PPR of gear on Subject Shaft Re RPM of External Reference Shaft Re RPM of External Reference Shaft Remx Maximum Re Remx Maximum Re Pe PPR of gear on External Reference Shaft Pe PPR of gear on External Reference Shaft Ra RPM of Auxilliary Reference Shaft Ra RPM of Auxiliary Reference Shaft Ramx Maximum Ra Ramx Maximum Ra _ Pa PPR of gear on Auxiliary Reference Shaft Pa PPR of gear on Auxilliary Reference Shaft Cc Offset constant Cc Offset constant ER External Reference Frequency ER External Reference Frequency FB Feedback Frequency FB Feedback Frequency AX Auxilliary Reference Frequency AX Auxilliary Reference Frequency

SPEED CONTROL FORMULAS

These equations are stated using three different methods: General, Hz, and RPM.

MASTER FORMAT

SPEED CONTROL FORMULAS

These equations are stated using three different methods: General, Hz, and RPM.

MASTER FORMAT

GENERAL: P =_Rf GENERAL: SP =_Rf EU Rfmx EU Rmx

Hz: SP * Rimx*Pf = FB Hz: SP * Rimx*Pf = FB EU 60 EU 60

RPM: SP * Rimx = Rf RPM: SP * Rimx = Rf EU EU

Page B-1

Page B-1

Page 124 read from a scan by OCR; it may hold reading errors

FOLLOWER FORMAT FOLLOWER FORMAT

GENERAL: SP* Re = Rf GENERAL: SP* Re = Rf EU Remx Rfmx EU Remx Rfmx

Hz: SP * ER*Rfmx*Pf = FB Hz: SP * ER*Rfmx*Pf = FB EU Remx*Pe EU Remx*Pe

RPM: SP * Re*Rfimx = Rf RPM: SP * Re*Rfmx = Rf EU Remx EU Remx

AUXILIARY REFERENCE FREQUENCY FORMAT AUXILIARY REFERENCE FREQUENCY FORMAT

GENERAL: SP* Re + Ra + Cc = RE GENERAL: SP* Re + Ra + (ei = RE EU Remx Ramx (Rimx*Pf)/60 Rimx EU Remx Ramx (Rimx*Pf)/60 Rimx

Hz: SP * ER*Rfmx*Pf + AX*Rimx*Pf + C = FB Hz: SP * ER*Rfmx*Pf + AX*Rimx*Pf + C = FB EU Remx*Pe Ramx*Pa EU Remx*Pe Ramx*Pa

RPM: SP * Re*Rimx + Ra*Rfimx + CC = Rt RPM: SP * Re*Rfmx + Ra*Rimx + _ C = Rf EU Remx Ramx = Pf/60 EU -Remx Ramx = Pf/60

Page B-2 Page B-2

Page 125 read from a scan by OCR; it may hold reading errors

APPENDIX C - CODE LIST (COMPLETE TEXT) Cc

INTRODUCTION

This appendix provides in numeric order a complete list of all control and monitor code select variables present in the M-Drive. The Code Select Procedure is also provided.

CODE SELECT PROCEDURE

The Code Select Procedure indicates how the operator gains access to the various control and monitor parameters through their unique identification codes. Opening the lower door on the front of the M-Drive keypad exposes the programming keypad.

Accessing the desired parameter is a simple procedure:

1) Press the Code Select Key. 2) Enter the desired parameter code number. 3) Press the Enter Key.

At this point, the two digit code is displayed in the lower display window and the existing parameter value is displayed in the upper four digit display window. in addition, the keypad is enabled for changing the desired parameter. To make a change, simply enter the new value and press the Enter Key.

Page C-1

APPENDIX C - CODE LIST (COMPLETE TEXT) Cc

INTRODUCTION

This appendix provides in numeric order a complete list of all control and monitor code select variables present in the M-Drive. The Code Select Procedure is also provided.

CODE SELECT PROCEDURE

The Code Select Procedure indicates how the operator gains access to the various control and monitor parameters through their unique identification codes. Opening the lower door on the front of the M-Drive keypad exposes the programming keypad.

Accessing the desired parameter is a simple procedure:

1) Press the Code Select Key. 2) Enter the desired parameter code number. 3) Press the Enter Key.

At this point, the two digit code is displayed in the lower display window and the existing parameter value is displayed in the upper four digit display window. in addition, the keypad is enabled for changing the desired parameter. To make a change, simply enter the new value and press the Enter Key.

Page C-1

Page 126 read from a scan by OCR; it may hold reading errors

1 - PRIMARY SETPOINT 1

Primary Setpoint 1 is invoked when the M-Drive is in the Primary Scaling Mode and the Primary Setpoint Select switch input is open. This setpoint is the absolute setpoint if the Primary Scaling Mode is programmed as a Master Scaling Mode. This setpoint is the multiplier ratio if the Primary Scaling Mode is programmed for Follower Scaling Mode.

This parameter is entered in engineering units. The decimal point location and scaling for this entry is set up through the Scaling procedure (Code Select 20).

2 - PRIMARY SETPOINT 2

Primary Setpoint 2 is invoked when the M-Drive is in the Primary Scaling Mode and the Primary Setpoint Select switch is closed. This setpoint is the absolute setpoint if the Primary Scaling Mode is programmed as a Master Scaling Mode. This setpoint is the multiplier ratio if the Primary Control Mode is programmed for Follower Scaling Mode.

3 - SECONDARY SETPOINT 1 Secondary Setpoint 1 is invoked when the M-Drive is in the Secondary Scaling Mode and the Secondary Setpoint select switch is open. This setpoint is the absolute setpoint for the Master Scaling Mode and the multiplier ratio for the Follower Scaling Mode.

4 - SECONDARY SETPOINT 2 Secondary Setpoint 2 is invoked when the M-Drive is in the Secondary Scaling Mode and the Secondary Setpoint select switch input is closed. This setpoint is the absolute setpoint for the Master Scaling Mode and the multiplier ratio for the Follower Scaling Mode.

5 - JOG SETPOINT

This is the setpoint source for Jog operation. This entry is always entered in RPMs.

6 - OUTPUT SETPOINT Output Setpoint is the setpoint source when the Direct Scaling is invoked by either the

Primary or Secondary Scaling Modes. This setpoint directly sets the output fevel, in percent, of the Drive Output to the motor.

Page C-2

1 - PRIMARY SETPOINT 1

Primary Setpoint 1 is invoked when the M-Drive is in the Primary Scaling Mode and the Primary Setpoint Select switch input is open. This setpoint is the absolute setpoint if the Primary Scaling Mode is programmed as a Master Scaling Mode. This setpoint is the multiplier ratio if the Primary Scaling Mode is programmed for Follower Scaling Mode.

This parameter is entered in engineering units. The decimal point location and scaling for this entry is set up through the Scaling procedure (Code Select 20).

2 - PRIMARY SETPOINT 2

Primary Setpoint 2 is invoked when the M-Drive is in the Primary Scaling Mode and the Primary Setpoint Select switch is closed. This setpoint is the absolute setpoint if the Primary Scaling Mode is programmed as a Master Scaling Mode. This setpoint is the multiplier ratio if the Primary Control Mode is programmed for Follower Scaling Mode.

3 - SECONDARY SETPOINT 141

Secondary Setpoint 1 is invoked when the M-Drive is in the Secondary Scaling Mode and the Secondary Setpoint select switch is open. This setpoint is the absolute setpoint for the Master Scaling Mode and the multiplier ratio for the Follower Scaling Mode.

4 - SECONDARY SETPOINT 2

Secondary Setpoint 2 is invoked when the M-Drive is in the Secondary Scaling Mode and the Secondary Setpoint select switch input is closed. This setpoint is the absolute setpoint for the Master Scaling Mode and the multiplier ratio for the Follower Scaling Mode.

5 - JOG SETPOINT

This is the setpoint source for Jog operation. This entry is always entered in RPMs.

6 - OUTPUT SETPOINT

Output Setpoint is the setpoint source when the Direct Scaling is invoked by either the Primary or Secondary Scaling Modes. This setpoint directly sets the output fevel, in percent, of the Drive Output to the motor.

Page C-2

Page 127 read from a scan by OCR; it may hold reading errors

10 - MINIMUM LIMIT This parameter sets the minimum level of RPMs for operation. Although it is possible to enter a setpoint below this level, the control will always attempt to maintain a speed at or above the minimum limit except to recover position error.

11 - MAXIMUM LIMIT

This parameter sets the maximum level of RPMs for operation. Although it is possible to enter a setpoint above this limit, the control will always attempt to maintain a speed at or below the maximum limit except to recover position error.

12 - LOW ALARM

This parameter sets the RPM level at which the Low Alarm output is energized. The output will energize when the feedback RPMs are at or below this level.

13 - HIGH ALARM

This parameter sets the RPM level at which the High Alarm output is energized. The output will energize when the feedback is at or above this RPM level.

14 - ERROR ALARM 1 - RAMPED ERROR This parameter establishes the error band (Ramped Reference minus feedback) in

RPMs at which the Error Alarm 1 output is energized. Any positive or negative error at or above this level will energizes the output.

15 - ERROR ALARM 2 - SCALED ERROR

This parameter establishes the error band (Scaled Reference minus feedback) in RPMs at which the Error Alarm 2 output is energized. Any positive or negative error at or above this level will energize the output.

16 - ACCELERATION TIME

Acceleration Time determines the acceleration rate of the setpoint. The number entered is the amount of time required to increase the setpoint from 0 to 2000 RPMs.

Page C-3

10 - MINIMUM LIMIT This parameter sets the minimum level of RPMs for operation. Although it is possible to enter a setpoint below this level, the control will always attempt to maintain a speed at or above the minimum limit except to recover position error.

11 - MAXIMUM LIMIT

This parameter sets the maximum level of RPMs for operation. Although it is possible to enter a setpoint above this limit, the control will always attempt to maintain a speed at or below the maximum limit except to recover position error.

12 - LOW ALARM

This parameter sets the RPM level at which the Low Alarm output is energized. The output will energize when the feedback RPMs are at or below this level.

13 - HIGH ALARM

This parameter sets the RPM level at which the High Alarm output is energized. The output will energize when the feedback is at or above this RPM level.

14 - ERROR ALARM 1 - RAMPED ERROR This parameter establishes the error band (Ramped Reference minus feedback) in

RPMs at which the Error Alarm 1 output is energized. Any positive or negative error at or above this level will energizes the output.

15 - ERROR ALARM 2 - SCALED ERROR

This parameter establishes the error band (Scaled Reference minus feedback) in RPMs at which the Error Alarm 2 output is energized. Any positive or negative error at or above this level will energize the output.

16 - ACCELERATION TIME

Acceleration Time determines the acceleration rate of the setpoint. The number entered is the amount of time required to increase the setpoint from 0 to 2000 RPMs.

Page C-3

Page 128 read from a scan by OCR; it may hold reading errors

17 DECELERATION TIME Deceleration Time determines the deceleration rate of the setpoint. The number entered is the amount of time (in seconds) required to decrease the setpoint from 2000 to 0 RPMs.

18 - LAG PULSE LIMIT The Lag Pulse Limit sets a maximum pulse error count for the difference between the idealized feedback pulses minus the Feedback pulses. It may not always be desirable to recover all of the position error lag. Set this parameter to the desired lag pulse limit.

19 - LEAD PULSE LIMIT The Lead Pulse Limit sets a maximum pulse error count when the Feedback pulses exceed the idealized feedback pulse count. Set this parameter to the desired lead pulse limit.

20 - ENGINEERING UNITS (PRIMARY SETPOINT) This is the desired Engineering Units scaling number for the primary Scaling Mode setpoint.

21 - ENGINEERING UNITS (SECONDARY SETPOINT) This is the desired Engineering Units scaling number for the Secondary Scaling Mode setpoint.

22 - ENGINEERING UNITS (PRIMARY DISPLAY)

This is the desired Engineering Units scaling number for the Primary Scaling Mode display.

23 - ENGINEERING UNITS (SECONDARY DISPLAY)

This is the desired Engineering Units scaling number for the Secondary Scaling Mode display.

29 - RECOVERY MULTIPLIER The Recover Multiplier determines the rate at which the pulse error is reduced to zero.

This parameter muttiplied by the pulse error count is the number by which the speed setpoint is adjusted every 100 milliseconds.

Page C-4

17 DECELERATION TIME Deceleration Time determines the deceleration rate of the setpoint. The number entered is the amount of time (in seconds) required to decrease the setpoint from 2000 to 0 RPMs.

18 - LAG PULSE LIMIT The Lag Pulse Limit sets a maximum pulse error count for the difference between the idealized feedback pulses minus the Feedback pulses. It may not always be desirable to recover all of the position error lag. Set this parameter to the desired lag pulse limit.

19 - LEAD PULSE LIMIT The Lead Pulse Limit sets a maximum pulse error count when the Feedback pulses exceed the idealized feedback pulse count. Set this parameter to the desired lead pulse limit.

20 - ENGINEERING UNITS (PRIMARY SETPOINT) This is the desired Engineering Units scaling number for the primary Scaling Mode setpoint.

21 - ENGINEERING UNITS (SECONDARY SETPOINT) This is the desired Engineering Units scaling number for the Secondary Scaling Mode setpoint.

22 - ENGINEERING UNITS (PRIMARY DISPLAY)

This is the desired Engineering Units scaling number for the Primary Scaling Mode display.

23 - ENGINEERING UNITS (SECONDARY DISPLAY)

This is the desired Engineering Units scaling number for the Secondary Scaling Mode display.

29 - RECOVERY MULTIPLIER The Recover Multiplier determines the rate at which the pulse error is reduced to zero.

This parameter muttiplied by the pulse error count is the number by which the speed setpoint is adjusted every 100 milliseconds.

Page C-4

Page 129 read from a scan by OCR; it may hold reading errors

30 - PPR (EXTERNAL REFERENCE INPUT)

This number should be set for the Pulses per Revolution of the External Reference Frequency Input.

31 - PPR (FEEDBACK INPUT)

This number should be set for the Pulses per Revolution of the Feedback Frequency Input.

32 - PPR (AUXILIARY INPUT)

This number shouid be set for the Pulses per Revolution of the Auxiliary Frequency input if present.

33 - MAX RPM (EXTERNAL REFERENCE INPUT: PRIMARY MODE)

This parameter should be set for the maximum RPMs of the External Reference Frequency Input when operating in the Primary Scaling Mode.

34 - MAX RPM (FEEDBACK: PRIMARY MODE)

This parameter represents the maximum RPMs of the Feedback Frequency Input when operating the Primary Scaling Mode.

35 - MAX RPM (AUXILIARY INPUT: PRIMARY MODE)

This parameter represents the maximum RPMs of the Auxiliary Frequency Input when operating in the Primary Scaling Mode.

36 - MAX RPM (EXTERNAL REFERENCE INPUT: SECONDARY MODE)

This parameter represents the maximum RPMs of the External Reference Input when operating in the Secondary Scaling Mode.

37 - MAX RPM (FEEDBACK: SECONDARY MODE)

This parameter represents the maximum RPMs of the Feedback Frequency input when operating in the Secondary Scaling Mode.

Page C-5

30 - PPR (EXTERNAL REFERENCE INPUT)

This number should be set for the Pulses per Revolution of the External Reference Frequency Input.

31 - PPR (FEEDBACK INPUT)

This number should be set for the Pulses per Revolution of the Feedback Frequency Input.

32 - PPR (AUXILIARY INPUT)

This number shouid be set for the Pulses per Revolution of the Auxiliary Frequency input if present.

33 - MAX RPM (EXTERNAL REFERENCE INPUT: PRIMARY MODE)

This parameter should be set for the maximum RPMs of the External Reference Frequency Input when operating in the Primary Scaling Mode.

34 - MAX RPM (FEEDBACK: PRIMARY MODE)

This parameter represents the maximum RPMs of the Feedback Frequency Input when operating the Primary Scaling Mode.

35 - MAX RPM (AUXILIARY INPUT: PRIMARY MODE)

This parameter represents the maximum RPMs of the Auxiliary Frequency Input when operating in the Primary Scaling Mode.

36 - MAX RPM (EXTERNAL REFERENCE INPUT: SECONDARY MODE)

This parameter represents the maximum RPMs of the External Reference Input when operating in the Secondary Scaling Mode.

37 - MAX RPM (FEEDBACK: SECONDARY MODE)

This parameter represents the maximum RPMs of the Feedback Frequency input when operating in the Secondary Scaling Mode.

Page C-5

Page 130 read from a scan by OCR; it may hold reading errors

38 - MAX RPM (AUXILIARY INPUT: SECONDARY MODE)

This parameter represents the maximum RPMs of the Auxiliary Frequency Input when operating in the Secondary Scaling Mode.

40 - TACH

Tach is the feedback displayed in scaled engineering units. The feedback input is read by the M-Drive every 10 milliseconds. The readings are summed and averaged for one second before displaying.

41 - EXTERNAL REFERENCE INPUT

The External Reference Input displays the frequency of this input in hertz (pulses per second). The number displayed is not averaged. It represents the frequency calculation from the prior 10 milliseconds before the display update. Because it is not averaged over the display update period, it appears less stable than the Tach display due to sensor irregularities or other system dynamic errors.

Note: Codes 41, 42, 43, 45 and 46 may contain numbers larger than 9999. When this occurs, the value is displayed differently. For example, a "10.00." display indicates 10,000 hertz.

42 - AUXILIARY FREQUENCY INPUT

The Auxiliary Frequency Input displays the frequency of this input in hertz (pulses per second). This display is not averaged. It is a 10 millisecond number. See Note above.

43 - FEEDBACK FREQUENCY INPUT

The Feedback Frequency Input displays the feedback input in hertz (pulses per second). The number displayed is not averaged over the display period. It isa 10 millisecond calculated number. See Note above.

44 - DEVIATION (ERROR)

The Deviation display is the difference between the setpoint and the feedback

(Ramped Reference (46) - Feedback (43)). It is also a 10 millisecond calculated variable.

Page C-6

38 - MAX RPM (AUXILIARY INPUT: SECONDARY MODE)

This parameter represents the maximum RPMs of the Auxiliary Frequency Input when operating in the Secondary Scaling Mode.

40 - TACH

Tach is the feedback displayed in scaled engineering units. The feedback input is read by the M-Drive every 10 milliseconds. The readings are summed and averaged for one second before displaying.

41 - EXTERNAL REFERENCE INPUT

The External Reference Input displays the frequency of this input in hertz (pulses per second). The number displayed is not averaged. It represents the frequency calculation from the prior 10 milliseconds before the display update. Because it is not averaged over the display update period, it appears less stable than the Tach display due to sensor irregularities or other system dynamic errors.

Note: Codes 41, 42, 43, 45 and 46 may contain numbers larger than 9999. When this occurs, the value is displayed differently. For example, a "10.00." display indicates 10,000 hertz.

42 - AUXILIARY FREQUENCY INPUT

The Auxiliary Frequency Input displays the frequency of this input in hertz (pulses per second). This display is not averaged. It is a 10 millisecond number. See Note above.

43 - FEEDBACK FREQUENCY INPUT

The Feedback Frequency Input displays the feedback input in hertz (pulses per second). The number displayed is not averaged over the display period. Itis a 10 millisecond calculated number. See Note above.

44 - DEVIATION (ERROR)

The Deviation display is the difference between the setpoint and the feedback (Ramped Reference (46) - Feedback (43)). It is also a 10 millisecond calculated variable.