Page 21 read from a scan by OCR; it may hold reading errors

There are two function keys on the Operator Keypad: Set Speed and Tach. The Set Speed key is used to enable the M-Drive for entry or monitoring of the setpoint (if in Master Mode) or the ratio (if in Follower Mode). (The Master/Follower Mode is determined by the state of the Primary/Secondary control input-J4 pin 3.) The setpoint selection process is described in detail in the Control Inputs section of this chapter.

After the Set Speed key is pressed, the numeric portion of the Operator Keypad is enabled for setpoint entry. The operator enters the setpoint or ratio in scaled engineering units. The M-Drive accepts the new parameter when the Enter key is pressed. Errors made during the entry process can be erased with the Clear Key. The decimal point location is pre-determined by the M-Drive through the scaling parameter entry procedure and need not be entered by the operator.

An alternative to the Set Speed and Numeric entry procedure for changing the Setpoint or ratio involves the use of the scroll keys. The Up and Down scroll keys are always enabled for changing the active setpoint or ratio. (One Exception: Keypad Lockout may disable selected setpoints. See Keypad Lockout discussion under Control Inputs section of this chapter.) The active setpoint will be altered regardless of which parameter is being displayed on the Operator Keypad. The scroll keys are slow scroll only and are intended for fine adjustments to the setpoint.

The second function key on the Operator Keypad is the Tach key. When pressed the display will indicate the feedback or the ratio of feedback to external reference in engineering units. This feedback display is averaged and updated every one second.

Page 1-9

There are two function keys on the Operator Keypad: Set Speed and Tach. The Set Speed key is used to enable the M-Drive for entry or monitoring of the setpoint (jf in Master Mode) or the ratio (if in Follower Mode). (The Master/Follower Mode is determined by the state of the Primary/Secondary control input--J4 pin 3.) The setpoint selection process is described in detail in the Control Inputs section of this chapter.

After the Set Speed key is pressed, the numeric portion of the Operator Keypad is enabled for setpoint entry. The operator enters the setpoint or ratio in scaled engineering units. The M-Drive accepts the new parameter when the Enter key is pressed. Errors made during the entry process can be erased with the Clear Key. The decimal point location is pre-determined by the M-Drive through the scaling parameter entry procedure and need not be entered by the operator.

An alternative to the Set Speed and Numeric entry procedure for changing the Setpoint or ratio involves the use of the scroll keys. The Up and Down scroll keys are always enabled for changing the active setpoint or ratio. (One Exception: Keypad Lockout may disable selected setpoints. See Keypad Lockout discussion under Control Inputs section of this chapter.) The active setpoint will be altered regardless of which parameter is being displayed on the Operator Keypad. The scroll keys are slow scroll only and are intended for fine adjustments to the setpoint.

The second function key on the Operator Keypad is the Tach key. When pressed the display will indicate the feedback or the ratio of feedback to external reference in engineering units. This feedback display is averaged and updated every one second.

Page 1-9

Page 22 read from a scan by OCR; it may hold reading errors

FACTORY DEFAULT SCALING FACTORY DEFAULT SCALING

When shipped from the factory, the M-Drive is scaled for the following settings: When shipped from the factory, the M-Drive is scaled for the following settings: Lead Motor: 60 tooth gears Lead Motor: 60 tooth gears 2000 RPM maximum speed 2000 RPM maximum speed Slave Motor: 60 tooth gears Slave Motor: 60 tooth gears 2000 RPM maximum speed 2000 RPM maximum speed Master Format: | Speed setpoint and Tach are scaled in RPM. Master Format: Speed setpoint and Tach are scaled in RPM. Follower Format: Ratio Setpoint is scaled so that a 1.000 setting causes the Follower Format: Ratio Setpoint is scaled so that a 1.000 setting causes the slave motor to rotate at the same RPM as the lead motor. slave motor to rotate at the same RPM as the lead motor. Tach is scaled to indicate 1.000 when the RPM of the slave Tach is scaled to indicate 1.000 when the RPM of the slave motor is equal to the RPM of the master motor. motor is equal to the RPM of the master motor. Although the default scaling listed above may not be the final scaling used for your Although the default scaling listed above may not be the final scaling used for your application, it is recommended that the system be first started using these default application, it is recommended that the system be first started using these default parameters. This facilitates ease of start up tasks when verifying details such as wiring parameters. This facilitates ease of start up tasks when verifying details such as wiring and logic. and logic. For details concerning rescaling the M-Drive, refer to the Programming chapter in this For details concerning rescaling the M-Drive, refer to the Programming chapter in this manual. manual.

Page 1-10 Page 1-10

Page 23 read from a scan by OCR; it may hold reading errors

CONFIGURATION 2

INTRODUCTION

This chapter contains the information required to hardware configure the M-Drive for purposes of electrical compatibility. The procedures within this chapter should be completed prior to installing the M-Drive. Note that these procedures do not require power to complete.

Before proceeding with the configuration procedure, read the information below to determine if the factory default configuration is appropriate for your application. In most cases, it will not be necessary to reconfigure the M-Drive.

This chapter is divided into 3 sections: Frequency Inputs, Analog Input/Output (Optional), and Power Voltage Select. Figure 2-1 below illustrates the location for the CPU board and the Power Drive board.

Power CPU Supply | - - "_ Board Board ~~ «A

Figure 2-1: M-Drive Board Location (Rear View)

Page 2-1

CONFIGURATION 2

INTRODUCTION

This chapter contains the information required to hardware configure the M-Drive for purposes of electrical compatibility. The procedures within this chapter should be completed prior to installing the M-Drive. Note that these procedures do not require power to complete.

Before proceeding with the configuration procedure, read the information below to determine if the factory default configuration is appropriate for your application. In most cases, it will not be necessary to reconfigure the M-Drive.

This chapter is divided into 3 sections: Frequency Inputs, Analog Input/Output (Optional), and Power Voltage Select. Figure 2-1 below illustrates the location for the CPU board and the Power Drive board.

Power CPU Supply - L - ~" Board Board ae

Figure 2-1: M-Drive Board Location (Rear View)

Page 2-1

Page 24 read from a scan by OCR; it may hold reading errors

FREQUENCY INPUTS

The Frequency Input select jumpers are located on the M-Drive CPU board. To gain access to this board, remove (pull off) the screw headers from the rear terminal connecters. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out approximately 1 inch to expose the Frequency Input select jumpers on the top component side of the board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Frequency input select jumper configures the External Reference, Feedback and Auxiliary Frequency Inputs for either zero crossing (magnetic pickup) or open-collector (proximity and encoder) signal compatibility. Table 2-1 below illustrates which jumpers are used to configure these three inputs. For example, a jumper shunted between pins 7 and 8 configures the Feedback Input for Zero Crossing.

Open Collector Zero Crossing (Default) External Reference 1-2 3-4 Feedback 5-6 7-8 Auxiliary Input 9-10 11-12

Table 2-1: Frequency Input Selections

Figure 2-2 below illustrates 2 possible configurations for the Frequency Input select jumpers: Figure 2-2a illustrates all three inputs configured for Open-Collectors, while Figure 2-2b illustrates all three inputs configured for Zero Crossing (Default).

J4 J4

LJ J

J2 A: Open-Collector J2 B: Zero Crossing (Default)

Figure 2-2: Frequency Input Options Page 2-2

FREQUENCY INPUTS

The Frequency Input select jumpers are located on the M-Drive CPU board. To gain access to this board, remove (pull off) the screw headers from the rear terminal connecters. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out approximately 1 inch to expose the Frequency Input select jumpers on the top component side of the board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Frequency input select jumper configures the External Reference, Feedback and Auxiliary Frequency Inputs for either zero crossing (magnetic pickup) or open-collector (proximity and encoder) signal compatibility. Table 2-1 below illustrates which jumpers are used to configure these three inputs. For example, a jumper shunted between pins 7 and 8 configures the Feedback Input for Zero Crossing.

Open Collector Zero Crossing (Default) External Reference 1-2 3-4 Feedback 5-6 7-8 Auxiliary Input 9-10 11-12

Table 2-1: Frequency Input Selections

Figure 2-2 below illustrates 2 possible configurations for the Frequency Input select jumpers: Figure 2-2a illustrates all three inputs configured for Open-Collectors, while Figure 2-2b illustrates all three inputs configured for Zero Crossing (Default).

J4 J4

LJ J

J2 A: Open-Collector J2 B: Zero Crossing (Default)

Figure 2-2: Frequency Input Options Page 2-2

Page 25 read from a scan by OCR; it may hold reading errors

ANALOG INPUT/OUTPUT (OPTIONAL)

The Analog Input/Output Option board mounts on the lower rear component side of the CPU board. To field install this option board, first remove the screw barrier connectors on the rear of the M-Drive. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out to expose the two 12-position male connectors used to mount the Analog Input/Output Option board (lower rear component side of CPU board). Plug the two 12-position female connectors on the solder side of the Analog Input/Output Option board into the male connectors of the CPU board. A nylon standoff is provided for mechanically mounting the option board. The option board should be mounted with the selector shunts facing the rear of the CPU board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Analog Input/Output select jumper configures the analog input and output for either a 10 volt DC level or a 4 to 20 mA current level. Table 2-2 below illustrates which jumpers are used to configure the input and output. For example, a jumper shunted between pins 9 and 10 configures the analog output for + 10 VDC. *

0 to 10 vDC 4 to 20 mA (Default) 1 - 2 and 3 - 4 and Analog Input 5-6 7-8 * Analog Output 9 - 10 11 - 12

Table 2-2 Analog Input/Output Selections

* Note: The analog output level will range from -10 volts to + 10 volts when patched to variables with positive and negative values. It will range from 0 to +10 volts for variables with positive values only.

Page 2-3

ANALOG INPUT/OUTPUT (OPTIONAL)

The Analog Input/Output Option board mounts on the lower rear component side of the CPU board. To field install this option board, first remove the screw barrier connectors on the rear of the M-Drive. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out to expose the two 12-position male connectors used to mount the Analog Input/Output Option board (lower rear component side of CPU board). Plug the two 12-position female connectors on the solder side of the Analog Input/Output Option board into the male connectors of the CPU board. A nylon standoff is provided for mechanically mounting the option board. The option board should be mounted with the selector shunts facing the rear of the CPU board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Analog Input/Output select jumper configures the analog input and output for either a 10 volt DC level or a 4 to 20 mA current level. Table 2-2 below illustrates which jumpers are used to configure the input and output. For example, a jumper shunted between pins 9 and 10 configures the analog output for + 10 VDC. *

0 to 10 VDC 4 to 20 mA (Default) 1 - 2 and 3 - 4 and Analog Input 5-6 7-8 * Analog Output 9 - 10 11 - 12

Table 2-2 Analog Input/Output Selections

* Note: The analog output level will range from -10 volts to + 10 volts when patched to variables with positive and negative values. It will range from 0 to +10 volts for variables with positive values only.

Page 2-3

Page 26 read from a scan by OCR; it may hold reading errors

Figure 2-3 below illustrates 2 possible configurations for the Analog Input/Output select jumpers. Figure 2-3a illustrates both the input and output configured for 0-10 VDC (default). Figure 2-3b illustrates both the input and output configured for 4-20 mA.

Analog

Analog Output 11 fo] ° 12 11 12

A: QO to 10 vbDCc B: 4 to 20 mA (Default)

Figure 2-3: Analog Input/Output Options

CAUTION To prevent possible equipment damage, the upper two shunts configuring the Analog Input must always move as a pair. That is, the Analog Input shunts must connect either positions 1-2 and 5-6 or connect positions 3-4 and 7-8.

POWER VOLTAGE SELECT

The Power Voltage Select switch is located on the bottom of the Power Drive board, just above the fuse.

This switch selects for either 115 VAC (Default) or 230 VAC power.

The switch is clearly marked for the two available positions.

Page 2-4

Figure 2-3 below illustrates 2 possible configurations for the Analog Input/Output select jumpers. Figure 2-3a illustrates both the input and output configured for 0-10 VDC (default). Figure 2-3b illustrates both the input and output configured for 4-20 mA.

Analog

Analog Output 11 fo] ° 12 11 12

A: QO to 10 vbDCc B: 4 to 20 mA (Default)

Figure 2-3: Analog Input/Output Options

CAUTION To prevent possible equipment damage, the upper two shunts configuring the Analog Input must always move as a pair. That is, the Analog Input shunts must connect either positions 1-2 and 5-6 or connect positions 3-4 and 7-8.

POWER VOLTAGE SELECT

The Power Voltage Select switch is located on the bottom of the Power Drive board, just above the fuse.

This switch selects for either 115 VAC (Default) or 230 VAC power.

The switch is clearly marked for the two available positions.

Page 2-4

Page 27

INSTALLATION

3

INTRODUCTION This chapter contains the information and procedures required to complete the initial installation and wiring for the M-Drive. All pages within this chapter must be read to ensure that the appropriate decisions are made prior to the final wiring of the M-Drive. Note to Electricians installing the M-Drive:

3

- Class G branch circuit fuses rated 250V, 15A shall be provided in the end application. - Motor overload protection shall be provided in the end installation in accordance with the NEC. - This drive does not provide over-temperature sensing. The installation of this motor control must conform to area and local electrical codes. For information, refer to the National Electrical Code (NEC) Article 430 published by the National Fire Protection Association, or the Canadian Electrical Code (CEC). Refer to local codes as applicable.

WARNING Hazardous voltages are present during certain installation procedures. Therefore, the M-Drive should only be installed by qualified electrical maintenance personnel.

This chapter is organized into 2 distinct sections: MOUNTING WIRING The Mounting section provides drawings and instructions for mounting the M-Drive in an enclosure. The Wiring section summarizes the wiring connections for the M-Drive.

Page 3-1

Page 28 read from a scan by OCR; it may hold reading errors

MOUNTING INTRODUCTION

The M-Drive is packaged in a 1/2 DIN Vertical instrument enclo- sure intended for door mounting in a NEMA enclosure. Figure 3-1 illustrates an installed M-Drive with dimensions.

Note: Prior to mounting the M-Drive in your enclosure, complete the Configuration Procedures outlined in Chapter 2. The configuration shunts and switches may be less accessible after the device is installed in the enclosure.

DOOR PANEL

\, J

* To rear of Connectors from Front Panel

Figure 3-1: M-Drive Dimensions

Page 3-2

MOUNTING INTRODUCTION

The M-Drive is packaged in a 1/2 DIN Vertical instrument enclo- sure intended for door mounting in a NEMA enclosure. Figure 3-1 illustrates an installed M-Drive with dimensions.

Note: Prior to mounting the M-Drive in your enclosure, complete the Configuration Procedures outlined in Chapter 2. The configuration shunts and switches may be less accessible after the device is installed in the enclosure.

DOOR PANEL

\, J

* To rear of Connectors from Front Panel

Figure 3-1: M-Drive Dimensions

Page 3-2

Page 29 read from a scan by OCR; it may hold reading errors

MOUNTING PROCEDURE

Mount the M-Drive into your enclosure according to the following procedure:

MOUNTING PROCEDURE

Mount the M-Drive into your enclosure according to the following procedure:

Temperature: 0-55 degrees C (interior enclosure) Humidity: 0-90% non-condensing

Note: Allow adequate spacing between the M-Drive and other equipment to provide for proper heat convection. Placing the M-Drive too close to adjacent equipment could cause the interior ambient temperature to exceed 55 degrees C. Spacing requirements depend on air flow, enclosure construction and applied horsepower.

Determine the appropriate door or panel location and make the panel cutout per Figure 3-2 below. Allow adequate top and bottom room for mounting bracket.

Insert the M-Drive from the panel front up to the bezel or gasket. Connect the two mounting brackets from the rear of the M-Drive on the top and bottom.

Drive the mounting bracket screws onto the rear of the door or panel until the M-Drive is securely mounted. Mime

1 Bracket I a

Panel

Cutout 7.25" + .03'

] Mounting I L Bracket, - 3.65" +03"

Figure 3-2: Panel Cutout Dimensions Page 3-3

4. Ensure the mounting location meets the environmental conditions for the M-Drive: 1. Ensure the mounting location meets the environmental conditions for the M-Drive:

Temperature: 0-55 degrees C (interior enclosure) Humidity: 0-90% non-condensing

Note: Allow adequate spacing between the M-Drive and other equipment to provide for proper heat convection. Placing the M-Drive too close to adjacent equipment could cause the interior ambient temperature to exceed 55 degrees C. Spacing requirements depend on air flow, enclosure construction and applied horsepower.

Determine the appropriate door or panel location and make the panel cutout per Figure 3-2 below. Allow adequate top and bottom room for mounting bracket.

Insert the M-Drive from the panel front up to the bezel or gasket. Connect the two mounting brackets from the rear of the M-Drive on the top and bottom.

Drive the mounting bracket screws onto the rear of the door or panel until the M-Drive is securely mounted. Miountng

! Bracket I

NX

Panel

Cutout 7.25" + 03)

ya ~~

] Mounting I L Bracket, - 3.65" +03"

Figure 3-2: Panel Cutout Dimensions Page 3-3

Page 30 read from a scan by OCR; it may hold reading errors

WIRING INTRODUCTION The wiring portion of this chapter is divided into five sections:

1. Required Inputs

2. Required Outputs

3. Elective Inputs

4. Elective Outputs

5. Serial Communications

As the titles indicate, the decisions made during the Required sections are mandatory to obtain a properly installed M-Drive. The elective sections are completed at the discretion of the User.

The Serial Communications connections are discussed as a separate item in the fifth and final wiring section.

CAUTION

Where indicated, it is important to use shielded cable to minimize equipment malfunctions due to electrical noise. It is assumed throughout this manual that shields are terminated at the receiving end only.

Proper earth grounding of all electronic equipment is required for successful operation. it is recommended that all shield and chassis ground connections be made to an earth ground to provide proper noise immunity and grounding protection.

AC power wiring (J2) should be kept physically separated from other wiring on the M-Trim. Failure to do so could result in coupled electrical noise and subsequent M-Trim malfunction.

Inductive coils from relay, contactors, solenoids, etc. on the same AC power line or in the same enclosure should be suppressed with an RC network across the coil. Best results occur with resistance (r) values of 50 ohms and capacitance (c) values of 0.1 microfarads.

if excessive EMI noise exists on the AC power line, such as line notches or spikes, it may be required to install an AC line filter or isolation transformer to ensure proper operation.

Page 3-4

WIRING INTRODUCTION

The wiring portion of this chapter is divided into five sections:

Required Inputs Required Outputs Elective inputs

Elective Outputs

Serial Communications aAPoOn>

As the titles indicate, the decisions made during the Required sections are mandatory to obtain a properly installed M-Drive. The elective sections are completed at the discretion of the User.

The Serial Communications connections are discussed as a separate item in the fifth and final wiring section.

CAUTION

Where indicated, it is important to use shielded cable to minimize equipment malfunctions due to electrical noise. It is assumed throughout this manual that shields are terminated at the receiving end only.

Proper earth grounding of all electronic equipment is required for successful operation. it is recommended that all shield and chassis ground connections be made to an earth ground to provide proper noise immunity and grounding protection.

AC power wiring (J2) should be kept physically separated from other wiring on the M-Trim. Failure to do so could result in coupled electrical noise and subsequent M-Trim malfunction.

Inductive coils from relay, contactors, solenoids, etc. on the same AC power line or in the same enclosure should be suppressed with an RC network across the coil. Best results occur with resistance (r) values of 50 ohms and capacitance (c) values of 0.1 microfarads.

if excessive EMI noise exists on the AC power line, such as line notches or spikes, it may be required to install an AC line filter or isolation transformer to ensure proper operation.