Manual · Cooper
Factory standard for control cabinet construction, m-Pro400SE Fastening System
Manual8 pagesPDF 172 KB
Control cabinet construction standard for the CLECO m-Pro-400SE fastening system with STM12 and STMH.1 tightening modules and built-in nutrunners.
What this file really is
The old site listed this file as a manual for the Cooper STM12. Named as the STM12 user manual, but it is the control cabinet construction standard for the m-Pro-400SE fastening system; the STM12 has its own instruction manual (P1672E).
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
Setup and assembly instructions for building the control cabinet of an m-Pro-400SE fastening system: the station controller, STM12 tightening modules for built-in nutrunners 1BB to 4BB, STMH.1 modules for hand tools, transformers, cables and relays. It covers grounding and potential equalization, EMC measures, mounting each component, transformer rules, maximum cable lengths, separating hot and cold signal lines, and mounting the nutrunners and hand tools.
Its parts
- Establishment of earth and potential equalization
- Conducting EMC Measures
- Control cabinet measures
- Cables
- Mounting of built-in nutrunner and hand tools
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
CLECO factory standard P2054MA/EN (2011) for building the control cabinet of the m-Pro-400SE fastening system, which includes the STM12 tightening modules for built-in nutrunners. It covers grounding, EMC measures, mounting the station controller, tightening modules and transformers, and cable laying. It is not the STM12 instruction manual itself, which it lists as P1672E.
- What it is
- STM12: tightening module for CLECO series BB built-in nutrunners in the m-Pro-400SE system p. 6
- Mounting
- Two M6 screws on a galvanized, grounded nutrunner mounting plate p. 6
- Protective earth
- Connection XS1 pin 3 p. 6
- Mains filters
- Integrated; no extra filter measures needed p. 6
- Transformers
- Isolation transformers to IEC 742 or EN 60742, authorized by CLECO p. 6
- 3-phase supply
- Ground the transformer secondary neutral point p. 6
- Maximum cable length
- Built-in nutrunner and hand tools 50 m; hand tools without transformer 20 m; ARCNET 100 m p. 7
- Station controller earth
- m-Pro-400SE in the cabinet door, 1.5 qm protective earth on the rear connection p. 4
- Nutrunner plate earth
- >10 mm2 yellow/green earth line to the cabinet mounting plate p. 7
- Cabinet
- Closed steel-sheet control cabinet (IP54), galvanized unpainted mounting plate p. 5
- EMC class
- Class A device p. 5
- Related manuals
- P1672E for tightening modules STM12, STM34; P2037BA for the m-Pro-400SE p. 2
- Hand tool module
- STMH.1 for hand tools 18E…E… and 48E…E…, CLECO hand tools only p. 6
What this manual walks you through
- Earthing and potential equalization of all components p. 4
- EMC measures for the control cabinet p. 5
- Installing the m-Pro-400SE station controller p. 6
- Installing STM12 tightening modules p. 6
- Wiring transformers for tightening modules p. 6
- Laying hot and cold signal cables p. 7
- Mounting built-in nutrunners and hand tools p. 7
Good to know
- The system must not run without a protective earth attached. p. 4
- Operate only with the control cabinet closed. p. 5
- Use spark suppressors on relays, switching elements and valve coils. p. 7
- Only CLECO-authorized cables or cable types may be used. p. 7
- Class A device that may cause radio interference in residential areas. p. 5
Questions this manual answers
Where does the protective earth connect on an STM12?
At connection XS1 pin 3. p. 6
What is the maximum cable length for a CLECO built-in nutrunner?
50 m for built-in nutrunners and hand tools; 20 m for hand tools without a transformer. p. 7
Which nutrunners work with the STM12 tightening module?
Only CLECO series BB built-in nutrunners, 1BB... to 4BB.... p. 6
What transformer can feed an STM12?
An isolation transformer to IEC 742 or EN 60742 authorized by CLECO; on a 3-phase transformer the secondary neutral must be grounded. p. 6
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 1 part
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file