Page 31

SOLID STATE RELAYS 90mm 2 and 3 PHASE DIN-RAIL SSR

1

INPUT SPECIFICATIONS: Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type

OUTPUT SPECIFICATIONS: Model Number Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current per phase (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) l2t (60 Hz, Half-Cycle)

84130310 84130220 4-32 VDC 1.0 VDC 22 8.33 8.33 Zero Crossing

84130312 84130221 4-32 VDC 1.0 VDC 22 0.1 8.33 Random Turn-on

Three Phase 84130310 84130311 84130312

Two Phase 84130220 84130221 84130222

48-530 1200 .25 500 100 20 750 145 1.6 1000

48-530 1200 .25 500 100 25 750 145 1.6 1000

84130311 84130222 90-280 VAC 10 VAC 6 20 30 Zero Crossing

Units mA ms ms

Units Vrms Vpeak mArms mArms Arms Apeak Apeak Vpeak A2 sec

GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) Input/Output to ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range

All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2000 Vrms 8 pF 47 to 63 Hz

Notes: (1) At maximum input voltage. Input is regulated and current limited. (2) Do not apply continuously for over 1 minute. (3) At maximum line voltage, Ta = 25°C. (4) Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. (5) Mounted in vertical position on DIN-Rail. Free Air. Derated by 27.3 mA/°C to 80°C. (6) Non-repetitive 60 Hz, resistive load, Ta = 25°C. (7) Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. (8) At maximum rated current. (9) Limited to 1 mA for 1 second, Ta = 25°C.

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/27

Page 32

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/28

Page 33

SOLID STATE RELAY ACCESSORIES THERMAL PADS

HSP1 Series:

1

HSP3 Series:

Single Phase

Three Phase GAO and GA3

HSP1 for Single Phase Relay. HSP3 for 3 phase GAO Series and GA3 Series. Sold in multiples of 25 (1 package) per part number. Thermstrate is a registered Trademark of Power Devices, Inc.

®

Solid State Relay Cover FEATURES: Snaps onto Crouzet Single Phase SSRs Provides “Finger Safe Operation” of SSRs Made of High Impact, Flame Retardant Polycarbonate.

ORDERING INFORMATION: Model # 84136500

Description Solid State Relay Cover

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/29

Page 34

SOLID STATE RELAY ACCESSORIES HS2 HEATSINK

2.000

4.770

DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

4.450

ORDERING INFORMATION: Model # HS2

Description Heatsink 2.0°C/W (For Single Phase SSR’s)

0.201

2.000 3.00

0.50

0.16

#8-32 UNC

FOR #8-32 SCREWS 4 PLACES

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/30

Page 35

SOLID STATE RELAY ACCESSORIES HS3 HEATSINK

1 2.625

4.750

0.50

0.201

3.00

4.430 0.16

2.000

DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

ORDERING INFORMATION: Model # HS3

Description Heatsink 1.5°C/W (For Single Phase SSR’s)

#8-32 UNC

FOR #8-32 SCREWS

HS13 HEATSINK

ORDERING INFORMATION: Model # HS13

Description Heatsink 0.8°C/W (For Single Phase and Three Phase SSR’s) DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/31

Page 36

SOLID STATE RELAY ACCESSORIES HS5 HEATSINK

2.630

4.750

DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

4.350

0.194

5.250 6.000

0.750

0.200

ORDERING INFORMATION: Model # HS5

Description Heatsink 0.7°C/W (For Single Phase SSR’s)

#8-32 UNC

HS6 HEATSINK

FOR #8-32 SCREWS 4 PLACES

6.250

6.250

Model # HS6

Description Heatsink 0.5°C/W (For Single Phase SSR’s)

1.00

0.201

ORDERING INFORMATION:

#8-32 UNC

6.00

6.050 0.10

4.000

DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

FOR #8-32 SCREWS 4 PLACES

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/32

Page 37

SOLID STATE RELAYS HS7 HEATSINK

1

3.70 [94.0]

2.84 [72.0]

.0125 [3.2]

ORDERING INFORMATION: Model # HS7

4.094 [104.0]

Description Heatsink 0.9°C/W (For GA3 Series SSR’s)

3.307 [84.0] 7.87[200.0]

6.89[175.0]

5.90[150.0]

5.59[142.0]

4.92[125.0]

3.94[100.0]

2.95[75.0]

1.97[50.0]

0.98[25.0]

0.0[0.0]

3.465[88.0]

1.88[47.7] M4 X 0.7(16)PLACES

MOUNTING HOLE (4)

DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/33

Page 38

SOLID STATE RELAYS HS8 HEATSINK

ORDERING INFORMATION: Model # HS8

Description Heatsink 2.1°C/W (For Single Phase SSR’s)

HS9 HEATSINK

ORDERING INFORMATION: Model # HS9

Description Heatsink 1.5°C/W (For Single Phase SSR’s)

DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/34

Page 39

SOLID STATE RELAYS HS10 HEATSINK

1

2.362

ORDERING INFORMATION: Model # HS10

Description Heatsink 1.1°C/W (For Single Phase SSR’s)

HS12 HEATSINK

ORDERING INFORMATION: Model # HS12

Description Heatsink 0.55°C/W (For Single Phase SSR’s)

DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/35

Page 40

SOLID STATE RELAYS STANDARDS MET BY SOLID-STATE RELAYS SERIES

NOTES CODE

GMS Series, 17.5mm DR GRD Series, 22.5mm DR GRD Series, 45mm DR GRD Series, 90mm DR GN Series “New Look” GD Series, Dual output 40A GD Series, Dual output 25A GNA5 Series SSR GA3 Series, 3-Phase GA0-12D25, 3-Phase Rev. GA0-12D40, 3-Phase Rev. GA8, GA1 Series GT60D10 I/O Modules (All) SMART SSR SMART Module

1,2,3,4 1,2,3,9 1,2,3,5,9 1,2,3,9 1,2,3,9 1,2,3,4,7 Pending 1,2,3 1,2,3,5,8 1,2,3,4,5,8 1,2,3,4,5 1,2,3,4 1,2,3,4,6,8 1,2,3,4,8 1,2,3,4,8 Pending 5 9 Pending 1,2,3 1,2,3

Notes: (1) UL Recognized – UL 508 (2) cUL Recognized – CSA C22.2 No. 14 (3) “CE” Mark based on LVD 73/23/EEC of 19/02/73 modified by Directive 93/68/EEC of 22/07/93 Supported by Conformity to EN60950 (4) IEC 664-1 (5) TUV Certificate (EN60950) (6) DEMKO Certificate (EN60950) (7) VDE Certificate (Pending) EN60950 (8) CSA C22.2 No. 14 (9) Manufacturer’s Declaration of Conformity EMC Compatibility to EN 50082-2 (Immunity) (Criteria from IEC 947-4-2) IEC 1000-4-2 Level 3 IEC 1000-4-3 Level 3 IEC 1000-4-4 Level 3 IEC 1000-4-5 Level 3 IEC 1000-4-6 Level 3 IEC 1000-4-11 (Pending) EMC Compatibility to EN 50081-2 (Emissions) C.I.S.P.R. 22 (Radiated) Class B C.I.S.P.R. 22 (Conducted) Class A (Requires EMI filter) EN60950 IEC 947-4-2 Class 2 equipment Utilization Category AC-53a Pluggable equipment – Type A Form 3 Motor Controller Pollution degree 1 IP20 Rating

Products and specifications subject to change without notice.

Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/36