Page 31
2-14
How PanelMate Series 500 Units Work Online With PLCs
Page 32
Chapter 3 From Opening the Boxes to Running Online: A Master Startup Flowchart In this chapter, you will learn: •
The overall sequence of steps necessary to configure, load and run a PanelMate Series 500 unit
•
The chapters in this manual providing specific startup guidance
•
A development checklist which can be used as a reminder during the startup process.
A Master Startup Flowchart
3-1
Page 33
The Master Startup Flowchart Start by Assembling: PanelMate Configuration software VGA Personal Computer Ladder Diagram(s) for partner PLCs
ê See Chapter 4
Load the Software To Your Personal Computer
See Chapter 5
Start a New Configuration (set of pages)
See Chapter 6
Assign PLC Communications
ê ê ê See Chapter 7
Create New Pages
See Chapter 8
Use the Virtual Mentor Capability (if applicable)
See Chapter 9
Save the Configuration
ê ê ê See Chapter 10
Compile the Configuration
See Chapter 11
Transfer the Configuration to an Online Unit
See Chapter 12
Run the PanelMate 500 Unit Online With the PLC
ê ê
3-2
A Master Startup Flowchart
Page 34
Development Checklist 1. Draw a flow chart of the application. 2. Determine the interaction between the pages and the function key/ LED pairs. 3. Begin to define page operation. Begin to assign page names and numbers and linkages. Use the Previous and Next navigation keys to maximum advantage. Review security password usage on a per page basis. 4. Remember to include a Startup Page(after power cycle) and a Home Page (for the Home navigation key). They may be the same page. 5. Review the need for a Setup Page(s) (provides contrast adjust, system info[filename] access and selection of Offline Mode. Consider password protection. 6. Review the need for Change Password Page(s). 7. Review the need for the Maintenance Page. 8. Once the flow chart is completed on paper use the editor to configure the pages and the function keys/LEDs. Review the PLC nomenclature that must be used to enter conditions, expressions, and responses. As you configure use the verify buttons to perform intermediate checks. 9. You may wish to complete sub sections of the application and verify online operation before completing the entire configuration. This will permit you to see the operation from the viewpoint of the operator and may change your implementation scheme. 10. Complete PLC Name and Port Table Parameters to enable communication with the PLC. 11. Save your configuration file, Verify it, Compile it, and Transfer it to the PanelMate 500. The first time you transfer to a new PanelMate 500 you must first download the appropriate PLC driver to the unit, then you can transfer the Configuration File. 12. Run the PanelMate 500 and verify operation. Continue to build the application in a piece-meal fashion until complete.
A Master Startup Flowchart
3-3
Page 35
3-4
A Master Startup Flowchart
Page 36
Chapter 4 Installing the Configuration Software In this chapter, you will learn: •
System requirements
•
Using the Setup Program to install the software
Installing the Configuration Software
4-1
Page 37
System Requirements The following table shows the software and hardware requirements for installing and running the PanelMate 500 Configuration Software. Operating System
MS-DOS version 5.0 or later plus any of the following: Microsoft Windows version 3.1 or later Windows for Workgroups version 3.1 or later Windows 95
Microprocessor
386 required (486/66MHz or higher recommended)
Memory
4 MB required 8 MB recommended when running multiple programs
Hard disk space
9 MB Typical
Disk drive
One 3.5-inch high-density drive
Video adapter
VGA or higher resolution; recommended environment is 640X480 with minimum 16 colors
Display device
Color or gray scale monitor or other display device (LCD, gas plasma, etc.)
Pointing device
Microsoft Mouse or compatible pointing device
If you are using a network to install or run the PanelMate 500 Configuration Software you must have a network compatible with your Windows operating environment, such as Microsoft Networks (Windows NT, Windows for Workgroups, or LAN Manager), Novelle NetWare®, Arttisoft® LANtastics, or Banyan® VINES®.
4-2
Installing the Configuration Software
Page 38
Running the Setup Program to Install the Software The following procedure describes how to install the PanelMate 500 Configuration Software to your computer’s hard disk from floppy disks. To install PanelMate 500 Configuration Software on your computer: 1. If you are using a virus-detection utility, disable it before running Setup. If you do not disable the utility, Setup may conflict with it and not run. 2. Start Windows and make sure that you close all open applications. 3. Insert the diskette labeled “Configuration Software” in drive A: or drive B:. 4. In the Windows Program Manager, choose Run from the File menu. 5. In the Command Line box, type the letter of the drive that contains the diskette with the Setup program on it, followed by a colon and the word setup. For example, type a:setup 6. Choose the OK button, and then follow the instructions on the screen. At the conclusion of the loading process, you will be prompted with the opportunity to view a “README.TXT” file. We recommend that you DO take a moment to read this file, which contains special notes or news about the software.
Installing the Configuration Software
4-3
Page 39
4-4
Installing the Configuration Software
Page 40
Chapter 5 Creating a New Configuration In this chapter, you will learn: •
About the PanelMate 500 Configuration Editor Main Screen
•
How to start a new Configuration
Creating a New Configuration
5-1