Molded Case Circuit Breakers 15-100 Amperes, Series CT G-Frame, pages 1 to 6
Pages 1 to 6 of 6
The original document is the PDF (143 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cutler-Hammer GHC3015 and Eaton GHC3015
Page 1
Cutler-Hammer
Molded Case Circuit Breakers 15-100 Amperes
March 1999
25
Series CT G-Frame ■
■
■
■
All two- and three-pole circuit breakers are of the common trip type. On all 3-phase Delta (240V) Grounded B phase applications, refer to Cutler-Hammer.
Interrupting Capacity Ratings
Single-pole circuit breakers, 15 and 20 amperes. Switching duty rated (SWD) for fluorescent lighting applications.
120
UL489 Interrupting Capacity Ratings Circuit Breaker Type
All G-frame circuit breakers are suitable for reverse feed use.
Number of Poles
GD
3
Circuit Breaker Type
Number of Poles
Interrupting Capacity (Symmetrical Amperes) (kA) Volts Ac (50/60 Hz) 240
–
277
65
480
–
125
22
250➀➁
–
10
Interrupting Capacity (Symmetrical Amperes) (kA) Volts Ac (50/60 Hz) 120
HACR rated.
Page Number
Volts Dc
Page Number
Volts Dc
240
277
480Y/277
125
26
125/250
GB
1 2, 3
65 –
– 65
– –
– –
14➂ –
– 14
27 27
GHB
1 2, 3
65 –
– 65
14 –
– 14
14➂ –
– 14
27 27
GC
1 2, 3
65 –
– 65
– –
– –
14➂ –
– 14
28 28
GHC
1 2, 3
65 –
– 65
14 –
– 14
14➂ –
– 14
28 28
Catalog Numbering System
Terminal Types
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
For line and load-side. Terminals are UL listed as suitable for wire type and size given below.
Circuit Breaker/Frame Catalog Number GD 3 100 Circuit Breaker Type
Number of Poles
Trip Amperes
Suffix
GD GB GHB GC GHC
1: 1 Pole 2: 2 Pole 3: 3 Pole
15 20 24 30 35 40 45 50 60 70 80 90 100
K: Molded Case Switch D: Ring Type Terminals C: Steel Collars V: 50°C J01: Fungus Proofed R01: Shock Tested F01: Freeze Tested
➀ Two poles of 3-pole circuit breaker. ➁ Time constant is 8 milliseconds minimum. ➂ 15 through 70A breakers only. ➃ Not UL listed sizes.
PG.74A.01.T.E
Circuit Breaker Amperes
Terminal Type Material
Screw Head Type
Wire Type
AWG Wire Range
Metric Wire➃ Range (mm2)
Standard 15-20 25-100
Clamp (Plated Steel) Slotted Cu/Al #14-10 Pressure (Aluminum Body) Slotted Cu/Al #10-1/0
2.5-4 4-50
Optional 15-50
Pressure (Steel Body)
Slotted Cu
–
–
Page 2
Time/Current Curves, Dimension Sheets, Application Data
26
Cutler-Hammer
Molded Case Circuit Breakers 15-100 Amperes
March 1999
Series CT G-Frame
Type GD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip-Units Maximum Continuous Ampere Rating @ 40°C
480 Vac Maximum, 250 Vdc➀
Catalog Number (Includes binding head screws)
22 kAIC @ 480 Vac Catalog Number (Includes Line and Load Terminals)
3-Pole 15 20 25 30 35 40 45 50 60 70 80 90 100
Typical Series C G-Frame Circuit Breaker
GD3015 GD3020 GD3025 GD3030 GD3035 GD3040 GD3045 GD3050 GD3060 GD3070 GD3080 GD3090 GD3100
GD3015D GD3020D GD3025D GD3030D GD3035D GD3040D GD3045D GD3050D GD3060D GD3070D GD3080D GD3090D GD3100D
Instruction Leaflet/FRED Number 29C102
Molded Case Switches Maximum Continuous Ampere Rating @ 40°C
480 Vac Maximum, 250 Vdc Catalog Number (Includes Line and Load Terminals)
3-Pole 60 100
GD3060K GD3100K
Instruction Leaflet/FRED Number 29C102
PG.74A.01.T.E
Page 3
Time/Current Curves, Dimension Sheets, Application Data
Cutler-Hammer March 1999
Molded Case Circuit Breakers 15-100 Amperes
27
Series CT G-Frame
Types GB and GHB Bolt-On Panelboard Circuit Breakers Type GB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
120 Vac Maximum, 125 Vdc Maximum➀
240 Vac Maximum, 125/250 Vdc Maximum
240 Vac Maximum, 125/250 Vdc Maximum➁
1-Pole
2-Pole
3-Pole
Catalog Number
15 20 25 30 35 40 45 50 60 70 80 90 100
Typical GB
These breakers meet the requirements of Federal Specification W-C-375b as follows: Types GB, GHB, 120 and 240 Volts: 1 Pole: Class 11a. 2, 3 Poles: Classes 10b, 11b, 12b, 14b, 15b
GB1015➂ GB1020➂ GB1025 GB1030 GB1035 GB1040 GB1045 GB1050 GB1060 GB1070 GB1080 GB1090 GB1100
GB2015➂ GB2020➂ GB2025 GB2030 GB2035 GB2040 GB2045 GB2050 GB2060 GB2070 GB2080 GB2090 GB2100
GB3015➂ GB3020➂ GB3025 GB3030 GB3035 GB3040 GB3045 GB3050 GB3060 GB3070 GB3080 GB3090 GB3100
Type GHB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units➃ Continuous Ampere Rating @ 40°C
Type GHB, 277 and 480Y/277 Volts: 1 Pole: Classes 12c, 13a 2, 3 Poles: Class 13b
277/480 Vac Maximum, 125 Vdc Maximum➀
277/480 Vac Maximum, 125/250 Vdc Maximum
277/480 Vac Maximum, 125/250 Vdc Maximum➁
1-Pole
2-Pole
3-Pole
Catalog Number
15 20 25 30 35 40 45 50 60 70 80 90 100
GHB1015➂ GHB1020➂ GHB1025 GHB1030 GHB1035 GHB1040 GHB1045 GHB1050 GHB1060 GHB1070 GHB1080 GHB1090 GHB1100
GHB2015➂ GHB2020➂ GHB2025 GHB2030 GHB2035 GHB2040 GHB2045 GHB2050 GHB2060 GHB2070 GHB2080 GHB2090 GHB2100
GHB3015➂ GHB3020➂ GHB3025 GHB3030 GHB3035 GHB3040 GHB3045 GHB3050 GHB3060 GHB3070 GHB3080 GHB3090 GHB3100
Instruction Leaflet/FRED Number 15547
Type GHBGFEP Bolt-on Panelboard 30mA Industrial Ground Fault Circuit Protectors 15-60 Amperes, 277 Volt, 50/60 Hz These circuit breakers meet the requirements of UL489 and UL1053. Operational voltage 240V to 305V. Interrupting Capacity Ratings Circuit Breaker Type
GHBGFEP
Number of Poles
2
Interrupting Capacity (Symmetrical Amperes) 277 Volts Ac (50/60 Hz)
14,000
Type GHBGFEP Bolt-on Panelboard 30mA Industrial Ground Fault Circuit Protectors with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
15 20 30 40 50 60
One Phase (Requires 2 Poles) 277V, 30mA Catalog Number
GHBGFEP1015 GHBGFEP1020 GHBGFEP1030 GHBGFEP1040 GHBGFEP1050 GHBGFEP1060
Instruction Leaflet/FRED Number 29C193
Single Phase (Requires 2 Poles)
PG.74A.01.T.E
➀ 15 through 70 ampere circuit breakers only. ➁ Use (2) outside poles. ➂ Uses .190-32 screw type clamp terminals. ➃ 480Y/277V, circuit breakers (Type GHB) not suitable for 3-phase Delta (480V).
Page 4
Time/Current Curves, Dimension Sheets, Application Data
28
Cutler-Hammer
Molded Case Circuit Breakers 15-100 Amperes
March 1999
Series CT G-Frame
Types GC and GHC Circuit Breakers
Type GC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
15-100 Amperes, 120, 240, 277, 480Y/277V, 50/60 Hz, 125, 125/250 Vdc, 1, 2, and 3 Poles
Continuous Ampere Rating @ 40°C
240 Vac Maximum, 125 Vdc Maximum➀
240 Vac Maximum, 125/250 Vdc Maximum
240 Vac Maximum, 125/250 Vdc Maximum➁
1-Pole
2-Pole
3-Pole
Catalog Number
15 20 25 30 35 40 45 50 60 70 80 90 100 Typical GC
These breakers meet the requirements of Federal Specification W-C-37b as follows:
GC1015➂ GC1020➂ GC1025 GC1030 GC1035 GC1040 GC1045 GC1050 GC1060 GC1070 GC1080 GC1090 GC1100
GC2015➂ GC2020➂ GC2025 GC2030 GC2035 GC2040 GC2045 GC2050 GC2060 GC2070 GC2080 GC2090 GC2100
GC3015➂ GC3020➂ GC3025 GC3030 GC3035 GC3040 GC3045 GC3050 GC3060 GC3070 GC3080 GC3090 GC3100
Type GHC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
277 Vac Maximum, 125 Vdc Maximum➀
480Y/277 Vac Maximum, 125/250 Vdc Maximum
480Y/277 Vac Maximum, 125/250 Vdc Maximum➁
1-Pole
2-Pole
3-Pole
Catalog Number
Types GC, 120 and 240 Volts: 1 Pole: Class 11a 2, 3 Poles: Classes 10b, 11b, 12b, 14b, 15b
15 20 25 30 35 40 45 50 60 70 80 90 100
Type GHC, 277 and 480Y/277 Volts: 1 Pole: Classes 12c, 13a 2, 3 Poles: Class 13b
GHC1015➂ GHC1020➂ GHC1025 GHC1030 GHC1035 GHC1040 GHC1045 GHC1050 GHC1060 GHC1070 GHC1080 GHC1090 GHC1100
GHC2015➂ GHC2020➂ GHC2025 GHC2030 GHC2035 GHC2040 GHC2045 GHC2050 GHC2060 GHC2070 GHC2080 GHC2090 GHC2100
GHC3015➂ GHC3020➂ GHC3025 GHC3030 GHC3035 GHC3040 GHC3045 GHC3050 GHC3060 GHC3070 GHC3080 GHC3090 GHC3100
Instruction Leaflet/FRED Number 15548
Type GHCGFEP Cable In/Cable Out 30mA Industrial Ground Fault Circuit Protectors 15-60 Amperes, 277 Volt, 50/60 Hz These circuit breakers meet the requirements of UL489 and UL1053. Operational voltage 240V to 305V. Interrupting Capacity Ratings Circuit Breaker Type
GHCGFEP
Number of Poles
2
Interrupting Capacity (Symmetrical Amperes) 277 Volts Ac (50/60 Hz)
14,000
Type GHBGFEP Bolt-on Panelboard 30mA Industrial Ground Fault Circuit Protectors with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
15 20 30 40 50 60
One Phase (Requires 2 Poles) 277V, 30mA Catalog Number
GHBGFEP1015 GHBGFEP1020 GHBGFEP1030 GHBGFEP1040 GHBGFEP1050 GHBGFEP1060
Instruction Leaflet/FRED Number 29C193
Single Phase Requires 2 Poles)
➀ 15 through 70 ampere circuit breakers only. ➁ Use (2) outside poles. ➂ Uses .190-32 screw type clamp terminals.
PG.74A.01.T.E
Page 5
Time/Current Curves, Dimension Sheets, Application Data
Cutler-Hammer
Molded Case Circuit Breakers 15-100 Amperes
March 1999
Series CT G-Frame
Special Purpose Breakers marked “Special purpose breaker not for general use.” To order this special breaker, use the catalog number below.
These are Types GC and GHC circuit breakers with binding head screwtype terminals on line and load side. These circuit breakers with screwtype terminals (.190-32) will be
Type GC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
120 Vac Maximum, 125 Vdc Maximum
240 Vac Maximum, 125/250 Vdc Maximum
240 Vac Maximum, 125/250 Vdc Maximum➀
1-Pole
2-Pole
3-Pole
Catalog Number
25 30 35 40 45 50 55 60
GC1025D GC1030D GC1035D GC1040D GC1045D GC1050D GC1055D GC1060D
GC2025D GC2030D GC2035D GC2040D GC2045D GC2050D GC2055D GC2060D
GC3025D GC3030D GC3035D GC3040D GC3045D GC3050D GC3055D GC3060D
Type GHC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Continuous Ampere Rating @ 40°C
277 Vac Maximum, 125 Vdc Maximum
480Y/277 Vac Maximum, 125/250 Vdc Maximum
480Y/277 Vac Maximum, 125/250 Vdc Maximum➀
1-Pole
2-Pole
3-Pole
Catalog Number
25 30 35 40 45 50 55 60
GHC1025D GHC1030D GHC1035D GHC1040D GHC1045D GHC1050D GHC1055D GHC1060D
Instruction Leaflet/FRED Number 15548
➀ Use (2) outside poles.
PG.74A.01.T.E
GHC2025D GHC2030D GHC2035D GHC2040D GHC2045D GHC2050D GHC2055D GHC2060D
GHC3025D GHC3030D GHC3035D GHC3040D GHC3045D GHC3050D GHC3055D GHC3060D
29
Page 6
30
Cutler-Hammer
Molded Case Circuit Breakers 15-100 Amperes
March 1999
Series CT G-Frame
Dimensions/Weights Dimensions, Inches (mm) Number of Poles
Width
Height
Depth
1
1.0 (25.33)
4.88 (123.95)
2.81 (71.41)
2
2.0 (50.78)
4.88 (123.95)
2.81 (71.41)
3
3.0 (76)
4.88 (123.95)
2.81 (71.41)
Approximate Shipping Weight, Lbs. (kg) Breaker Type
Number of Poles 1
2
3
GD
1.0 (.454)
1.5 (.680)
2.25 (1.021)
GHBGFEP
–
1.2 (.545)
–
GHCGFEP
–
1.1 (.499)
–
GB/GHC
Carton Quantity
GC/GHC
24
12
8
16 (7.264)
16 (7.264)
16 (7.264)
Carton Quantity
24
12
8
18 (8.172)
18 (8.172)
18 (8.172)
Accessories Internal Alarm Switch . . . . . . . . . . . . . . . . 139 Auxiliary Switch. . . . . . . . . . . . . . 142 Shunt Trip . . . . . . . . . . . . . . . . . . 147 Undervoltage Release Mechanism . . . . . . . . . . . . . . . . 153
External Base Mounting Hardware . . . . . . 163 Base Mounting Plate . . . . . . . . . . 167 DIN Rail Adapter . . . . . . . . . . . . . 167 Key Operated Attachment. . . . . . 167 Lock Dog (non-padlockable) . . . . 168 Padlockable Handle . . . . . . . . . . . 168 Handle Mechanisms . . . . . . . . . . 180
PG.74A.01.T.E