This is a single distributor catalog page (page 713, Controls, Relays and Timers) listing Eaton Cutler-Hammer relays and timers with WESCO part numbers. It covers the D26 Series Type M pneumatic timer attachment and timer relay, D60 current-sensitive relays, D64 ground fault relays, D80 pneumatic timers and D40 Type R hermetically sealed relays. It does not name the D26MB relay base itself.

Document
Distributor catalog page listing Eaton Cutler-Hammer relays and timers p. 1
D26 timer attachment
D26MTD and D26MTE (off delay and on delay versions), 0.1 to 180 seconds, repeat accuracy about 10% p. 1
Timer fit
Mounts on any 0- to 4-pole D26 relay without latch; DPDT timed contacts; convertible OFF to ON delay p. 1
D26 timer relay
D26MR005A: D26 Type M relay with factory-installed ON delay timer; takes up to 4 D26MPR contacts p. 1
D60 relays
D60LA1: 0.5–4.5 A trip setting; D60LA3: 2.5–22.5 A; D60LA module and D60LA0 relay without transformer p. 1
D64 ground fault
D64RPB1 for a separate C311CT sensor, 120 VAC; D64RPB3 with built-in 1.8 in. sensor, 24–250 VAC/DC; 10mA–6.4A trip range p. 1
D80 timers
Pneumatic, 0.5 to 180 seconds, ON delay field-convertible to OFF delay; D80NE1A, D80NE1C, D80JE10A, D80NE2A p. 1
D40 relay parts
300V relay base D40RBA, coil pole D40RCA120, NO pole D40RPA (green), NC pole D40RPB (yellow) p. 1
D80 switch block
D80AS1, SPDT, for replacement or conversion of D80 timers p. 1

What this manual walks you through

  • Choosing a pneumatic timer attachment for a D26 Type M relay p. 1
  • Ordering a D40 Type R relay from base, coil pole and contact poles p. 1
  • Selecting D60 current-sensitive and D64 ground fault relays p. 1

Good to know

  • The D26 timer relay comes without contacts; they are bought separately. p. 1
  • On the D26 timer attachment, the circuits in each pole must be the same polarity. p. 1

Questions this manual answers

What timing range does the D26 pneumatic timer attachment have?

0.1 to 180 seconds, with repeat accuracy of about 10%. p. 1

Which D26 relays take the pneumatic timer attachment?

Any 0- to 4-pole D26 relay without a latch. p. 1

Does the D26MR005A timer relay include contacts?

No. It accepts up to 4 D26MPR contacts, which are bought separately. p. 1

What trip current range does the D64 ground fault relay cover?

10mA to 6.4A. p. 1

The file

Size and text

Pages1
PDF137 KB
TextText from the PDF itself.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Eaton Cutler-Hammer D26 Series Type M Machine Tool Relays Catalog Page

The text of page 1, from the PDF itself

Elec08_sec12_712&71311/30/084:32 PMPage 713

Relays

  • Pneumatic Timer Attachment for Eaton’s Cutler-Hammer D26 Series Type M 600 VAC Multi-Pole Machine Tool Relays Adjustable timing range from 0.1 to 180 seconds with repeat accuracy of approximately 10%

Mfr.’s Model No.Type of Contacts(1) NO (1) NC

  • Eaton’s Cutler-Hammer D60 Series Adjustable Current-Sensitive Special Purpose Relays

Mfr.’s Model No.

Operation

782113-27723 782113-21976

D26MTD D26MTE

Off Delay On Delay

  • Eaton’s Cutler-Hammer D26 Series Type M 600 VAC Multi-pole Machine Tool Relay with Pneumatic Timer Attachment
  • Accepts up to 4 D26MPR contacts (convertible, NO or NC) for instantaneous operation
  • Timer has DPDT timed contacts and adjustable timing range of 0.1 to 180 seconds
  • Note: Contacts not included, must be purchased separately Coil Volts

120 VAC

  • Eaton’s Cutler-Hammer D80 Series Pneumatic Timers

Ideal for conveyor, intermittent conveyor, belt and gear reduction, water-lubricated pump, and batch-process mixing applications

D60LA0

D60LA

  • Sense a pre-set current value and operate a 600 VAC SPDT relay whose contacts may be used in a control circuit
  • Provide a continuously adjustable trip-current setting and automatic reset for control of machines
  • Suitable for protection of mechanical apparatus from jam-up or other overloading conditions

WESCO Part No.

Mfr.’s Model No.

Trip Max. Setting Max. Cont. Inrush Amps Amps Amps

Module Only________________________________ 782113-29595 D60LA None None None Relay without Transformer ____________________ 782113-30079 D60LA0 None None None Relay with Transformer ______________________ 782113-30408 D60LA1 0.5–4.5 7 35 782113-31992 D60LA3 2.5–22.5 30 150

Timers are supplied as complete devices with switch block and solenoid assembled

  • Eaton’s Cutler-Hammer D64 Series Digital Electronic Ground Fault Special Purpose Relays
  • Adjustable timing range of 0.5 to 180 seconds with repeat accuracy of approx. 10% and min. reset time of 0.05 sec.
  • Surface mount with screw terminals
  • ON delay operation (field-convertible to OFF delay)
  • UL Listed and CSA Certified

Provides reliable protection on resistance grounded and solidly grounded power distribution systems

  • Includes built-in self-test and reset circuitry
  • Selectable failsafe/ nonfailsafe operation
  • Any ground fault deterioration on the system is detected immediately and a trip (or alarm) is activated
  • 10mA–6.4A trip current range

WESCO Part No.Mfr.’s Model No.Instant ContactsCoil Volts

Pneumatic Timers with (1) NO and (1) NC Timed Contact ________________________ 782113-20044 D80NE1A None 120 VAC 782113-20046 D80NE1C N/A 480 VAC (Will Not Accept) 782113-20038 D80JE10A None 120 VAC Pneumatic Timers with (2) NO and (2) NC Timed Contacts ______________________ 782113-20047 D80NE2A N/A 120 VAC (Will Not Accept)

WESCO Part No.Mfr.’s Model No.Control Power

Relay for Use with Separately Mounted C311CT Current Sensor ______________________ 782113-91850 D64RPB1 120 VAC Relay with Built-In 1.8" Current Sensor __________ 782113-91852 D64RPB3 24–250 VAC/DC

  • Suitable for use in Class 1 Division 2, Groups A, B, C, and other ordinary locations
  • Feature convertible contacts and screw terminals
  • Provide environmental immunity and low contact resistance
  • UL® Listed and CSA Certified WESCO Part No.

Mfr.’s Model No.

Contact Config.

2-Pole, 24/28 VDC Coil ____________________ 782113-18226 D40RR11T1 1-NO 1-NC 4-Pole, 120 VAC Coil ______________________ 782113-18264 D40RR22A 2-NO 2-NC 782113-18318 D40RR40A 4-NO 6-Pole, 120 VAC Coil ______________________ 782113-18306 D40RR33A 3-NO 3-NC 7-Pole - - 120 VAC Coil ______________________ 782113-18312 D40RR34A 3-NO 4-NC 782113-18336 D40RR43A 4-NO 3-NC 782113-18354 D40RR52A 5-NO 2-NC 782113-18366 D40RR61A 6-NO 1-NC

  • Component Parts for Eaton’s Cutler-Hammer D40 Series Type R Powered Multipole Hermetically-Sealed Relays All of the components you need to create a panel-mounted, electricallyheld, multi-pole 300V relay for use with industrial control circuits
  • Provide environmental immunity and low contact resistance
  • Purchase relay base and contact poles separately
  • UL Listed and CSA Certified

D40RBA WESCO Part No.D40RCA120D40RPAMfr.’s Model No.

300V Relay Base with Screw Terminals, 120 VAC Coil Pole Only & 4-Pole Spaces (No Contact Poles Included) __________________ 782113-18378 D40RBA 120 VAC Coil Pole (for replacement only) ________ 782113-18384 D40RCA120 300V Pole with (1) Fixed NO Contact, Green ____ 782113-21394 D40RPA 300V Pole with (1) Fixed NC Contact, Yellow ____ 782113-21395 D40RPB

713

Controls, Relays, & Timers

Relay with factory-installed ON delay timer

782113-27715 D26MR005A

Completely assembled panel-mounted, multipole 300V relays for use with industrial control circuits

782113-20027 D80AS1WESCO Part No.Mfr.’s Model No.

or conversion of D80 timers

  • Use for either timed or instantaneous contacts
  • SPDT circuit
  • UL Listed and CSA Certified WESCO Part No.
  • Mounts on any 0- to 4-pole D26 relay without latch
  • Features DPDT time contacts, circuits in each pole must be the same polarity
  • Convertible from OFF delay to ON delay or vice versa

WESCO Part No.

  • Switch Block for Eaton’s Cutler-Hammer ■ Eaton’s Cutler-Hammer D40 Series Type R Powered Multi-pole D80 Series Pneumatic Timers Hermetically-Sealed Relays Used for replacement