This is a single distributor catalog page (page 713, Controls, Relays and Timers) listing Eaton Cutler-Hammer relays and timers with WESCO part numbers. It covers the D26 Series Type M pneumatic timer attachment and timer relay, D60 current-sensitive relays, D64 ground fault relays, D80 pneumatic timers and D40 Type R hermetically sealed relays. It does not name the D26MB relay base itself.
- Document
- Distributor catalog page listing Eaton Cutler-Hammer relays and timers p. 1
- D26 timer attachment
- D26MTD and D26MTE (off delay and on delay versions), 0.1 to 180 seconds, repeat accuracy about 10% p. 1
- Timer fit
- Mounts on any 0- to 4-pole D26 relay without latch; DPDT timed contacts; convertible OFF to ON delay p. 1
- D26 timer relay
- D26MR005A: D26 Type M relay with factory-installed ON delay timer; takes up to 4 D26MPR contacts p. 1
- D60 relays
- D60LA1: 0.5–4.5 A trip setting; D60LA3: 2.5–22.5 A; D60LA module and D60LA0 relay without transformer p. 1
- D64 ground fault
- D64RPB1 for a separate C311CT sensor, 120 VAC; D64RPB3 with built-in 1.8 in. sensor, 24–250 VAC/DC; 10mA–6.4A trip range p. 1
- D80 timers
- Pneumatic, 0.5 to 180 seconds, ON delay field-convertible to OFF delay; D80NE1A, D80NE1C, D80JE10A, D80NE2A p. 1
- D40 relay parts
- 300V relay base D40RBA, coil pole D40RCA120, NO pole D40RPA (green), NC pole D40RPB (yellow) p. 1
- D80 switch block
- D80AS1, SPDT, for replacement or conversion of D80 timers p. 1
What this manual walks you through
- Choosing a pneumatic timer attachment for a D26 Type M relay p. 1
- Ordering a D40 Type R relay from base, coil pole and contact poles p. 1
- Selecting D60 current-sensitive and D64 ground fault relays p. 1
Good to know
- The D26 timer relay comes without contacts; they are bought separately. p. 1
- On the D26 timer attachment, the circuits in each pole must be the same polarity. p. 1
Questions this manual answers
What timing range does the D26 pneumatic timer attachment have?
0.1 to 180 seconds, with repeat accuracy of about 10%. p. 1
Which D26 relays take the pneumatic timer attachment?
Any 0- to 4-pole D26 relay without a latch. p. 1
Does the D26MR005A timer relay include contacts?
No. It accepts up to 4 D26MPR contacts, which are bought separately. p. 1
What trip current range does the D64 ground fault relay cover?
10mA to 6.4A. p. 1
The file
Size and text
Every page · 1
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 1
Open in the PDF
The text of page 1, from the PDF itself
Elec08_sec12_712&71311/30/084:32 PMPage 713
Relays
- Pneumatic Timer Attachment for Eaton’s Cutler-Hammer D26 Series Type M 600 VAC Multi-Pole Machine Tool Relays Adjustable timing range from 0.1 to 180 seconds with repeat accuracy of approximately 10%
Mfr.’s Model No.Type of Contacts(1) NO (1) NC
- Eaton’s Cutler-Hammer D60 Series Adjustable Current-Sensitive Special Purpose Relays
Mfr.’s Model No.
Operation
782113-27723 782113-21976
D26MTD D26MTE
Off Delay On Delay
- Eaton’s Cutler-Hammer D26 Series Type M 600 VAC Multi-pole Machine Tool Relay with Pneumatic Timer Attachment
- Accepts up to 4 D26MPR contacts (convertible, NO or NC) for instantaneous operation
- Timer has DPDT timed contacts and adjustable timing range of 0.1 to 180 seconds
- Note: Contacts not included, must be purchased separately Coil Volts
120 VAC
- Eaton’s Cutler-Hammer D80 Series Pneumatic Timers
Ideal for conveyor, intermittent conveyor, belt and gear reduction, water-lubricated pump, and batch-process mixing applications
D60LA0
D60LA
- Sense a pre-set current value and operate a 600 VAC SPDT relay whose contacts may be used in a control circuit
- Provide a continuously adjustable trip-current setting and automatic reset for control of machines
- Suitable for protection of mechanical apparatus from jam-up or other overloading conditions
WESCO Part No.
Mfr.’s Model No.
Trip Max. Setting Max. Cont. Inrush Amps Amps Amps
Module Only________________________________ 782113-29595 D60LA None None None Relay without Transformer ____________________ 782113-30079 D60LA0 None None None Relay with Transformer ______________________ 782113-30408 D60LA1 0.5–4.5 7 35 782113-31992 D60LA3 2.5–22.5 30 150
Timers are supplied as complete devices with switch block and solenoid assembled
- Eaton’s Cutler-Hammer D64 Series Digital Electronic Ground Fault Special Purpose Relays
- Adjustable timing range of 0.5 to 180 seconds with repeat accuracy of approx. 10% and min. reset time of 0.05 sec.
- Surface mount with screw terminals
- ON delay operation (field-convertible to OFF delay)
- UL Listed and CSA Certified
Provides reliable protection on resistance grounded and solidly grounded power distribution systems
- Includes built-in self-test and reset circuitry
- Selectable failsafe/ nonfailsafe operation
- Any ground fault deterioration on the system is detected immediately and a trip (or alarm) is activated
- 10mA–6.4A trip current range
WESCO Part No.Mfr.’s Model No.Instant ContactsCoil Volts
Pneumatic Timers with (1) NO and (1) NC Timed Contact ________________________ 782113-20044 D80NE1A None 120 VAC 782113-20046 D80NE1C N/A 480 VAC (Will Not Accept) 782113-20038 D80JE10A None 120 VAC Pneumatic Timers with (2) NO and (2) NC Timed Contacts ______________________ 782113-20047 D80NE2A N/A 120 VAC (Will Not Accept)
WESCO Part No.Mfr.’s Model No.Control Power
Relay for Use with Separately Mounted C311CT Current Sensor ______________________ 782113-91850 D64RPB1 120 VAC Relay with Built-In 1.8" Current Sensor __________ 782113-91852 D64RPB3 24–250 VAC/DC
- Suitable for use in Class 1 Division 2, Groups A, B, C, and other ordinary locations
- Feature convertible contacts and screw terminals
- Provide environmental immunity and low contact resistance
- UL® Listed and CSA Certified WESCO Part No.
Mfr.’s Model No.
Contact Config.
2-Pole, 24/28 VDC Coil ____________________ 782113-18226 D40RR11T1 1-NO 1-NC 4-Pole, 120 VAC Coil ______________________ 782113-18264 D40RR22A 2-NO 2-NC 782113-18318 D40RR40A 4-NO 6-Pole, 120 VAC Coil ______________________ 782113-18306 D40RR33A 3-NO 3-NC 7-Pole - - 120 VAC Coil ______________________ 782113-18312 D40RR34A 3-NO 4-NC 782113-18336 D40RR43A 4-NO 3-NC 782113-18354 D40RR52A 5-NO 2-NC 782113-18366 D40RR61A 6-NO 1-NC
- Component Parts for Eaton’s Cutler-Hammer D40 Series Type R Powered Multipole Hermetically-Sealed Relays All of the components you need to create a panel-mounted, electricallyheld, multi-pole 300V relay for use with industrial control circuits
- Provide environmental immunity and low contact resistance
- Purchase relay base and contact poles separately
- UL Listed and CSA Certified
D40RBA WESCO Part No.D40RCA120D40RPAMfr.’s Model No.
300V Relay Base with Screw Terminals, 120 VAC Coil Pole Only & 4-Pole Spaces (No Contact Poles Included) __________________ 782113-18378 D40RBA 120 VAC Coil Pole (for replacement only) ________ 782113-18384 D40RCA120 300V Pole with (1) Fixed NO Contact, Green ____ 782113-21394 D40RPA 300V Pole with (1) Fixed NC Contact, Yellow ____ 782113-21395 D40RPB
713
Controls, Relays, & Timers
Relay with factory-installed ON delay timer
782113-27715 D26MR005A
Completely assembled panel-mounted, multipole 300V relays for use with industrial control circuits
782113-20027 D80AS1WESCO Part No.Mfr.’s Model No.
or conversion of D80 timers
- Use for either timed or instantaneous contacts
- SPDT circuit
- UL Listed and CSA Certified WESCO Part No.
- Mounts on any 0- to 4-pole D26 relay without latch
- Features DPDT time contacts, circuits in each pole must be the same polarity
- Convertible from OFF delay to ON delay or vice versa
WESCO Part No.
- Switch Block for Eaton’s Cutler-Hammer ■ Eaton’s Cutler-Hammer D40 Series Type R Powered Multi-pole D80 Series Pneumatic Timers Hermetically-Sealed Relays Used for replacement