Eaton catalog section on control relays and timers, including the D26 Type M machine tool relay and its D26MB relay base assembly.
What this file really is
The old site listed this file as “Tech Manual” for the Cutler-Hammer D26MB and Eaton D26MB. Linked as a D26MB tech manual, it is the Control Relays & Timers catalog section covering many Eaton relay families, of which the D26 Type M relay and its D26MB base are one entry.
Filed under · 2 models
Filed under these models in the old catalog
Summary
What is in it
The Control Relays & Timers section (Tab 49) of an Eaton catalog. It opens with selection guides by catalog prefix and relay type, then gives features, product selection, specifications and dimensions for XR terminal block relays, EZ intelligent relays, general purpose plug-in relays, machine tool relays (D15, BF/BFD, AR/ARD and the D26 Type M with its D26MB base), timing relays, phase, current and voltage monitoring relays, alternating relays and ground fault relays.
Its parts
- Relay Product Family Overview
- XR Series Terminal Block Relays
- EZ Intelligent Relays
- General Purpose Plug-In Relays
- General Purpose Relays, Type AA
- Machine Tool Relays
- Timing Relays
- Phase Monitoring Relays
- Current Monitoring Relays
- Voltage Monitoring Relays
- Alternating Relays
- Ground Fault Relays and Monitors
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is an Eaton catalog section, Control Relays and Timers (July 2008, CA08102001E), covering many relay families from terminal block relays to timing and monitoring relays. Its D26 Series Type M machine tool relay pages list the D26MB relay base assembly together with the contact poles, front decks, timer attachments and accessories that build it into a complete relay. This summary reads the contents and the D26 Type M pages.
- Device
- Relay base assembly without poles: the basic 4-pole D26 Type M relay without contacts p. 89
- Rear poles
- Accepts 1 to 4 rear poles, types D26MPR, D26MPS and/or D26MPL p. 87
- Coil
- Order with a magnet coil suffix letter, for example D26MBA p. 89
- Relay family
- D26 Type M machine tool relay, panel or channel mount, convertible contacts, 10A AC maximum p. 2
- Contact rating
- A600, 600V AC multipole p. 87
- Convertible poles
- D26MPR and D26MPF poles convert NO to NC by reversing the terminal screws and turning the pole 180° p. 87
- Maximum poles
- Up to 12NO, or 8NC and 4 NO; a D26MF attachment adds 4 fixed NO poles p. 87
- Front deck
- D26MD10, D26MD20, D26MD40 add up to 4 convertible front poles (D26MPF) p. 89
- Timer attachment
- Pneumatic, D26MTE or D26MTD (ON or OFF delay), 0.1 to 180 seconds, repeat accuracy ±10% p. 89
- Separate contacts
- Rear D26MPR, D26MPR02; front D26MPF, D26MPF02; gold plated D26MPR03, D26MPF03; D26MPS, D26MPL p. 88
- Accessories
- Indicating light D26MAP120 or D26MAP240; transient suppressors D26MAS1, D26MAS2; manual test tool D26MTA p. 89
- Mounting channel
- D26MC4, D26MC8, D26MC12, D26MC16, for 4 to 16 relays, 10 to 40 in. long p. 89
- Listings
- The catalog states UL Listed (Class No. NKCR2) and CSA Certified (File LR353) p. 87
What this manual walks you through
- Ordering complete AC relays by NO and NC contact count p. 88
- Building a relay from the base assembly and separate poles p. 88, 89
- Converting contact poles between NO and NC p. 87
- Adding a front deck, four-pole front attachment, timer or mechanical latch p. 87, 89
- DC Type M relays: ratings, latch operation and ordering p. 90, 91
- Relay and mounting channel dimensions p. 92
Good to know
- Overlapping contacts need the D26MPS early closing and D26MPL late opening rear poles in related circuits. p. 87
- The timer attachment fits a 0- to 4-pole D26 relay without latch, and the circuits in each pole must have the same polarity. p. 89
- Relays with a mechanical latch go up to eight poles. p. 87
- DC Type M relays use the same component parts as the AC ones, except the indicating light. p. 90
Questions this manual answers
What is the Eaton D26MB?
It is the D26 Type M relay base assembly: a basic 4-pole relay without contacts that takes 1 to 4 rear poles (D26MPR, D26MPS or D26MPL). p. 87, 89
How do I order a D26MB with a coil voltage?
Add the magnet coil suffix letter to the catalog number, for example D26MBA. p. 89
How do I change a D26 contact from NO to NC?
On D26MPR and D26MPF poles, reverse the terminal screws and rotate the pole 180°. p. 87
What timer fits the D26 Type M relay?
The pneumatic timer attachment D26MTE or D26MTD, ON or OFF delay, adjustable from 0.1 to 180 seconds, on a 0- to 4-pole relay without latch. p. 89
How many poles can a D26 relay have?
Up to 12: 8 convertible poles plus a D26MF attachment with 4 fixed NO poles. p. 87
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 142141-142
The file