Page 31

Control Relays & Timers EZ Intelligent Relays

49-31

July 2008

EZ/EZD Accessories

Grounding the Screen for Top-Hat Rail

Grounding the Screen for Mounting Plate

Figure 49-37. EZB4-102-KS1 Series

Connect Outputs Digital Inputs

DEL

ALT

ESC

OK

Connection Cable

49

Power Supply Unit

Figure 49-38. EZ412-DC-SIM-NA Series

CA08102001E

For more information visit: www.eaton.com

Page 32

49-32

Control Relays & Timers EZ Intelligent Relays July 2008

EZ/EZD Accessories

0.30 (7.5)

1.77 (45)

3.54 4.02 4.33 (90) (102) (110)

1.77 (45) 1.87 (47.5)

M4 1.40 (35.5)

2.22 (56.5)

Figure 49-39. EZ256-HCI Dimensions in Inches (mm)

Wiring Diagram L N >1A S.. S..

49

L

N

N

115/230 Vh

I1

I2

I3

I4

I5

.....

N

N

1

2

3

4

5

6

Input 115/230 Vh

EZ5..-AC-.. EZ7..-AC-..

EZ256-HCI

Figure 49-40. EZ256-HCI Wiring Diagram

For more information visit: www.eaton.com

CA08102001E

Page 33

Control Relays & Timers General Purpose Plug-In Relays

49-33

July 2008

Selection Guide

Contents

Selection Guide

Description

Page

General Purpose Plug-In Relays Selection Guide . . . . . . . . . D2 Series . . . . . . . . . . . . . . D3 Series . . . . . . . . . . . . . . D4 Series . . . . . . . . . . . . . . D5 Series . . . . . . . . . . . . . . D7 Series . . . . . . . . . . . . . . D8 Series . . . . . . . . . . . . . . D9 Series . . . . . . . . . . . . . .

General Purpose Relay Selection Characteristics ■ Current Rating: 1A – 30A

49-33 49-35 49-43 49-49 49-52 49-56 49-67 49-71

■ Contact Arrangement: SPDT, DPDT,

3PDT, 4PDT, etc. ■ Coil Voltage: 6V – 240V AC/

6V – 110V DC ■ Mounting Options: Socket, Flange,

DIN Rail, Panel ■ Specifications: CSA, CE, IEC, NEMA,

UL, etc.

General Purpose Plug-In Relay

■ Other: Physical Dimensions, Maxi- mum Voltage, Mechanical/Electrical Life, etc. Table 49-41. General Purpose Plug-In Relays Selection Guide Relay Series

D2PF/D2PR

D3PF/D3PR

D4PR

Polycarbonate Cover

Polycarbonate Cover

Polycarbonate Cover

Indicator Lamp and Pushbutton Available

Indicator Lamp and Pushbutton Available

Indicator Lamp Available

Panel, DIN and Flange Mounting

Panel and DIN Mounting

Panel and DIN Mounting

8 or 11 Pin Octal Plug-In

Socket Has Built-In Hold Down Spring

Approvals

Features

Latching

Latching (D3PR version)

Contact Data Configuration

DPDT

Max. Allowable Load

D2PF: 10A at 3A at 120V AC 220V AC D2PR: 5A at 240V AC

DPDT Latching

4PDT

SPDT

DPDT

3A at 240V AC

12A at 120V AC

12A at 10A at 120V AC 240V AC

3PDT

SPDT

DPDT

10A at 250V AC

5A at 240V AC

Material

Ag (Au Flashed)

AgCdO (Au Flashed)

AgCdO

Resistance

50 Milliohms (Initial)

50 Milliohms (Initial)

100 Milliohms (Initial)

1500V

1500V

5000V

AC

6 – 240V AC

24 – 240V AC (D3PF) / 6 – 240V AC (D3PR)

6 – 240V AC

DC

6 – 110V DC

12 – 110V DC (D3PF) / 6 – 110V DC (D3PR)

6 – 110V DC

Power VA (V AC) Watts (V DC)

1.2 VA 1.1 Watts

2.75 VA 1.2 Watts

0.9 VA 0.5 Watts

-40 – 158°F (-40° – 70°C) -40 – 221°F (-40° – 105°C)

-49 – 131°F (-45° – 55°C) -40 – 221°F (-40° – 105°C)

-40 – 158°F (-40° – 70°C) -40 – 158°F (-40° – 70°C)

Maximum Pick-Up

20 / 25 Milliseconds

15 Milliseconds

15 Milliseconds

Maximum Release

20 / 25 Milliseconds

10 Milliseconds

10 (AC)/5 (DC) Milliseconds

10 Million 200,000

5 Million (D3PF) / 10 Million (D3PR) 200,000 (D3PF) / 100,000 (D3PR)

10 Million 100,000

Pages 49-35 – 49-42

Pages 49-43 – 49-48

Pages 49-49 – 49-51

Dielectric Strength

Coil Data

General Data Ambient Temperature Operational Storage

Life Mechanical Operations Electrical Operations Page Number

CA08102001E

For more information visit: www.eaton.com

49

Page 34

Control Relays & Timers General Purpose Plug-In Relays

49-34

July 2008

Selection Guide Table 49-41. General Purpose Plug-In Relays Selection Guide (Continued) Relay Series

D5PF/D5PR

D7PF/D7PR

D8PR

D9PR

Approvals

Features

Polycarbonate Cover

Polycarbonate Cover

Dust Cover

Dust Cover

Indicator Lamp and Pushbutton Available

Indicator Lamp and Pushbutton Available

Panel, DIN and Flange Mounting

Pushbutton Available

Panel, DIN and PC Board Mounting

Panel, DIN and Flange Mounting

Quick-Connect and Screw Terminals

Panel Mounting

SPDT

SPDT

Screw Terminals

Contact Data Configuration Max. Allowable Load

DPDT

15A at 240V AC

15A at 240V AC

3PDT 15A at 240V AC

DPDT

20A at 277V AC

3PDT

15A at 120V AC

15A at 120V AC

4PDT 15A at 120V AC

SPST-NO 30A at 220V AC

DPST-NO 25A at 220V AC

4PST NO

NC

25A at 220V AC

8A at 220V AC

Material

AgCdO (Au Flashed)

AgCdO

AgCdO

AgCdO

Resistance

50 Milliohms (Initial)

50 Milliohms (Initial)

50 Milliohms (Initial)

50 Milliohms (Initial)

1500V (D5PF) / 2000V (D5PR)

1000V(D7PF1, D7PF2, D7PF3) / 1500V

4000V

4000V

AC

24 – 110V AC (D5PF) 6 – 240V AC (D5PR)

6 – 240V AC

6 – 240V AC

24 – 240V AC

DC

24 – 110V DC (D5PF) 6 – 110V DC (D5PR)

6 – 110V DC

12 – 24V DC

12 – 110V DC

2.75 VA 1.2 Watts

3.0 VA (D7PF3, D7PF4) / 2.55 VA 2.3 Watts (D7PF1, D7PF2, D7PF4); 3.4 Watts (D7PF3) / 1.5 Watts

2.5 VA 1.9 Watts

2.6 VA 2.0 Watts

-22 – 122°F (-30° – 50°C) -22 – 212°F (-30° – 100°C)

-40 – 158°F (-40° – 70°C) -40 – 212°F (-40° – 100°C)

-4 – 185°F (-20° – 85°C) -4 – 185°F (-20° – 85°C)

-13 – 140°F (-25° – 60°C) -13 – 140°F (-25° – 60°C)

Maximum Pick-Up

24 Milliseconds

20 Milliseconds (D7PF1, D7PF4) 25 Milliseconds (All Others)

30 Milliseconds

50 Milliseconds

Maximum Release

26 Milliseconds

20 Milliseconds / 25 Milliseconds

30 Milliseconds

50 Milliseconds

5 Million

10 Million

5 Million

1 Million

200,000 (D5PF) / 100,000 (D5PR)

100,000 (D7PR3, D7PR4, D7PF1) 150,000 (D7PF3, D7PF4) 200,000 (D7PF2, D7PR1, D7PR2)

100,000

100,000

49-52 – 49-55

Pages 49-56 – 49-66

Pages 49-67 – 49-70

Pages 49-71, 49-72

Dielectric Strength

Coil Data

Power VA (V AC) Watts (V DC)

General Data

49

Ambient Temperature Operational Storage

Life Mechanical Operations Electrical Operations Page Number

For more information visit: www.eaton.com

CA08102001E

Page 35

Control Relays & Timers General Purpose Plug-In Relays

49-35

July 2008

D2PF Series, Full Featured

D2PF Series

Technical Data and Specifications Table 49-42. D2PF Coil Resistance

D2PF Series Relay

Features

Coil Voltage

Ohms mA 50 Hz

6V AC 6V DC 12V AC 12V DC 24V AC 24V DC 48V DC 110V DC 120V AC 240V AC

9.6 40 46 160 180 650 2600 11000 4430 15700

200 150 100 75 50 37 18 10 10 5

At 60 Hz for AC Coils.

Table 49-43. D2PF2 and D2PF4 Relay Specifications

■ Flag indicator shows relay status in manual or powered condition ■ Bi-polar LED status lamp allows for reverse polarity applications ❑ Shows coil ON or OFF status ❑ Ideal in low light conditions ■ Color coded pushbutton identifies AC coils with red or DC coils with blue pushbuttons ❑ Allows for manual operation of relay without the need for coil power ❑ Ideal for field service personnel to test control circuits ■ Lock down door, when activated, holds pushbutton and contacts in the operate position ❑ Excellent for analyzing circuit problems ■ Finger-grip cover allows operator to remove relays from sockets more easily than conventional relays ■ White plastic I.D. tag/write label used for identification of relays in multi-relay circuits

Standards and Certifications

D2PF2

D2PF4

Resistive Load (p.f. = 1.0)

Inductive Load (p.f. = 1.0)

Coil Pickup Voltage (Max.)

85% AC; 80% DC (% of nominal)

Drop Out Voltage (Min.)

10% AC; 10% DC (% of nominal)

Maximum Voltage

110% of nominal

Insulation System per UL Standard 1446

Class B 266°F (130°C)

Contacts Rated Load

120V AC – 10A 277V AC, 28V DC – 8A (UL), 10A (CSA)

120V AC – 3A 277V AC, 28V DC – 3A

Maximum hp Ratings

1/3 hp, 120V AC 1 hp, 277V AC

1/10 hp, 120V AC 1/10 hp, 277V AC

Contact Material

Silver Tin Oxide (Gold Flashed)

Pilot Duty

Fine Silver, Gold Diffused

B300

Utilization Category (IEC)

AC-15

Min. Permissible Load

100mA @ 5V DC or 0.5W

Contact Resistance

100 Milliohms Max. @ 6V, 1A

Dielectric Strength Coil to Contacts

1500V RMS

Across Open Contacts

1000V RMS

Contacts to Frame

1500V RMS

Insulation Resistance

100 Megohms Min. @ 500V DC

Temperature Operating

-40 – 158°F (-40 – 70°C)

Storage

-40 – 221°F (-40 – 105°C)

Life Expectancy

When used with accompanying Cutler-Hammer® screw terminal UL Listed socket.

CA08102001E

Electrical at Rated Resistive Load

200,000 Operations

Mechanical at No Load

10 Million Operations

Weight Approximate Weight

0.079 lbs. (36G)

For more information visit: www.eaton.com

0.081 lbs. (37G)

49

Page 36

49-36

Control Relays & Timers General Purpose Plug-In Relays July 2008

D2PF Series, Full Featured

Catalog Number Structure

Product Selection

Table 49-44. D2PF Series Catalog Numbering System

Table 49-47. D2PF Product Selection Std. Pack

D2PF 2 A A

Catalog Number

Price U.S. $

DPDT Family Type

Coil Voltage

D2PF Contact Configuration 2 = DPDT 4 = 4PDT Standard Features

A = 120V AC A1 = 110V DC B = 240V AC P= 6V AC P1 = 6V DC R = 12V AC R1 = 12V DC T = 24V AC T1 = 24V DC W1 = 48V DC

A = LED, Test Button, Flag Indicator, Flange Mounting, Lock-Down Door, Finger-Grip Cover, I.D. Tag combinations are readily available.

Table 49-45. D2PF Relay/Socket Quick Reference

12V AC 12V DC

D2PF2AR D2PF2AR1

24V AC 24V DC

D2PF2AT D2PF2AT1

48V DC

D2PF2AW1

110V DC

D2PF2AA1

120V AC

D2PF2AA

240V AC

D2PF2AB

6V AC

D2PF4AP

12V AC 12V DC

D2PF4AR D2PF4AR1

24V AC 24V DC

D2PF4AT D2PF4AT1

48V DC

D2PF4AW1

Hold Down Clip

110V DC

D2PF4AA1

120V AC

D2PF4AA

Screw Terminal

PQC-1342

240V AC

D2PF4AB

D2PA7

Screw Terminal, Finger-Safe

Included with Socket

Sockets and Accessories

D2PA6

Screw Terminal

PQC-1342

4-Pole DIN or Panel Mount Socket

D2PA7

Screw Terminal, Finger-Safe

Included with Socket

Hold Down Clip

10

PQC-1342

4-Pole DIN or Panel Mount Socket, Finger-Safe

10

D2PA7

DIN Rail End Stop

200

PFP-M

Relay Type

Socket

D2PF2

D2PA6

Socket Type

Table 49-46. D2PF Socket Specifications

49

D2PF2AP D2PF2AP1

4PDT

For deciphering Catalog Numbers. Do not use for ordering as not all

D2PF4

6V AC 6V DC

Catalog Number

Electrical Ratings

Mounting Torque

Hook-up Wire Range

D2PA6

10A, 300V

7 – 8 in-lbs. (0.79 – 0.90 Nm)

AWG 14 to 28 Solid or Stranded

D2PA7

10A, 300V

7 – 8 in-lbs. (0.79 – 0.90 Nm)

AWG 14 to 20 Solid or Stranded

10

D2PA6

Additional end stop options available on Page 55-74.

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 For more information visit: www.eaton.com

CA08102001E

Page 37

Control Relays & Timers General Purpose Plug-In Relays

49-37

July 2008

D2PF Series, Full Featured

Dimensions 0.86 (21.8) Max

0.86 (21.8) Max

1.10 (27.9)

1 5 9

4 8 12

13

14

0.10 x 0.02 (2.5 x .5) Typ. 1.10 (27.9)

1

2

3

4

5

6

7

8

9

10

11

12

13

Terminal Arrangement (Bottom View)

0.10 x 0.02 (2.5 x 0.5) Typ.

14

Terminal Arrangement (Bottom View)

0.24 (6.1)

1.61 (40.9) Max.

0.24 (6.1)

1.61 (40.9) Max.

Figure 49-41. D2PF2, Approximate Dimensions in Inches (mm)

Figure 49-42. D2PF4, Approximate Dimensions in Inches (mm)

0.68 1.02 (17.1) (26.0)

2.75 (69.9)

5

1

6

2

7

3

8

4

13

10 11 14

2.53 (64.3) Wiring Diagram (Top View)

1.02 0.72 (25.8) (18.2)

0.66 (16.7)

Figure 49-43. D2PA6, Approximate Dimensions in Inches (mm)

CA08102001E

For more information visit: www.eaton.com

9

12

49

Page 38

49-38

Control Relays & Timers General Purpose Plug-In Relays July 2008

D2PF Series, Full Featured

INPUT

IEC: NEMA:

INPUT

1.17 (29.7)

11 10 1.56 (39.7)

1.16 (29.5)

IEC: NEMA:

INPUT

12

41 A2 14 31 13 21 A1

4

42

3

32 8 44 7 34

2

22

1 12 5 14 6 24

9 11 Wiring Diagram (Top View)

3.12 (79.2)

Figure 49-44. D2PA7, Approximate Dimensions in Inches (mm) 0.86 (22) 0.27 (7.1) 0.23 (6)

1.49 (38)

96° 0.03 (0.8) Dia.

49

0.53 (13.5)

0.04 0.12 (1.1) (3) 0.67 (17.5)

115°

1.18 (30)

Dimensions Calculated Using 0.03 (0.8) Wire Diameter

Figure 49-45. PQC-1342, Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com

CA08102001E

Page 39

Control Relays & Timers General Purpose Plug-In Relays

49-39

July 2008

D2PR Series, Standard

D2PR Series

Table 49-50. D2PR Relay Specifications Resistive Load (p.f. = 1)

Inductive Load (p.f. = 0.4, L/R = 7 ms)

Rated Load

240V AC 5A 30V DC 5A

240V AC 2A 30V DC 2A

Carry Current

5A

5A

Max. Operating Voltage

250V AC/125V DC

250V AC/125V DC

Max. Operating Current

5A

5A

Contact Material

Silver Cadmium Oxide

Silver Cadmium Oxide

Max. Switching Capacity

1100 VA 120W

440 VA 48W

Min. Permissible Load

100 mA, 5V DC

100 mA, 5V DC

Pickup Voltage (max.)

80% AC, 75% DC

80% AC, 75% DC

Drop Out Voltage (min.)

30% AC, 10% DC

30% AC, 10% DC

Voltage (max.)

110%

110%

D2PR2

D2PR Series Relay

Features ■ Ultra-high sensitivity relay with quick response ■ Designed small, 2-pole type break

5A load and 4-pole type, 3A load ■ High reliability, long life ■ Panel, DIN rail and flange mounting ■ Small size

Standards and Certifications File # E37317, E65657

Mechanical Life (min.)

10,000,000 operations

10,000,000 operations

Electrical Life @ All Contact Ratings (min.)

200,000 operations

200,000 operations

Maximum hp Ratings

1/6 hp (120V AC)

1/6 hp (120/240V AC)

Rated Load

240V AC 3A 30V DC 3A

240V AC 0.8A 30V DC 1.5A

Carry Current

3A

3A

Max. Operating Voltage

250V AC/125V DC

250V AC/125V DC

Max. Operating Current

3A

3A

Contact Material

Ag (Au Flashed)

Ag (Au Flashed)

Max. Switching Capacity

660 VA 72W

176 VA 36W

Min. Permissible Load

1 mA, 1V DC

1 mA, 1V DC

Pickup Voltage (max.)

80%

80%

D2PR4

File # LR217017, LR217069

Technical Data and Specifications Table 49-48. D2PR Coil Resistance Coil Voltage

Ohms

6V AC 12V AC 24V AC 48V AC 120V AC 240V AC

11 41 180 788 4430 15700

6V DC 12V DC 24V DC 48V DC 110V DC

40 160 650 2600 11000 mA 50 Hz

60 Hz

234 86.5 48 21 12.9 7

200 74 41 18 11 6 150 75 36.9 18.5 10

Drop Out Voltage (min.)

30% AC, 10% DC

30% AC, 10% DC

Voltage (max.)

110%

110%

Mechanical Life (min.)

10,000,000 operations

10,000,000 operations

Electrical Life @ All Contact Ratings (min.)

200,000 operations

200,000 operations

Maximum hp Ratings

1/10 hp (120/240V AC)

1/10 hp (120/240V AC)

Rated Load

250V AC 5A 30V DC 5A

250V AC 2A 30V DC 2A

Carry Current

3A

3A

Max. Operating Voltage

250V AC/125V DC

250V AC/125V DC

Max. Operating Current

3A

3A

Contact Material

Ag (Au flashed)

Ag (Au flashed)

Max. Switching Capacity

660 VA 72W

176 VA 36W

Min. Permissible Load

100 mA, 1V DC

100 mA, 1V DC

Pickup Voltage (max.)

80%

80%

D2PR5

Table 49-49. D2PR Socket Specifications

Drop Out Voltage (min.)

30% AC, 10% DC

30% AC, 10% DC

Catalog Number

Mounting Hook-Up Torque Wire Range

Set/Reset Voltage (max.)

80%

80%

Voltage (max.)

110%

110%

Mechanical Life (min.)

100 million operations

100 million operations

.785 Nm – AWG 14 1.18 Nm Max.

Electrical Life @ All Contact Ratings (min.)

200,000 operations

200,000 operations

Maximum hp Ratings

1/8 hp (265V AC)

1/8 hp (265V AC)

Electrical Ratings

D2PA4

7A, 250V

D2PA6

10A, 300V 7 – 8 in-lbs AWG 14 to 28 Solid or Stranded

CA08102001E

For more information visit: www.eaton.com

49

Page 40

49-40

Control Relays & Timers General Purpose Plug-In Relays July 2008

D2PR Series, Standard

Catalog Number Structure

Product Selection

Table 49-51. D2PR Series Catalog Numbering System

Table 49-53. D2PR Product Selection Std. Pack

D2PR 2 3 A

Catalog Number

Price U.S. $

Standard DPDT Family Type

Coil Voltage

D2PR Contact Configuration 2 = DPDT 4 = 4PDT 5 = DPDT Latching Options

A = 120V AC A1 = 110V DC B = 240V AC P= 6V AC P1 = 6V DC R = 12V AC R1 = 12V DC T = 24V AC T1 = 24V DC W1 = 48V DC

Coil Voltage: 24V AC 110V AC 240V AC

D2PR2T D2PR2A D2PR2B

12V DC 24V DC

D2PR2R1 D2PR2T1

DPDT with Indicating Light and Test Button 24V AC 110V AC

D2PR23T D2PR23A

24V DC

D2PR23T1

DPDT Flange Mount

3 = Indicating Light and Test Button 4 = Flange Mounting

110V AC

D2PR24A

Standard 4PDT For deciphering Catalog Numbers. Do not use for ordering as not all combinations are readily available.

Table 49-52. D2PR Relay/Socket Quick Reference

Coil Voltage: 24V AC 110V AC

D2PR4T D2PR4A D2PR4R1 D2PR4T1 D2PR4A1

Relay Type

Socket

Hold Down Spring/Clip

12V DC 24V DC 110V DC

D2PR2

D2PA6

PMC-A1

4PDT with Indicating Light and Test Button

D2PR4

D2PA6

PMC-A1

D2PR5

D2PA4

PYC-A1

24V AC 110V AC

D2PR43T D2PR43A

12V DC 24V DC 110V DC

D2PR43R1 D2PR43T1 D2PR43A1

4PDT Flange Mount 110V AC

D2PR44A

DPDT Latching 110V AC

D2PR5A

24V DC

D2PR5T1

DIN Rail or Panel Mount Socket and Accessories

49

4-Pole Socket Spring Clip DIN Rail End Stop

10 100 100

D2PA6 PMC-A1 PFP-M

DIN Rail or Panel Mount Socket and Accessories for D2PR5 Latching Relays 4-Pole Socket Hold-Down Spring DIN Rail End Stop

10 100 100

D2PA4 PYC-A1 PFP-M

Additional coil voltages available, consult Sales Office or Customer

Support Center. Additional end stop options available on Page 55-74.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 For more information visit: www.eaton.com

CA08102001E