Page 41

Control Relays & Timers General Purpose Plug-In Relays

49-41

July 2008

D2PR Series, Standard

Dimensions 0.05 x 0.12 (1.3 x 3.1) Oval Holes

1

4

5

8

9 0.10 (2.5)

12

14 13 Schematic Diagram

0.15 0.15 (3.8) (4.1) Max. Max.

0.02 (0.5)

1.10 (27.9) Max.

1.42 (36.1) Max. 1.66 (42.2) Max.

Max. 0.24 (6.0)

2

10

7

3

11

8

4

0.47 (11.9) Max. 4

5

8

9

12

13

14

0.10 (2.5) 0.02 (0.5)

3

4

5

6

7

8

9

10 11

12

2.75 (69.9) 2.53 (64.3)

1.42 (36.1) Max. 1.65 (41.9) Max.

1.02 0.72 (25.8) (18.2)

0.66 (16.7)

14 13 Schematic Diagram

Figure 49-48. D2PA6, Approximate Dimensions in Inches (mm)

0.17 0.16 (4.3) (4.1)

1.10 (27.9) Max. 0.50 (12.7) 0.25 (6.4)

1

2

3

4

5

6

7

8

9

10

11

12

13

0.91 (23.1) Approx. 0.14 (3.6) Approx.

0.44 (11.2) Approx. 0.16 (4.1) Approx.

14

0.86 (21.8) Max. Terminal Arrangement (Bottom View)

Figure 49-47. D2PR4/D2PR44, Approximate Dimensions in Inches (mm)

1.58 (40.1) Approx. 0.08 (2.0) Max. 2 Places

20° Approx. 0.59 (15.0) Approx.

Figure 49-49. PMC-A1 Spring Clip for D2PA6

CA08102001E

12

0.68 1.02 (17.1) (26.0)

Figure 49-46. D2PR2, Approximate Dimensions in Inches (mm) 2

14

Wiring Diagram (Top View)

1

1

9

1

6

0.86 (21.8) 0.50 (12.6) Max. Max. Terminal Arrangement (Bottom View)

0.05 x 0.12 (1.3 x 3.1) Oval Holes

13

5

For more information visit: www.eaton.com

0.16 (4.1) Approx.

49

Page 42

49-42

Control Relays & Timers General Purpose Plug-In Relays July 2008

D2PR Series, Standard

0.10 (2.5)

AC 4

1

4

14 – 0.05 (1.3) Dia. x 0.09 (2.3) Elliptic Holes

5

8

5

8

0.02 (0.5)

9

12

9

10 11 12

14

13

0.25 1.10 (6.4) (27.9) Max.

10 11

13 RESET

0.85 (21.6) Max.

0.02 (0.5) 1.42 (36.1) Max.

DC

1

0.24 (6.1)

14

SET RESET

R

Terminal Arrangement/Internal Connections (Bottom View)

Figure 49-50. D2PR5, Approximate Dimensions in Inches (mm)

Terminal Arrangement (Top View)

Two 0.17 (4.3) x 0.20 (5.1) Mounting Holes

8

3

2

1

7

6

5

Mounting Holes Two 0.18 (4.6) Dia. or M4 (Two 0.16 (4.1) Dia. or M3)

2.83 (71.9) Max.

2.320 + – 0.004 (58.92 + – 0.10)

12 11 10

1.16 (29.5) Max.

9

0.24 (6.1) 4

0.16 (4.1)

14 13

0.870 + – 0.008 (22.09 + – 0.20)

0.65 (16.5) 1.18 (30.0) Max.

Figure 49-51. D2PA4 Socket for D2PR5 DPDT Latching Relays Only, Approximate Dimensions in Inches (mm) 0.20 (5.1) Max.

M4 Spring Washer M4 x 8 Pan Head Screw

49

0.45 (11.5)

1.43 (36.3)

0.18 (4.6)

0.06 (1.5)

0.18 (4.6)

Figure 49-52. PYC-A1 Hold down Clip for D2PA4 Socket, Approximate Dimensions in Inches (mm)

0.24 (6.2) 0.07 (1.8) 0.07 1.39 (1.8) (35.3)

0.19 (4.8)

1.97 (50.0) 0.39 (10.0)

0.39 (10.0)

0.05 (1.3)

1.47 (37.3)

Figure 49-53. PFP-M DIN Rail End Stop, Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com

CA08102001E

Page 43

Control Relays & Timers General Purpose Plug-In Relays

49-43

July 2008

D3PR/DP3F Series, Standard and Full Featured

D3PR/D3PF Series

Standards and Certifications (CSA approval not applicable to D3PR5 Relays) When used with accompanying Cutler-Hammer® screw terminal socket (for D3PF only). UL Listed

Technical Data and Specifications Table 49-54. Coil Resistance for D3PR Series D3 Series Relay

Coil Voltage

Ohms mA

D3PR2/PR3

Features

D3PR5 – DC (Each Coil)

D3PR2/PR3 – AC

D3PR5 – AC

50 Hz

60 Hz

50 Hz

60 Hz

550 275 137 28 13

458 229 114 23 11, - 13 3.5 1.7, - 11 2.8 1.6

6V AC 12V AC 24V AC 120V AC 240V AC

4.2 18 72 2200 7200, - 6V DC 12V DC 24V DC 48V DC 110V DC

32 120 470 1900 10000, checked by push-to-test button ■ Panel and DIN rail mounting ■ 8- or 11-pin octal plug-in

D3PF

Table 49-55. Coil Resistance for D3PF Series

■ Flag indicator shows relay status in

Coil Voltage

D3PR ■ Compact relay capable of breaking relatively large load currents ■ The contact operation can be easily manual or powered condition ■ LED status lamp shows coil “ON” or “OFF” status, ideal for use in low light applications ■ Push-to-test button allows for manual operation of relay without the need for coil power ■ Lock-down door holds pushbutton and contacts in the operate position when activated ■ Finger-grip cover allows operator to remove relays from sockets easily ■ I.D. tag/write label to identify relays in multiple-relay circuits ■ Bi-polar LED allows for reverse polarity applications

CA08102001E

Ohms

52 1200 3200 88 350, 4000

187 100 50 25 11, 136 69, 27 mA 50 Hz

60 Hz

24V AC 120V AC 240V AC

72 1,700 7,200

398.0 76.0 28.0

340 65 24

12V DC 24V DC 110V DC

120 470 10,000

100.0 49.9 13.2, - - 49

For more information visit: www.eaton.com

Page 44

49-44

Control Relays & Timers General Purpose Plug-In Relays July 2008

D3PR/DP3F Series, Standard and Full Featured Table 49-56. Relay Specifications D3PR2/D3PR3

D3PR2/D3PR3

D3PF2/D3PF3

D3PR5

D3PR5

Resistive Load (p.f. = 1)

Inductive Load (p.f. = 0.4, L/R = 7 ms)

Resistive Load (p.f. = 1.0)

Resistive Load (p.f. = 1)

Inductive Load (p.f. = 0.4, L/R = 7 ms)

Rated Load

240V AC 10A 120V AC 12A 28V DC 10A

240V AC 7A 120V AC 7A 28V DC 7A

240V AC 12A 120V AC 12A 28V DC 12A

240V AC 10A 120V AC 12A 30V DC 10A

240V AC 7A 120V AC 7A 30V DC 7A

Carry Current

10A

10A

12 Amps

10A

10A

Max. Operating Voltage

240V AC/DC

240V AC/DC

110% of nominal

240V AC/DC

240V AC/DC

Contact Resistance

50 milli Ω’s Max. @ 10 Amps 120V AC or 24V DC

50 milli Ω’s Max. @ 10 Amps 120V AC or 24V DC

50 milli Ω’s Max. @ 10 Amps 120V AC or 24V DC

50 milli Ω’s Max. @ 10 Amps 120V AC or 24V DC

50 milli Ω’s Max. @ 10 Amps 120V AC or 24V DC

Dielectric Strength

1500V

1500V

1500V

1500V

1500V

Approx. Weight

3.5 oz (99.2g)

3.5 oz (99.2g)

3.1 oz (88g)

3.5 oz (99.2g)

3.5 oz (99.2g)

-49 – 131°F -22 – 122°F (-30 – 50°C) (-45 – 55°C) AC -49 – 158°F (-45 – 70°C) DC -40 – 221°F (-40 – 105°C) -22 – 212°F (-30 – 100°C)

-49 – 131°F (-45 – 55°C) AC -49 – 158°F (-45 – 70°C) DC -40 – 221°F (-40 – 105°C)

-49 – 131°F (-45 – 55°C) AC -49 – 158°F (-45 – 70°C) DC -40 – 221°F (-40 – 105°C)

Temperature, Operating

Storage

-49 – 131°F (-45 – 55°C) AC -49 – 158°F (-45 – 70°C) DC -40 – 221°F (-40 – 105°C)

Contact Material

AgCdO (Au Flashed)

AgCdO (Au Flashed)

AgCdO (Au Flashed)

AgCdO (Au Flashed)

AgCdO (Au Flashed)

Max. Switching Capacity

2500 VA 280W

1750 VA 196W

12 Amps

1100 VA 72W

440 VA 60W

Min. Permissible Load

100 mA @ 12V

100 mA @ 12V

100 mA

100 mA @ 12V

100 mA @ 12V

Pickup Voltage (max.)

80%

80%

85% AC; 80% DC, - Drop Out Voltage (min.)

10%

10%

30% AC 10% DC, - Set/Reset Voltage (max.), - - 80%

80%

Voltage (max.)

110%

110%

110%

110%

110%

Mechanical Life (min.)

10,000,000

10,000,000

5 million (No Load)

10,000,000

10,000,000

Electrical Life @ All Contact Ratings (min.)

100,000

100,000

200,000 operations at Rated Res. Load

100,000

100,000

Maximum hp Ratings

1/3 hp (120V AC) 1/2 hp (240V AC)

1/3 hp (120V AC) 1/2 hp (240V AC)

1/3 hp, 120V AC 1/2 hp, 240V AC

1/3 hp (120V AC) 1/2 hp (240V AC)

1/3 hp (120V AC) 1/2 hp (240V AC)

Table 49-57. Socket Specifications

49

Catalog Number

Electrical Ratings

Mounting Torque

Hook-Up Wire Range

D3PA2

10A, 600V 15A, 300V

8 – 10 in-lbs

AWG 12 to 22 Solid or Stranded

D3PA3-A2

5A, 600V 15A, 300V

8 – 10 in-lbs

AWG 12 to 22 Solid or Stranded

D3PA6

5A, 600V 16A, 300V

8 – 10 in-lbs

AWG 12 to 20 Solid or Stranded

D3PA7

5A, 600V 16A, 300V

8 – 10 in-lbs

AWG 12 to 20 Solid or Stranded

D3PA4

10A, 260V

N/A

AWG 14 Max.

D3PA5

10A, 260V

N/A

AWG 14 Max.

For more information visit: www.eaton.com

CA08102001E

Page 45

Control Relays & Timers General Purpose Plug-In Relays

49-45

July 2008

D3PR/DP3F Series, Standard and Full Featured

Catalog Number Structure

Product Selection

Table 49-58. D3 Series Catalog Numbering System

Table 49-60. D3 Product Std. Pack

Catalog Number

Coil Voltage: 12V AC 24V AC 120V AC 240V AC

1 1 1 1

D3PR2R D3PR2T D3PR2A D3PR2B

12V DC 24V DC 110V DC

1 1 1

D3PR2R1 D3PR2T1 D3PR2A1

24V AC 120V AC 240V AC

1 1 1

D3PF2AT D3PF2AA D3PF2AB

12V DC 24V DC 110V DC

1 1 1

D3PF2AR1 D3PF2AT1 D3PF2AA1

Coil Voltage: 24V AC 120V AC 240V AC

1 1 1

D3PR3T D3PR3A D3PR3B

12V DC 24V DC 110V DC

1 1 1

D3PR3R1 D3PR3T1 D3PR3A1

24V AC 120V AC 240V AC

1 1 1

D3PF3AT D3PF3AA D3PF3AB

24V DC 110V DC

1 1

D3PF3AT1 D3PF3AA1

1 1

D3PR5T D3PR5A

10 1 10 1

D3PA2 D3PA6 D3PA3 D3PA7

10 10

D3PA4 D3PA5

10 25 10 100 25

PQC-1344 PQC-1332 PQC-1351 PWC-1325 D3PJ1

100

PFP-M

D3PR 2 3 A

Price U.S. $

Standard DPDT with Test Button Family Type

Coil Voltage

D3PR, Standard Relay D3PF, Full Featured Relay

A = 120V AC A1 = 110V DC B = 240V AC P= 6V AC P1 = 6V DC R = 12V AC R1 = 12V DC T = 24V AC T1 = 24V DC W1 = 48V DC

Contact Configuration 2 = DPDT (8-Pin) 3 = 3PDT (11-Pin) 5 = DPDT Latching (11 Pin) Options Blank = Relay with Test Button A = LED, Test Button, Flag Indicator, LockDown Door, Finger-Grip Cover, I.D. Tag

DPDT Full Featured Relay

Standard 3PDT with Test Button For deciphering Catalog Numbers. Do not use for ordering as not all combinations are readily available. D3PR only.

Table 49-59. Relay/Socket Quick Reference Relay Type

Socket Type

Socket

Hold Down Spring/Clip

D3PR2

8 Pin Octal

D3PA2 D3PA4 D3PA6

PQC-1344 Not Available PQC-1332

D3PF2

D3PR3

D3PF3

D3PR5

8 Pin Octal

D3PA2

PQC-1344

8 Pin Octal, Finger-safe terminals

D3PA6

PQC-1332

11 Pin Octal

D3PA3-A2 D3PA5 D3PA7

PQC-1351 Not Available PQC-1332

3PDT Full Featured Relay

DPDT Latching 24V AC 120V AC

11 Pin Octal

D3PA3-A2

PQC-1351

DIN Rail Sockets

11 Pin Octal, Finger-safe terminals

D3PA7

PQC-1332

11 Pin Octal

D3PA3-A2 D3PA5 D3PA7

PQC-1351 Not Available PQC-1332

2-Pole (8-Pin) 2-Pole (8-Pin) Finger-Safe - 3-Pole (11-Pin) 3-Pole (11-Pin) Finger-Safe -

Panel Mount Sockets 2-Pole 3-Pole

Accessories Hold Down Clip Hold Down Clip Hold Down Clip Hold Down Clip Coil Buss Jumper for D3PA6 & D3PA7 DIN Rail End Stop

Additional coil voltages available, consult Sales Office or Customer

Support Center. Dimensions on Page 49-51. CSA approval is not applicable to D3PR5 Latching Relays. - IP20 Rated.

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 CA08102001E

For more information visit: www.eaton.com

49

Page 46

49-46

Control Relays & Timers General Purpose Plug-In Relays July 2008

D3PR/DP3F Series, Standard and Full Featured

Dimensions 6-32 x 0.312 Combination Head Screw and Pressure Clamping Plate (8 Places)

Terminal Arrangement 2 1 8 7

Two 0.165 (4.2) Dia. Slots

2.14 (54.3) 2.03 (51.4)

3 4 5 6 1.30 (32.9) 1.60 (40.5) Max.

0.82 (20.8) 0.58 (14.7) 0.97 (24.6) Tolerances: ± 0.010 Max. ± (0.25) Unless Otherwise Shown

Figure 49-54. D3PA2, Approximate Dimensions in Inches (mm) 1.37 (34.8) Max.

0.03 (0.8)

2.33 (59.2) Max.

1.37 (34.8) Max.

2.25 (57.2) Max. 1.37 (34.8) Max.

1.37 (34.8) Max.

RESET

RESET

(+) 6

5

8

1

6

3 5

49

2 10 9 3 4 8 7 6 5

2

7

(–)

11 1

4

D3PR2 Terminal Arrangement (Bottom View)

4

8

4

3

9

3

(–) 2 1

11

10 (+)

COM

7 8 9

2

10 1

11

OPERATE

OPERATE

DC Operated

AC Operated Single Wound AC Coil Recommended diodes used in AC versions 1N4007 or equivalent.

D3PR3

Figure 49-55. D3PR2/D3PR3, Approximate Dimensions in Inches (mm)

6

5

7

Figure 49-56. D3PR5, Approximate Dimensions in Inches (mm)

Terminal Arrangement

6-32 x 0.312 Combination Head Screw and Pressure Clamp (11 Places)

2 1 11 10 Two 0.17 (4.3) Dia. Holes

2.05 (52.07) Max.

9

3

4 2.06 (52.3)

0.125 – 0.156 (3.17 – 3.96))

0.15 (3.6) 0.58 (14.7) 0.77 (19.6)

5 6 7 8

2.33 (59.1) 0.97 Max. (24.6) Tolerances: ± 0.010 ± (0.25) Unless Otherwise Shown

Figure 49-57. D3PA3-A2, Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com

CA08102001E

Page 47

Control Relays & Timers General Purpose Plug-In Relays

49-47

July 2008

D3PR/DP3F Series, Standard and Full Featured

A2 INPUT 10

A1 INPUT 2 1

11

2

9

4

8 9

5

7

6 IEC: NEMA:

11 34

6 7

8 31

24

32

21 5 22

D3PJ1

3.01 (76.5)

10

3

3 1 14 4 11 12

Bottom View

Break-Away Terminals

0.09 (2.3)

0.10 (2.5) Max.

0.13 (3.3) Max.

0.64 (16.2)

0.02 (0.6)

1.26 (32.0) 1.40 (35.6)

0.32 (8.1)

1.44 (36.6)

1.50 (38.1)

Figure 49-61. D3PA7, Approximate Dimensions in Inches (mm)

1.99 1.57 (50.5) (39.9) Max.

2 – 0.08 (2.0) Dia. Holes

1.18 (30.0) Dia.

0.15 (3.8)

0.14 (3.6)

Figure 49-58. D3PJ1, Approximate Dimensions in Inches (mm)

1.32 (33.5) Max.

0.79 (20.1) Max.

1.55 (39.4) 0.33 (8.4)

2 – 0.14 (3.6) Dia. Mounting Holes or 2 – M3 Mounting Screw Holes

2.14 2.00 (54.4) (50.8)

2.20 (55)

1.22 (31.0) Dia. Holes Mounting Holes

90°

1.00 (25.4)

2.26 (57.4)

D3

1.57 (39.9)

Bottom View

PL

Figure 49-62. D3PA4, Approximate Dimensions in Inches (mm)

20° 2 – 0.08 (2.0) Dia. Holes

0.15 (3.8)

0.14 (3.5) Max.

2.01 1.57 1.18 (51.1) (39.9) (30.0) Dia. Max.

Figure 49-59. PQC-1332, Approximate Dimensions in Inches (mm)

0.15 (3.8)

0.24 (6.1) 0.04 (1.01) 0.14 (3.6)

A2 INPUT 7

A1 INPUT 2

IEC: NEMA:

1

8

4

5

2

2 – 0.14 (3.6) Dia. Mounting Holes or 2 – M3 Mounting Screw Holes

3.01 (76.5)

7

3

6

8

6

21

24

1

5 22

1.41 (35.8)

1.22 (31.0) Dia. Holes Mounting Holes

D3 Bottom View

PL

Figure 49-63. D3PA5, Approximate Dimensions in Inches (mm)

11

3 14 4 12

Figure 49-60. D3PA6, Approximate Dimensions in Inches (mm)

CA08102001E

2.26 (57.4)

1.57 (39.9)

Bottom View 1.44 (36.6)

0.83 (21.1) Max

1.38 (35.1) Max.

For more information visit: www.eaton.com

49

Page 48

49-48

Control Relays & Timers General Purpose Plug-In Relays July 2008

D3PR/DP3F Series, Standard and Full Featured

1.38 (34.9) Max. 8 8

11

1

2

6

3

7

2 3

6

4

2

2

10 9

3

8

4 7

5

Schematic Diagram

1.40 (35.6) Max.

6

3

9

4

5

8

4

1.32 (33.5) Max.

Schematic Diagram

1.40 (35.6) Max.

5 7

Terminal Arrangement (Bottom View)

1

10

1

11

1

7

5

1.38 (35.1) Max.

6

Terminal Arrangement (Bottom View)

1.32 (33.5) Max.

Plastic ID Tag

Plastic ID Tag 1.35 (34.3) Max.

1.35 (34.3) Max.

2.25 (57.2) Max. 2.28 (57.9) Max.

0.54 (13.7) Max.

Figure 49-64. D3PF2, Approximate Dimensions in Inches (mm)

2.25 (57.2) Max. 2.28 (57.9) Max.

0.54 (13.7) Max.

Figure 49-65. D3PF3, Approximate Dimensions in Inches (mm)

49

For more information visit: www.eaton.com

CA08102001E

Page 49

Control Relays & Timers General Purpose Plug-In Relays

49-49

July 2008

D4 Series, Standard

D4 Series

Features ■ Slim-styled power relay

Technical Data and Specifications

■ Socket has built-in hold-down clip

Table 49-61. Coil Resistance

■ Panel or DIN rail mounting

Coil Voltage

Standards and Certifications File # E1491, E65657 File # LR701519 D4 Series Relay

Ohms mA @ 60 Hz AC

6V AC 12V AC 24V AC 48V AC 110/120V AC 220/240V AC

16 65 260 1130 6500 30000

150 75 37.5 18 7.5 3.8

6V DC 12V DC 24V DC 48V DC 100/110V DC

68 275 1100 4170 22900

88.2 43.6 21.8 11.5 4.8

Table 49-62. Specifications D4PR1

D4PR2

Resistive Load (p.f. = 1)

Inductive Load (p.f. = 0.4, L/R = 7 ms)

Resistive Load (p.f. = 1)

Inductive Load (p.f. = 0.4, L/R = 7 ms)

Rated Load

250V AC 10A 30V DC 10A

250V AC 7.5A 30V DC 5A

240V AC 5A 30V DC 5A

250V AC 2A 30V DC 3A

Carry Current

10A

10A

5A

5A

Max. Operating Voltage

380V AC/125V DC

380V AC/125V DC

380V AC/125V DC

380V AC/125V DC

Max. Operating Current

10A

10A

5A

5A

Contact Material

AgCdO

AgCdO

AgCdO

AgCdO

Max. Switching Capacity

2500 VA 300W

1875 VA 150W

1250 VA 150W

500 VA 90W

Min. Permissible Load

100 mA, 5V DC

100 mA, 5V DC

10 mA, 5V DC

10 mA, 5V DC

Pickup Voltage (max.)

80% AC/70% DC

80% AC/70% DC

80% AC/70% DC

80% AC/70% DC

Drop Out Voltage (min.)

30% AC/15% DC

30% AC/15% DC

30% AC/15% DC

30% AC/15% DC

Voltage (max.)

110%

110%

110%

110%

Mechanical Life (min.)

10,000,000 AC/20,000,000 DC

10,000,000 AC/20,000,000 DC

10,000,000 AC/20,000,000 DC

10,000,000 AC/20,000,000 DC

Electrical Life @ All Contact Ratings (min.)

100,000

100,000

100,000

100,000

Maximum hp Ratings

1/3 hp (125V AC) 1/2 hp (250V AC) 1/2 hp (277V AC)

1/3 hp (125V AC) 1/2 hp (250V AC) 1/2 hp (277V AC)

1/6 hp (120V AC) 1/3 hp (240V AC) 1/3 hp (265V AC)

1/6 hp (120V AC) 1/3 hp (240V AC) 1/3 hp (265V AC)

CA08102001E

For more information visit: www.eaton.com

49

Page 50

49-50

Control Relays & Timers General Purpose Plug-In Relays July 2008

D4 Series, Standard

Catalog Number Structure

Product Selection

Table 49-63. D4 Series Catalog Numbering System

Table 49-65. D4 Product Selection Std. Pack

D4PR 1 1 A

Catalog Number

Price U.S. $

Standard SPDT Family Type

Coil Voltage

D4PR

A = 120V AC A1 = 110V DC B = 240V AC P= 6V AC P1 = 6V DC R = 12V AC R1 = 12V DC T = 24V AC T1 = 24V DC W1 = 48V DC

Contact Configuration 1 = SPDT 2 = DPDT Options 1 = Indicating Light

For deciphering Catalog Numbers. Do not use for ordering as not all combinations are readily available.

Coil Voltage: 24V AC 120V AC

D4PR1T D4PR1A

24V DC

D4PR1T1

SPDT with Indicating Light 24V AC 120V AC

D4PR11T D4PR11A

24V DC

D4PR11T1

Standard DPDT 24V AC 120V AC

D4PR2T D4PR2A

12V DC 24V DC

D4PR2R1 D4PR2T1

DPDT with Indicating Light

Table 49-64. Relay/Socket Quick Reference

120V AC

D4PR21A

Relay Type

Socket

Hold Down Clip

24V DC

D4PR21T1

D4PR1

D4PA1

DIN Rail Sockets

D4PR2

D4PA2

1-Pole 2-Pole

Socket has built-in hold down spring.

10 10

D4PA1 D4PA2

100

PFP-M

Accessories DIN Rail End Stop

Additional coil voltages available, consult Sales Office or Customer

Support Center.

49

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 For more information visit: www.eaton.com

CA08102001E