Page 51

PCM-11 Input/Output Functions PCM-11 Input Functions

35

Clear End Program Count

Clears the End Of Program Count output. If not assigned, the End Of Program Count output will automatically clear when the next motion occurs. If this input is assigned, an input is required to clear the output. 36

Clear All Prog Outputs

When the line assigned to this function is activated, this function will clear (set to OFF) all programmable output lines. ( See Input function #27 to clear individual programmable output lines.) 78

Clear Program Error

This input is used to clear the Program Error output (Output Function #46). If this function is assigned, this input is required to clear the output.

45

Page 52

PCM-11 Application Module Operator's Manual

PCM-11 Output Functions The following list of output functions are available in addition to the output functions listed in the “FX Drives Setup and Programming Operator’s Manual” (P/N 400282-00) when a PCM-11 is employed with an FX Drive. 11

End Of Sequence

This output comes On after the completion of a motion sequence before the last dwell time (if any). A motion sequence is completed when a Home, Index, and/or Program or a combination thereof, is executed and no further motion commands are given. This output turns OFF automatically with the next motion or when the Clear End Of Sequence is used. 12

Programmable Outputs

The output lines assigned this function can be turned On or Off with the Update Outputs programming function. 13

End Of Program

This output is activated after each completion of all steps (motion and non-motion) in a Program. It is automatically deactivated with the next motion or when the Clear End Of Program input is used. 14

End Of Program Count

This output is activated only after a program is executed the number of times specified by the Program Count. It is automatically deactivated with the next motion or when the Clear End Of Program Count is used. 15

In Suspend

This output is activated when the Suspend Program function is active. Also see Suspend/Resume Functions section of this manual for a complete discussion. 16

End of Home (1)

This output comes On after the completion of a Home 1 cycle. It is turned Off automatically with the next motion or when the Clear End Of Home input is used. 45

Out Of Index

This output is activated if the motor moves past the end of an index during a fault initiated suspend. It will also be activated if the motor has moves past the fault position.

46

Page 53

PCM-11 Input/Output Functions PCM-11 Output Functions

46

Program Error

This output is activated when a math error occurs in a program, however, program execution is not interrupted. You can view the diagnostics screen by pressing the <F10> key to determine the type of math error. This output is cleared using the Clear Program Error Input.

47

Page 54

PCM-11 Application Module Operator's Manual

48

Page 55

Appendix A - List of Figures

Appendix A List of Figures Overview-PCM-11 Motion Program Controller Navigating PCX Software

Figure 1

PCX Hierarchy Diagram 1...................................................... 3

Figure 2

PCX Hierarchy Diagram 2...................................................... 4

Installing Your PCM-11

Figure 3

PCM-11 Connection to an FX Drive....................................... 6

PCM-11 Features

Figure 4

Drive Parameters Screen........................................................ 8

Figure 5

Global External Input Time Limit Setup .............................. 9

Figure 6

Hardware (External) Input Line Assignments ..................... 9

Figure 7

Software (Internal) Input Line Assignments ...................... 10

Figure 8

Internal Output Line Assignments...................................... 10

Figure 9

Internal Output Line Assignments...................................... 11

Figure 10

Output Connection to an Input Line.................................... 12

Figure 11

Programmable Limit Switches ............................................. 13

Figure 12

User Registers Setup Screen ................................................ 15

Figure 13

Equations Screen .................................................................. 17

Figure 14

Messages Screen ................................................................... 18

Building Your Program Figure 15 Motion Program Example..................................................... 20

Figure 16

Program Example ................................................................. 20

Figure 17

Program Example ................................................................. 21

Figure 18

Compound Index Example #1............................................... 22

Figure 19

Example #2, Compound Index Motion Profile..................... 22

Figure 20

Compound Index Example #3............................................... 23

Figure 21

Programmable Output Options............................................ 24

Figure 22

Jump Command Options ...................................................... 26

Figure 23

“Jump If” Options.................................................................. 26

Figure 24

Jump/Wait Single Input ....................................................... 27

Figure 25

Jump Command Options ...................................................... 27

Figure 26

Wait for Input Command Options ....................................... 28

Figure 27

Load Value Setup Options .................................................... 29

A-1

Page 56

PCM-11 Application Module Operator's Manual

Figure 28

Read Drive Parameters ........................................................ 31

Figure 29

Sample Program Using a Conditional Branch .................... 32

Suspend/Resume Functions Figure 30

A-2

Suspend Screen ..................................................................... 40