Page 51
PCM-11 Input/Output Functions PCM-11 Input Functions
35
Clear End Program Count
Clears the End Of Program Count output. If not assigned, the End Of Program Count output will automatically clear when the next motion occurs. If this input is assigned, an input is required to clear the output. 36
Clear All Prog Outputs
When the line assigned to this function is activated, this function will clear (set to OFF) all programmable output lines. ( See Input function #27 to clear individual programmable output lines.) 78
Clear Program Error
This input is used to clear the Program Error output (Output Function #46). If this function is assigned, this input is required to clear the output.
45
Page 52
PCM-11 Application Module Operator's Manual
PCM-11 Output Functions The following list of output functions are available in addition to the output functions listed in the “FX Drives Setup and Programming Operator’s Manual” (P/N 400282-00) when a PCM-11 is employed with an FX Drive. 11
End Of Sequence
This output comes On after the completion of a motion sequence before the last dwell time (if any). A motion sequence is completed when a Home, Index, and/or Program or a combination thereof, is executed and no further motion commands are given. This output turns OFF automatically with the next motion or when the Clear End Of Sequence is used. 12
Programmable Outputs
The output lines assigned this function can be turned On or Off with the Update Outputs programming function. 13
End Of Program
This output is activated after each completion of all steps (motion and non-motion) in a Program. It is automatically deactivated with the next motion or when the Clear End Of Program input is used. 14
End Of Program Count
This output is activated only after a program is executed the number of times specified by the Program Count. It is automatically deactivated with the next motion or when the Clear End Of Program Count is used. 15
In Suspend
This output is activated when the Suspend Program function is active. Also see Suspend/Resume Functions section of this manual for a complete discussion. 16
End of Home (1)
This output comes On after the completion of a Home 1 cycle. It is turned Off automatically with the next motion or when the Clear End Of Home input is used. 45
Out Of Index
This output is activated if the motor moves past the end of an index during a fault initiated suspend. It will also be activated if the motor has moves past the fault position.
46
Page 53
PCM-11 Input/Output Functions PCM-11 Output Functions
46
Program Error
This output is activated when a math error occurs in a program, however, program execution is not interrupted. You can view the diagnostics screen by pressing the <F10> key to determine the type of math error. This output is cleared using the Clear Program Error Input.
47
Page 54
PCM-11 Application Module Operator's Manual
48
Page 55
Appendix A - List of Figures
Appendix A List of Figures Overview-PCM-11 Motion Program Controller Navigating PCX Software
Figure 1
PCX Hierarchy Diagram 1...................................................... 3
Figure 2
PCX Hierarchy Diagram 2...................................................... 4
Installing Your PCM-11
Figure 3
PCM-11 Connection to an FX Drive....................................... 6
PCM-11 Features
Figure 4
Drive Parameters Screen........................................................ 8
Figure 5
Global External Input Time Limit Setup .............................. 9
Figure 6
Hardware (External) Input Line Assignments ..................... 9
Figure 7
Software (Internal) Input Line Assignments ...................... 10
Figure 8
Internal Output Line Assignments...................................... 10
Figure 9
Internal Output Line Assignments...................................... 11
Figure 10
Output Connection to an Input Line.................................... 12
Figure 11
Programmable Limit Switches ............................................. 13
Figure 12
User Registers Setup Screen ................................................ 15
Figure 13
Equations Screen .................................................................. 17
Figure 14
Messages Screen ................................................................... 18
Building Your Program Figure 15 Motion Program Example..................................................... 20
Figure 16
Program Example ................................................................. 20
Figure 17
Program Example ................................................................. 21
Figure 18
Compound Index Example #1............................................... 22
Figure 19
Example #2, Compound Index Motion Profile..................... 22
Figure 20
Compound Index Example #3............................................... 23
Figure 21
Programmable Output Options............................................ 24
Figure 22
Jump Command Options ...................................................... 26
Figure 23
“Jump If” Options.................................................................. 26
Figure 24
Jump/Wait Single Input ....................................................... 27
Figure 25
Jump Command Options ...................................................... 27
Figure 26
Wait for Input Command Options ....................................... 28
Figure 27
Load Value Setup Options .................................................... 29
A-1
Page 56
PCM-11 Application Module Operator's Manual
Figure 28
Read Drive Parameters ........................................................ 31
Figure 29
Sample Program Using a Conditional Branch .................... 32
Suspend/Resume Functions Figure 30
A-2
Suspend Screen ..................................................................... 40