PCM-11 Application Module Operator's Manual
Manual56 pagesPDF 3.6 MB
Operator's manual for the Emerson EMC PCM-11 motion program controller module for FX positioning servo drives.
Covers · 1 model
The models it covers
Summary
What is in it
Emerson EMC's operator's manual for the PCM-11 Motion Program Controller, an application module that attaches to the front of an FX positioning servo drive and lets you combine indexes, dwell times and other functions into complete motion programs. It covers navigating the PCX software, installing and wiring the module's inputs and outputs, its features (axis ID, internal I/O, programmable limit switches, user registers, equations, messages), every programming function, suspend/resume functions and the input and output functions.
Its parts
- Overview-PCM-11 Motion Program Controller
- Navigating PCX Software
- Installing Your PCM-11
- PCM-11 Features
- Building Your Program
- Suspend/Resume Functions
- PCM-11 Input/Output Functions
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
This is the Emerson EMC PCM-11 Application Module Operator's Manual, part number 400283-00, revision A2, dated September 1, 1995. The PCM-11 Motion Program Controller attaches to the front of an FX positioning servo drive and lets the drive run motion programs built from indexes, dwells, I/O and math steps. The manual covers installing and wiring the module, setting up its features in PCX software, the programming functions, suspend and resume, and the extra input and output functions.
- What it is
- Motion program controller module that attaches to the front of an Emerson EMC FX positioning servo drive p. 7
- Indexes
- 256 indexes (32 in the base FX drive) p. 7
- Program capacity
- 1,024 program steps for all programs combined; up to 255 steps in a single program p. 7, 23
- Hardware I/O
- 8 input lines and 4 output lines, optically isolated for +10.5 to +30 VDC p. 11
- Output rating
- Each output sinks or sources up to 200 mA p. 11
- I/O terminals
- Inputs on terminal pairs 13-20, outputs on pairs 21-24; 2 screw terminals per line for sinking or sourcing p. 11
- Input threshold
- Minimum 2 mA at 10.5 VDC for 3 to 7 ms; maximum 30 VDC p. 49
- I/O wire size
- 18 to 24 gauge p. 11
- Drive connection
- Attaches with two locking arms; all connections except I/O through the 48 pin connector p. 11
- Internal I/O
- 16 internal inputs and 16 internal outputs; 32 inputs and 24 outputs in total per FX drive with a PCM-11 p. 15
- Firmware
- Revision A5 or higher needed for all features; shown in the REV field of the serial number sticker p. 7
- Software
- PCX software version 6.5 or above; FX drive manual P/N 400282-00 p. 8
- Fault codes
- 1: RMS current or continuous torque exceeded; 5: motor temperature; 6: bridge circuit breaker open or low AC voltage; 7: amplifier bridge temperature; F: following error p. 47
- Limit switches
- Programmable limit switch patterns at up to 16 motor positions, using up to 16 output lines p. 18
What this manual walks you through
- Installing the PCM-11 and wiring sinking or sourcing inputs and outputs p. 11, 12
- Moving the module and its setup to another FX drive p. 8
- Setting a global time limit for wait-for-input steps p. 14
- Using internal input and output lines p. 15
- Setting up programmable limit switches p. 18
- Entering math equations and handling program errors p. 23
- Calling and nesting programs p. 31
- Suspending a program automatically on a fault p. 47
- Selecting and starting programs with input lines p. 49, 50
- PCM-11 output functions such as End Of Sequence and Program Error p. 52, 53
Good to know
- Use only 18 to 24 gauge wire for I/O; the manual says larger gauge wire will cause the I/O terminals to fatigue early. p. 11
- Output current must be limited to 200 mA or less per line. p. 11
- Inductive loads such as DC relay coils need a suppression diode in parallel with the coil. p. 11
- The (-) lead of the external I/O power supply must be connected to enclosure or safety ground. p. 11
- Nested program calls that loop can stack up memory and drop the drive out of the program or cause a fault. p. 31
Questions this manual answers
Which PCM-11 faults can trigger Suspend Upon Fault?
Faults 1 (RMS current or continuous torque), 5 (motor temperature), 6 (bridge breaker open or low AC voltage), 7 (bridge temperature) and F (following error). p. 47
How many inputs and outputs does the PCM-11 add?
It adds 8 hardware inputs and 4 hardware outputs, plus 16 internal inputs and 16 internal outputs. p. 11, 15
What PCM-11 firmware revision do I need?
Revision A5 or higher for all features in the manual; the revision is in the REV field of the sticker on the side of the module. p. 7
How do I select a program with PCM-11 input lines?
Assign Program Select Lines, which are binary weighted, then activate the Program Initiate input; four lines select programs 0 through 15. p. 50
What does the PCM-11 Program Error output mean?
A math error occurred in a program, which keeps running; press F10 to see the diagnostics and clear it with the Clear Program Error input. p. 53