Page 1
PCM-11 Application Module Operator’s Manual
Page 2
Page 3
PCM-11 Application Module Operator’s Manual
Information furnished by EMERSON EMC is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON EMC for its use. EMERSON EMC reserves the right to change the design or operation of the equipment described herein and any associated motion products without notice. EMERSON EMC also assumes no responsibility for any errors that may appear in this document. Information in document is subject to change without notice.
P/N 400283-00
Rev.: A2 Date: Sept. 1, 1995 i
Page 4
Customer Services: EMERSON EMC offers a wide range of services to support our customer’s needs. Listed below are some examples of these services.
Service Support (612) 474-8833 Emerson Electronic Motion Control’s products are backed by a team of professionals who will service your installation wherever it may be. Our customer service center in Minneapolis, Minnesota is ready to help you solve those occasional problems over the telephone. Our customer service center is available 24 hours a day for emergency service to help speed any problem solving. Also, all hardware replacement parts, should they ever be needed, are available through our customer service organization. Need on-site help? Emerson EMC provides on-site service, in most cases, the next day. Just call Emerson EMC’s customer service center when on-site service or maintenance is required.
Training Services (612) 474-1116 Emerson EMC maintains a highly trained staff of instructors to familiarize customers with Emerson EMC’s products and their applications. A number of courses are offered, many of which can be taught in your plant upon request.
Application Engineering (612) 474-1116 An experienced staff of factory application engineers provide complete customer support for tough or complex applications. Our engineers offer you a broad base of experience and knowledge of electronic motion control applications.
Bulletin Board System (612) 474-8835 Emerson EMC maintains a BBS which provides you access to software updates, and technical information and services. Communications protocol:
FAX (612) 474-8711 ii
300-14,400 baud, N, 8, 1
Page 5
Table of Contents
Table of Contents Customer Services:............................................................................... ii Overview-PCM-11 Motion Program Controller.................................. 1 Navigating PCX Software.................................................................... 3 Installing Your PCM-11....................................................................... 5 Inputs ................................................................................................ 5 Outputs ............................................................................................. 5 PCM-11 Features ................................................................................. 7 Axis ID Description........................................................................... 7 Axis ID Setup ................................................................................. 7 Global External Input Time Limit................................................... 8 Global External Input Time Limit Setup..................................... 8 Internal Input and Output Lines..................................................... 9 Internal Input/Output Setup ...................................................... 11 Programmable Limit Switches (PLS) ............................................ 12 PLS Setup .................................................................................... 13 User Registers................................................................................. 14 User Registers Setup ................................................................... 15 Equations ........................................................................................ 16 Equation Setup ............................................................................ 17 User Messages ................................................................................ 18 Messages Setup ........................................................................... 18 Building Your Program...................................................................... 19 Programming Functions ................................................................. 21 C Compound Next Index ................................................................ 21 D Dwell Time ................................................................................. 23 E End Program ............................................................................... 23 F Set Maximum Following Error .................................................. 24 H Call Home.................................................................................... 24 I Call Index...................................................................................... 24 O Set Outputs ................................................................................ 24 P Call Program................................................................................ 25 Q Set Maximum Torque Output ................................................... 25 J, W Jump/Wait .............................................................................. 26 Using Jump/Wait Statements in a Program.............................. 26 Jump Commands ......................................................................... 27 Wait For Input Commands ........................................................ 28 / + - * ^ Math Operators ............................................................. 29 Using Math Operators in a Program.......................................... 29 = Load Value ................................................................................... 30 Using Load Value in a Program ................................................. 30 B Conditional Branches.................................................................. 31 Using Conditional Branches in a Program ................................ 32 DC Drive Command........................................................................ 32 Using Drive Commands in a Program ....................................... 33 I, PJ Program Index, Program Jog ................................................ 33 LB Labels ........................................................................................ 35 Using a Label in a Program ........................................................ 35 iii
Page 6
PCM-11 Application Module Operator's Manual
M Math Equation............................................................................ 35 Using Math Equations in a Program ...................................... 35 RT Real-Time Clock ........................................................................ 36 ST Stop Motion ............................................................................... 36 Using the Stop Motion Command in a Program .................... 36 WI Write Index, WJ Write Jog....................................................... 37 Using WJ Write Jog in a Program .......................................... 37 Using WI Write Index in a Program ....................................... 37 Transmit Data (X)........................................................................... 38 Suspend/Resume Functions............................................................... 39 Suspend Screen Parameters .......................................................... 39 Run Program On Suspend ...................................................... 40 Program Number...................................................................... 40 Automatically Clear After Program ........................................ 40 Automatically Resume ............................................................. 40 Automatically Return After Resume....................................... 40 Automatically Suspend Upon Fault ........................................ 41 PCM-11 Input/Output Functions ..................................................... 43 PCM-11 Input Functions ................................................................ 43 PCM-11 Output Functions ............................................................. 46 Appendix A - List of Figures.............................................................A-1 iv
Page 7
Overview-PCM-11 Motion Program Controller
Overview-PCM-11 Motion Program Controller This manual provides setup and programming information for the PCM-11 Motion Program Controller. The PCM-11 Motion Program Controller is an Application Module that attaches to the front of any EMERSON EMC FX Postioning Servo Drive and adds the ability to combine indexes, dwell times, and other functions to form a complete motion sequence, or “program”. The features provided by the PCM-11 Motion Program Controller include:
• • •
256 indexes (as opposed to 32 indexes in the base FX drive)
•
Wait to continue function that halts program flow until selected internal and/or external input lines become active
•
Jump function to other parts of the program depending on the condition of the selected internal and/or external input lines
•
Programmable internal and external output lines that become active depending on program instructions
• • • •
Programmable Limit Switch option for programmable output lines
99 programs and a maximum of 1,024 program steps Dwell times between any two program steps (not just between indexes as in the basic FX drive)
Change maximum following error function during a program Change maximum torque function during a program Suspend/Resume Programfunction that records existing program data at time of interruption and permits later completion of the interrupted program.
•
Compound Index function that changes motor velocity at completion of compounded index distance to velocity of next index without stopping
•
Logic, math, and branching functions that control program flow based on current conditions
• and many more.
The firmware revision on a PCM-11 module necessary for all of the programming features in this manual is A5 or higher. You can find the revision number of your module by looking at the serial number sticker located on the side of the module. The revision number is found in the “REV” field. The PCX version that is shipped with this Application Module will work with previous revisions of EMERSON EMC Application Modules and FX Drives. However, some of the features described in this manual will not be available for use with earlier equipment and will not appear on screen when on-line with PCX6.05.
1
Page 8
PCM-11 Application Module Operator's Manual
It is important that you become familiar with “PCX Software Setup and Operation” in the FX Drive Operator’s Installation and Programming Manual (P/N 400282-00). It provides the basic information needed to set up and program the FX drive using PCX software (ver. 6.5 or above). The FX Drive’s firmware is disabled whenever an Application Module such as the PCM-11 Motion Program Controller is attached. Therefore, the FX Drive’s firmware can be any version since the programming features reside in the Application Module’s non-volatile memory. The PCM-11 stores FX Drive setup parameters within the PCM-11 module. This allows you to transfer the PCM-11 to another FX Amplifier without losing setup parameters.
2
Page 9
Navigating PCX Software
Navigating PCX Software Adding a PCM-11 Motion Program Controller to an FX Drive gives you several additional features in PCX. The hierarchy menu diagrams in Figures 1 and 2 show the additional features in the shaded blocks.
Figure 1 PCX Hierarchy Diagram 1
3
Page 10
PCM-11 Application Module Operator's Manual
Figure 2 PCX Hierarchy Diagram 2 Drive Setup Motion Configuration Output DN, N Func ions Indexes Input Fome - Functions y Limits Drive Jog Parameters FX Basic Drive User Messages * Equations User Registers Suspend ‘N Programs Programmable
Limit Switches
PCM-11 Application Module