Page 71

1 . VS-606PO3 INVERTER MAIN UNIT (Cont'd) 1 .10 OPTIONS AND PERIPHERAL UNITS 1 .10 .1 Optional Units Model (Code No)

Function

Installing Position

VS Operator * (Small Plastic Version)

JVOP-95-"_; (73041- -, 0905X-~_; )

An exclusive control panel for remotely setting frequency and for turning the unit ON/OFF using analog commands (distance up to 50 m). Scale on the frequency meter : 60/120 Hz, 90/180 Hz

Separately installed

VS Operator * (Standard Version)

JVOP-96- -, -; t (730410906X-1-)

An exclusive control panel for remotely setting frequency and for turning the unit ON/OFF using analog commands (distance up to 50 m). Scale on the frequency meter : 75 Hz, 150 Hz, 220 Hz

LKEB72600-K

Shortens the motor deceleration time by causing the regenerative energy to be consumed through the resistor . Available at 10096 deceleration torque at 1096 ED. Thermal overload relay to protect resistor overheating is built in.

Separately installed

Shortens the motor deceleration time by causing the regenerative energy to be consumed through the resistor. Available at 10096 deceleration torque at 396 ED for resistor unit only.

Separately installed

Name

Braking Resistor Unit

X

L_J L-J L -J

Braking Resistor

0)

ERF150WJ ;-; ;-1

Separately installed

* When using VS operator connected with + 12 V power supply for frequency setting (control circuit terminal 10), set constant no-22 to 1 .25 . The frequency reference voltage becomes 10096 of 8.0 V output frequency . T The types of frequency indicators are to be shown in the box after the model name and the number . Frequency Meter (max. scale)

Model ( in-,)

CodE, No. ( in, - )

60/ 120Hz, 75Hz

1

01

90/ 180Hz, 150Hz

2

02

220Hz

3

03

Page 72

1 . VS-606PO3 INVERTER MAIN UNIT (Contld) Name Remote Interface for Digital Operator Digital Operator

Installing Position

Model ;Code No.)

Function

JVOP-112 '73606-V 1120)

For remote operation of digital operator `type JVOP-116), used in combination with remote interface (RS-232C interface).

JVOP-114 (73606-V 1140)

Performs operation sequence, all function selections and constant setting. Also displays frequency setting, output frequency, output current and fault. However, it cannot be used remote operation.

Inverter front cover .

Performs multifunction aialog input. Analog input level : 0-10 V (input impedance : apDrox . 20 k Q ) Analog signal function can be selected by setting constant No.35 . (No.35 set value] 1 : Auxiliary frequency reference 2 : Frequency reference gain 3 : Frequency reference bias 4 : Output voltage bias

Inverter front Cover.

Has the same functions as type JVOP-114 and used for remote operation m combination with remote interface.

Separately installed .

Analog Input Module ;

JVOP-115 (73606-V 1150)

Digital Operator *

JVOP-116 (73606-V 1160)

Cannot be used for water and dust tight type (NEMA4). Refer to page 119.

Inverter front cover .

Page 73

1 . VS-606PO3 INVERTER MAIN UNIT (Cont'd) 1 .10.2 Peripheral Units Name

Model (Code No.)

Frequency Meter

DCF-6A

Frequency Setter Frequency Meter Adjusting Potentiometer Frequency Setting Knob

Provided with VS operator as standard. Available as separate components for remote control from several locations. Install at control circuit terminal for the calibration of frequency meter or ammeter and frequency reference.

Potentiometer

AC Reactor

Function

UZBA-~~;

Used for power supply coordination when power supply capacity exceeds 600 kVA, or for improvement of inverter input power factor .

Radio noise Protective Filter

LNFB~=; (Single-phase) LNFD ~-A (Three-phase)

Use a radio nose filter to eliminate radio wave interference . It is provided at input terminals of the inverter main circuit.

VS System Module

JGSM-1~

Enables optimum system configuration by combining -quired VS system modules according to automatic control system. .

Molded-case Circuit Breaker (MCCB)

NF- L-1

Installation of MCCB at power supply will protect the inverter connection .

Magnetic Contactor (MC)

H 1-r E `-'

MC is required on inverters using the dynamic braking function .

Surge Suppressor

DCR2- L _;

Absorbs surge currents by opening and closing of magnetic contactors and control relays . Must: be installed on magnetic contactors or control relays near the inverter.

Output Voltmeter

SCF-12NH

Voltmeter for PWM inverter .

Isolator

DGP~=;

Isolates the inverter input and output signals to reduce induced noise.

Note : Contact your YASKAWA representative for further information.

Page 74

MEMO

Page 75

2 . . DIGITAL OPERATOR (JVOP-1 14) The digital operator (JVOP-114), mounted directly on the inverter, is a VS-606PC3 exclusive use operation panel which can perform operation, change the control constants and monitor operation status.

2 .1 DIGITAL OPERATOR MOUNTING/REMOVING

The digital operator can be mounted and removed in the following procedures. It cannot be mounted or removed during current conduction . Be sure to turn off the inverter power supply and mount/remove it after the charge lamp is extinguished. Unless otherwise, it may cause malfunction . How to mount operator Insert the operator in the direction of the arrow mark until it goes to the end . OPERATOR

Page 76

2. DIGITAL OPERATOR (JVOP-114) (Cont*d) n~w to re move operator

(1) Remove the terminal cover (enclosed wallmounted type) or the front cover (water and dust tight type) . Refer to Par. 1 .5 .1 . (2) Lower the lever in the direction of 0 and insert the minus driver in section A. (For water and dust tight type, it is not necessary to push down on the lever.) Then lift the operator in the direction of (2) to remove it . OPERATOR

Cx

C

CIO

0

Page 77

2. DIGITAL OPERATOR (JV'OP-1 14) (Confd) 2.2 DESCRIPTION OF DIGITAL OPERATOR DISPLAY AND OPERATING SECTIONS i

Mode Display LED -------------Red lamp lights when controlled by external terminal commands .

i

SEQ: When RUN/STOP signal is through terminals . REF : When frequency ref . is through terminals ® and 09 .

rmi

Both SEQ and REF lamps go OFF when LOCAL mode is selected .

DRIVE

FV1'D

PRGM

Red lamp lights at FWD run . Red lamp lights at REV run. Red lamp lights in DRIVE mode and lights off in PRGM mode.

i --------------------------J

-- Run Command Key --------------,

Run command key to operate by digital operator Effective only in drive mode

Mode is switched alternately whether inverter is operated by run command and frequency reference (LOCAL) or by setting of the 1st/2nd digits of control constant No 1 .

i v

II i

Selects FWD or REV run . Effective only in DRIVE mode

I *Red lamp lights by depressing v

L RUN

*Red lamp lights by depressing STOP v

-66-

~~

"~rncirn~w

REV' r-REMOTE-

I.a

; Ir,

Page 78

2. DIGITAL OPERATOR (JVOP-114) (Cont'd)

Display Displays set value of each function or monitoring values such as frequency and output current . (5 digits) Mode Selection Key Depressing this key changes mode. (DRIVE or PRGM) Display Selection Key Depressing this key changes the display . See next page for explanation . Read/Write Key Depressing this key recalls and displays indicated data from memory . Depressing the second time enters displayed data into memory. Numeral Change Key Changes, numeral such as set values and constant signals . Increase V: Decrease Digit Selection Key Selects numerical digits . This key resets operation at faults

INV. OUTPUT FREQUENCY T P KEY

,

K

STOP KEY

FREQUENCY SET ~ltPiu i sro~ l_nMh

LIGHT o

.. BLINK

LIGHT OFF

* RUN or STOP lamp charges in accordance with the operations. -67-

Page 79

2. DIGITAL OPERATOR (JVIOP-114) (Cont'd) 2 .3 FUNCTION/CONSTANT SETTING 2.3 .1 DRIVE Mode and PRGM (Program) Mode

Selection of DRIVE mode or PRGM mode can be performed by using the

DRIVE key when the inverter is stopped . When function selection or a change of set value is required, switch to the PRGM mode.

DRIVE mode

Operation is enabled. - When stopped, LOCAL and REMOTE modes can be switched with each other by depressing L0';AE key. - An operation can be performed by R U N or keys. RE - Frequency reference value can be changed during running. STOP

PRGM mode

Program (function selection, constant setting) can be changed . Operation is not enabled. Display Contents of DRIVE Mode and PRGM Mode - Display contents of the digital operator differ according to selected mode (I'RGM/DRIVE) . The constant group to be displayed is changed each time display selection key is depressed. L ED:S :P

If a fault occurs, the contents are displayed. Additionally, since the contents of the latest fault are stored, maintenance, inspection or troubleshooting can be performed quickly by checking the contents by the digital operator.

Page 80

2 . D fGITAI OPERATOR (JVIC)P-114) (Confd) POWER ON DRIVE MODE MODE SWITCHABLE ONLY WHEN STOPPING I&M DRIVE i i

No. L_JL_J display/setting

Frequency reference value display/setting i

Output frequency monitor display Output current monitor display

* Refer to Par. 2.8 "FUNCTION/ CONSTANT LIST" .

If a fault occurs, the contents are displayed .

i v

-~

Fault reset

'

RESET

I i

1 r--ir-n

*No . L_JL_J reading i