Summary

What is in it

Yaskawa's instruction manual for the VS-606PC3 ultra-compact all-digital low-noise inverter in 230 V three-phase, 240 V single-phase and 460 V three-phase series (model CIMR-PCU). The first section covers receiving, installation, dimensions, wiring, test run, maintenance, fault display and troubleshooting, specifications and options. The second covers the JVOP-114 digital operator, setting and initializing constants, monitoring, the full function/constant list and protective functions.

Its parts

  1. VS-606PC3 Inverter Main Unit
  2. Digital Operator (JVOP-114)

From the manual

Key facts from this manual

Each line names its page in the PDF.

A Yaskawa instruction manual for the Varispeed-606PC3 (VS-606PC3) ultra-compact low-noise inverter, which covers the 230V three-phase, 240V single-phase and 460V three-phase series (CIMR-PCU2, CIMR-PCUB and CIMR-PCU4), including the 21P5 model this page is filed under. It explains receiving, wiring, test runs, the JVOP-114 digital operator and its constants, fault and alarm displays, troubleshooting, specifications and optional units.

Read for this summary: pages 1 to 11, 13 to 17, 57 to 66 and 71 to 73 of 157.

Device
Ultra-compact, all-digital, low-noise inverter (VS-606PC3 series) p. 13
Input power
21P5 is in the 230 V three-phase class: 3-phase 200 to 230 V, 50/60 Hz p. 65
Control method
Sine wave PWM, frequency control range 0.1 to 400 Hz p. 65
Speed reference
0 to 10 VDC or 4 to 20 mA analog signal p. 65
Accel/decel time
0.1 to 600 sec, accel and decel set independently p. 65
Control inputs
Forward and reverse run by separate commands, fault reset, and 3 multifunction contact inputs (such as external fault, jog, external baseblock, speed search) p. 66
Outputs
Two selectable multifunction outputs (48 VDC, 50 mA or less), one NO/NC contact (250 VAC 1 A, 30 VDC 1 A), analog 0 to 10 VDC monitor p. 66
Fault codes
Overcurrent, GF ground fault, OV overvoltage, UV undervoltage, OH cooling fin overheat, OL1 motor overload, OL2 inverter overload, OL3 overtorque, EF3 to EF5 external fault, CPF control function fault p. 58, 59
Bus voltage limits
230 V class: stops above 410 VDC on the main circuit; undervoltage below 210 VDC p. 65
Power loss ride-through
21P5: automatic restart after a momentary power loss of up to 2 seconds, when enabled with constant No. 46 p. 66
Enclosures
NEMA 1 enclosed wall-mounted or NEMA 4 water and dust tight; with digital operator or with indicating cover p. 13
Ambient temperature
+14 to 104 F (-10 to +40 C), not frozen; storage -4 to 140 F p. 66
Digital operator
JVOP-114, mounted on the inverter front cover, sets all functions and constants and shows frequency, current and faults p. 72
Optional units
JVOP-95 and JVOP-96 VS operators, JVOP-112 remote interface (RS-232C), JVOP-115 analog input module, JVOP-116 remote digital operator, ERF150WJ braking resistor p. 71, 72

What this manual walks you through

  • Receiving the inverter and reading the nameplate and type designation p. 16, 17
  • Finding the cause of a fault shown on the display p. 57, 58, 59, 60
  • Alarm displays that clear on their own p. 61, 62
  • Troubleshooting a motor that will not turn, runs backward or runs at the wrong speed p. 63, 64
  • Electrical, control and environmental specifications p. 65, 66
  • Choosing optional units and peripheral devices p. 71, 72, 73
  • Setting function constants with the digital operator p. 6, 7

Good to know

  • Capacitors stay charged for five minutes after input power is opened. p. 10
  • Do not run withstand voltage tests on any part of the unit. p. 11
  • Separate motor overcurrent, overload and overheating protection is required under the Canadian Electrical Code and NEC. p. 9
  • Use 75 C copper wire only. p. 9
  • The JVOP-114 digital operator cannot be used for remote operation. p. 72

Questions this manual answers

How do I reset a fault on the VS-606PC3?

Turn on the fault reset input or press the RESET key on the digital operator, or switch the power off and on again, after finding the cause. p. 57

What does OV mean on a Varispeed-606PC3?

Main circuit overvoltage: on 230 V class units the DC voltage reached 410 V or more. The manual points to too short a decel time or a minus load, and suggests a longer decel time or an optional braking resistor. p. 58

What should I do about a CPF fault?

CPF is a control function fault. Turn the power off and on again; if the fault remains, the manual says to replace the inverter. p. 59, 60

Which digital operator fits the VS-606PC3?

The JVOP-114 mounts on the inverter front cover. For remote operation the JVOP-116 is used with the JVOP-112 remote interface. p. 72

Why does my motor not rotate?

Check that supply voltage reaches L1, L2, L3 (charge lamp on), that a FWD or REV run command and a frequency setting are present, and that the load is not locked. p. 63

The whole text · 16 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 157151-157

The file

Revision and size

RevisionManual No. TOE-S606-31C
PublisherYaskawa
Pages157
PDF8.3 MB
TextText from the PDF itself.

The first pages · 3 of 157

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 157
Page 2
Page 2of 157
Page 3
Page 3of 157