The text of a manual · part 3 of 16
Varispeed-606PC3 Instruction Manual, pages 21 to 30
Pages 21 to 30 of 157
The original document is the PDF (8.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the EMS PC3-21P5
Page 21
t . VS-606PC3 INVERTER MAIN UNIT (Cont'd) VS-606PC3 Model CIMR-PCU
W
Wi
H
H1
H2
D d n-e
20P 1 20P2
4.45 (113)
366 (93)
6.77 (172)
5.43 (138)
0 .43 (11)
4.07 (103.5)
0.20 (5)
2-0 .91 (2-23)
20P4 20P7
5.83 (148)
5.04 (128)
6.77 (172)
5.43 (138)
0.43 (11)
5.59 (142)
020
3-0 .91 (3-23)
21P5 22P2
5.83 (148)
4.96 (126)
8.94 (227)
7.32 (186)
0.47 (12)
6.83 (173.5)
022 (55)
23P7
7.87 (200)
6.89 (175)
9.06 (230)
BOP 1 BOP2 BON
728 0 .50 7.62 (185) (12.8) (193.5)
023 (5.8)
1-0 .91 2-1 .13 ( 1-23l \ 2-28.6/
5 .83 (148)
5.04 (128)
6 .77 (172)
5.43 (138)
0.43 (11)
5.59 (142)
020 (5)
3-0 .91 (3-23)
BOP7 B1P5
5.83 (148)
4.96 (126)
8.94 (227)
7 .32 (186)
0.47 (12)
6.83 (173.5)
022 (5.5)
82P2
7.87 (200)
6.89 (175)
9.06 (230)
7.28 (185)
(12.8) (193.5)
0.50
7.62
0.23 (5.8)
1-0 .91 2_1 .13 1-23l (2-28 .6 1
40P2 40P4
5.83 (148)
4.96 (126)
8.94 (227)
7 .32 (186)
0.47 (12)
4.86 (123.5)
022
40P7 41P5
5.83 (148)
4.96 (126)
8.94 (227)
7.32 (186)
0.47 (12)
6.83 (173.5)
022 (5.5)
42P2 43P7
7.87 (200)
6.89 (175)
9.06 (230)
7.28 0.50 7.62 (185) (12 .8) (193.5)
0.23 (5.8)
(5)
(5.5)
t-0.91 2-1 .13 1-23l (2-28.6' tuz
Page 22
1 . VS-606PC3 INVERTER MAIN UNIT (Cont'd) 1 .4 INSTALLATION 1 .4 .1 Transportation
Handle with care so as not to damage the inverter during transportation. Do not pick-up by the front cover or the unit cover (plastic portion). Use the die-cast portion . Do not drop the inverter.
1 .4.2 Mounting Space Install the VS-606PC3 vertically and allow sufficient space for effective cooling as shown in Fig. 1 .1 . 1 .18 in (30 mm) OR MORE
1 .18 in (30 mm) OR MORE 3 .94 m (100 mm) OR MORE
3 94 m (100 mm) OR MORE t-
(a)
Front View
AIR
AIR
(b) Side View
Notes 1 . The space required at top/bottom and both sides are common in enclosed wallmounted type and water and dust tight type . The inverter shown above is enclosed wall-mounted type . 2. For external dimensions, refer to Par. 1 .3 "Dimensions in inches (mm)" on page 6. Fig. l .I
Mounting Space:
- 10 -
Page 23
t . VS-606PO3 INVERTER MAIN UNIT (Confd) 1 .4 .3 Location
Location of the equipment is important to achieve proper performance and normall operating life. The VS606PC3 units should be installed in areas where the following conditions exist . Ambient temperature : +14 to 104 ° F, -10 to +40 °C . Protected from rain or moisture. (For enclosed wallmounted type) Protected from oil sprays, splashes . Protected from direct sunlight. (Avoid using outdoors .) Protected from corrosive gases or liquids. Free from airborne dust or metallic particles. (For enclosed wall-mounted type) Free from salt spray. Free from vibration. Free from magnetic noise . (Example : welding machines, power devices, etc.) Protected from high humidity . Free from combustibles .
cc L_
Page 24
t . VS-606PO3 INVERTER MAIN UNIT (Cont'd) CAUTION Enclosed wall-mounted type (NEMA1)
When mounting units in an enclosure, remove the top, bottom and terminal covers, and install a cooling fan or some other means to cool the air entering into the inverter below 113 ° F (45 °C) . Water and dust tight type (NEMA4)
Never submerse this model in water. The models of a forced-air-cooled type are provided with a cooling fan in the die-cast case. Protect the cooling fan from moisture . Excessive water splash may reduce the inverter operating life . If water splashes on the cooling fan section, keep the cooling fan operating for approx. 30 minutes in order to dry it. (By conducting current to the inverter unit, the cooling fan rotates .) For the cable lead-in section (at the bottom cover), use a cable gland of a waterproof type . (Products described in pages 14 and 15 are available as options.) Cable lead-in holes are not provided in the bottom cover . According to your application, drill holes in the bottom cover . Refer to pages 8 and 9. After completion of wiring, mount the front cover and bottom cover with care . (Pay attention so as not to damage the gasket.) Since the inverter unit cover is sealed with the die-cast case, never remove it . The front cover mounting screws and bottom cover mounting screws are of stainless . Do not use any other screws than those attached . (In particular, screws of different length may cause damage .) When silicon rubber cement applied to the contacting section of the front cover and bottom cover for reinforcement of waterproof performance, use silicon rubber cement with less gas generated when hardening . (Recommended : KE-3494 made by SHIN-ETSU CHEMICAL CO., LTD.) - 1 2-
Page 25
1 . VS-606PO3 INVERTER MAIN UNIT (Cont'd) 1 .4.4 Cable Gland When a cable gland is used for water and dust tight type (NEMA4) models, pay attention to the following items . - Use multi-core cable for cable gland. (If more than two cables are inserted into one cable gland, a gap is created and may cause leakage.) - Seal the cable gland with a gasket wichout fail. (A gasket is attached to the recommended cable gland .)
Cable Gland Mounting Hole (Not Drilled in Bottom Cover) Dimensions in inches (mm) VS-606PC3 Model CIMR-PCU 20P 1 20P2 20P4 20P7 21P5 22P2 23P7 BOP 1 BOP2 BOP4 BOP? B 1 P5 B2P2 40P2 ' 43P7 oty-Dia j 2-0 .91 (2-23) 3-0 .91 (3-23) 1-0.91 2-1 13 1-23 (2-286 3-0 .91 (3-23) 1-091 2-1 13 1-23 (2-286 1-091 2-1 13 1-23 (2-286
Page 26
1 . VS-606PO3 INVERTER MAIN UNIT (Cont'd) Recommended cable gland
For cable gland for water and dust tight type (NEMA4) models, refer to the following YASKAWA code No. and quantity when you place an order. VS-606PC3 Model CIMR-PCU ;-----20P 1 20P2 20P4 20P7 21P5 22P2 23P7
Cable Gland YASKAWA Code No.
Qty
WSZT31002-A
2
WSZ T31002-A
3
WSZT31002-A
1
WSZT31002-B
2
WSZT31002-A
3
WSZT31002-A
1
WSZT31002-B
2
WSZT31002-A
1
WSZT31002-B
2
BOP 1 BOP2 BOP4 BOP7 B 1 P5 B2P2 40P2 40P4 40P9 41P5 42P2 43P7 Notes 1 . Lock nut, gasket and the like requirec for one-hole wiring with one cable gland are provided . 2. The quantity shown in the above table is the number of cable glands required for one inverter unit.
Page 27
1 . VS-606PC3 INVERTER MAIN UN-1T (Cont'd)
bftblb,
Dimensions in inches 'mm;
qqq~FA
B
SW 1
Cmax
D
E:
F
H
SW2
G
WSZT31002-A 1 16 1.29 .5; ;Size PG 16)
057 ',14.5)
1 .06 (27,
142 1,36)
073 1,18 5,
024 ; E3)
008 ((2',
026 (6.51
1.18 130)
130 ;33 ;
WSZT31002-B 140 ;Size PG 21, (35.5)
073 (18.5)
130 ; 33,`
157 ;40)
089 (225)
024 ;61
008 '2',
0.30 (75)
142 (36)
154 (39)
C
Q
CD
LCCKNUT
Specifications Cable Gland
Applicable cable size
'Tightening torque
WSZT31002-A
0 39 DIA to 0 55 DIA (10 DIA to 14 DIN 0 .51 DIA to 0 7 DIA` (13 DIA to 18 DIA)
5 to 9 (N-m)
WSZT31002-B
7.5 to 9 (N-m)
Page 28
1 . VS-606PO3 INVERTER MAIN UNIT (Cont'd) 1 .5 WIRING Connect main circuit and control circuit wiring securely as described in the following.
Use UL Listed and CSA Certified closed-loop (ring) connectors sized for the wire gauge involved. The connectors are to be installed using the correct crimp tool specified by the connector manufacturer.
1 .5 .1 Cover Mounting/Removing and Terminal Position Enclosed wall-mounted type (NEMA1) Terminal cover mounting/removing For removing, press the cover in the direction of D (on both sides) and, at the same time, lift in the direction of 0. For mounting, reverse the method.
TIMME o
TERMINAL
' ~\ 0 rr °
Page 29
1 . V$-606PC3 INVERTER MAIN UNIT (Cont'd) Water and dust tight type (NEMA4) Front cover mounting/removing Remove the four mounting bolts and take off the cover in the direction of U . For mounting, reverse the method .
Page 30
1 . VS-606PC3 INVERTER MAIN UNIT (Cont'd) Bottom cover mounting/removing Remove the four mounting bolts when installing cable glands, etc. Install wiring after inserting cables through the cable glands and securing them to the bottom cover .