Page 91
Terminal CPX-P Technical data – Interlinking block with additional power supply for outputs Ordering data Designation Interlinking block with additional power supply for outputs 7/8" connection, metal interlinking block
Part No.
Type
550210
CPX-M-GE-EV-Z-7/8-5POL
5-pin
–
5-pin
For ATEX environment 8022158
5-pin
543107
NECU-G78G5-C2
Angled socket, 5-pin – open cable end, 5-pin
2m
573855
NEBU-G78W5-K-2-N-LE5
Screws for mounting the bus node/connection block on an interlinking block
Bus node/plastic connection 550219 block Bus node/metal connection block 550216
7/8" connection sockets Power supply socket
CPX-M-GE-EV-Z-7/8-5POL-VL
Mounting accessories
2018/04 – Subject to change
CPX-M-M3x22-4x CPX-M-M3x22-S-4x
è Internet: www.festo.com/catalogue/...
91
Page 92
Terminal CPX-P Technical data – Pneumatic interface VMPA‐FB Function The pneumatic interface VMPA‐FB establishes the electromechanical connection between the CPX-P ter minal and the valve terminal MPA-S. The signals from the bus node are for warded to the control electronics in the electrical modules of the valve ter minal MPA-S via the integrated CPX-P bus. The bus signal for activation of the solenoid coils is converted in the electronics module for max. 8 coils. From a technical point of view, the individual MPA pneumatic modules each represent a separate electric module with digital outputs. Valves, which are galvanically isolated, can be supplied with power via the interlinking block CPX-GE-EV-V.
Applications Interface to the valve terminal MPA-S Max. 128 solenoid coils Features of the electronics module of the valve terminal MPA-S can be parameterised, for example status of the solenoid coils in the event of fieldbus communication being interrupted (fail-safe), individual channel diagnostics can be acti vated, condition monitoring can be activated individually for each valve The pneumatic interface receives the voltage for the electronics and the supply voltage for the valves from the left-hand interlinking block and feeds them through to the electronics modules of the valve terminal MPA-S Electronics modules of the valve terminal MPA-S: – Undervoltage of valves – Short circuit of valves – Open load of valves – Counter preset reached in condition monitoring
General technical data Type Number of solenoid coils Pilot air supply Pilot air port 12/14 Pneumatic connection 1 Operating pressure Pilot pressure Nominal operating voltage Protection class to EN 60529 Ambient temperature Materials Product weight
92
VMPA-FB-EPL-G
[bar] [bar] [V DC] [°C] Cover Housing [g]
è Internet: www.festo.com/catalogue/...
128 Internal – G¼ 3…8 3…8 24 IP65 –5 … +50 PA Die-cast aluminium Approx. 320
VMPA-FB-EPL-E External M7 G¼ –0.9 … 10 3…8
Subject to change – 2018/04
Page 93
Terminal CPX-P Technical data – Pneumatic interface VMPA‐FB Overview – Pneumatic interface VMPA-FB 4 3
2 1
5 1 2 3 4
Pneumatic interface VMPA‐FB Inscription label Flat plate silencer Exhaust plate for ducted exhaust air 5 Fittings
Ordering data Designation
Part No.
Type
Ducted exhaust air, internal pilot air
552286
VMPA-FB-EPLM-G
Ducted exhaust air, external pilot air
552285
VMPA-FB-EPLM-E
Flat plate silencer, internal pilot air
552288
VMPA-FB-EPLM-GU
Flat plate silencer, external pilot air
552287
VMPA-FB-EPLM-EU
For ducted exhaust air, with 10 mm push-in connector
533375
VMPA-AP
For ducted exhaust air, with QS-y connector
541629
VMPA-AP-y
Flat plate silencer
533374
VMPA-APU
Pneumatic interface
Exhaust plate
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
93
Page 94
Terminal CPX-P Technical data Download CAD data è www.festo.com
Dimensions – Metal interlinking block With bus nodes and connection blocks
1 Left-hand end plate 2 Bus node 3 Connection block CPX-AB-8-M8-3POL 4 Connection block CPX-AB-4-M12X2-5POL
5 Connection block CPX-AB-8-KL-4POL 6 Connection block CPX-AB-1-SUB-BU-25POL 7 Connection block CPXP-AB-4-2XKL-8POL
8 Connection block CPX-P-AB-4XM12-4POL 9 Right-hand end plate aJ Mounting bracket for wall mounting aA Hole for self-tapping screw M2.5
Type
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
CPX-P
124.9
124.6
118.9
108.1
78
66.3
65
19.3
20
7.9
6.6
4.4
Type
H1
H2
H3
H4
H5
H6
H7
CPX-P
116
109
106.2
69.2
55.1
46.6
10.8
Type
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
CPX-P nx50.1
150.3
125.3
50.1
30.4
6.8
4.5
4
1.5
1
94
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 95
Terminal CPX-P Technical data Download CAD data è www.festo.com
Dimensions With bus nodes and valve terminal MPA-S
1 2 3 4 5
6 7 8 9 aJ
Solenoid valve MPA1 Solenoid valve MPA2 Manual override Supply/exhaust ports Working ports aA aB aC aD
H-rail H-rail mounting Mounting holes Pneumatic interface VMPA‐FB CPX-P module
Earthing screw Electrical supply plate Pressure sensor Proportional pressure regulator n m
Number of sub-bases in a grid of 4 MPA1 or 2 MPA2 valves Number of CPX-P modules
Type
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
CPX-P
131.4
107.3
78
66.3
65
33.5
23.5
19.3
18
11
6.6
4.4
7.5
20
Type
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
CPX-P
62
60.5
56
48
44.3
23.9
23.1
22.6
21.8
20.3
10.8
9.8
8.8
8.7
46.6
Type
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
CPX-P m x 50.1 n x 42
51.2
42
32
30.4
34.7
25.7
16.7
30
21
16
Type
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22
L23
L24
CPX-P
12
20
18
10.5
7.7
9
23.7
13.5
14.5
25.9
1.5
1
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
95
Page 96
Terminal CPX-P Accessories Ordering data – Accessories Designation
Part No.
Type
Plug connectors Sub-D socket, 9-pin
For DeviceNet
532219
FBS-SUB-9-BU-2x5POL-B
Sub-D plug, 9-pin
For PROFIBUS DP
532216
FBS-SUB-9-GS-DP-B
Sub-D plug, angled
For PROFIBUS DP
533780
FBS-SUB-9-WS-PB-K
B-coded
For PROFIBUS-DP
533118
FBA-2-M12-5POL-RK
Micro Style
For DeviceNet
525632
FBA-2-M12-5POL
18324 1067905
FBSD-GD-9-5POL NECU-M-B12G5-C2-PB
Solderable
For FBA-2-M12-5POL For FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP For NEDY-L2R1-V1-M8G3-N-M8G4
18696
SEA-GS-M8
Screw-in
For NEDY-L2R1-V1-M8G3-N-M8G4
192009
SEA-3GS-M8-S
Spring-loaded terminal Screw terminal
For cable 4 … 8 mm
575719
NECU-M-S-A12G4-IS1)
D-coded For Ethernet For cable 2.5 … 2.9 mm
543109 570955 192008 570956 18779 570953 18666 570954 18778 525928
NECU-M-S-D12G4-C2-ET NECU-S-M12G4-P1-Q6-IS1) SEA-4GS-7-2,5 NECU-S-M12G4-D-IS1) SEA-GS-11-DUO NECU-S-M12G4-P1-IS1) SEA-GS-7 NECU-S-M12G4-P2-IS1) SEA-GS-9 SEA-GS-HAR-4POL
192010 175487 175380 1066354
SEA-5GS-11-DUO SEA-M12-5GS-PG7 FBS-M12-5GS-PG9 NECU-M-S-B12G5-C2-PB
571052
CPX-AB-1-7/8-DN
For PROFIBUS-DP
541519
CPX-AB-2-M12-RK-DP
Open Style bus connection for 5-pin terminal strip
For DeviceNet
525634
FBA-1-SL-5POL
5-pin terminal strip
For Open Style connection
525635
FBSD-KL-2x5POL
Bus connection, Sub-D plug, 9-pin adapter to 5-pin M12 Sub-D socket, 9-pin plug/socket M12 socket, 5-pin Screw terminal Screw terminal Plug M8, 3 pin
Plug M12, 4 pin
For cable 2x3 mm or 2x5 mm For 2x cable 3 … 5 mm For cable 4 … 6 mm For cable 6 … 8 mm Insulation displace ment connector Screw terminal
Plug, M12, 5-pin
Connection block, Sub-D socket, 9-pin adapter to 5-pin 7/8" plug Connection block, Sub-D plug, 9-pin adapter to M12 plug/ socket
1)
96
Connecting cross-section 0.25 … 0.5 mm2 For 2x cable 2.5 … 5 mm For cable 4 … 6 mm For FBA-2-M12-5POL For FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP – For DeviceNet
B-coded
Component preferred for operation in intrinsically safe circuits.
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 97
Terminal CPX-P Accessories Ordering data – Accessories Designation
Part No.
Type
534494
FBS-RJ45-8-GS
Sub-D plug, 25-pin
565712 565711 565710 565709 527522
NECU-L3G8-C1 NECU-L3G8-C1-IS1) NECU-L3G8-C2 NECU-L3G8-C2-IS1) SD-SUB-D-ST25
Modular system for all types of sensor/actuator distributor
–
NEDY-… è Internet: nedy
Modular system for connecting cables
–
NEBU-… è Internet: nebu
8005312 8005311 562248 8005310 541346 541347 541348 541349 529044 530901
NEDY-L2R1-V1-M8G3-N-M8G4 NEDY-L2R1-V1-M8G3-N-M12G4 NEDU-M12D4-M12T4-IS1) NEDY-L2R1-V1-M12G5-N-M12G4 NEBU-M8G3-K-0.5-M8G3 NEBU-M8G3-K-1-M8G3 NEBU-M8G3-K-2.5-M8G3 NEBU-M8G3-K-5-M8G3 KV-M12-M12-1,5 KV-M12-M12-3,5
Plug connectors RJ45 plug
Socket, 8-pin
Spring-loaded terminal Screw terminal
Black Gentian blue Black Gentian blue
Connecting cables
1)
Push-in T-connector
1x plug, M8, 4-pin 1x plug, M12, 4-pin
Connecting cable M8-M8
3-pin
Connecting cable M12-M12
5-pin
2x socket, M8, 3-pin 2x socket, M8, 3-pin 2x socket, M12, 4-pin 2x socket, M12, 5-pin Straight plug/ 0.5 m straight socket 1.0 m 2.5 m 5.0 m Straight plug/ 1.5 m straight socket 3.5 m
Component preferred for operation in intrinsically safe circuits.
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
97
Page 98
Terminal CPX-P Accessories Ordering data – Accessories Designation
Part No.
Type
7/8" connection, 5-pin
543107
NECU-G78G5-C2
7/8" power supply socket, 5-pin, angled socket/open cable end, 5-pin
2m
573855
NEBU-G78W5-K-2-N-LE5
Mounting rail for attaching the hood
1,000 mm
572256
CAFC-X1-S
572257
CAFC-X1-BE
Plug connectors and accessories – Power supply Power supply socket, straight
Hood
Mounting kit for CPX hood
Hood section for CPX-P terminal including mounting attachments for connecting several hood sections in series
200 mm
572258
CAFC-X1-GAL-200
300 mm
572259
CAFC-X1-GAL-300
Screws for mounting the bus node/connection block on an interlinking block
Bus node/plastic connection block Bus node/metal connection block 12 piece
550219
CPX-M-M3x22-4x
550216
CPX-M-M3x22-S-4x
550222
CPX-M-M2,5X8-12X
Version for metal interlinking plates
550217
CPX-M-BG-RW-2x
Mounting for H-rail
526032
CPX-CPA-BG-NRH
Memory card for PROFINET bus node (CPX-FB33, CPX-M-FB34, CPX-M-FB35), 2MB
568647
CPX-SK-2
Terminating resistor, M12, B-coded for PROFIBUS
1072128
CACR-S-B12G5-220-PB
Adapter from 5-pin M12 to mini USB socket and controller software
547432
NEFC-M12G5-0.3-U1G5
Screws
Screws for attaching an inscription label holder to the bus node (CPX-FB33) Mounting Attachment for wall mounting (for long valve terminals, 2 mounting brackets and 4 screws)
Function blocks
98
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 99
Terminal CPX-P Accessories Ordering data – Accessories Designation
Part No.
Type
538219
AK-8KL
Fittings kit for hood AK-8KL
538220
VG-K-M9
Screening plate for connection block CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R
526184
CPX-AB-S-4-M12
Inspection cover, transparent
533334
AK-SUB-9/15-B
Transparent cover for DIL switch and memory card
548757
CPX-AK-P
Cover for RJ45 connection
534496
AK-Rj45
Covers and attachments Hood for CPX-AB-8-KL-4POL (IP65/67)
8 cable through-feeds M9 1 cable through-feed for multi-pin plug
Cover cap for sealing unused connections (10 pieces)
For M8 connections
177672
ISK-M8
For M12 connections
165592
ISK-M12
Coding element (96 pieces of each)
For NECU-L3G8
565713
CPX-P-KDS-AB-2XKL
Insulating plate for safe separation of intrinsically safe and non-intrinsically safe areas of the CPX terminal
565708
CPX-P-AB-IP
Inscription labels 6x10 mm, 64 pieces, in frames
18576
IBS-6x10
Inscription label holder for connection block
536593
CPX-ST-1
German
537927
P.SW-FST4-CD-DE
English
537928
P.SW-FST4-CD-EN
Inscription labels
Software Programming software
1)
Component preferred for operation in intrinsically safe circuits.
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
99