Page 11

Contents and general instructions

Important user instructions Danger categories This manual contains instructions on the possible dangers which may occur if the product is not used correctly. These instructions are marked (Warning, Caution, etc.), printed on a shaded background and marked additionally with a gram. A distinction is made between the following danger warnings:

Warning This means that failure to observe this instruction may result in serious personal injury or damage to property.

Caution This means that failure to observe this instruction may result in personal injury or damage to property.

Please note This means that failure to observe this instruction may result in damage to property.

The following pictogram marks passages in the text which describe activities with electrostatically sensitive nents. Electrostatically sensitive components may be damaged if they are not handled correctly.

Festo P.BE−CPX−SYS−EN en 0503b

IX

Page 12

Contents and general instructions

Marking special information The following pictograms mark passages in the text ing special information. Pictograms Information: Recommendations, tips and references to other sources of information.

Accessories: Information on necessary or sensible accessories for the Festo product.

Environment: Information on environment−friendly use of Festo products.

Text markings ·

The bullet indicates activities which may be carried out in any order.

1. Figures denote activities which must be carried out in the numerical order specified.

X

Hyphens indicate general activities.

Festo P.BE−CPX−SYS−EN en 0503b

Page 13

Contents and general instructions

Notes on the use of this manual This manual contains general basic information on the method of operation, on fitting, installing and commissioning CPX terminals. Special information on commissioning, parameterising and diagnosing a CPX terminal with the field bus node you are using can be found in the appropriate manual for the field bus node. Information on further CPX modules can be found in the ual for the relevant module. The following table provides an overview. Conventions The parameters and data of the CPX terminal are described in Appendix B.2. These appear in English on the handheld type CPX−MMI−1. [........]

In this description, the data and parameters displayed on the handheld in English are framed in the text in brackets, e.g. [Debounce time]. In the text, a fuller description pears next to it, Input debouncing time

Festo P.BE−CPX−SYS−EN en 0503b

[Debounce time]

XI

Page 14

Contents and general instructions

Type

Title

Description

Electronics manual

System manual"

Overview of structure, components and method of operation of CPX terminals Installation and commissioning instructions as well as basic principles of parameterisation

CPX field bus node"

Instructions on fitting, installing, ing and diagnosing the relevant field bus node

CPX I/O modules" type P.BE−CPX−EA−...

Notes on connection and instructions on fitting, installing and commissioning input and output modules of type CPX−..., the MPA pneumatic modules as well as of MPA, CPA and Midi/Maxi pneumatic interface

CPX analogue

Notes on connection and instructions on fitting, installing and commissioning CPX analogue I/O modules

CPX−CP interface" type P.BE−CPX−CP−..

Instructions on commissioning and diagnosing CPX terminals with the CP interface type CPX−CP−4−FB

Handheld" type P.BE−CPX−MMI−1−...

Instructions on commissioning and diagnosing CPX terminals with the handheld type CPX−MMI−1

CPX−FEC" type P.BE−CPX−FEC−...

Instructions on fitting, installing, ning and diagnos. the CPX Front−End Controller.

Software package

FST"

Programming in Statement List and Ladder Diagram for the FEC

Manual pneumatics

Valve terminals with type P.BE−MPA−...

Information on fitting, installing and sioning MPA pneumatics (type 32)

Valve terminals with type P.BE−CPA−...

Information on fitting, installing and sioning CPA pneumatics (type 12)

Valve terminals with Midi/Maxi pneumatics" type P.BE−MIDI/MAXI−03−...

Instructions on fitting, installing and sioning Midi/Maxi pneumatics (type 03)

XII

Manuals on the CPX terminal

Festo P.BE−CPX−SYS−EN en 0503b

Page 15

Contents and general instructions

Term/abbreviation

Meaning

CP

Compact Performance

CPX bus

Data bus via which the CPX modules communicate with each other and are supplied with the required operating voltage.

CPX modules

Common term for the various modules which can be incorporated in a

CPX terminal

Modular electric terminal type 50

DIL switch

Dual−in−line switches consist of several switch elements with which settings can be made.

Field bus node

Provide the connection to specific field buses. Transmit control signals to the connected modules and monitor their ability to function.

I

Digital input

Input module

CPX input module

I/O diagnostic interface

The I/O diagnostic interface is a bus−independent diagnostic interface at I/O level which permits access to internal data of the CPX terminal.

I/O modules

Common term for the CPX modules which provide digital inputs and outputs (CPX input modules and CPX output modules).

I/Os

Digital inputs and outputs

Manifold base

Lower part of the housing of a module or sub−base for linking the module electrically with the terminal.

O

Digital output

Output module

CPX output module

PLC/IPC

Programmable logic controller/industrial PC

Pneumatic interface

The pneumatic interface is the interface between the modular electric periphery and the pneumatics.

Status bits

Internal inputs which supply coded common diagnostic messages.

Sub−base

Replaceable upper part of module housing with connections

Product−specific terms and abbreviations

Festo P.BE−CPX−SYS−EN en 0503b

XIII

Page 16

Contents and general instructions

XIV

Festo P.BE−CPX−SYS−EN en 0503b