Page 1 of CPX terminal Electronics manual: System description, installing and commissioning CPX terminals

Manual · Festo

CPX terminal Electronics manual: System description, installing and commissioning CPX terminals

Manual221 pagesPDF 2.2 MB

System manual for the Festo CPX terminal: structure, fitting, installation, commissioning and diagnosis, with a short section on the CPX-CP interface.

What this file really is

The old site listed this file as a manual for the Festo CPX-CP-4-FB. This is the general CPX terminal system manual (P.BE-CPX-SYS-EN), not a manual for the CPX-CP-4-FB interface, which it mentions only briefly and refers to its own separate manual.

Download the PDF2.2 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The Festo electronics system manual for CPX terminals. It describes how the CPX terminal and its electric modules are built and powered, how to fit modules and mount the terminal on a hat rail or wall, how to connect the operating voltage and field bus, how to commission and parameterise it, and how to diagnose errors with LEDs, status bits and the I/O diagnostic interface. Appendices give technical specifications, cable lengths and the internal parameters and data.

Its parts

  1. Summary of components
  2. Fitting
  3. Installation
  4. Commissioning
  5. Diagnosis and error treatment

From the manual

Key facts from this manual

Each line names its page in the PDF.

A Festo electronics manual giving the system description and the fitting, installing and commissioning steps for modular CPX terminals, edition en 0503b. It is the general manual for the whole CPX terminal, not a manual for the CPX-CP interface module alone, and it refers to a separate CPX-CP interface manual for that module's details. It covers the module line-up, power supply, commissioning, fault numbers and diagnosis, and technical specifications.

Read for this summary: pages 1, 3, 8 to 9, 20 to 21, 28, 42, 87 to 88, 98 to 99, 110 to 117 and 135 to 137 of 221.

Device
Modular CPX terminal of electric and pneumatic modules for controlling pneumatic actuators and low-current electric devices p. 20
CPX−CP interface
Connects decentrally arranged CP valve terminals and CP I/O modules; maximum 128 external I/Os per interface p. 28
Electronics supply
24 V DC, protected against incorrect polarity, tolerance 18...30 V, max. 1.5 A without sensor supply, 4 Vpp ripple p. 136
Valve load tolerance
+10/-15 % with CPA pneumatics or the CPX−CP interface; ±10 % Midi/Maxi; ±25 % MPA p. 87
Pneumatic capacity
Midi/Maxi up to 26 valve coils; CPA up to 22; MPA up to 8 modules with up to 64 valve coils p. 28
Supply modules
System supply CPX−GE−EV−S, additional output supply CPX−GE−EV−Z, additional valve supply CPX−GE−EV−V p. 88
Supply fusing
External fuse on each supply: M18 plug 16 A; 7/8 plug 12 A p. 88
Operating temperature
-5 to +50 °C; storage and transport -20 to +70 °C p. 135
Protection class
Set by the weakest component: terminal connections IP20, M8 and M12 connections IP65 and IP67 p. 135
Diagnostics
Module LEDs, handheld in clear text, 8 status bits over the field bus, and an I/O diagnostic interface p. 111
CP faults
34 [CP module lost / fault]; also [CP configuration failure] and [Short circuit CP−Line] p. 115
Class 3 faults
Numbers 128 to 140: hardware, system or CBUS faults, many cleared only by replacing the module p. 117

What this manual walks you through

  • Structure of a CPX terminal and the modules it can hold p. 20, 21
  • Diagnosis by LED, handheld and field bus p. 110, 111
  • Looking up fault numbers and their treatment p. 112, 113, 114, 115, 116, 117
  • Technical specifications of the terminal p. 135, 136, 137

Good to know

  • The maximum permitted current per supply pin is 16 A. p. 136
  • Check the DIL switch settings before using or replacing a CPX terminal. p. 99
  • CPX modules and cables are for industrial use only. p. 8

Questions this manual answers

How many I/Os can one CPX-CP interface handle?

Up to 128 external I/Os per CPX−CP interface. p. 28

What supply voltage does a Festo CPX terminal need?

24 V DC for the electronics and sensors, with a tolerance of 18 to 30 V. p. 136

What does CPX fault 34 CP module lost mean?

An incorrect string assignment was found during operation, for example a failed CP module or a defective CP cable. p. 115

What does the SF LED flashing three times mean on a CPX terminal?

An error of class 3, the highest priority: a hardware or internal fault. p. 112

Why does a CPX terminal with a CP interface report module code incorrect (fault 16)?

The string assignment saved in the CPX−CP interface does not match the configuration saved in the field bus node or CPX-FEC. p. 114

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Designated use8
  2. Areas of application and approval by authorities9
  3. Target group10
  4. Service10
  5. Important user instructions11
  6. Notes on the use of this manual13
  7. Summary of components17
    1. 1.1 Structure of the CPX terminal20
    2. 1.2 Commissioning, diagnosis and operating functions43
  8. Fitting45
    1. 2.1 General instructions on fitting and dismantling48
    2. 2.2 Fitting the electric modules49
    3. 2.3 Fitting the CPX terminal62
  9. Installation75
    1. 3.1 General instructions on installation78
  10. Commissioning95
    1. 4.1 Commissioning procedure98
    2. 4.2 Preparing the CPX terminal for commissioning99
    3. 4.3 Start-up behaviour of the CPX terminal105
  11. Diagnosis and error treatment107
    1. 5.1 General instructions on diagnosis110
    2. 5.2 Diagnosis via status bits or the I/O diagnostic interface125
  12. Technical appendix133
    1. A.1 Technical specifications135
    2. A.2 Cable length and cross-sectional area138
  13. Parameters and data of the CPX terminal143
    1. B.1 Access to internal parameters and data146
    2. B.2 Description of the parameters and data147
  14. General information on parametrizing189
    1. C.1 Input debouncing time192
    2. C.2 Signal extension194
5 more lines, from page 197 on
  1. C.3 Influence of signal states197
    1. C.4 Diagnostic memory209
    2. C.5 Monitoring faults212
  2. Index215

From the PDF’s own bookmarks.

The whole text · 26 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Contents5-7
  3. Pages 8 to 108-10
  4. Pages 11 to 1611-16
  5. Summary of components, pages 17 to 2617-26
  6. Summary of components, pages 27 to 3627-36
  7. Summary of components, pages 37 to 4437-44
  8. Fitting, pages 45 to 5445-54
  9. Fitting, pages 55 to 6455-64
  10. Fitting, pages 65 to 7465-74
  11. Installation, pages 75 to 8475-84
  12. Installation, pages 85 to 9485-94
  13. Commissioning95-106
  14. Diagnosis and error treatment, pages 107 to 115107-115
  15. Diagnosis and error treatment, pages 116 to 124116-124
  16. Diagnosis and error treatment, pages 125 to 132125-132
  17. Technical appendix133-142
  18. Parameters and data of the CPX terminal, pages 143 to 152143-152
  19. Parameters and data of the CPX terminal, pages 153 to 162153-162
  20. Parameters and data of the CPX terminal, pages 163 to 172163-172
  21. Parameters and data of the CPX terminal, pages 173 to 182173-182
  22. Parameters and data of the CPX terminal, pages 183 to 188183-188
  23. General information on parametrizing, pages 189 to 197189-197
  24. General information on parametrizing, pages 198 to 206198-206
  25. General information on parametrizing, pages 207 to 214207-214
  26. Index215-221

The file

Revision and size

RevisionP.BE-CPX-SYS-EN, en 0503b
PublisherFesto
Pages221
PDF2.2 MB
TextText from the PDF itself.

The first pages · 3 of 221

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 221
Page 2
Page 2of 221
Page 3
Page 3of 221

More documents · 1

For the same models